Skip to content

Lifecycle Database

Kongsberg Maritime Discontinued Products: AutoChief, DataChief and K-Chief (2026)

By TimControls Technical TeamPublished

A container ship at a port at night, with the words Kongsberg Maritime, discontinuation notices 2012 to 2025, AutoChief, DataChief and K-Chief.
Share

Kongsberg Maritime has issued discontinuation notices for AutoChief C20, AutoChief 4 and 7, and for computers, panels and modules across its DataChief and K-Chief systems. This guide brings together 25 notices issued between 2012 and 2025, covering affected equipment, support limitations and recommended upgrade routes.

Key takeaways

  • AutoChief C20 was declared obsolete as a complete system in June 2025, with AutoChief 600 recommended as its replacement.
  • K-Chief 600 remains unaffected as a complete system in the reviewed notices, but certain operator stations and the CP7 panel have been discontinued.
  • C1 Combi (8100181) and C3-GDCP (8100225) power management modules were declared obsolete in September 2025.
  • MP8200 and MP8300, previously recommended as replacements, are now covered by the 2025 discontinuation notices.

How Kongsberg discontinues products

AutoChief is Kongsberg’s main engine remote control system, covering bridge control, the engine telegraph and the governor. DataChief and K-Chief handle alarm, monitoring and control of the machinery, including power management. Kongsberg delivered its first AutoChief in 1967 and reports more than 13,000 propulsion remote control systems delivered by 2025. Older installations often still carry the Norcontrol name.

Ships usually outlast their automation hardware. Kongsberg’s earlier lifecycle policy assumes an installation life of up to 40 years, while workstation computers, panels and processing modules are supported for much shorter periods. When Kongsberg can no longer support a product, it issues a product discontinuation notice addressed to the owner’s technical director and posts it on the product’s page.

Those letters are spread across many product pages, vary in wording and often refer to one another. Establishing whether a module is affected means finding the right letter, checking its date and confirming that no later letter has changed the position.

Kongsberg lifecycle register

We compiled this register so that superintendents, ETOs and buyers can check a system, computer or part number against Kongsberg’s notices without working through the letters one by one, and decide whether to source an exact spare, repair the unit or plan an upgrade. Each row gives the notice date, what Kongsberg said about support, and the route it recommended at the time.

Lifecycle statuses are based on Kongsberg’s published notices and describe the level of manufacturer support for the affected equipment. They do not necessarily apply to the entire system.

AutoChief systems

Kongsberg declared AutoChief C20 obsolete as a complete system on 17 June 2025. The notice covers the propulsion remote control system, including its digital governor, remote control panels and telegraph.

More than 3,000 AutoChief C20 systems were delivered between 2004 and 2014. The governor components explicitly named in the notice are therefore particularly relevant to spare parts planning.

Earlier notices also cover AutoChief 4 and 7, delivered between 1990 and 2007, and AutoChief 2 and 3, delivered until 1994.

SystemAffected equipmentNoticeStatusOEM routeParts
AutoChief C20 propulsion control systemDigital governor, remote control panels and telegraph. Includes KM Actuator 1325/1335, DSU15 servo controller, MCW 151, SEFA 160/800 and ELACT 0516.17 June 2025ObsoleteUpgrade to AutoChief 600
AutoChief 4 (FPP) AutoChief 7 (CPP)Remote control, telegraph and governor.2 February 202117 June 2025ObsoleteUpgrade to AutoChief 600—
AutoChief 2 AutoChief 3The whole system, including the DGS 8800 pneumatic actuator.2 June 2014Limited supportUpgrade the complete system to AutoChief 600—

K-Chief 600, AutoChief 600 and K-Steering 600

No notice in this register withdraws K-Chief 600, AutoChief 600 or K-Steering 600 as a complete system. The notices concern the operator station computers and the CP7 control panel, the most recent dated 29 September 2025.

The CP7 was delivered from 2015 to 2024. Kongsberg’s route for both the operator stations and the panel is a newer computer, and the K-Chief 600 I/O modules are not named in any notice.

SystemAffected equipmentNoticeStatusOEM routeParts
CP7 control panelUsed on K-Chief 600, AutoChief 600 and K-Steering 60029 September 2025ObsoleteUpgrade the panel PC to Kongsberg’s latest computer with touchscreen panel
K-Chief 600 operator station computersLenovo MC330 and MC340, MP8200, MP8300, MP5810, Hatteland AIPC 8 and 13 inch, Hatteland IPC 13 inch, ISIC CP7 and C124 February 2025Support endedUpgrade to the latest type approved marine computer
K-Chief 600 workstationMP820023 May 2018Support endedUpgrade to the latest type approved marine computer

K-Chief 500 and DataChief C20

Neither DataChief C20 nor K-Chief 500 has a whole system notice. Kongsberg has ended support for their operator station computers, in stages from 2014 to April 2025, and for the MCI master clock interface in 2014.

