Skip to content
Industrial

Mitsubishi Electric FX5U-64MT/DS

FX5U CPU Module, 64 I/O, Transistor Sink Outputs, DC Supply

Mitsubishi Electric
Mitsubishi Electric FX5U-64MT/DS, Mitsubishi Electric product photo

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Mitsubishi Electric FX5U-64MT/DS is a MELSEC iQ-F FX5U CPU module with 32 inputs and 32 transistor sink outputs built in and a DC power supply.

Manufacturer part no.
FX5U-64MT/DS
Type
MELSEC iQ-F FX5 CPU module
Lifecycle
Active
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Mitsubishi Electric
Manufacturer part no.
FX5U-64MT/DS
Type
MELSEC iQ-F FX5 CPU module
Application
PLC controller
Used with
MELSEC iQ-F expansion modules
Control system
Stored-program repetitive operation
Input/output control system
Refresh system; (Direct access input/output allowed by specification of direct access input/output [DX, DY])
No. of input/output points, (1) No. of input/output points
256 points or less/384 points or less*; *Supported with CPU module firmware version 1.100 and later. In addition, GX Works3 version 1.047Z and later is required.
No. of input/output points, (2) No. of remote I/O points
384 points or less/512 points or less*; *Supported with CPU module firmware version 1.100 and later. In addition, GX Works3 version 1.047Z and later is required.
No. of input/output points, Total No. of points of (1) and (2)
512 points or less
Programming specifications, Programming language
Ladder diagram (LD), structured text (ST), function block diagram/ladder diagram (FBD/LD), sequential function chart (SFC)*; *For supported versions, refer to MELSEC iQ-F FX5 User's Manual (Application).
Programming specifications, Programming extension function
Function block (FB), function (FUN), label programming (local/global)
Programming specifications, Constant scan
0.2 to 2000 ms (can be set in 0.1 ms increments)
Programming specifications, Fixed cycle interrupt
1 to 60000 ms (can be set in 1 ms increments)
Programming specifications, Timer performance specifications
100 ms, 10 ms, 1 ms
Programming specifications, No. of program executions
32
Programming specifications, No. of FB files
16 (Up to 15 for user)
Command processing time, LD X0
34 ns*; *When the program capacity is 64 k steps.
Command processing time, MOV D0 D1
34 ns*; *When the program capacity is 64 k steps.
Memory capacity, Program capacity
64 k steps/128 k steps* (128 kbytes/256 kbytes, flash memory); *Supported with CPU module firmware version 1.100 or later. In addition, GX Works3 version 1.047Z or later is required.
Memory capacity, SD memory card
Memory card capacity (SD/SDHC memory card: Max. 16 Gbytes)
Memory capacity, Device/label memory
120 kbytes
Memory capacity, Data memory/standard ROM
5 Mbytes
Clock function, Display data
Year, month, day, hour, minute, second, day of week (leap year automatic detection)
Clock function, Precision
Differences per month ±45 sec./25℃ (TYP)
Power failure retention (clock data), Retention method
Large-capacity capacitor; Clock data is retained using the power accumulated in a large-capacity capacitor incorporated into the PLC. When voltage of the large-capacity capacitor drops, clock data is no longer accurately retained. The retention period of a fully charged capacitor (electricity is conducted across the PLC for at least 30 minutes) is 10 days (ambient temperature: 25℃). How long the capacitor can hold the data depends on the operating ambient temperature. When the operating ambient temperature is high, the holding period is short.
Power failure retention (clock data), Retention time
10 days (Ambient temperature: 25℃)
Rated voltage
24 V DC
Voltage fluctuation range
-30%, +20%
Frequency rating
-
Show all 107 specifications
Allowable instantaneous power failure time
Operation can be continued upon occurrence of instantaneous power failure for 5 ms or less.
Power fuse
250 V, 5 A Time-lag fuse
Rush current
65 A max. 2.0 ms or less/24 V DC
Power consumption
40 W; Maximum consumption value when using the maximum configuration connectable to the CPU module.
24 V DC built-in power supply capacity
740 mA (530 mA); The value in () is capacity of power supply when the supply voltage is 16.8-19.2 V DC.
5 V DC built-in power supply capacity
1100 mA (975 mA); The value in () is capacity of power supply when the supply voltage is 16.8-19.2 V DC.
No. of input points
32 points
Input connection type
Removable terminal block (M3 screws)
Input type
Sink/source
Input signal voltage
24 V DC +20%, -15%
Input signal current, X0 to X17
5.3 mA/24 V DC
Input signal current, X20 and subsequent
4.0 mA/24 V DC
Input impedance, X0 to X17
4.3 kΩ
Input impedance, X20 and subsequent
5.6 kΩ
ON input sensitivity current, X0 to X17
3.5 mA or more
ON input sensitivity current, X20 and subsequent
3.0 mA or more
OFF input sensitivity current
1.5 mA or less
Input response frequency, X0 to X7
200 kHz; When capturing pulses of a response frequency of 50 to 200 kHz, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).
Input response frequency, X10 to X17
10 kHz
Input response frequency, X20 and subsequent
0.1±0.05 kHz
Pulse waveform, X0 to X7
T1 (pulse width): 2.5 μs or more; T2 (rise/fall time): 1.25 μs or less
Pulse waveform, X10 to X17
T1 (pulse width): 50 μs or more; T2 (rise/fall time): 25 μs or less
Input response time (H/W filter delay), X0 to X7
ON: 2.5 μs or less; OFF: 2.5 μs or less
Input response time (H/W filter delay), X10 to X17
ON: 30 μs or less; OFF: 50 μs or less
Input response time (H/W filter delay), X20 and subsequent
ON: 50 μs or less; OFF: 150 μs or less
Input response time (Digital filter setting value)
None, 10 μs, 50 μs, 0.1 ms, 0.2 ms, 0.4 ms, 0.6 ms, 1 ms, 5 ms, 10 ms (initial values), 20 ms, 70 ms; When using this product in an environment with much noise, set the digital filter.
Input signal format (Input sensor form)
No-voltage contact input; Sink: NPN open collector transistor; Source: PNP open collector transistor
Input circuit insulation
Photo-coupler insulation
Indication of input operation
LED is lit when input is on
No. of output points
32 points
Output connection type
Removable terminal block (M3 screws)
Output type
Transistor/sink output
External power supply
5-30 V DC
Max. load
0.5 A/point; The total load current per common terminal should be the following value.; 4 output points/common terminal: 0.8 A or less; 8 output points/common terminal: 1.6 A or less
Open circuit leakage current
0.1 mA or less/30 V DC
Voltage drop when ON, Y0 to Y3
1.0 V or less
Voltage drop when ON, Y4 and subsequent
1.5 V or less
Response time, Y0 to Y3
