Skip to content
Industrial

VLT 2880 380-480 V

Danfoss VLT 2800 type 2880, 11 kW, 3 x 380-480 V

Danfoss

Delivery options

  • FedEx
  • DHL
  • UPS

Danfoss VLT 2880 frequency converter from the VLT 2800 series: 11 kW, 24 A, 3 x 380-480 V, IP20/NEMA 1. Ordering numbers 195N1109 to 195N1120. Discontinued by Danfoss.

Manufacturer
Danfoss
Manufacturer part no.
VLT 2880 380-480 V
Type
AC drive
Lifecycle
Discontinued
OEM successor
VLT Midi Drive FC 280
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Danfoss
Manufacturer part no.
VLT 2880 380-480 V
Type
AC drive
Application
AC motor speed control
Used with
Three-phase AC motors
Mains supply
3 x 380-480 V
Output current IINV
24 A (3 x 380-480 V)
Output current IMAX (60 s)
38.4 A
Output power SINV (400 V)
16.6 kVA
Typical shaft output
11 kW (15 HP)
Input current IL,N (3 x 380-480 V)
24 A
Input current IL,MAX 60 s (3 x 380-480 V)
38.4 A
Max. cable cross-section, motor and power
16 mm² / AWG 6
Max. pre-fuses IEC/UL
50/50 A
Efficiency
97 %
Power loss at 100 % load
412 W
Weight
18.5 kg
Enclosure
IP20/NEMA 1
Ordering no. – standard unit (ST), no RFI filter, no fieldbus
195N1109
Ordering no. – with integral brake (SB), no RFI filter, no fieldbus
195N1110
Ordering no. – standard unit (ST), RFI filter R3, no fieldbus
195N1111
Ordering no. – with integral brake (SB), RFI filter R3, no fieldbus
195N1112
Ordering nos. – versions with a fieldbus option (Profibus DP or DeviceNet)
195N1113, 195N1114, 195N1115, 195N1116, 195N1117, 195N1118, 195N1119, 195N1120

Technical documents (1)

Key features

  • 11 kW typical shaft output
  • Output current 24 A
  • Mains supply 3 x 380-480 V
  • IP20/NEMA 1
  • Versions with integral brake (SB), RFI filter and Profibus DP or DeviceNet
  • Danfoss lists the VLT 2800 as discontinued; successor VLT Midi Drive FC 280

About the Danfoss VLT 2880 380-480 V

The Danfoss VLT 2880 is an 11 kW frequency converter from the VLT 2800 series for 3 x 380-480 V supplies. Danfoss's VLT 2800 design guide gives it an output current of 24 A and 38.4 A for 60 s, and lists twelve ordering numbers, 195N1109 to 195N1120, for its versions: standard unit (ST) or with integral brake (SB), with or without RFI filter, and with or without a Profibus DP or DeviceNet fieldbus. Danfoss's product page states that the VLT 2800 has reached the Inactive phase of its lifecycle, meaning it is discontinued and no longer in production, and names the VLT Midi Drive FC 280 as its successor, with full backwards compatibility.

What is the VLT 2880 380-480 V used for?

It controls the speed of a three-phase AC motor on pumps, fans, conveyors and machines. A failed unit stops the motor it drives.

Lifecycle and successor

Discontinued.

OEM successor: VLT Midi Drive FC 280

Before you order

What to photograph or confirm so the right unit is quoted.

Check the type (VLT 2880) and the ordering number (195N…) on the drive's label: the ordering number tells the version apart (brake, RFI filter, fieldbus). Send both, and the supply voltage.

Alternatives for VLT 2880 380-480 V

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
VLT Midi Drive FC 280Named by the manufacturer as the successorDanfossAC driveNot checked; ask usOEM successor (upgrade path)On RequestOn requestView ›
Danfoss VLT 2803 200-240 VVLT 2800 type 2803, 0.37 kW, 1 x 220-240 V / 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2805 200-240 VVLT 2800 type 2805, 0.55 kW, 1 x 220-240 V / 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2807 200-240 VVLT 2800 type 2807, 0.75 kW, 1 x 220-240 V / 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2811 200-240 VVLT 2800 type 2811, 1.1 kW, 1 x 220-240 V / 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2815 200-240 VVLT 2800 type 2815, 1.5 kW, 1 x 220-240 V / 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2822 200-240 VVLT 2800 type 2822, 2.2 kW, 1 x 220-240 V / 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2840 200-240 VVLT 2800 type 2840, 3.7 kW, 1 x 220-240 V / 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2805 380-480 VVLT 2800 type 2805, 0.55 kW, 3 x 380-480 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2807 380-480 VVLT 2800 type 2807, 0.75 kW, 3 x 380-480 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2811 380-480 VVLT 2800 type 2811, 1.1 kW, 3 x 380-480 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2815 380-480 VVLT 2800 type 2815, 1.5 kW, 3 x 380-480 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 2822 380-480 VVLT 2800 type 2822, 2.2 kW, 3 x 380-480 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Danfoss VLT 2880 380-480 V? Send us the details.