Mitsubishi Electric R60TCTRT2TT2BW
MELSEC iQ-R Temperature control module, 4 temperature input channels

Image is for illustrative purposes only. Please refer to product description.
Delivery options
Mitsubishi Electric R60TCTRT2TT2BW is a MELSEC iQ-R temperature control module with 4 temperature input channels, Pt100, JPt100 RTD input and transistor control output.
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- R60TCTRT2TT2BW
- Product family
- Mitsubishi MELSEC iQ-R I/O Modules
- Type
- Temperature control module
- Lifecycle
- Active
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- R60TCTRT2TT2BW
- Type
- Temperature control module
- Application
- I/O module
- Used with
- MELSEC iQ-R base units
- Control output
- Transistor output
- Number of temperature input points
- 4 channels/module
- Applicable thermocouple
- R, K, J, T, S, B, E, N, U, L, PLII, W5Re/W26Re
- Applicable resistance temperature detector
- Pt100, JPt100
- Accuracy, Indication accuracy, Ambient temperature: 25±5 ˚C
- Full scale × (±0.3 %)
- Accuracy, Indication accuracy, Ambient temperature: 0...55 ˚C
- Full scale × (±0.7 %)
- Accuracy, Cold junction compensation accuracy: (ambient temperature: 0...55 ˚C), Measured temperature: -100 ˚C or more
- Within ±1.0 ˚C
- Accuracy, Cold junction compensation accuracy: (ambient temperature: 0...55 ˚C), Measured temperature: -150...-100 ˚C
- Within ±2.0 ˚C
- Accuracy, Cold junction compensation accuracy: (ambient temperature: 0...55 ˚C), Measured temperature: -200...-150 ˚C
- Within ±3.0 ˚C
- Sampling cycle
- 250 ms/4 channels, 500 ms/4 channels
- Control output cycle
- 0.5...100 s
- Input impedance
- 1 MΩ
- Input filter
- 0...100 s (0: Input filter OFF)
- Sensor correction value setting
- When the R mode is used: ; (-(full scale of input range)) to full scale of input range; ; When the Q compatible mode function is used: ; -50.00...50.00 %
- Operation at sensor input disconnection
- Up-scale processing
- Temperature control method
- PID ON/OFF pulse or two-position control
- PID constants range, PID constants setting
- Can be set by auto tuning.
- PID constants range, Proportional band (P)
- When the R mode is used: ; 0(0.0) to full scale of input range (depending on the decimal point position) (0: Two-position control); ; When the Q compatible mode function is used: ; 0.0...1000.0 % (0: Two-position control)
- PID constants range, Integral time (I)
- 0...3600 s (set 0 for P control and PD control)
- PID constants range, Derivative time (D)
- 0...3600 s (set 0 for P control and PI control)
- Set value (SV) setting range
- Within the temperature range set in the thermocouple/platinum resistance thermometer to be used.
- Dead band setting range
- When the R mode is used: ; 0(0.0) to full scale of input range (depending on the decimal point position); ; When the Q compatible mode function is used: ; 0.1...10.0 %
- Transistor output, Output signal
- ON/OFF pulse
- Transistor output, Rated load voltage
- 10...30 V DC
- Transistor output, Maximum load current
- 0.1 A/point, 0.4 A/common
Show all 49 specificationsShow fewer
- Transistor output, Maximum inrush current
- 0.4 A, 10 ms
- Transistor output, Leakage current at OFF
- 0.1 mA or less
- Transistor output, Maximum voltage drop at ON
- 1.0 V DC (TYP.) 0.1 A, 2.5 V DC (MAX.) 0.1 A
- Transistor output, Response time, OFF to ON
- 2 ms or less
- Transistor output, Response time, ON to OFF
- 2 ms or less
- Isolation method
- Between input terminals and programmable controller power supply, between input channels: Transformer
- Dielectric withstand voltage
- Between input terminals and programmable controller power supply, between input channels: 500 V AC for 1 minute
- Insulation resistance
- Between input terminals and programmable controller power supply, between input channels: 500 V DC, 20 MΩ or higher
- Heater disconnection detection specifications, Current sensor
- U.R.D. Co., LTD.; ・ CTL-12-S36-10 (0.0...100.0 A); ・ CTL-12-S56-10 (0.0...100.0 A); ・ CTL-6-P-H (0.00...20.00 A); ・ CTL-6-S-H (0.00...20.00 A); ・ CTL-12L-8 (0.00...100.00 A)
- Heater disconnection detection specifications, Input accuracy
- Full scale × (±1.0 %)
- Heater disconnection detection specifications, Number of alert delay
- 3...255
- External interface
- 18-point terminal block (M3 screw) × 2
- Number of occupied I/O points
- 32 points, 2 slots (I/O assignment: Empty 16 points + Intelligent 16 points)
- Internal current consumption (5 V DC)
- 0.31 A
- External dimensions, Height
- 106 mm (base unit mounting side: 98 mm)
- External dimensions, Width
- 56 mm
- External dimensions, Depth
- 131 mm
- Weight
- 0.35 kg
- General specifications
- Refer to the general specifications of the CPU module or remote head module.
