Woodward 5437-672

Field termination module for actuator-controller wiring in documented Woodward MicroNet configurations

Woodward
Illustration of a Woodward extension and i/o module; not a photograph of 5437-672

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Woodward 5437-672 provides field termination for actuator-controller wiring. The 5009FT MicroNet+ TMR manual lists it with the optional 5501-432 two-channel actuator controller and 5417-041 cable. Select a replacement against the installed controller, cable and wiring drawings.

Manufacturer
Woodward
Manufacturer part no.
5437-672
Type
Field termination module
Lifecycle
To be confirmed
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Woodward
Manufacturer part no.
5437-672
Type
Field termination module
Application
Maintenance of actuator-control field wiring in a documented Woodward turbine-control installation.
Used with
See the source-linked controller and cable pairings. Confirm the installed system and revision before ordering.
Product type
Actuator-controller field termination module (FTM)
Documented system
5009FT MicroNet+ TMR control system
Associated actuator-controller module
5501-432, two-channel controller; optional configuration
Cable in documented system layout
5417-041, 12 ft; optional configuration
Additional catalogue-listed driver pairings
5501-1428, 5501-1429, 5501-1430, 5501-1431 and 5501-1432
Cable selection reference for listed drivers
Table K

Technical documents (1)

Key features

  • Actuator field-wiring termination
  • Identified in Woodward system and industrial product documentation
  • Documented controller and cable pairings provided for selection

About the Woodward 5437-672

The Industrial Turbine Products Catalog also lists this FTM against five bipolar actuator-driver variants. Those pairings are configuration references; the driver output-current ratings are not standalone specifications of the FTM.

What is the 5437-672 used for?

Maintenance of actuator-control field wiring in a documented Woodward turbine-control installation.

Lifecycle and successor

To be confirmed.

Before you order

What to photograph or confirm so the right unit is quoted.

Confirm the complete 5437-672 part number, hardware revision and nameplate. Provide photographs of the existing assembly, connectors and terminal wiring. Confirm the associated actuator-controller module, cable part number and length. Check channel assignment, mounting and the approved system wiring drawing. State quantity, required condition and delivery date.

Other parts in the Woodward MicroNet and NetCon field termination hardware family

No other part in this family is recorded yet. Ask us about alternatives.

You may also be interested in

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Woodward 5437-672? Send us the details.