On 30 September 2025 it declared the C1 Combi and C3-GDCP power management modules obsolete. DataChief C20 was delivered from 1998 to 2008.

SystemAffected equipmentNoticeStatusOEM routeParts
K-Chief 500 operator station computersISIC PCM4, MP7600, MP7900, MP8200, MP8300, MP5810, ISIC CP7 and C12, Hatteland AIPC 8 and 13 inch, Hatteland IPC 13 inch22 April 2025Support endedTotal retrofit to K-Chief 600
K-Chief 500 workstationMP820023 May 2018Support endedLatest type approved marine computer, K-Chief 600 software or total retrofit
K-Chief 500 workstationMP79007 May 2014ObsoleteMP8300, K-Chief 600 software or total retrofit
K-Chief 500 workstationMP760026 February 2014ObsoleteMP8200 or MP8300, K-Chief 600 software or total retrofit
Power management modulesC1 Combi (8100181) and C3-GDCP (8100225) on DataChief C20 and K-Chief 50030 September 2025ObsoleteUpgrade K-Chief and power management to the latest generation
DataChief C20 operator station PCsHP VL6, HP VL400 and HP D5303 April 2024Limited supportPartial upgrade or full retrofit to K-Chief 600—
MCI master clock interfaceDataChief 2000 and DataChief C2025 March 2014Limited supportAn NMEA 0183 serial interface on DataChief C20; local time setting at the MCU on DataChief 2000—

Older DataChief, KM and KD systems

DataChief 2000 (delivered 1992 to 2000), DataChief 7 (until 1994) and DataChief 1000 (1994 to 1998) lost their Kongsberg spare parts between 2012 and 2018, and the KM-1, KD-10 and KD-20 systems delivered by Autronica did so in 2014.

KM-2 and KD-30 reached their last time buy in 2016, after which all support ended. For each of these systems, Kongsberg names a retrofit to K-Chief 600.

SystemAffected equipmentNoticeStatusOEM route
DataChief 2000 MCUsAll types4 February 2012Limited supportTop system upgrade or total retrofit to K-Chief 600
DataChief 2000 software changesSoftware modification support; limited hardware service for the DBU10 June 2015Support endedTop system upgrade keeping the Watch Call system and the SAU, SAX, LGU and AC4 modules, or total retrofit to K-Chief 600
DataChief 2000 computersFleetmaster, Shipviewer and DC2000 PC1 January 2018Limited supportRetrofit to K-Chief 600
DataChief 7 processing unitsSPU8610 and SPU86203 July 2013Limited supportTop system upgrade to K-Chief 500, or total retrofit to K-Chief 600
DataChief 7 signal acquisition unitSAU880018 November 2013Limited supportTop system upgrade or total retrofit to K-Chief 600
DataChief 1000 MCUsAll types4 February 2012Limited supportTop system upgrade or total retrofit to K-Chief 600
KM-1, KD-10 and KD-20 engine room systemsDelivered by Autronica1 November 2014Limited supportTotal retrofit to K-Chief 600
KD-30 alarm and control systemLast time buy by 1 August 2016; all support ended after 1 October 201610 December 2015Support endedTotal retrofit to K-Chief 600
KM-2 alarm systemLast time buy by 1 June 2016; all support ended after 1 August 201621 April 2016Support endedTotal retrofit to K-Chief 600

Bridge watch systems

Two Kongsberg notices cover bridge watch monitoring rather than engine room automation. The 2014 notice raises a compliance question as well as a spares question, because a replacement part does not settle whether an installed system meets the rules that apply to a ship today.

SystemAffected equipmentNoticeStatusOEM route
DataChief 2000 bridge watch monitoring systemWBU type, delivered 1993 to 200325 March 2014Support endedBWMS C20 (MOS type) named as the successor
C20 bridge watch monitoring systemSpares and corrective software maintenance for 10 years or more from 2015 for existing installations1 January 2015Sales stoppedNone named

Reading the notices together

Kongsberg’s discontinuation notices show how support and replacement recommendations have changed over time. Some computers originally recommended as replacements were later discontinued, while different modules within the same system received different support arrangements.

2025: Five discontinuation notices

Kongsberg issued five notices in 2025, more than in any year covered by this register since 2014. They primarily concern operator station computers, control panels and the AutoChief C20 generation.

  1. 4 February

    K-Chief 600 operator stations

    Support ended for the specified computers, including MP8200, MP8300 and Lenovo MC330/MC340.

