Read from the product label
- Maker
- Allen-Bradley
- Part no.
- 1756-IF16
- Serial / rev.
- as printed on your unit
Image is for illustrative purposes only. Please refer to product description.
Delivery options
Allen-Bradley 1756-IF16 ControlLogix analog input module: 16 single ended, 8 differential or 4 high speed differential current or voltage inputs.
- Manufacturer
- Allen-Bradley
- Manufacturer part no.
- 1756-IF16
- Product family
- ControlLogix I/O Modules (1756)
- Type
- Analog input module
- Category
- PLCs and I/O › Analogue I/O modules
- Lifecycle
- Active
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Allen-Bradley
- Manufacturer part no.
- 1756-IF16
- Type
- Analog input module
- Application
- I/O module
- Used with
- ControlLogix 1756 chassis
- Inputs
- 16 single ended, 8 differential or 4 differential (high speed)
- Input range
- ±10V 0…10V 0…5V 0…20 mA
- Resolution
- 320 µV/count (15 bits + sign bipolar) @ ±10.25V 160 µV/count (16 bits) @ 0…10.25V 80 µV/count (16 bits) @ 0…5.125V 0.32 µA/count (16 bits) @ 0…20.5 mA
- Current draw @ 5.1V
- 200 mA
- Current draw @ 24V
- 35 mA
- Total backplane power
- 1.86 W
- Voltage and current ratings
- Backplane: 5.1V DC, 200 mA max 24V DC, 35 mA max, Input Voltage Range: -10…+10V, Input Current Range: 0…20mA, Limited to 100VA
- Power consumption
- 2.33 W
- Power dissipation
- Voltage: 1.86 W, Current: 3.53 W
- Thermal dissipation
- Voltage: 6.35 BTU/hr, Current: 12.06 BTU/hr
- Open circuit detection time
- Differential current or differential voltage: Positive full-scale reading within 5 s, Single-ended current or single-ended voltage: Even-numbered channels go to positive full scale reading within 5 s, odd-numbered channels go to negative full scale reading within 5 s
- Overvoltage protection, max
- Voltage: 30V DC, Current: 8V DC
- Normal mode noise rejection
- >80 dB @ 50/60 Hz
- Common mode noise rejection
- >100 dB @ 50/60 Hz
- Channel bandwidth
- 15 Hz (-3 dB)
- Calibrated accuracy 25 °C (77 °F)
- Voltage: Better than 0.05% of range, Current: Better than 0.15% of range
- Offset drift
- 45 µV/°C
- Gain drift with temperature
- Voltage: 15 ppm/°C, Current: 20 ppm/°C
- Module error
- Voltage: 0.1% of range, Current: 0.3% of range
- Module input scan time, min
- 16 pt single-ended: 16…488 ms 8 pt differential: 8…244 ms 4 pt differential: 5…122 ms
- Onboard data alarming
- Yes
- Data format
- Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
- Module conversion method
- Sigma-Delta
- Isolation voltage
- 250V (continuous), Basic insulation type, Inputs-to-Backplane. No isolation between individual Inputs.
