Skip to content
Industrial

VLT 6122 525-600 V

Danfoss VLT 6000 HVAC type 6122, 90 kW, 3 x 525-600 V

Danfoss

Delivery options

  • FedEx
  • DHL
  • UPS

Danfoss VLT 6122 frequency converter from the VLT 6000 HVAC series for 3 x 525-600 V: 90 kW, output current 137 A at 525-550 V. Discontinued by Danfoss; successor iC7-HVACR.

Manufacturer
Danfoss
Manufacturer part no.
VLT 6122 525-600 V
Type
AC drive
Lifecycle
Discontinued
OEM successor
iC7-HVACR
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Danfoss
Manufacturer part no.
VLT 6122 525-600 V
Type
AC drive
Application
HVAC fan and pump speed control
Used with
Three-phase AC motors
Mains supply
3 x 525-600 V
Output current I VLT,N [A] (525-550 V)
137
Output current I VLT,MAX (60 s) [A] (525-550 V)
151
Output current I VLT,N [A] (551-600 V)
131
Output current I VLT,MAX (60 s) [A] (551-600 V)
144
Output S VLT,N [kVA] (550 V)
131
Output S VLT,N [kVA] (575 V)
130
Typical shaft output [kW] (550 V)
90
Typical shaft output [HP] (575 V)
125
Rated input current I L,N [A] (550 V)
130
Rated input current I L,N [A] (575 V)
124
Rated input current I L,N [A] (690 V)
128
Max. pre-fuses IEC/UL [A]
250
Efficiency
0.98
Power loss at max. load [W]
2532
Weight IP 00 [kg]
82
Weight IP 21 [kg]
96
Weight IP 54 [kg]
96

Technical documents (1)

Key features

  • 90 kW typical shaft output
  • Output current 137 A at 525-550 V
  • Mains supply 3 x 525-600 V
  • Discontinued by Danfoss; successor iC7-HVACR

About the Danfoss VLT 6122 525-600 V

The Danfoss VLT 6122 is a 90 kW frequency converter from the VLT 6000 HVAC series for 3 x 525-600 V supplies. Danfoss's VLT 6000 HVAC design guide gives it an output current of 137 A at 525-550 V; the full electrical data from the design guide is listed below. Danfoss's product page states that the VLT 6000 has reached the Inactive phase of its lifecycle, meaning it is discontinued and no longer in production, and names iC7-HVACR as its successor.

What is the VLT 6122 525-600 V used for?

It controls the speed of fans, pumps and compressors in building HVAC systems: air handling units, cooling towers, chilled- and hot-water pumps. A failed unit stops the fan or pump it drives.

Lifecycle and successor

Discontinued.

OEM successor: iC7-HVACR

Before you order

What to photograph or confirm so the right unit is quoted.

Read the full type code on the drive's label (it starts VLT6122, followed by the voltage, enclosure, filter, display and option codes) and send it complete: the options differ between otherwise identical 6122 units.

Alternatives for VLT 6122 525-600 V

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
iC7-HVACRNamed by the manufacturer as the successorDanfossAC driveNot checked; ask usOEM successor (upgrade path)On RequestOn requestView ›
Danfoss VLT 6002 200-240 VVLT 6000 HVAC type 6002, 1.1 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6003 200-240 VVLT 6000 HVAC type 6003, 1.5 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6004 200-240 VVLT 6000 HVAC type 6004, 2.2 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6005 200-240 VVLT 6000 HVAC type 6005, 3.0 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6006 200-240 VVLT 6000 HVAC type 6006, 4.0 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6008 200-240 VVLT 6000 HVAC type 6008, 5.5 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6011 200-240 VVLT 6000 HVAC type 6011, 7.5 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6016 200-240 VVLT 6000 HVAC type 6016, 11 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6022 200-240 VVLT 6000 HVAC type 6022, 15 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6027 200-240 VVLT 6000 HVAC type 6027, 18.5 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6032 200-240 VVLT 6000 HVAC type 6032, 22 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 6042 200-240 VVLT 6000 HVAC type 6042, 30 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.