  2. 22 April

    K-Chief 500 operator stations

    Support ended for the listed computers. Total retrofit to K-Chief 600 was the only route named.

  3. 17 June

    AutoChief C20

    The complete system was declared obsolete, including digital governor equipment. The notice also repeated the position on AutoChief 4 and 7.

  4. 29 September

    CP7 control panel

    Declared obsolete for K-Chief 600, AutoChief 600 and K-Steering 600.

  5. 30 September

    C1 Combi and C3-GDCP

    Power management modules 8100181 and 8100225 were declared obsolete.

For vessels still operating these systems, the latest applicable notice matters as much as the original recommendation.

Replacement recommendations can become obsolete

In 2014, Kongsberg recommended the MP8200 or MP8300 as replacements for the MP7600 workstation on K-Chief 500, and the MP8300 for the MP7900.

The MP8200 subsequently received discontinuation notices in 2018. By 2025, both the MP8200 and MP8300 were included in Kongsberg’s operator station discontinuation notices for K-Chief 500 and K-Chief 600.

The earlier recommendations were valid at the time, but are now covered by later notices. Any workstation replacement should therefore be checked against the 2025 notices rather than relying on the original 2014 guidance.

One system, different upgrade routes

DataChief 7 illustrates how recommendations could differ even within the same system generation. In July 2013, Kongsberg recommended a top system upgrade to K-Chief 500 for DataChief 7 SPU8610 and SPU8620 units. In November 2013, its notice for the SAU8800 instead named a top system upgrade to K-Chief 600.

Both notices also offered a total retrofit to K-Chief 600. The K-Chief 500 operator station computers were subsequently covered by the April 2025 discontinuation notice. This makes the equipment configuration important when interpreting historical upgrade recommendations.

Support must be checked module by module

A system level description does not necessarily reflect the support position of every component. In November 2018, Kongsberg extended spare parts support for selected process network modules used in DataChief 2000, DataChief 1000 and AC-4 until 1 January 2021. The selected modules included RCS, SSU, DGU, ETS, GCU, LGU, SAU, PCU and SAX. However, the extension did not include:

  • MCUs already declared obsolete in 2012;
  • OS network parts excluded from the extension.

That extended support period has now expired. The notice nevertheless demonstrates why a component’s exact identity matters when determining what manufacturer support may remain available.

What it means on board

For vessels still running these systems, the priority is keeping compatible spares on hand until an upgrade is planned.

  • AutoChief C20: start with the governor parts named in the June 2025 notice.
  • DataChief C20 and K-Chief 500: focus on the C1 Combi and C3-GDCP power management modules and the operator station computers.
  • K-Chief 600: the notices cover specific computers and the CP7 panel; the system itself is not withdrawn.

With obsolete Kongsberg modules, the risk is getting a unit that has the right part number but the wrong hardware revision or software, and will not work in your system.

At TimControls, we help identify suitable replacements and provide remote technical support during installation and commissioning.

Download the list

All 27 Kongsberg parts and models in the register in one spreadsheet: the systems each one serves, the notice that names it or covers its system, the notice date, how the notice applies and the part page.

Download the list (CSV)

Frequently asked questions

Is AutoChief 600 affected?
The CP7 control panel used on AutoChief 600 was declared obsolete on 29 September 2025. No notice in this register covers AutoChief 600 as a system.
Does Kongsberg still repair AutoChief C20?
The June 2025 notice says Kongsberg can no longer fully support AutoChief C20 with spare parts and services. It does not say repair has stopped for every unit. Whether a given unit can be repaired depends on the fault and on parts for it, and current repair availability needs confirming for the identified unit.
What does Kongsberg mean by obsolete?
In the notices in this register, obsolete means Kongsberg can no longer produce spare parts because components are unavailable, and can no longer fully support the product with parts and services. Some older notices add that repair may still be possible if the part is repairable.

Sources: Kongsberg Maritime: AutoChief C20 number 2000 sold (2010); Kongsberg Maritime: AutoChief 600 product sheet; Kongsberg Maritime: AutoChief 4 to AutoChief 600 conversion kit; Kongsberg Maritime: K-Chief automation system and questions and answers; Kongsberg Maritime: Lifecycle management policy KM-POL-0011, 4 November 2024.

Register coverage: 25 Kongsberg notices dated 2012 to 2025, reviewed on 28 October 2026. It is not a complete archive of Kongsberg notices.

TimControls Technical Team researches lifecycle notices and sources current, surplus and discontinued automation parts. TimControls is an independent distributor and is not an authorised Kongsberg distributor. Kongsberg names and part numbers identify equipment only.

Related articles

View all

Need a Kongsberg part? Send the part number or a label photo.

Added to cart