- Module keying
- Electronic, software configurable
Show all 47 specificationsShow fewer
- RTB keying
- User-defined mechanical
- Slot width
- 1
- Terminal block torque specs
- 1756-TBCH 0.5 Nm (4.4 lbin)
- Wire category
- 2 - on signal ports
- Enclosure type
- None (open-style)
- Temperature code
- T4
- Temperature, operating
- 0 °C ≤ Ta ≤ +60 °C (+32 °F ≤ Ta ≤ +140 °F)
- Temperature, nonoperating
- -40…+85 °C (-40…+185 °F)
- Relative humidity
- 5…95% noncondensing
- Vibration
- 2 g @ 10…500 Hz
- Shock, operating
- 30 g
- Emissions
- IEC 61000-6-4
- ESD immunity
- 6 kV contact discharges 8 kV air discharges
- Radiated RF immunity
- 10V/m with 1 kHz sine wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine wave 80% AM from 2000…2700 MHz
- EFT/B immunity
- ±2 kV at 5 kHz on signal ports
- Surge transient immunity
- ±2 kV line-earth (CM) on shielded ports
- Conducted RF immunity
- 10V rms with 1 kHz sine wave 80% AM from 150 kHz…80 MHz
Technical documents (1)
Key features
- Electronic keying, software configurable
- Onboard data alarming is available
- Integer or IEEE 32-bit floating point data
- 250V continuous isolation from inputs to backplane
- Open-style enclosure with 0 to 60 °C operation
About the Allen-Bradley 1756-IF16
The 1756-IF16 is a ControlLogix 16 point analog input module for current and voltage (36 pin). Input ranges are ±10V, 0 to 10V, 0 to 5V and 0 to 20 mA, with 16 bit resolution on the unipolar ranges and 15 bits plus sign on the bipolar range. Calibrated accuracy at 25 °C is better than 0.05% of range for voltage and 0.15% of range for current, with a channel bandwidth of 15 Hz (-3 dB). It is one slot wide.
What is the 1756-IF16 used for?
It reads current or voltage signals from field transmitters into a ControlLogix system, using Sigma-Delta conversion, and returns data in integer mode or as IEEE 32-bit floating point. It draws 200 mA at 5.1V and 35 mA at 24V from the backplane, with 250V continuous basic insulation between inputs and backplane.
Lifecycle and successor
Active (Rockwell Automation lifecycle status, checked 24 October 2026).
Before you order
What to photograph or confirm so the right unit is quoted.
Read the catalog number 1756-IF16, the series letter and the firmware revision from the label. Send us a photo of the label and we confirm the match before we quote.
Other parts in the Allen-Bradley ControlLogix I/O Modules family
Listed for reference. They differ from the 1756-IF16 in rating, supply, interface or function and are not interchangeable with it unless Allen-Bradley says so. Match the part number on your unit.
| Product | Type | Lifecycle | Qty Available | Price | Action |
|---|---|---|---|---|---|
| Allen-Bradley 1756-OW16IControlLogix 16 Point Isolated Relay Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-IA16ControlLogix 16 Point 120V AC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB16ControlLogix 16 Point 12/24V DC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB16IControlLogix 16 Point Isolated 24V DC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB16SControl Logix Safety IO Module, 16 Sinking Inputs | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB32ControlLogix 32 Point 12/24V DC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IF16HControlLogix 16 Point HART Analog Input Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-IF6IControlLogix 6 Point Isolated Analogue Input Module | Analog input module | Discontinued | On request | On request | View |
| Allen-Bradley 1756-IF8ControlLogix 8 Point A/I Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-IF8IControlLogix 8 Point Isolated Analog Input Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-IRT8IControlLogix 8 Point RTD/Thermocouple Input Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-OA16ControlLogix 16 Point 74-265 VAC Output Module | Digital output module | Active | On request | On request | View |
You may also be interested in
- In stock

Allen-Bradley
Allen-Bradley 1756-CN2R
View 
Allen-Bradley
Allen-Bradley 1756-CN2RXT
View
Allen-Bradley
Allen-Bradley 1756-CNB
View
Allen-Bradley
Allen-Bradley 1756-CNBR
View
Allen-Bradley
Allen-Bradley 1756-DNB
View
Allen-Bradley
Allen-Bradley 1756-EN2F
View- In stock

Allen-Bradley
Allen-Bradley 1756-EN2T
View 
Allen-Bradley
Allen-Bradley 1756-EN2TR
View
Allen-Bradley
Allen-Bradley 1756-EN2TXT
View
Allen-Bradley
Allen-Bradley 1756-EN3TR
View
Allen-Bradley
Allen-Bradley 1756-ENBT
View
Allen-Bradley
Allen-Bradley 1756-EWEB
View
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.