Allen-Bradley 1756-OF8I ControlLogix analog output module: eight isolated points, each set for current or voltage, 16 bit resolution, one slot.

Manufacturer
Allen-Bradley
Manufacturer part no.
1756-OF8I
Type
Analog output module
Lifecycle
Active
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Allen-Bradley
Manufacturer part no.
1756-OF8I
Type
Analog output module
Application
I/O module
Used with
ControlLogix 1756 chassis
Display
Module Health, In Calibration,Mode, Input, Fault and,Communication Status
Isolation
250V (continuous), reinforced,insulation type, outputs to,backplane. 250V (continuous),basic insulation type, output,to output
Special Features
Per Point Isolation
Analogue inputs configurable
Yes
Calibrated accuracy
0.05% @ 25°C (77 °F)
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Current draw
200mA @ 5.1V, Voltage or current mode with 250 Ω loads = 220mA @ 24V, Current mode with 500 Ω loads = 275mA @ 24V, Current mode with 750 Ω loads = 340mA @ 24V, Current mode with 1000 Ω loads = 385mA @ 24V
Data format
IEEE 32-bit floating point
Drive capability
Current output = 0...1000 Ω, Voltage output =>1000 Ω
EFT/B immunity
±4kV @ 5kHz on signal ports
Emissions
IEC 61000-6-4
Enclosure type rating
None (open-style)
ESD immunity
6 kV contact discharges, 8 kV air discharges
Input, current
Yes
Inputs
Eight isolated channels - any combination of voltage or current mode
Input signal, configurable
Yes
Input, voltage
Yes
Isolation voltage
250V (continuous), reinforced insulation type, outputs to backplane, 250V (continuous), basic insulation type, output to output
Module conversion method
R-Ladder DAC, monotonicity with no missing codes
Module error over full temperature range
0.1 %
Module keying
Electronic, software configurable
Module scan time
1 ms minimum
Open circuit detection
Current output = Yes
Operating temperature
0 to 60 °C
Output impedance
46 Ω (Current output)
Show all 47 specifications
Output range
-10…10V, 0…10V, 0…5V, 0…20 Ma
Overvoltage protection
±30V DC (voltage/current)
Power dissipation
Voltage mode: 5.4 W (18.4 BTU/hr), Current mode with 250 Ω loads: 5.4 W (18.4 BTU/hr), Current mode with 500 Ω loads: 5.8 W (19.8 BTU/hr), Current mode with 750 Ω loads: 6.5 W (22.2 BTU/hr), Current mode with 1000 Ω loads: 6.7 W (22.9 BTU/hr)
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Relative humidity
5...95% noncondensing
Resolution
16 bit, ±10.5V (0.32 mV/count), 0...10.5V (0.16 mV/count), 0...5.25V (0.08 mV/count), 0...21 mA (0.32 µA/count)
RTB keying
User-defined mechanical
Settling time
<2 ms to 95% of final value with resistive loads
Shock
Operating: 30 G, Non operating: 50 G
Short circuit detection
Voltage output = Yes
Slot width
1
Surge transient immunity
±2 kV line-earth (CM) on shielded signal ports
Thermal dissipation
Voltage mode = 18.4 BTU/hr, Current mode with 250 Ω loads = 18.4 BTU/hr, Current mode with 500 Ω loads = 19.8 BTU/hr, Current mode with 750 Ω loads = 22.2 BTU/hr, Current mode with 1000 Ω loads = 22.9 BTU/hr
Total backplane power
Voltage mode = 6.3 W, Current mode with 250 Ω loads = 6.3 W, Current mode with 500 Ω loads = 7.6 W, Current mode with 750 Ω loads = 9.2 W, Current mode with 1000 Ω loads = 10.2 W
Vibration
2 G @ 10...500 Hz
Wire category
2 - on signal ports
Wire size
0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 90 °C (194 °F) or greater, 1.2 mm (3/64 in.) insulation maximum

Technical documents (1)

Key features

  • Eight isolated output channels, each set to voltage or current
  • Output ranges of -10 to 10V, 0 to 10V, 0 to 5V and 0 to 20 mA
  • 16 bit resolution with IEEE 32-bit floating point data format
  • Open circuit detection on current output, short circuit detection on voltage output
  • Electronic keying set in software, with user-defined mechanical RTB keying

About the Allen-Bradley 1756-OF8I

The 1756-OF8I is a ControlLogix analog output module with 8 isolated points for current and voltage (36 pin). Calibrated accuracy is 0.05% at 25 °C, module scan time is 1 ms minimum, and settling time is under 2 ms to 95% of final value with resistive loads. Isolation is 250V continuous, reinforced insulation from outputs to backplane and basic insulation from output to output.

What is the 1756-OF8I used for?

It turns control data into analog signals for actuators, drives and other field devices, with each of the eight isolated channels set to voltage or current mode. Current outputs drive 0 to 1000 Ω and voltage outputs drive loads above 1000 Ω.

Lifecycle and successor

Active (Rockwell Automation lifecycle status, checked 24 October 2026).

Before you order

What to photograph or confirm so the right unit is quoted.

Read the catalog number 1756-OF8I, the series letter and the firmware revision from the label. Send us a photo of the label and we confirm the match before we quote.

Other parts in the Allen-Bradley ControlLogix I/O Modules family

Listed for reference. They differ from the 1756-OF8I in rating, supply, interface or function and are not interchangeable with it unless Allen-Bradley says so. Match the part number on your unit.

ProductTypeLifecycleQty AvailablePriceAction
Allen-Bradley 1756-OW16IControlLogix 16 Point Isolated Relay Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-IF16HControlLogix 16 Point HART Analog Input ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-IF6IControlLogix 6 Point Isolated Analogue Input ModuleAnalog input moduleDiscontinuedOn requestOn requestView
Allen-Bradley 1756-IF8ControlLogix 8 Point A/I ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-IF8IControlLogix 8 Point Isolated Analog Input ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-IRT8IControlLogix 8 Point RTD/Thermocouple Input ModuleAnalog input moduleActiveOn requestOn requestView
Allen-Bradley 1756-OA16ControlLogix 16 Point 74-265 VAC Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OA16IControlLogix 16 Point Isolated AC Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OB16DControlLogix 16 Point 24V DC Diagnostic Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OB16EControlLogix 16 Point Fused DC Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OB32ControlLogix 32 Point 12/24V DC Output ModuleDigital output moduleActiveOn requestOn requestView
Allen-Bradley 1756-OF8ControlLogix 8 Point Analog Output ModuleAnalog output moduleActiveOn requestOn requestView

You may also be interested in

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Allen-Bradley 1756-OF8I? Send us the details.