1794-ADN discontinued: replacement spares and error 77
Why a 1794-ADN spare with the same part number can fail with error 73 or 77, and what to check before accepting one.
By TimControls Technical TeamPublished

Kongsberg Maritime has issued discontinuation notices for AutoChief C20, AutoChief 4 and 7, and for computers, panels and modules across its DataChief and K-Chief systems. This guide brings together 25 notices issued between 2012 and 2025, covering affected equipment, support limitations and recommended upgrade routes.
Key takeaways
AutoChief is Kongsberg’s main engine remote control system, covering bridge control, the engine telegraph and the governor. DataChief and K-Chief handle alarm, monitoring and control of the machinery, including power management. Kongsberg delivered its first AutoChief in 1967 and reports more than 13,000 propulsion remote control systems delivered by 2025. Older installations often still carry the Norcontrol name.
Ships usually outlast their automation hardware. Kongsberg’s earlier lifecycle policy assumes an installation life of up to 40 years, while workstation computers, panels and processing modules are supported for much shorter periods. When Kongsberg can no longer support a product, it issues a product discontinuation notice addressed to the owner’s technical director and posts it on the product’s page.
Those letters are spread across many product pages, vary in wording and often refer to one another. Establishing whether a module is affected means finding the right letter, checking its date and confirming that no later letter has changed the position.
We compiled this register so that superintendents, ETOs and buyers can check a system, computer or part number against Kongsberg’s notices without working through the letters one by one, and decide whether to source an exact spare, repair the unit or plan an upgrade. Each row gives the notice date, what Kongsberg said about support, and the route it recommended at the time.
Lifecycle statuses are based on Kongsberg’s published notices and describe the level of manufacturer support for the affected equipment. They do not necessarily apply to the entire system.
Kongsberg declared AutoChief C20 obsolete as a complete system on 17 June 2025. The notice covers the propulsion remote control system, including its digital governor, remote control panels and telegraph.
More than 3,000 AutoChief C20 systems were delivered between 2004 and 2014. The governor components explicitly named in the notice are therefore particularly relevant to spare parts planning.
Earlier notices also cover AutoChief 4 and 7, delivered between 1990 and 2007, and AutoChief 2 and 3, delivered until 1994.
| System | Affected equipment | Notice | Status | OEM route | Parts |
|---|---|---|---|---|---|
| AutoChief C20 propulsion control system | Digital governor, remote control panels and telegraph. Includes KM Actuator 1325/1335, DSU15 servo controller, MCW 151, SEFA 160/800 and ELACT 0516. | 17 June 2025 | ObsoleteKongsberg can no longer fully support the system with spare parts and services. | Upgrade to AutoChief 600 | |
| AutoChief 4 (FPP) AutoChief 7 (CPP) | Remote control, telegraph and governor. | 2 February 202117 June 2025 | ObsoleteKongsberg can no longer fully support the system with spare parts and services. | Upgrade to AutoChief 600 | — |
| AutoChief 2 AutoChief 3 | The whole system, including the DGS 8800 pneumatic actuator. | 2 June 2014 | Limited supportReplacement parts unavailable; very limited hardware service remains for AutoChief 3. | Upgrade the complete system to AutoChief 600 | — |
No notice in this register withdraws K-Chief 600, AutoChief 600 or K-Steering 600 as a complete system. The notices concern the operator station computers and the CP7 control panel, the most recent dated 29 September 2025.
The CP7 was delivered from 2015 to 2024. Kongsberg’s route for both the operator stations and the panel is a newer computer, and the K-Chief 600 I/O modules are not named in any notice.
| System | Affected equipment | Notice | Status | OEM route | Parts |
|---|---|---|---|---|---|
| CP7 control panel | Used on K-Chief 600, AutoChief 600 and K-Steering 600 | 29 September 2025 | ObsoleteKongsberg can no longer fully support the equipment with spare parts or services. | Upgrade the panel PC to Kongsberg’s latest computer with touchscreen panel | |
| K-Chief 600 operator station computers | Lenovo MC330 and MC340, MP8200, MP8300, MP5810, Hatteland AIPC 8 and 13 inch, Hatteland IPC 13 inch, ISIC CP7 and C12 | 4 February 2025 | Support endedSupport discontinued for the listed computers. | Upgrade to the latest type approved marine computer | |
| K-Chief 600 workstation | MP8200 | 23 May 2018 | Support endedMP8200 support discontinued. Full software and field support for K-Chief 600 was available at the time of the notice. | Upgrade to the latest type approved marine computer |
Neither DataChief C20 nor K-Chief 500 has a whole system notice. Kongsberg has ended support for their operator station computers, in stages from 2014 to April 2025, and for the MCI master clock interface in 2014.
