Skip to content

Allen-Bradley 1756-OA16

ControlLogix 16 Point 74-265 VAC Output Module

Allen-Bradley
Allen-Bradley 1756-OA16 ControlLogix 16 Point D/O Module, Rockwell Automation product photo

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Allen-Bradley 1756-OA16 ControlLogix AC output module: 16 outputs at 74-265 VAC in fused groups of eight, 0.5 A per point at 60 °C.

Manufacturer
Allen-Bradley
Manufacturer part no.
1756-OA16
Type
Digital output module
Lifecycle
Active
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Allen-Bradley
Manufacturer part no.
1756-OA16
Type
Digital output module
Application
I/O module
Used with
ControlLogix 1756 chassis
Time stamp of diagnostics
±1 ms
Fuse blown
One fuse and indicator/group
Outputs
16 mechanically fused/group (8 points/group)
Pilot duty
0.5 A
Voltage category
120/240V AC 50/60 Hz
Operating voltage range
74…265V AC 47…63 Hz
Output delay time
9.3 ms @ 60 Hz 11 ms @ 50 Hz 9.3 ms @ 60 Hz 11 ms @ 50 Hz
Current draw @ 5.1V
400 mA
Current draw @ 24V
2 mA
Total backplane power
2.1 W
Power dissipation, max
6.5 W @ 60 °C (140 °F)
Thermal dissipation
22.17 BTU/hr
Off-state leakage current, max
3 mA per point
On-state voltage drop, max
1.5V @ 0.5 A 5.7V @ load current < 50 mA
Current per point, max
0.5 A @ 60 °C (140 °F)
Current per group, max
2 A @ 60 °C (140 °F)
Current per module, max
4 A @ 60 °C (140 °F)
Surge current per point
5 A for 43 ms per point, repeatable every 2 s @ 60 °C (140 °F)
Surge current per group
15 A for 43 ms per group, repeatable every 2 s @ 60 °C (140 °F)
Load current, min
10 mA per point
Commutating voltage
4V/µs for loads > 50 mA 0.2V/µs for loads < 50 mA
Scheduled outputs
Synchronization within 16.7 s max, reference to the Coordinated System Time
States in Fault mode per point
Hold last state, On or Off (Off is default)
Isolation voltage
250V (continuous), basic insulation type, outputs to backplane, and group to group
Inhibit voltage, max
Zero crossing 60V peak
Show all 50 specifications
Module keying
Electronic, software configurable
Fusing
Mechanically fused/group, 3.15 A @ 250V AC slow blow, 1500 A interruption current, Littelfuse p/n H2153.15
RTB keying
User-defined mechanical
Slot width
1
Wire size
11756-TBNH, Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max., Double wire connection: 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max. 1756-TBSH, Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max.
Wire category
1 - on signal ports
Enclosure type
None (open style)
North American temperature code
T4
Temperature, operating
0…60 °C (32…140 °F)
Temperature, nonoperating
-40…+85 °C (-40…+185 °F)
Relative humidity
5…95% noncondensing
Vibration
2 g @ 10…500 Hz
Shock, operating
30 g
Shock, nonoperating
50 g
Emissions
IEC 61000-6-4
ESD immunity
6 kV contact discharges 8 kV air discharges
Radiated RF immunity
10V/m with 1 kHz sine wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine wave 80% AM from 2000…2700 MHz
EFT/B immunity
±4 kV at 5 kHz on signal ports
Surge transient immunity
±1 kV line-line (DM) and ±2 kV line-earth (CM) on signal ports
Conducted RF immunity
10V rms with 1 kHz sine wave 80% AM from 150 kHz…80 MHz

Technical documents (1)

Key features

  • 16 outputs in groups of 8 points
  • One fuse and indicator per group
  • Electronic keying, software configurable
  • Hold last state, on or off in fault mode
  • Time stamp of diagnostics within ±1 ms

About the Allen-Bradley 1756-OA16

The 1756-OA16 is a ControlLogix 16 point AC output module (74-265 VAC Output 16 Pts, 20 pin). It works from 74…265V AC at 47…63 Hz, with a maximum of 0.5 A per point, 2 A per group and 4 A per module at 60 °C (140 °F). Each group is mechanically fused with a 3.15 A, 250V AC slow blow fuse, Littelfuse p/n H2153.15.

What is the 1756-OA16 used for?

It switches 120/240V AC 50/60 Hz loads, such as contactors and solenoids, from a ControlLogix controller on 16 output points. Scheduled outputs synchronise to the Coordinated System Time. In fault mode each point can hold its last state or go On or Off, with Off as the default.

Lifecycle and successor

Active (Rockwell Automation lifecycle status, checked 24 October 2026).

Before you order

What to photograph or confirm so the right unit is quoted.

Read the catalog number 1756-OA16, the series letter and the firmware revision from the label. Send us a photo of the label and we confirm the match before we quote.

Other parts in the Allen-Bradley ControlLogix I/O Modules family

Listed for reference. They differ from the 1756-OA16 in rating, supply, interface or function and are not interchangeable with it unless Allen-Bradley says so. Match the part number on your unit.

ProductTypeLifecycleQty AvailablePriceAction
Allen-Bradley 1756-OW16IControlLogix 16 Point Isolated Relay Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-IF16HControlLogix 16 Point HART Analog Input ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-IF6IControlLogix 6 Point Isolated Analogue Input ModuleAnalog input moduleDiscontinuedOn requestOn requestView
Allen-Bradley 1756-IF8ControlLogix 8 Point A/I ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-IF8IControlLogix 8 Point Isolated Analog Input ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-IRT8IControlLogix 8 Point RTD/Thermocouple Input ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-OA16IControlLogix 16 Point Isolated AC Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OB16DControlLogix 16 Point 24V DC Diagnostic Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OB16EControlLogix 16 Point Fused DC Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OB32ControlLogix 32 Point 12/24V DC Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OF8ControlLogix 8 Point Analog Output ModuleAnalog output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OF8IControlLogix 8 Point Isolated Analog Output ModuleAnalog output moduleActiveOn requestOn requestView

You may also be interested in

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Allen-Bradley 1756-OA16? Send us the details.