Image is for illustrative purposes only. Please refer to product description.
Delivery options
Mitsubishi Electric RX40NC6S-TS is a MELSEC iQ-R input module with 16 inputs, DC inputs and 24 V DC input.
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- RX40NC6S-TS
- Product family
- Mitsubishi MELSEC iQ-R I/O Modules
- Type
- Digital input module
- Category
- I/O modules › Digital input and output modules
- Lifecycle
- Active
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- RX40NC6S-TS
- Type
- Digital input module
- Application
- I/O module
- Used with
- MELSEC iQ-R base units
- Input type
- DC input (negative common type)
- Number of input points
- 16 points (single wiring); 8 points (double wiring)
- Rated input voltage
- 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC)
- Rated input current
- Approx. 6.8 mA TYP. (at 24 V DC)
- ON voltage/ON current
- 11 V or more/4 mA or more
- OFF voltage/OFF current
- 5 V or less/1.5 mA or less
- Input resistance
- Approx. 3.2 kΩ
- Input common terminal arrangement
- 16 points/common
- Input circuit response time, OFF to ON
- 0.4 ms or less (at 24 V DC)
- Input circuit response time, ON to OFF
- 0.4 ms or less (at 24 V DC)
- Input response time
- 1 ms, 1.5 ms, 5 ms, 10 ms, 20 ms, 50 ms, 70 ms
- Input reflection processing time
- Input circuit response time + input response time
- External power supply, Voltage
- 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC)
- External power supply, Current
- 140 mA (at 24 V DC)
- External power supply, Protection function
- External power supply overvoltage protection function
- Safety cycle time
- 2 ms
- Dielectric withstand voltage
- 510 V AC for 1 minute
- Insulation resistance
- 10 MΩ or higher by insulation resistance tester
- Noise immunity
- Noise voltage 500 Vp-p, noise width 1 µs, noise frequency 25...60 Hz (noise simulator condition)
- Protection degree
- IP2X
- External interface,
- 40 point 2-piece spring clamp terminal block
- Number of occupied I/O points
- 32 points (I/O assignment: Input 16 points)
- Internal current consumption (5 V DC)
- 260 mA (TYP. all points ON)
- Safety element
- Type B, HFT = 1, SC3
- External dimensions, Height
- 106 mm
Show all 45 specificationsShow fewer
- External dimensions, Width
- 27.8 mm
- External dimensions, Depth
- 129 mm
- Weight
- 0.21 kg
- Operating ambient temperature
- 0...55 ˚C (When an extended temperature range base unit is not used); 0...60 ˚C (When an extended temperature range base unit is used)
- Storage ambient temperature
- -25...75 ˚C
- Operating ambient humidity
- 5...95 %RH, non-condensing
- Storage ambient humidity
- 5...95 %RH, non-condensing
- Vibration resistance, Compliant with JIS B 3502 and IEC 61131-2, Under intermittent vibration
- Frequency: 5...8.4 Hz, Half amplitude: 3.5 mm; Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m/s 2 ; Sweep count: 10 times each in X, Y, Z directions
- Vibration resistance, Compliant with JIS B 3502 and IEC 61131-2, Under continuous vibration
- Frequency: 5...8.4 Hz, Half amplitude: 1.75 mm; Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m/s 2
- Shock resistance
- Compliant with JIS B 3502 and IEC 61131-2; (147 m/s 2 , 3 times each in X, Y, and Z bidirections)
- Operating atmosphere
- No corrosive gases, flammable gases, less conductive dust
- Operating altitude
- 0...2000 m
- Installation location
- Inside a control panel
- Overvoltage category
- II or less
- Pollution degree
- 2 or less
Technical documents (1)
Key features
- Input type: DC input (negative common type)
- Number of input points: 16 points (single wiring); 8 points (double wiring)
- Rated input current: Approx. 6.8 mA TYP. (at 24 V DC)
- ON voltage/ON current: 11 V or more/4 mA or more
- OFF voltage/OFF current: 5 V or less/1.5 mA or less
About the Mitsubishi Electric RX40NC6S-TS
The Mitsubishi Electric RX40NC6S-TS is a MELSEC iQ-R input module. Mitsubishi Electric's overview: Single wiring: 16 points, double wiring: 8 points, 24 V DC, Input response time: 1...70 ms, negative common, spring-clamp terminal block. Mitsubishi Electric lists it as on sale.
What is the RX40NC6S-TS used for?
The RX40NC6S-TS mounts on a MELSEC iQ-R base unit and connects field signals to the CPU, which reads or writes them each cycle.
Lifecycle and successor
Active.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the model name RX40NC6S-TS on the rating plate, with the serial number and function version. Send us a photo of the rating plate and we will confirm the details before quoting.
Alternatives for RX40NC6S-TS
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| Mitsubishi Electric RX40C7MELSEC iQ-R Input module, DC input: 16 points, 24 V DC 7 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX40C7-TSMELSEC iQ-R Input module, DC input: 16 points, 24 V DC 7 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX41C4MELSEC iQ-R Input module, DC input: 32 points, 24 V DC 4 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX41C4-TSMELSEC iQ-R Input module, DC input: 32 points, 24 V DC 4 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX42C4MELSEC iQ-R Input module, DC input: 64 points, 24 V DC 4 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX71C4MELSEC iQ-R Input module, 32 inputs | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX72C4MELSEC iQ-R Input module, 64 inputs | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX40PC6HMELSEC iQ-R Input module, DC input: 16 points, 24 V DC 6 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX40NC6HMELSEC iQ-R Input module, DC input: 16 points, 24 V DC 6 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX41C6HSMELSEC iQ-R Input module, DC input: 32 points, 24 V DC 6 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX61C6HSMELSEC iQ-R Input module, DC input: 32 points, 5 V DC 6 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
| Mitsubishi Electric RX40NC6BMELSEC iQ-R Input module, DC input: 16 points, 24 V DC 6 mA | Mitsubishi Electric | Digital input module | Active | Same family | On Request | On request | View › |
You may also be interested in
Mitsubishi Electric
Mitsubishi Electric Q02CPU-A
View ›Mitsubishi Electric
Mitsubishi Electric Q02HCPU-A
View ›Mitsubishi Electric
Mitsubishi Electric Q06HCPU-A
View ›Mitsubishi Electric
Mitsubishi Electric Q04UDPVCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q06UDPVCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q13UDPVCPU
View ›
Mitsubishi Electric
Mitsubishi Electric Q26UDPVCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q02PHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q06PHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q12PHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q25PHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q12PRHCPU
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.