Image is for illustrative purposes only. Please refer to product description.
Delivery options
Allen-Bradley 1756-OA16 ControlLogix AC output module: 16 outputs at 74-265 VAC in fused groups of eight, 0.5 A per point at 60 °C.
- Manufacturer
- Allen-Bradley
- Manufacturer part no.
- 1756-OA16
- Product family
- ControlLogix I/O Modules (1756)
- Type
- Digital output module
- Category
- PLCs and I/O › Digital I/O modules
- Lifecycle
- Active
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Allen-Bradley
- Manufacturer part no.
- 1756-OA16
- Type
- Digital output module
- Application
- I/O module
- Used with
- ControlLogix 1756 chassis
- Time stamp of diagnostics
- ±1 ms
- Fuse blown
- One fuse and indicator/group
- Outputs
- 16 mechanically fused/group (8 points/group)
- Pilot duty
- 0.5 A
- Voltage category
- 120/240V AC 50/60 Hz
- Operating voltage range
- 74…265V AC 47…63 Hz
- Output delay time
- 9.3 ms @ 60 Hz 11 ms @ 50 Hz 9.3 ms @ 60 Hz 11 ms @ 50 Hz
- Current draw @ 5.1V
- 400 mA
- Current draw @ 24V
- 2 mA
- Total backplane power
- 2.1 W
- Power dissipation, max
- 6.5 W @ 60 °C (140 °F)
- Thermal dissipation
- 22.17 BTU/hr
- Off-state leakage current, max
- 3 mA per point
- On-state voltage drop, max
- 1.5V @ 0.5 A 5.7V @ load current < 50 mA
- Current per point, max
- 0.5 A @ 60 °C (140 °F)
- Current per group, max
- 2 A @ 60 °C (140 °F)
- Current per module, max
- 4 A @ 60 °C (140 °F)
- Surge current per point
- 5 A for 43 ms per point, repeatable every 2 s @ 60 °C (140 °F)
- Surge current per group
- 15 A for 43 ms per group, repeatable every 2 s @ 60 °C (140 °F)
- Load current, min
- 10 mA per point
- Commutating voltage
- 4V/µs for loads > 50 mA 0.2V/µs for loads < 50 mA
- Scheduled outputs
- Synchronization within 16.7 s max, reference to the Coordinated System Time
- States in Fault mode per point
- Hold last state, On or Off (Off is default)
- Isolation voltage
- 250V (continuous), basic insulation type, outputs to backplane, and group to group
- Inhibit voltage, max
- Zero crossing 60V peak
Show all 50 specificationsShow fewer
- Module keying
- Electronic, software configurable
- Fusing
- Mechanically fused/group, 3.15 A @ 250V AC slow blow, 1500 A interruption current, Littelfuse p/n H2153.15
- RTB keying
- User-defined mechanical
- Slot width
- 1
- Wire size
- 11756-TBNH, Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max., Double wire connection: 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max. 1756-TBSH, Single wire connection: 0.33…2.1 mm2 (22…14 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max.
- Wire category
- 1 - on signal ports
- Enclosure type
- None (open style)
- North American temperature code
- T4
- Temperature, operating
- 0…60 °C (32…140 °F)
- Temperature, nonoperating
- -40…+85 °C (-40…+185 °F)
- Relative humidity
- 5…95% noncondensing
- Vibration
- 2 g @ 10…500 Hz
- Shock, operating
- 30 g
- Shock, nonoperating
- 50 g
- Emissions
- IEC 61000-6-4
- ESD immunity
- 6 kV contact discharges 8 kV air discharges
- Radiated RF immunity
- 10V/m with 1 kHz sine wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine wave 80% AM from 2000…2700 MHz
- EFT/B immunity
- ±4 kV at 5 kHz on signal ports
- Surge transient immunity
- ±1 kV line-line (DM) and ±2 kV line-earth (CM) on signal ports
- Conducted RF immunity
- 10V rms with 1 kHz sine wave 80% AM from 150 kHz…80 MHz
Technical documents (1)
Key features
- 16 outputs in groups of 8 points
- One fuse and indicator per group
- Electronic keying, software configurable
- Hold last state, on or off in fault mode
- Time stamp of diagnostics within ±1 ms
About the Allen-Bradley 1756-OA16
The 1756-OA16 is a ControlLogix 16 point AC output module (74-265 VAC Output 16 Pts, 20 pin). It works from 74…265V AC at 47…63 Hz, with a maximum of 0.5 A per point, 2 A per group and 4 A per module at 60 °C (140 °F). Each group is mechanically fused with a 3.15 A, 250V AC slow blow fuse, Littelfuse p/n H2153.15.
What is the 1756-OA16 used for?
It switches 120/240V AC 50/60 Hz loads, such as contactors and solenoids, from a ControlLogix controller on 16 output points. Scheduled outputs synchronise to the Coordinated System Time. In fault mode each point can hold its last state or go On or Off, with Off as the default.
Lifecycle and successor
Active (Rockwell Automation lifecycle status, checked 24 October 2026).
Before you order
What to photograph or confirm so the right unit is quoted.
Read the catalog number 1756-OA16, the series letter and the firmware revision from the label. Send us a photo of the label and we confirm the match before we quote.
Other parts in the Allen-Bradley ControlLogix I/O Modules family
Listed for reference. They differ from the 1756-OA16 in rating, supply, interface or function and are not interchangeable with it unless Allen-Bradley says so. Match the part number on your unit.
| Product | Type | Lifecycle | Qty Available | Price | Action |
|---|---|---|---|---|---|
| Allen-Bradley 1756-OW16IControlLogix 16 Point Isolated Relay Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-IF16HControlLogix 16 Point HART Analog Input Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-IF6IControlLogix 6 Point Isolated Analogue Input Module | Analog input module | Discontinued | On request | On request | View |
| Allen-Bradley 1756-IF8ControlLogix 8 Point A/I Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-IF8IControlLogix 8 Point Isolated Analog Input Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-IRT8IControlLogix 8 Point RTD/Thermocouple Input Module | Analog input module | Active | On request | On request | View |
| Allen-Bradley 1756-OA16IControlLogix 16 Point Isolated AC Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OB16DControlLogix 16 Point 24V DC Diagnostic Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OB16EControlLogix 16 Point Fused DC Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OB32ControlLogix 32 Point 12/24V DC Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OF8ControlLogix 8 Point Analog Output Module | Analog output module | Active | On request | On request | View |
| Allen-Bradley 1756-OF8IControlLogix 8 Point Isolated Analog Output Module | Analog output module | Active | On request | On request | View |
You may also be interested in
Allen-Bradley
Allen-Bradley 1762-IF2OF2
ViewAllen-Bradley
Allen-Bradley 1762-IF4
ViewAllen-Bradley
Allen-Bradley 1762-IQ16
ViewAllen-Bradley
Allen-Bradley 1762-OW16
ViewAllen-Bradley
Allen-Bradley 1768-ENBT
View
Allen-Bradley
Allen-Bradley 1769-HSC
ViewAllen-Bradley
Allen-Bradley 1769-IA16
ViewAllen-Bradley
Allen-Bradley 1769-IF4
ViewAllen-Bradley
Allen-Bradley 1769-IF8
View
Allen-Bradley
Allen-Bradley 1769-L16ER-BB1B
View
Allen-Bradley
Allen-Bradley 1769-L18ER-BB1B
View
Allen-Bradley
Allen-Bradley 1769-L24ER-QB1B
View
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.