Read from the product label
- Maker
- Danfoss
- Part no.
- VLT 8452 380-480 V
- Serial / rev.
- as printed on your unit
Image is for illustrative purposes only. Please refer to product description.
Delivery options
Danfoss VLT 8452 frequency converter from the VLT 8000 AQUA series for 3 x 380-480 V: 315 kW, output current 600 A at 380-440 V. Discontinued by Danfoss; successor iC7-Aqua.
- Manufacturer
- Danfoss
- Manufacturer part no.
- VLT 8452 380-480 V
- Product family
- VLT 8000 AQUA Frequency Converters
- Type
- AC drive
- Lifecycle
- Discontinued
- OEM successor
- iC7-Aqua
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Danfoss
- Manufacturer part no.
- VLT 8452 380-480 V
- Type
- AC drive
- Application
- Water and wastewater pump and blower speed control
- Used with
- Three-phase AC motors
- Mains supply
- 3 x 380-480 V
- Output current I VLT,N [A] (380-440 V)
- 600
- Output current I VLT,MAX (60 s) [A] (380-440 V)
- 660
- Output current I VLT,N [A] (441-480 V)
- 540
- Output current I VLT,MAX (60 s) [A] (441-480 V)
- 594
- Output S VLT,N [kVA] (400 V)
- 416
- Output S VLT,N [kVA] (480 V)
- 430
- Typical shaft output [kW] (380-440 V)
- 315
- Typical shaft output [HP] (441-480 V)
- 450
- Efficiency
- 0.98
- Power loss at max. load [W]
- 7630
Technical documents (1)
Key features
- 315 kW typical shaft output
- Output current 600 A at 380-440 V
- Mains supply 3 x 380-480 V
- Discontinued by Danfoss; successor iC7-Aqua
About the Danfoss VLT 8452 380-480 V
The Danfoss VLT 8452 is a 315 kW frequency converter from the VLT 8000 AQUA series for 3 x 380-480 V supplies. Danfoss's VLT 8000 AQUA design guide gives it an output current of 600 A at 380-440 V; the full electrical data from the design guide is listed below. Danfoss's product page states that the VLT 8000 has reached the Inactive phase of its lifecycle, meaning it is discontinued and no longer in production, and names iC7-Aqua as its successor.
What is the VLT 8452 380-480 V used for?
It controls the speed of pumps and blowers in water and wastewater plants: booster and borehole pumps, lift stations, aeration blowers. A failed unit stops the pump or blower it drives.
Lifecycle and successor
Discontinued.
OEM successor: iC7-Aqua
Before you order
What to photograph or confirm so the right unit is quoted.
Read the full type code on the drive's label (it starts VLT8452, followed by the voltage, enclosure, filter, display and option codes) and send it complete: the options differ between otherwise identical 8452 units.
Alternatives for VLT 8452 380-480 V
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| iC7-AquaNamed by the manufacturer as the successor | Danfoss | AC drive | Not checked; ask us | OEM successor (upgrade path) | On Request | On request | View › |
| Danfoss VLT 8006 200-240 VVLT 8000 AQUA type 8006, 4.0 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8008 200-240 VVLT 8000 AQUA type 8008, 5.5 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8011 200-240 VVLT 8000 AQUA type 8011, 7.5 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8016 200-240 VVLT 8000 AQUA type 8016, 11 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8022 200-240 VVLT 8000 AQUA type 8022, 15 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8027 200-240 VVLT 8000 AQUA type 8027, 18.5 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8032 200-240 VVLT 8000 AQUA type 8032, 22 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8042 200-240 VVLT 8000 AQUA type 8042, 30 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8052 200-240 VVLT 8000 AQUA type 8052, 37 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8062 200-240 VVLT 8000 AQUA type 8062, 45 kW, 3 x 200-240 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8006 380-480 VVLT 8000 AQUA type 8006, 4.0 kW, 3 x 380-480 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
| Danfoss VLT 8008 380-480 VVLT 8000 AQUA type 8008, 5.5 kW, 3 x 380-480 V | Danfoss | AC drive | Discontinued | Same family | On Request | On request | View › |
You may also be interested in
Danfoss
Danfoss NXL00022
View ›Danfoss
Danfoss NXL00032
View ›Danfoss
Danfoss NXL00042
View ›Danfoss
Danfoss NXL00062
View ›Danfoss
Danfoss NXL00015
View ›Danfoss
Danfoss NXL00025
View ›Danfoss
Danfoss NXL00035 IP20
View ›Danfoss
Danfoss NXL00045 IP20
View ›Danfoss
Danfoss NXL00055 IP20
View ›Danfoss
Danfoss NXL00035 IP21/IP54
View ›Danfoss
Danfoss NXL00045 IP21/IP54
View ›Danfoss
Danfoss NXL00055 IP21/IP54
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.