- Manufacturer
- Siemens
- Manufacturer part number
- 3RV2021-4DA10
- Product family
- SIRIUS 3RV2 Motor Protection Circuit Breakers
- Technical datasheet
- Data sheet
Specifications
| Attribute | Value |
|---|---|
| Type | Motor protection circuit breaker |
| Manufacturer lifecycle | Active |
| General technical data / Product equipment of circuit breaker for motor protection complete unit with protection device | Yes |
| General technical data / size of the circuit-breaker | S0 |
| General technical data / size of contactor can be combined company-specific | S00, S0 |
| General technical data / product function disconnector functionality | Yes |
| General technical data / product extension auxiliary switch | Yes |
| power loss [W] for rated value of the current / at AC in hot operating state | 10.5 W |
| power loss [W] for rated value of the current / at AC in hot operating state per pole | 3.5 W |
| General technical data / type of calculation of power loss current-dependent | quadratic |
| General technical data / insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| General technical data / surge voltage resistance rated value | 6 kV |
| maximum permissible voltage for protective separation / in networks with ungrounded star point between main and auxiliary circuit | 400 V |
| maximum permissible voltage for protective separation / in networks with grounded star point between main and auxiliary circuit | 400 V |
| protection class IP / on the front according to IEC 60529 | IP20 |
Show all 166 specificationsShow fewer specifications
| protection class IP / on the front | IP20 |
|---|---|
| protection class IP / of the terminal | IP20 |
| General technical data / shock resistance according to IEC 60068-2-27 | 25g / 11 ms |
| mechanical service life (operating cycles) / of the main contacts typical | 100 000 |
| mechanical service life (operating cycles) / of auxiliary contacts typical | 100 000 |
| General technical data / electrical endurance (operating cycles) typical | 100 000 |
| General technical data / reference code according to IEC 81346-2 | Q |
| General technical data / continuous current rated value | 25 A |
| General technical data / Substance Prohibitance (day/month/year) | 10/01/2009 |
| General technical data / Net Weight | 345.6 g |
| Ambient conditions / installation altitude at height above sea level maximum | 2 000 m |
| ambient temperature / during operation | -20 ... +60 °C |
| ambient temperature / during storage | -50 ... +80 °C |
| ambient temperature / during transport | -50 ... +80 °C |
| Ambient conditions / temperature compensation | -20 ... +60 °C |
| Ambient conditions / relative humidity during operation | 10 ... 95 % |
| number of poles for main current circuit | 3 |
| Main circuit / adjustable current response value current of the current- dependent overload release | 18 ... 25 A |
| type of voltage for main current circuit | AC |
| Main circuit / operating voltage / rated value | 690 V; 20 ... 690 V |
| operating voltage / at AC-3 rated value maximum | 690 V |
| operating voltage / at AC-3e rated value maximum | 690 V |
| Main circuit / operating frequency rated value | 50 ... 60 Hz |
| Main circuit / operational current rated value | 25 A |
| operational current / at AC-3 at 400 V rated value | 25 A |
| operational current / at AC-3e at 400 V rated value | 25 A |
| operating power / at AC-3 / at 230 V rated value | 5.5 kW |
| operating power / at AC-3 / at 400 V rated value | 11 kW |
| operating power / at AC-3 / at 500 V rated value | 15 kW |
| operating power / at AC-3 / at 690 V rated value | 22 kW |
| operating power / at AC-3e / at 230 V rated value | 5.5 kW |
| operating power / at AC-3e / at 400 V rated value | 11 kW |
| operating power / at AC-3e / at 500 V rated value | 15 kW |
| operating power / at AC-3e / at 690 V rated value | 22 kW |
| operating frequency / at AC-3 maximum | 15 1/h |
| operating frequency / at AC-3e maximum | 15 1/h |
| type of voltage for auxiliary and control circuit | AC/DC |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 0 |
| number of CO contacts for auxiliary contacts | 0 |
| product function / ground fault detection | No |
| product function / phase failure detection | Yes |
| Protective and monitoring functions / trip class | CLASS 10 |
| Protective and monitoring functions / design of the overload release | thermal |
| Protective and monitoring functions / protection function thermal overload protection (ANSI 49) | Yes |
| maximum short-circuit current breaking capacity (Icu) / at AC at 240 V rated value | 100 kA |
| maximum short-circuit current breaking capacity (Icu) / at AC at 400 V rated value | 55 kA |
| maximum short-circuit current breaking capacity (Icu) / at AC at 500 V rated value | 10 kA |
| maximum short-circuit current breaking capacity (Icu) / at AC at 690 V rated value | 4 kA |
| operating short-circuit current breaking capacity (Ics) at AC / at 240 V rated value | 100 kA |
