Schneider Electric Controller M221 24 IO relay

Schneider Electric
Schneider Electric TM221C24R controller M221 24 IO relay, Schneider Electric product photo

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Schneider Electric TM221C24R is a Modicon M221 logic controller with 24 discrete I/O, 100...240 V AC supply and relay normally open outputs.

Manufacturer
Schneider Electric
Manufacturer part no.
TM221C24R
Type
Modicon M221 logic controller
Lifecycle
Active
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Schneider Electric
Manufacturer part no.
TM221C24R
Type
Modicon M221 logic controller
Application
PLC controller
Used with
Modicon TM3 expansion modules
Range of product
Modicon M221
Product or component type
Logic controller
[Us] rated supply voltage
100...240 V AC
Discrete input number
14, discrete input conforming to IEC 61131-2 Type 1
Analogue input number
2 at 0...10 V
Discrete output type
Relay normally open
Discrete output number
10 relay
Discrete output voltage
5...125 V DC; 5...250 V AC
Discrete output current
2 A
Discrete I/O number
24
Maximum number of I/O expansion module
7 (local I/O-Architecture); 14 (remote I/O-Architecture)
Supply voltage limits
85…264 V
Network frequency
50/60 Hz
Inrush current
40 A
Maximum power consumption in VA
55 VA at 100...240 V with max number of I/O expansion module; 32 VA at 100...240 V without I/O expansion module
Power supply output current
0.52 A 5 V for expansion bus; 0.16 A 24 V for expansion bus
Discrete input logic
Sink or source (positive/negative)
Discrete input voltage
24 V
Discrete input voltage type
DC
Analogue input resolution
10 bits
LSB value
10 mV
Conversion time
1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs
+/- 30 V DC for 5 min (maximum) for analog input; +/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed
>= 15 V for input
Voltage state 0 guaranteed
<= 5 V for input
Show all 91 specifications
Discrete input current
7 mA for discrete input; 5 mA for fast input
Input impedance
3.4 kOhm for discrete input; 100 kOhm for analog input; 4.9 kOhm for fast input
Response time
35 µs turn-off, I2...I5 terminal(s) for input; 10 ms turn-on for output; 10 ms turn-off for output; 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input; 35 µs turn-on, other terminals terminal(s) for input; 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input; 100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time
0 ms for input; 3 ms for input; 12 ms for input
Output voltage limits
125 V DC; 277 V AC
Maximum current per output common
4 A at COM 2; 7 A at COM 0; 7 A at COM 1
Absolute accuracy error
+/- 1 % of full scale for analog input
Electrical durability
100000 cycles AC-12, 120 V, 240 VA, resistive; 100000 cycles AC-12, 240 V, 480 VA, resistive; 300000 cycles AC-12, 120 V, 80 VA, resistive; 300000 cycles AC-12, 240 V, 160 VA, resistive; 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive; 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive; 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive; 300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive; 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive; 100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive; 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive; 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive; 100000 cycles DC-12, 24 V, 48 W, resistive; 300000 cycles DC-12, 24 V, 16 W, resistive; 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms); 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency
20 switching operations/minute with maximum load
Mechanical durability
20000000 cycles for relay output
Minimum load
1 mA at 5 V DC for relay output
Protection type
Without protection at 5 A
Reset time
1 s
Memory capacity
256 kB for user application and data RAM with 10000 instructions; 256 kB for internal variables RAM
Data backed up
256 kB built-in flash memory for backup of application and data
Data storage equipment
2 GB SD card (optional)
Battery type
BR2032 or CR2032X lithium non-rechargeable
Backup time
1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction
0.3 ms for event and periodic task
Execution time per instruction
0.2 µs Boolean
Exct time for event task
60 µs response time
Maximum size of object areas
255 %C counters; 8000 %MW memory words; 512 %M memory bits; 512 %KW constant words; 255 %TM timers
Realtime clock
With
Clock drift
<= 30 s/month at 25 °C
Regulation loop
Adjustable PID regulator up to 14 simultaneous loops
Counting input number
4 fast input (HSC mode) at 100 kHz 32 bits
counter function
A/B; Single phase; Pulse/direction
Integrated connection type
USB port with mini B USB 2.0 connector; Non isolated serial link serial 1 with RJ45 connector and RS485 interface; Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
Supply
(serial)serial link supply: 5 V, <200 mA
Transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 480 Mbit/s for USB
Communication port protocol
USB port: USB - SoMachine-Network; Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Local signalling
1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED (green) for SL1; 1 LED (green) for SL2; 1 LED per channel (green) for I/O state
Electrical connection
removable screw terminal block for inputs; removable screw terminal block for outputs; terminal block, 3 terminal(s) for connecting the 24 V DC power supply; connector, 4 terminal(s) for analogue inputs; Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devices
Shielded cable: <10 m for fast input; Unshielded cable: <30 m for output; Unshielded cable: <30 m for digital input; Unshielded cable: <1 m for analog input
Insulation
Between input and internal logic at 500 V AC; Non-insulated between analogue input and internal logic; Non-insulated between analogue inputs; Between supply and ground at 1500 V AC; Between sensor power supply and ground at 500 V AC; Between input and ground at 500 V AC; Between output and ground at 1500 V AC; Between supply and internal logic at 2300 V AC; Between sensor power supply and internal logic at 500 V AC; Between output and internal logic at 2300 V AC; Between Ethernet terminal and internal logic at 500 V AC; Between supply and sensor power supply at 2300 V AC
Marking
CE
Sensor power supply
24 V DC at 250 mA supplied by the controller
Mounting support
Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
Height
90 mm
Depth
70 mm
Width
110 mm
Net weight
0.395 kg
Standards
IEC 61131-2; UL 508; CAN/CSA C22.2 No. 213; IACS E10; ANSI/ISA 12-12-01
Product certifications
LR; ABS; DNV-GL; RCM; cULus; EAC; CE; UKCA; cULus HazLoc
Resistance to electrostatic discharge
8 kV in air conforming to IEC 61000-4-2; 4 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3; 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields
30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients
2 kV (power lines) conforming to IEC 61000-4-4; 2 kV (relay output) conforming to IEC 61000-4-4; 1 kV (I/O) conforming to IEC 61000-4-4; 1 kV (Ethernet line) conforming to IEC 61000-4-4; 1 kV (serial link) conforming to IEC 61000-4-4
Surge withstand
2 kV power lines (AC) common mode conforming to IEC 61000-4-5; 2 kV relay output common mode conforming to IEC 61000-4-5; 1 kV I/O common mode conforming to IEC 61000-4-5; 1 kV shielded cable common mode conforming to IEC 61000-4-5; 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5; 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5; 1 kV relay output differential mode conforming to IEC 61000-4-5; 0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
Resistance to conducted disturbances
10 V 0.15...80 MHz conforming to IEC 61000-4-6; 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL); 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011; Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011; Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011; Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011; Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011; Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011; Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
Immunity to microbreaks
10 ms
Ambient air temperature for operation
-10…55 °C (horizontal installation); -10…35 °C (vertical installation)
Ambient air temperature for storage
-25…70 °C
Relative humidity
10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
IP degree of protection
IP20 with protective cover in place
Pollution degree
<= 2
Operating altitude
0...2000 m
Storage altitude
0…3000 m
Vibration resistance
3.5 mm at 5…8.4 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 1 gn at 8.4…150 Hz on symmetrical rail; 1 gn at 8.4…150 Hz on panel mounting
Shock resistance
98 m/s² for 11 ms