2.5 μs or less/10 mA or more (5-24 V DC)
Response time, Y4 and subsequent
0.2 ms or less/200 mA or more (24 V DC)
Output circuit insulation
Photo-coupler insulation
Indication of output operation
LED is lit when output is on
Clock function
This function is used for the time management in the function which the system operates such as the date of the event history function, and data logging function.
PID control function
Performs PID control by the PID control instruction.
Constant scan
Keeps the scan time constant and executes program repeatedly.
High-speed input/output function, High-speed counter function
Performs high-speed counter, pulse width measurement, input interruption, etc. by using the input of the CPU module or high-speed pulse input/output module.
High-speed input/output function, Pulse width measurement function
Performs high-speed counter, pulse width measurement, input interruption, etc. by using the input of the CPU module or high-speed pulse input/output module.
High-speed input/output function, Input interrupt function
Performs high-speed counter, pulse width measurement, input interruption, etc. by using the input of the CPU module or high-speed pulse input/output module.
High-speed input/output function, Positioning function
Executes positioning operation by using the transistor output of the CPU module or high-speed pulse input/output module.
High-speed input/output function, PWM output function
Executes a PWM output by using the transistor output of the CPU module or high-speed pulse input/output module.
Built-in analog function, Analog input function
Two analog inputs are built in the FX5U CPU module so that voltage input can be performed.
Built-in analog function, Analog output function
One analog output are built in the FX5U CPU module so that voltage output can be performed.
Built-in Ethernet function
An Ethernet related function such as connection to MELSOFT products and GOTs, socket communication, file transfer using FTP, Web server (HTTP), SNTP client, and simple CPU communication function.
CC-Link IE Field Network Basic function
This function exchanges data between the manager station and remote station using general-purpose Ethernet.
Serial communication function
A function related to the serial communication such as N:N Network, parallel link, MC protocol, inverter communication function and non-protocol communication.
MODBUS communication function
Connection with the products which support MODBUS RTU/TCP is available. The master and slave functions can be used.
Operating ambient temperature
-20 to 55℃, non-freezing; The simultaneous ON ratio of available PLC inputs or outputs changes with respect to the ambient temperature, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).; The operating ambient temperature is 0 to 55℃ for products manufactured before June 2016. For details on Intelligent function modules, refer to manuals of each product.; In the case where operating ambient temperature is lower than 0℃, the specifications are different from the above description. For details, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).
Storage ambient temperature
-25 to 75℃, non-freezing
Operating ambient humidity
5 to 95%RH, non-condensation; When used in a low-temperature environment, use in an environment with no sudden temperature changes. If there are sudden temperature changes because of opening/closing of the control panel or other reasons, condensation may occur, which may cause a fire, fault, or malfunction. Furthermore, use an air conditioner in dehumidifier mode to prevent condensation.
Storage ambient humidity
5 to 95%RH, non-condensation
Vibration resistance, Installed on DIN rail, Frequency: 5 to 8.4 Hz
Half amplitude: 1.75 mm 10 times each in X, Y, Z directions (80 min in each direction); The criterion is shown in IEC61131-2.; When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Vibration resistance, Installed on DIN rail, Frequency: 8.4 to 150 Hz
Acceleration: 4.9 m/s 2 10 times each in X, Y, Z directions (80 min in each direction); The criterion is shown in IEC61131-2.; When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Vibration resistance, Direct installing, Frequency: 5 to 8.4 Hz
Half amplitude: 3.5 mm 10 times each in X, Y, Z directions (80 min in each direction); The criterion is shown in IEC61131-2.; When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Vibration resistance, Direct installing, Frequency: 8.4 to 150 Hz
Acceleration: 9.8 m/s 2 10 times each in X, Y, Z directions (80 min in each direction); The criterion is shown in IEC61131-2.; When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Shock resistance
147 m/s 2 , Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z; The criterion is shown in IEC61131-2.
Noise durability
By noise simulator at noise voltage of 1000 Vp-p, noise width of 1 μs and period of 30 to 100 Hz
Dielectric withstand voltage, Between power supply terminal (DC power supply) and ground terminal
500 V AC for one minute
Dielectric withstand voltage, Between input terminal (24 V DC) and ground terminal
500 V AC for one minute
Dielectric withstand voltage, Between output terminal (transistor) and ground terminal
500 V AC for one minute
Insulation resistance, Between power supply terminal (DC power supply) and ground terminal
10 MΩ or higher by 500 V DC insulation resistance tester
Insulation resistance, Between input terminal (24 V DC) and ground terminal
10 MΩ or higher by 500 V DC insulation resistance tester
Insulation resistance, Between output terminal (transistor) and ground terminal
10 MΩ or higher by 500 V DC insulation resistance tester
Grounding
Class D grounding (grounding resistance: 100 Ω or less); (Common grounding with a heavy electrical system is not allowed); For grounding, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).
Working atmosphere
Free from corrosive or flammable gas and excessive conductive dust
Operating altitude
0 to 2000 m; The PLC cannot be used at a pressure higher than the atmospheric pressure to avoid damage.
Installation location
Inside a control panel; The programmable controller is assumed to be installed in an environment equivalent to indoor.
Overvoltage category
II or less; This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
Pollution degree
2 or less; This index indicates the degree to which conductive material is generated in the environment in which the equipment is used. Pollution level 2 is when only non-conductive pollution occurs. Temporary conductivity caused by condensation must be expected occasionally.