| operating short-circuit current breaking capacity (Ics) at AC / at 400 V rated value | 25 kA |
| operating short-circuit current breaking capacity (Ics) at AC / at 500 V rated value | 5 kA |
| operating short-circuit current breaking capacity (Ics) at AC / at 690 V rated value | 2 kA |
| Protective and monitoring functions / response value current of instantaneous short-circuit trip unit | 325 A |
| full-load current (FLA) for 3-phase AC motor / at 480 V rated value | 25 A |
| full-load current (FLA) for 3-phase AC motor / at 600 V rated value | 25 A |
| yielded mechanical performance [hp] / for single-phase AC motor / at 110/120 V rated value | 2 hp |
| yielded mechanical performance [hp] / for single-phase AC motor / at 230 V rated value | 3 hp |
| yielded mechanical performance [hp] / for 3-phase AC motor / at 200/208 V rated value | 5 hp |
| yielded mechanical performance [hp] / for 3-phase AC motor / at 220/230 V rated value | 7.5 hp |
| yielded mechanical performance [hp] / for 3-phase AC motor / at 460/480 V rated value | 15 hp |
| UL/CSA ratings / UL File Number (CCN) | E47705 (NLRV, NLRV7), E156943 (NKJH, NKJH7) |
| Short-circuit protection / product function short circuit protection | Yes |
| design of the short-circuit trip design of the fuse link for IT network for short-circuit | magnetic |
| protection of the main circuit / at 400 V | gL/gG 63 A |
| protection of the main circuit / at 500 V | gL/gG 50 A |
| protection of the main circuit / at 690 V | gL/gG 50 A |
| Short-circuit protection / certificate of suitability according to ATEX directive 2014/34/EU | DMT 02 ATEX F 001 |
| Short-circuit protection / type of protection according to ATEX directive 2014/34/EU | Ex II (2) GD |
| Installation/ mounting/ dimensions / mounting position | any |
| Installation/ mounting/ dimensions / fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| Installation/ mounting/ dimensions / Mounting method of circuit breaker for Transformer protection, Generator protection and system protection optional standard bar mounting | Yes |
| Installation/ mounting/ dimensions / height | 97 mm |
| Installation/ mounting/ dimensions / width | 45 mm |
| Installation/ mounting/ dimensions / depth | 97 mm |
| required spacing / with side-by-side mounting / forwards | 0 mm |
| required spacing / with side-by-side mounting / backwards | 0 mm |
| required spacing / with side-by-side mounting / upwards | 50 mm |
| required spacing / with side-by-side mounting / downwards | 50 mm |
| required spacing / with side-by-side mounting / at the side | 0 mm |
| required spacing / for grounded parts / forwards | 0 mm |
| required spacing / for grounded parts / backwards | 0 mm |
| required spacing / for grounded parts / upwards | 50 mm |
| required spacing / for grounded parts / at the side | 30 mm |
| required spacing / for grounded parts / downwards | 50 mm |
| required spacing / for live parts / forwards | 0 mm |
| required spacing / for live parts / backwards | 0 mm |
| required spacing / for live parts / upwards | 50 mm |
| required spacing / for live parts / downwards | 50 mm |
| required spacing / for live parts / at the side | 30 mm |
| required spacing / for grounded parts at 400 V / downwards | 30 mm |
| required spacing / for grounded parts at 400 V / upwards | 30 mm |
| required spacing / for grounded parts at 400 V / at the side | 9 mm |
| required spacing / for live parts at 400 V / downwards | 30 mm |
| required spacing / for live parts at 400 V / upwards | 30 mm |
| required spacing / for live parts at 400 V / at the side | 9 mm |
| required spacing / for grounded parts at 500 V / downwards | 30 mm |
| required spacing / for grounded parts at 500 V / upwards | 30 mm |
| required spacing / for grounded parts at 500 V / at the side | 9 mm |
| required spacing / for live parts at 500 V / downwards | 30 mm |
| required spacing / for live parts at 500 V / upwards | 30 mm |
| required spacing / for live parts at 500 V / at the side | 9 mm |
| required spacing / for grounded parts at 690 V / downwards | 50 mm |
| required spacing / for grounded parts at 690 V / upwards | 50 mm |
| required spacing / for grounded parts at 690 V / backwards | 0 mm |
| required spacing / for grounded parts at 690 V / at the side | 30 mm |
| required spacing / for grounded parts at 690 V / forwards | 0 mm |
| required spacing / for live parts at 690 V / downwards | 50 mm |
| required spacing / for live parts at 690 V / upwards | 50 mm |
| required spacing / for live parts at 690 V / backwards | 0 mm |
| required spacing / for live parts at 690 V / at the side | 30 mm |
| required spacing / for live parts at 690 V / forwards | 0 mm |
| Connections/ Terminals / product component removable terminal for auxiliary and control circuit | No |
| type of electrical connection / for main current circuit | screw-type terminals |
