Image is for illustrative purposes only. Please refer to product description.
Delivery options
Allen-Bradley 1756-OW16I ControlLogix relay output module: 16 normally open, individually isolated outputs, 5...125V DC or 10...240V AC, one slot wide.
- Manufacturer
- Allen-Bradley
- Manufacturer part no.
- 1756-OW16I
- Product family
- ControlLogix I/O Modules (1756)
- Type
- Digital output module
- Category
- PLCs and I/O › Digital I/O modules
- Lifecycle
- Active
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Allen-Bradley
- Manufacturer part no.
- 1756-OW16I
- Type
- Digital output module
- Application
- I/O module
- Used with
- ControlLogix 1756 chassis
- Isolation
- 250 V continuous between outputs
- Bounce time, mean
- 1.2 µs
- Conducted RF immunity
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
- Current draw
- 150mA @ 5.1V, 150mA @ 24V
- EFT/B immunity
- ±4kV @ 5kHz on signal ports
- Emissions
- IEC 61000-6-4
- Enclosure type
- None (open-style)
- ESD immunity
- 6 kV contact discharges, 8 kV air discharges
- Expected contact life
- 300 kHz, resistive, 100 kHz, inductive
- Fusing
- Not protected. A fused IFM can be used to help protect outputs. See publication 1492-TD008. However, the ControlLogix, system has been agency certified using only the ControlLogix RTBs, that is, 1756-TBCH, 1756-TBNH, 1756-TBSH, and, 1756-TBS6H. Any applic
- Initial contact resistance, max
- 100 mΩ @ 6V @ 1A
- Isolation voltage
- 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
- Load current per point, min
- 10 mA
- Module keying
- Electronic, software configurable
- Off-state leakage current per point, max
- 1.5 mA
- Operating temperature
- 0 to 60 °C
- Operating voltage
- 5...125V DC @ 10...240V AC
- Oscillatory surge withstand
- IEEE C37.90.1: 3kV
- Output delay time
- OFF to ON: 10 ms maximum, ON to OFF: 10 ms maximum
- Outputs
- 16 N.O. individually isolated
- Output voltage
- 1A @ 5...30V DC 0.5A @ 48V DC 0.22A @ 125V DC 1.5A @ 120V AC, 50/60 Hz 0.75A @ 240V AC, 50/60 Hz
- Pilot duty
- C300, R150
- Power dissipation, max
- 4.5 W @ 60 °C (140 °F)
- Radiated RF immunity
- 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
- Relative humidity
- 5...95% noncondensing
Show all 45 specificationsShow fewer
- RTB keying
- User-defined mechanical
- Scheduled outputs
- Synchronization within 16.7 s max, reference to the coordinated system time
- Shock
- Operating: 30 G, Non operating: 50 G
- Slot width
- 1
- States in fault mode per point
- Hold last state, On or Off (Off is default)
- States in program mode per point
- Hold last state, On or Off (Off is default)
- Surge transient immunity
- ±1 kV line-line (DM) and ±2 kV line-earth (CM) on signal ports
- Switching frequency, max
- 1 ops/3 s (0.3 Hz at rated load)
- Thermal dissipation
- 15.35 btu/h
- Total backplane power
- 4.4 W
- Type of digital output
- Relay
- Type of electric connection
- Screw connection
- Type of voltage (input voltage)
- DC
- Vibration
- 2 G @ 10...500 Hz
- Wire category
- Wire category: 1
Technical documents (1)
Key features
- 16 normally open outputs, individually isolated
- Electronic keying, software configurable
- User-defined mechanical RTB keying
- Program and fault mode: hold last state, On or Off
- Output delay of 10 ms maximum each way
About the Allen-Bradley 1756-OW16I
The 1756-OW16I is a ControlLogix 16 point relay output module (N.O. Isolated Relay Output 16 Pts, 36 pin). Each of its 16 normally open outputs is individually isolated, and it switches 5...125V DC or 10...240V AC. Outputs are rated 1A at 5...30V DC and 1.5A at 120V AC, 50/60 Hz. It occupies 1 slot and works from 0 to 60 °C.
What is the 1756-OW16I used for?
It switches field loads from a ControlLogix controller through relay contacts. In program mode and in fault mode each point can hold its last state, or go On or Off, with Off as the default. The maximum switching frequency is 1 ops/3 s (0.3 Hz at rated load).
Lifecycle and successor
Active (Rockwell Automation lifecycle status, checked 24 October 2026).
Before you order
What to photograph or confirm so the right unit is quoted.
Read the catalog number 1756-OW16I, the series letter and the firmware revision from the label. Send us a photo of the label and we confirm the match before we quote.
Other parts in the Allen-Bradley ControlLogix I/O Modules family
Listed for reference. They differ from the 1756-OW16I in rating, supply, interface or function and are not interchangeable with it unless Allen-Bradley says so. Match the part number on your unit.
| Product | Type | Lifecycle | Qty Available | Price | Action |
|---|---|---|---|---|---|
| Allen-Bradley 1756-IA16ControlLogix 16 Point 120V AC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB16ControlLogix 16 Point 12/24V DC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB16IControlLogix 16 Point Isolated 24V DC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB16SControl Logix Safety IO Module, 16 Sinking Inputs | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-IB32ControlLogix 32 Point 12/24V DC Input Module | Digital input module | Active | On request | On request | View |
| Allen-Bradley 1756-OA16ControlLogix 16 Point 74-265 VAC Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OA16IControlLogix 16 Point Isolated AC Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OB16DControlLogix 16 Point 24V DC Diagnostic Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OB16EControlLogix 16 Point Fused DC Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OB32ControlLogix 32 Point 12/24V DC Output Module | Digital output module | Active | On request | On request | View |
| Allen-Bradley 1756-OF8ControlLogix 8 Point Analog Output Module | Analog output module | Active | On request | On request | View |
| Allen-Bradley 1756-OF8IControlLogix 8 Point Isolated Analog Output Module | Analog output module | Active | On request | On request | View |
You may also be interested in
Allen-Bradley
Allen-Bradley 1756-L82EXTS
View- In stock
Allen-Bradley
Allen-Bradley 1756-L83EK
View 
Allen-Bradley
Allen-Bradley 1756-L83EP
View
Allen-Bradley
Allen-Bradley 1756-L83EPXT
View- In stock
Allen-Bradley
Allen-Bradley 1756-L83ES
View 
Allen-Bradley
Allen-Bradley 1756-L83ESXT
View
Allen-Bradley
Allen-Bradley 1756-L83EXT
View- In stock
Allen-Bradley
Allen-Bradley 1756-L83EXTS
View - In stock
Allen-Bradley
Allen-Bradley 1756-L84EK
View 
Allen-Bradley
Allen-Bradley 1756-L84ES
View- In stock

Allen-Bradley
Allen-Bradley 1756-L84ESXT
View 
Allen-Bradley
Allen-Bradley 1756-L84EXT
View
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.