Skip to content
Industrial

1756-L72S

Allen-Bradley GuardLogix 5572S controller, 4 MB user memory

Allen-Bradley
Allen-Bradley 1756-L72S Logix 5572S Automation Controller 4M/2M, Rockwell Automation product photo

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Allen-Bradley 1756-L72S is a Logix 5572S automation controller with 4 MB user memory and 2 MB safety memory, offering standard and safety communication over EtherNet/IP, ControlNet and DeviceNet.

Manufacturer
Allen-Bradley
Manufacturer part no.
1756-L72S
Type
GuardLogix safety controller
Lifecycle
Active
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Allen-Bradley
Manufacturer part no.
1756-L72S
Type
GuardLogix safety controller
Application
PLC controller
Used with
ControlLogix 1756 chassis
Safety communication options
Standard and safety, EtherNet/IP, ControlNet, DeviceNet
Network connections per network module
1000 I/O; 528 EtherNet/IP; 512 TCP (1756-EN4TR) 256 EtherNet/IP; 128 TCP (1756-EN2x) 128 EtherNet/IP; 64 TCP (1756-ENBT) 128 ControlNet (1756-CN2/B) 100 ControlNet (1756-CN2/A) 40 ControlNet (1756-CNB/D, 1756-CNB/E)
Programming languages
For the safety task, GuardLogix controllers support Ladder Diagram only., For standard tasks, GuardLogix controllers support: – Ladder Diagram (LD) – Structured Text (ST) – Function Block Diagram (FBD) – Sequential Function Chart (SFC)
User memory
4 MB
Safety memory
2 MB
I/O memory
0.98 MB
Nonvolatile memory storage
1 GB Secure Digital (SD) card (1784-SD1), ships pre-installed in the controller
Digital I/O, max
128,000
Analog I/O, max
4000
Total I/O, max
128,000
Energy storage modules
1756-ESMCAP capacitor energy storage module (removable, ships installed with every controller) 1756-ESMNSE capacitor energy storage module (removable, no residual, WallClockTime power backup) 1756-ESMNRM capacitor energy storage module (non-removable, helps prevent USB connection and SD card use to help secure the controller)
Current draw @ 1.2V DC
5 mA
Current draw @ 5.1V DC
800 mA
Power dissipation
2.5 W
Thermal dissipation
8.5 BTU/hr
Isolation voltage
30V (continuous), basic insulation, USB port-to-system, Compliant and tested according to IEC/UL 61010-1
Weight, approx
0.25 kg (0.55 lb)
Slot width
2 (both modules needed; each is one slot)
Module location
Chassis-based, any slot
Chassis
1756-A4, 1756-A4K, 1756-A7, 1756-A7K, 1756-A10, 1756-A10K, 1756-A13, 1756-A13K, 1756-A17, 1756-A17K
Power supply, standard
1756-PA50, 1756-PA50K, 1756-PA72, 1756-PA72K, 1756-PA75, 1756-PA75K, 1756-PB50, 1756-PB50K 1756-PB72, 1756-PB72K, 1756-PB75, 1756-PB75K, 1756-PC75, 1756-PH75
Power supply, redundant
1756-PA75R, 1756-PA75RK, 1756-PB75R, 1756-PB75RK, 1756-PSCA2, 1756-PSCA2K
Wire category
3 - on USB ports
Temperature code
T4
Enclosure type rating
None (open-style)
Show all 40 specifications
Temperature, operating
0 °C ≤ Ta ≤ +60 °C (+32 °F ≤ Ta ≤ +140 °F)
Temperature, nonoperating
-40…+85 °C (-40…+185 °F)
Relative humidity
5…95% noncondensing
Vibration
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Shock, nonoperating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Emissions
IEC 61000-6-4
ESD immunity
IEC 61000-4-2
Radiated RF immunity
IEC 61000-4-3
Conducted RF Immunity
IEC 61000-4-6 (Not applicable: USB is a temporary programming port.)

Technical documents (1)

Key features

  • 4 MB user memory and 2 MB safety memory
  • 1 GB SD card ships pre-installed for nonvolatile storage
  • Up to 128,000 total I/O
  • Chassis-based, any slot, two modules of one slot each
  • Operating temperature 0 °C to +60 °C, open-style

About the Allen-Bradley 1756-L72S

The Allen-Bradley 1756-L72S is a Logix 5572S Automation Controller 4M/2M, listed by Rockwell Automation with the lifecycle status Active Mature. According to Rockwell technical data 1756-TD001, it has 4 MB user memory, 2 MB safety memory and 0.98 MB I/O memory. It supports up to 128,000 total I/O, of which up to 4000 can be analog, and ships with a pre-installed 1 GB SD card (1784-SD1). Rockwell gives its power dissipation as 2.5 W and its current draw as 800 mA at 5.1V DC.

What is the 1756-L72S used for?

Rockwell lists this GuardLogix controller for standard and safety control over EtherNet/IP, ControlNet and DeviceNet. For the safety task it supports Ladder Diagram only, while standard tasks can use Ladder Diagram, Structured Text, Function Block Diagram and Sequential Function Chart. It is chassis-based and fits any slot, and Rockwell states that both modules are needed, each taking one slot.

Lifecycle and successor

Active.

Before you order

What to photograph or confirm so the right unit is quoted.

Check that the catalog number on the module label reads 1756-L72S, and note the series letter and firmware revision printed on the same label. Send us a photo of the label if you want us to confirm the part before you order.

Alternatives for 1756-L72S

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
Allen-Bradley 1756-L71ControlLogix 2 MB controller with SD cardAllen-BradleyControlLogix controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L72ControlLogix 4 MB controller, 1-port USBAllen-BradleyControlLogix controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L73ControlLogix 8 MB controller, 1-port USBAllen-BradleyControlLogix controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L74ControlLogix 16 MB controller, USB portAllen-BradleyControlLogix controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L75ControlLogix 32 MB controller, USB portAllen-BradleyControlLogix controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L73XTControlLogix 8MB Controller L7XTAllen-BradleyControlLogix controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L71SLogix 5571S safety controller, 2 MB user memoryAllen-BradleyGuardLogix safety controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L73SLogix 5573S safety controller, 8 MB user memoryAllen-BradleyGuardLogix safety controllerActiveSame familyOn RequestOn requestView ›
Allen-Bradley 1756-L7SPLogix L7SP SIL 3 PLe safety partnerAllen-BradleySafety partner moduleActiveSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Allen-Bradley 1756-L72S? Send us the details.