| Connections/ Terminals / arrangement of electrical connectors for main current circuit | Top and bottom |
| type of connectable conductor cross-sections / for main contacts / solid or stranded | 2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²) |
| type of connectable conductor cross-sections / for main contacts / finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² |
| type of connectable conductor cross-sections / for AWG cables for main contacts | 2x (16 ... 12), 2x (14 ... 8) |
| connectable conductor cross-section for main contacts / solid or stranded | 1 ... 10 mm² |
| connectable conductor cross-section for main contacts / finely stranded with core end processing | 1 ... 10 mm² |
| Connections/ Terminals / AWG number as coded connectable conductor cross section for main contacts | 16 ... 8 |
| tightening torque / for main contacts with screw-type terminals | 2 ... 2.5 N·m |
| Connections/ Terminals / design of screwdriver shaft | Diameter 5 to 6 mm |
| Connections/ Terminals / size of the screwdriver tip | Pozidriv size 2 |
| design of the thread of the connection screw / for main contacts | M4 |
| product function suitable for safety function | Yes |
| suitability for use / safety-related switching on | No |
| suitability for use / safety-related switching OFF | Yes |
| Safety related data / service life maximum | 10 a |
| Safety related data / test wear-related service life necessary | Yes |
| proportion of dangerous failures / with low demand rate according to SN 31920 | 40 % |
| proportion of dangerous failures / with high demand rate according to SN 31920 | 50 % |
| Safety related data / B10 value with high demand rate according to SN 31920 | 5 000 |
| Safety related data / failure rate [FIT] with low demand rate according to SN 31920 ISO 13849 | 50 FIT |
| Safety related data / device type according to ISO 13849-1 | 3 |
| Safety related data / overdimensioning according to ISO 13849-2 necessary IEC 61508 | Yes |
| safety device type according to IEC 61508-2 | Type A |
| T1 value / for proof test interval or service life according to IEC 61508 | 10 a |
| Safety related data / protection class IP on the front according to IEC 60529 | IP20 |
| Safety related data / touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
| display version for switching status | Handle |
| Environmental Product Declaration / global warming potential [CO2 eq] / during manufacturing | 2.68 kg |
| Environmental Product Declaration / global warming potential [CO2 eq] / during sales | 0.143 kg |
| Environmental Product Declaration / global warming potential [CO2 eq] / during operation | 72.7 kg |
| Environmental Product Declaration / global warming potential [CO2 eq] / after end of life | -0.445 kg |
| Environmental Product Declaration / global warming potential [CO2 eq] / total | 75.078 kg |
| Approvals Certificates / Environment | General Product Approval |
| Approvals Certificates / General Product Approval | For use in hazard- ous locations |
| For use in hazardous locations / Type Test Certific- | Special Test Certific- |
| For use in hazardous locations / Type Test Certific- / ates/Test Report | ate |
| Approvals Certificates / Maritime application | other Miscellaneous Confirmation |
Description
The Siemens 3RV2021-4DA10 is a size S0 SIRIUS 3RV2 circuit breaker for motor protection. Siemens's data sheet gives an adjustable overload release of 18 ... 25 A, an instantaneous short-circuit release at 325 A, trip class CLASS 10, a short-circuit breaking capacity (Icu) of 55 kA at 400 V AC and screw terminals. SiePortal lists it as an active product.
Application: Motor protection
Used with: SIRIUS 3RT2 contactors, size S0
What is the 3RV2021-4DA10 used for?
It protects and isolates a three-phase motor whose rated current falls in the 18 ... 25 A range, usually combined with a 3RT2 contactor of the same size in a motor starter.
Key features
- Size S0, 3-pole
- Adjustable overload release 18 ... 25 A
- Instantaneous short-circuit release 325 A
- Breaking capacity 55 kA at 400 V AC
- Trip class CLASS 10
- Screw terminals
Documents and Resources
Associated Products
| Image | Product | Description | Stock | View | Add to RFQ |
|---|---|---|---|---|---|
![]() | 3RV2011-1JA10Siemens | Motor protection circuit breaker S00, 7 ... 10 A, CLASS 10 | In stock | View | |
![]() | 3RV2021-4AA10Siemens | Motor protection circuit breaker S0, 10 ... 16 A, CLASS 10 | In stock | View | |
![]() | 3RV2021-4BA10Siemens | Motor protection circuit breaker S0, 13 ... 20 A, CLASS 10 | In stock | View |
Product Questions
Is the 3RV2021-4DA10 discontinued?
No. Its manufacturer lifecycle status is Active.
Can another Siemens SIRIUS 3RV2 motor protection circuit breakers part replace it?
Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.
Do you ship worldwide?
Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.
Latest news
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.