Technical documents (1)

Key features

  • Integrated connection type: USB port with mini B USB 2.0 connector
  • Communication port protocol: USB port: USB - SoMachine-Network
  • Discrete input number: 14, discrete input conforming to IEC 61131-2 Type 1
  • Discrete output number: 10 relay
  • Ambient air temperature for operation: 10…55 °C (horizontal installation); 10…35 °C (vertical installation)

About the Schneider Electric TM221C24R

The Schneider Electric TM221C24R is a logic controller from Schneider Electric's Modicon M221 range, which Schneider names "controller M221 24 IO relay". Its product page gives discrete I/O number 24 and rated supply voltage 100...240 V AC. Schneider Electric lists it as Active.

What is the TM221C24R used for?

The TM221C24R runs the control program for a machine, using its own built-in I/O and expansion modules for more I/O.

Lifecycle and successor

Active.

Before you order

What to photograph or confirm so the right unit is quoted.

Check the reference TM221C24R on the module's label, with its product version. Send us a photo of the label and we will confirm the details before quoting.

Alternatives for TM221C24R

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
Schneider Electric TM221C16RLogic controller, 16 inputs/outputs, 7 relay outputs, 100…240 V ACSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221C16TController M221 16 IO transistor PNPSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221C16ULogic controller, Modicon M221, 16io tr.npnSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221C24TController M221 24 IO transistor PNPSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221C24ULogic controller, Modicon M221, 24io tr.npnSchneider ElectricModicon M221 logic controllerDiscontinuedSame familyOn RequestOn requestView ›
Schneider Electric TM221C40RController M221 40 IO relaySchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221C40TController M221 40 IO transistor PNPSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221C40ULogic controller, Modicon M221, 40io tr.npnSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221CE16RController M221 16 IO relay EthernetSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221CE16TController M221 16 IO transistor PNP EthernetSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221CE16ULogic controller, Modicon M221, 16io tr.npn ethernetSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›
Schneider Electric TM221CE24RController M221 24 IO relay EthernetSchneider ElectricModicon M221 logic controllerActiveSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Schneider Electric TM221C24R? Send us the details.