On 30 September 2025 it declared the C1 Combi and C3-GDCP power management modules obsolete. DataChief C20 was delivered from 1998 to 2008.
| System | Affected equipment | Notice | Status | OEM route | Parts |
|---|---|---|---|---|---|
| K-Chief 500 operator station computers | ISIC PCM4, MP7600, MP7900, MP8200, MP8300, MP5810, ISIC CP7 and C12, Hatteland AIPC 8 and 13 inch, Hatteland IPC 13 inch | 22 April 2025 | Support endedSupport discontinued for the listed computers. Limited software and field service remained for K-Chief 500. | Total retrofit to K-Chief 600 | |
| K-Chief 500 workstation | MP8200 | 23 May 2018 | Support endedMP8200 support discontinued. Full software and field support for K-Chief 500 was available at the time of the notice. | Latest type approved marine computer, K-Chief 600 software or total retrofit | |
| K-Chief 500 workstation | MP7900 | 7 May 2014 | ObsoleteComputer and spare parts obsolete. Full software and field support for K-Chief 500 remained at the time of the notice. | MP8300, K-Chief 600 software or total retrofit | |
| K-Chief 500 workstation | MP7600 | 26 February 2014 | ObsoleteComputer and spare parts obsolete. Full software and field support for K-Chief 500 remained at the time of the notice. | MP8200 or MP8300, K-Chief 600 software or total retrofit | |
| Power management modules | C1 Combi (8100181) and C3-GDCP (8100225) on DataChief C20 and K-Chief 500 | 30 September 2025 | ObsoleteKongsberg can no longer fully support systems using these modules with spare parts and services. | Upgrade K-Chief and power management to the latest generation | |
| DataChief C20 operator station PCs | HP VL6, HP VL400 and HP D530 | 3 April 2024 | Limited supportNo spare parts; repair possible where feasible. Limited software and field support for DataChief C20. | Partial upgrade or full retrofit to K-Chief 600 | — |
| MCI master clock interface | DataChief 2000 and DataChief C20 | 25 March 2014 | Limited supportSpare parts support discontinued; limited hardware service remains. | An NMEA 0183 serial interface on DataChief C20; local time setting at the MCU on DataChief 2000 | — |
DataChief 2000 (delivered 1992 to 2000), DataChief 7 (until 1994) and DataChief 1000 (1994 to 1998) lost their Kongsberg spare parts between 2012 and 2018, and the KM-1, KD-10 and KD-20 systems delivered by Autronica did so in 2014.
KM-2 and KD-30 reached their last time buy in 2016, after which all support ended. For each of these systems, Kongsberg names a retrofit to K-Chief 600.
| System | Affected equipment | Notice | Status | OEM route |
|---|---|---|---|---|
| DataChief 2000 MCUs | All types | 4 February 2012 | Limited supportNo spare parts; limited software and hardware service. | Top system upgrade or total retrofit to K-Chief 600 |
| DataChief 2000 software changes | Software modification support; limited hardware service for the DBU | 10 June 2015 | Support endedSoftware modifications discontinued; limited hardware service for the DBU. | Top system upgrade keeping the Watch Call system and the SAU, SAX, LGU and AC4 modules, or total retrofit to K-Chief 600 |
| DataChief 2000 computers | Fleetmaster, Shipviewer and DC2000 PC | 1 January 2018 | Limited supportNo spare parts; limited repair service. | Retrofit to K-Chief 600 |
| DataChief 7 processing units | SPU8610 and SPU8620 | 3 July 2013 | Limited supportNo replacement parts; limited hardware service. | Top system upgrade to K-Chief 500, or total retrofit to K-Chief 600 |
| DataChief 7 signal acquisition unit | SAU8800 | 18 November 2013 | Limited supportNo replacement parts; very limited hardware service. | Top system upgrade or total retrofit to K-Chief 600 |
| DataChief 1000 MCUs | All types | 4 February 2012 | Limited supportNo spare parts; limited software and hardware service. | Top system upgrade or total retrofit to K-Chief 600 |
| KM-1, KD-10 and KD-20 engine room systems | Delivered by Autronica | 1 November 2014 | Limited supportNo spare parts; repair possible where feasible. | Total retrofit to K-Chief 600 |
| KD-30 alarm and control system | Last time buy by 1 August 2016; all support ended after 1 October 2016 | 10 December 2015 | Support endedLast time buy deadline 1 August 2016. All support ended after 1 October 2016. | Total retrofit to K-Chief 600 |
| KM-2 alarm system | Last time buy by 1 June 2016; all support ended after 1 August 2016 | 21 April 2016 | Support endedLast time buy deadline 1 June 2016. All support ended after 1 August 2016. | Total retrofit to K-Chief 600 |
Two Kongsberg notices cover bridge watch monitoring rather than engine room automation. The 2014 notice raises a compliance question as well as a spares question, because a replacement part does not settle whether an installed system meets the rules that apply to a ship today.