Technical documents (1)

Key features

  • Built-in analog input: 2 ch
  • Built-in analog output: 1 ch
  • Built-in high-speed counter: Up to 8 ch 200 kHz
  • Built-in positioning: Up to 200 kHz 4 axis

About the Mitsubishi Electric FX5U-64MT/DS

The Mitsubishi Electric FX5U-64MT/DS is a MELSEC iQ-F FX5U CPU module, combining the CPU, I/O and power supply. Mitsubishi Electric's overview gives it 32 inputs (24 V DC sink/source) and 32 outputs (transistor sink). Built in, from the same overview: analog input: 2 ch; analog output: 1 ch; high-speed counter: Up to 8 ch 200 kHz. Mitsubishi Electric lists it as on sale.

What is the FX5U-64MT/DS used for?

The FX5U-64MT/DS controls a machine from its own 64 I/O; Mitsubishi Electric gives 512 points or less in total including remote I/O.

Lifecycle and successor

Active.

Before you order

What to photograph or confirm so the right unit is quoted.

Check the model name FX5U-64MT/DS on the rating plate, with the serial number and function version. Send us a photo of the rating plate and we will confirm the details before quoting.

Alternatives for FX5U-64MT/DS

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
Mitsubishi Electric FX5U-64MR/ESFX5U CPU Module, 64 I/O, Relay Outputs, AC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-64MT/ESFX5U CPU Module, 64 I/O, Transistor Sink Outputs, AC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-64MT/ESSFX5U CPU Module, 64 I/O, Transistor Source Outputs, AC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-80MT/ESSFX5U CPU Module, 80 I/O, Transistor Source Outputs, AC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-32MR/DSFX5U CPU Module, 32 I/O, Relay Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-32MT/DSFX5U CPU Module, 32 I/O, Transistor Sink Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-32MT/DSSFX5U CPU Module, 32 I/O, Transistor Source Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-64MR/DSFX5U CPU Module, 64 I/O, Relay Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-64MT/DSSFX5U CPU Module, 64 I/O, Transistor Source Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-80MR/DSFX5U CPU Module, 80 I/O, Relay Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-80MT/DSFX5U CPU Module, 80 I/O, Transistor Sink Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›
Mitsubishi Electric FX5U-80MT/DSSFX5U CPU Module, 80 I/O, Transistor Source Outputs, DC SupplyMitsubishi ElectricMELSEC iQ-F FX5 CPU moduleActiveSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Mitsubishi Electric FX5U-64MT/DS? Send us the details.