Technical documents (1)
Key features
- Control output: Transistor output
- Applicable thermocouple: R, K, J, T, S, B, E, N, U, L, PLII, W5Re/W26Re
- Sampling cycle: 250 ms/4 channels, 500 ms/4 channels
- Control output cycle: 0.5...100 s
- Input impedance: 1 MΩ
About the Mitsubishi Electric R60TCTRT2TT2BW
The Mitsubishi Electric R60TCTRT2TT2BW is a MELSEC iQ-R temperature control module. Mitsubishi Electric's overview: 4 channels, thermocouple (K, J, T, B, S, E, R, N, U, L, PLII, W5Re/W26Re), platinum RTD (Pt100, JPt100), heater disconnection detection, sampling cycle: 250 ms/4 channels, 500 ms/4 channels, 18-point terminal block x 2, channel isolated: heating/cooling control. Mitsubishi Electric lists it as on sale.
What is the R60TCTRT2TT2BW used for?
The R60TCTRT2TT2BW mounts on a MELSEC iQ-R base unit and connects field signals to the CPU, which reads or writes them each cycle.
Lifecycle and successor
Active.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the model name R60TCTRT2TT2BW on the rating plate, with the serial number and function version. Send us a photo of the rating plate and we will confirm the details before quoting.
Alternatives for R60TCTRT2TT2BW
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| Mitsubishi Electric R60DA8-GMELSEC iQ-R Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60DA16-GMELSEC iQ-R Analogue output module, 16 analogue output channels | Mitsubishi Electric | Analog output module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60DAV8MELSEC iQ-R Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60DAI8MELSEC iQ-R Analogue output module, 8 channels, input (resolution): 0...32000 | Mitsubishi Electric | Analog output module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60TD8-GMELSEC iQ-R Analogue input module, 8 channels, thermocouple (B, R, S, K, E, J, T, N) | Mitsubishi Electric | Analog input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60RD8-GMELSEC iQ-R Analogue input module, 8 channels, RTD (Pt100, JPt100, Ni100, Pt50) | Mitsubishi Electric | Analog input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60TRD4-GMELSEC iQ-R Analogue input module, 4 analogue input channels | Mitsubishi Electric | Analog input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60TCTRT2TT2-TSMELSEC iQ-R Temperature control module, 4 temperature input channels | Mitsubishi Electric | Temperature control module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60TCTRT2TT2MELSEC iQ-R Temperature control module, 4 temperature input channels | Mitsubishi Electric | Temperature control module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60TCRT4-TSMELSEC iQ-R Temperature control module, 4 temperature input channels | Mitsubishi Electric | Temperature control module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60TCRT4MELSEC iQ-R Temperature control module, 4 temperature input channels | Mitsubishi Electric | Temperature control module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric R60TCRT4BWMELSEC iQ-R Temperature control module, 4 temperature input channels | Mitsubishi Electric | Temperature control module | Active | Same family | On Request | On request | View › |
You may also be interested in

Mitsubishi Electric
Mitsubishi Electric FX5UC-32MT/DSS-TS
View ›
Mitsubishi Electric
Mitsubishi Electric FX5UC-32MR/DS-TS
View ›
Mitsubishi Electric
Mitsubishi Electric FX5UC-64MT/D
View ›
Mitsubishi Electric
Mitsubishi Electric FX5UC-64MT/DSS
View ›
Mitsubishi Electric
Mitsubishi Electric FX5UC-96MT/D
View ›
Mitsubishi Electric
Mitsubishi Electric FX5UC-96MT/DSS
View ›Mitsubishi Electric
Mitsubishi Electric FX5UJ-24MR/ES
View ›Mitsubishi Electric
Mitsubishi Electric FX5UJ-24MT/ES
View ›Mitsubishi Electric
Mitsubishi Electric FX5UJ-24MT/ESS
View ›Mitsubishi Electric
Mitsubishi Electric FX5UJ-40MR/ES
View ›Mitsubishi Electric
Mitsubishi Electric FX5UJ-40MT/ES
View ›Mitsubishi Electric
Mitsubishi Electric FX5UJ-40MT/ESS
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.