| System | Affected equipment | Notice | Status | OEM route |
|---|---|---|---|---|
| DataChief 2000 bridge watch monitoring system | WBU type, delivered 1993 to 2003 | 25 March 2014 | Support endedSupport discontinued. These installations were not type approved under SOLAS chapter V regulation 19 as amended, and spare parts for the watch timer unit ended. | BWMS C20 (MOS type) named as the successor |
| C20 bridge watch monitoring system | Spares and corrective software maintenance for 10 years or more from 2015 for existing installations | 1 January 2015 | Sales stoppedSales stopped. Corrective software maintenance and hardware spares continue for 10 years or more for existing installations. | None named |
Kongsberg’s discontinuation notices show how support and replacement recommendations have changed over time. Some computers originally recommended as replacements were later discontinued, while different modules within the same system received different support arrangements.
Kongsberg issued five notices in 2025, more than in any year covered by this register since 2014. They primarily concern operator station computers, control panels and the AutoChief C20 generation.
4 February
K-Chief 600 operator stations
Support ended for the specified computers, including MP8200, MP8300 and Lenovo MC330/MC340.
22 April
K-Chief 500 operator stations
Support ended for the listed computers. Total retrofit to K-Chief 600 was the only route named.
17 June
AutoChief C20
The complete system was declared obsolete, including digital governor equipment. The notice also repeated the position on AutoChief 4 and 7.
29 September
CP7 control panel
Declared obsolete for K-Chief 600, AutoChief 600 and K-Steering 600.
30 September
C1 Combi and C3-GDCP
Power management modules 8100181 and 8100225 were declared obsolete.
For vessels still operating these systems, the latest applicable notice matters as much as the original recommendation.
In 2014, Kongsberg recommended the MP8200 or MP8300 as replacements for the MP7600 workstation on K-Chief 500, and the MP8300 for the MP7900.
The MP8200 subsequently received discontinuation notices in 2018. By 2025, both the MP8200 and MP8300 were included in Kongsberg’s operator station discontinuation notices for K-Chief 500 and K-Chief 600.
The earlier recommendations were valid at the time, but are now covered by later notices. Any workstation replacement should therefore be checked against the 2025 notices rather than relying on the original 2014 guidance.
DataChief 7 illustrates how recommendations could differ even within the same system generation. In July 2013, Kongsberg recommended a top system upgrade to K-Chief 500 for DataChief 7 SPU8610 and SPU8620 units. In November 2013, its notice for the SAU8800 instead named a top system upgrade to K-Chief 600.
Both notices also offered a total retrofit to K-Chief 600. The K-Chief 500 operator station computers were subsequently covered by the April 2025 discontinuation notice. This makes the equipment configuration important when interpreting historical upgrade recommendations.
A system level description does not necessarily reflect the support position of every component. In November 2018, Kongsberg extended spare parts support for selected process network modules used in DataChief 2000, DataChief 1000 and AC-4 until 1 January 2021. The selected modules included RCS, SSU, DGU, ETS, GCU, LGU, SAU, PCU and SAX. However, the extension did not include:
That extended support period has now expired. The notice nevertheless demonstrates why a component’s exact identity matters when determining what manufacturer support may remain available.
For vessels still running these systems, the priority is keeping compatible spares on hand until an upgrade is planned.
With obsolete Kongsberg modules, the risk is getting a unit that has the right part number but the wrong hardware revision or software, and will not work in your system.
At TimControls, we help identify suitable replacements and provide remote technical support during installation and commissioning.
Download the list
All 27 Kongsberg parts and models in the register in one spreadsheet: the systems each one serves, the notice that names it or covers its system, the notice date, how the notice applies and the part page.
Download the list (CSV)Sources: Kongsberg Maritime: AutoChief C20 number 2000 sold (2010); Kongsberg Maritime: AutoChief 600 product sheet; Kongsberg Maritime: AutoChief 4 to AutoChief 600 conversion kit; Kongsberg Maritime: K-Chief automation system and questions and answers; Kongsberg Maritime: Lifecycle management policy KM-POL-0011, 4 November 2024.
Register coverage: 25 Kongsberg notices dated 2012 to 2025, reviewed on 28 October 2026. It is not a complete archive of Kongsberg notices.
TimControls Technical Team researches lifecycle notices and sources current, surplus and discontinued automation parts. TimControls is an independent distributor and is not an authorised Kongsberg distributor. Kongsberg names and part numbers identify equipment only.
Why a 1794-ADN spare with the same part number can fail with error 73 or 77, and what to check before accepting one.
Rockwell status, discontinued date and replacement category for each SLC 500 and PLC-5 processor we list, with the Rockwell source. Free CSV download.
Danfoss no longer supplies spares or service for the VLT 5000, 6000 HVAC or 8000 AQUA. Successors by region, and the Danfoss rating of every drive we list.