Image is for illustrative purposes only. Please refer to product description.
Delivery options
Siemens SIMATIC HMI TP700 Comfort: Comfort Panel, touch, 7" widescreen TFT, 16 million colours, PROFINET and MPI/PROFIBUS DP, 12 MB configuration memory, Windows CE 6.0.
- Manufacturer
- Siemens
- Manufacturer part no.
- 6AV2124-0GC01-0AX0
- Product family
- SIMATIC HMI Operator Panels
- Type
- HMI panel
- Lifecycle
- Phase-out announced (Siemens SiePortal)
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Siemens
- Manufacturer part no.
- 6AV2124-0GC01-0AX0
- Type
- HMI panel
- Application
- Operator panel
- Used with
- SIMATIC controllers via PROFINET or MPI/PROFIBUS
- Product type designation
- TP700 Comfort
- Design of display
- TFT
- Display / Screen diagonal
- 7 in
- Display width
- 152.4 mm
- Display height
- 91.4 mm
- Display / Number of colors
- 16 777 216
- Resolution (pixels) / Horizontal image resolution
- 800 pixel
- Resolution (pixels) / Vertical image resolution
- 480 pixel
- Backlighting / MTBF backlighting (at 25 °C)
- 80 000 h
- Backlighting / Backlight dimmable
- Yes; 0-100 %
- Keyboard / Function keys / Number of function keys
- 0
- Keyboard / Function keys / Number of function keys with LEDs
- 0
- Keyboard / Keys with LED
- No
- Keyboard / System keys
- No
- Keyboard / Numeric keyboard
- Yes; Onscreen keyboard
- Keyboard / alphanumeric keyboard
- Yes; Onscreen keyboard
- Touch operation / Design as touch screen
- Yes; Analog-resistive
- Expansions for operator control of the process / DP direct LEDs (LEDs as S7 output I/O) / F1...Fx
- 0
- Expansions for operator control of the process / Direct keys (keys as S7 input I/O) / F1...Fx
- 0
- Expansions for operator control of the process / Direct keys (touch buttons as S7 input I/O)
- 32
- Installation type/mounting / Mounting position
- vertical
- Installation type/mounting / Wall mounting/direct mounting
- No
- Installation type/mounting / Mounting in portrait format possible
- Yes
- Installation type/mounting / Mounting in landscape format possible
- Yes
- Installation type/mounting / maximum permissible angle of inclination without external ventilation
- 35°
Show all 284 specificationsShow fewer
- Type of supply voltage
- DC
- Supply voltage / Rated value (DC)
- 24 V
- Supply voltage / permissible range, lower limit (DC)
- 19.2 V
- Supply voltage / permissible range, upper limit (DC)
- 28.8 V
- Input current / Current consumption (rated value)
- 0.5 A
- Input current / Starting current inrush I²t
- 0.5 A²·s
- Active power input, typ.
- 12 W
- Processor type
- X86
- Storage / Flash
- Yes
- Storage / RAM
- Yes
- Storage / Memory available for user data
- 12 Mbyte
- Type of output / Info LED
- No
- Type of output / Power LED
- No
- Type of output / Error LED
- No
- Acoustics / Buzzer
- No
- Acoustics / Speaker
- Yes
- Clock / Hardware clock (real-time)
- Yes
- Clock / Software clock
- Yes
- Clock / retentive
- Yes; Back-up duration typically 6 weeks
- Clock / synchronizable
- Yes
- Number of industrial Ethernet interfaces
- 1; 2 ports (switch)
- Number of RS 485 interfaces
- 1; RS 422 / 485 combined
- Number of RS 422 interfaces
- 0; together with RS 485
- Number of RS 232 interfaces
- 0
- Number of USB interfaces
- 2; USB 2.0
- Number of USB interfaces / USB Mini B
- 1; 5-pole
- Number of 20 mA interfaces (TTY)
- 0
- Number of parallel interfaces
- 0
- Interfaces / Number of SD card slots
- 2
- With software interfaces
- No
- Industrial Ethernet / Industrial Ethernet status LED
- 2
- Industrial Ethernet / Number of ports of the integrated switch
- 2
- Protocols / PROFINET
- Yes
- Protocols / Supports protocol for PROFINET IO
- Yes
- Protocols / IRT
- Yes; As of WinCC V12
- Protocols / PROFIBUS
- Yes
- Protocols / EtherNet/IP
- Yes
- Protocols / MPI
- Yes
- Protocols (Ethernet) / TCP/IP
- Yes
- Protocols (Ethernet) / DHCP
- Yes
- Protocols (Ethernet) / SNMP
- Yes
- Protocols (Ethernet) / DCP
- Yes
- Protocols (Ethernet) / LLDP
- Yes
- WEB characteristics / HTTP
- Yes
- WEB characteristics / HTTPS
- Yes
- WEB characteristics / HTML
- Yes
- WEB characteristics / XML
- Yes
- WEB characteristics / CSS
- Yes
- WEB characteristics / Active X
- Yes
- WEB characteristics / JavaScript
- Yes
- WEB characteristics / Java VM
- No
- Redundancy mode / Media redundancy / MRP
- Yes; As of WinCC V12
- Further protocols / CAN
- No
- Further protocols / MODBUS
- Yes
- Diagnoses / Diagnostic information readable
- Yes; S7 controller
- Emission of radio interference acc. to EN 55 011 / Limit class A, for use in industrial areas
- Yes
- Emission of radio interference acc. to EN 55 011 / Limit class B, for use in residential areas
- No
- Degree and class of protection / IP (at the front)
- IP65
- Degree and class of protection / IP (rear)
- IP20
- NEMA (front) / Enclosure Type 4 at the front
- Yes
- NEMA (front) / Enclosure Type 4x at the front
- Yes
- Standards, approvals, certificates / CE mark
- Yes
- Standards, approvals, certificates / cULus
- Yes
- Standards, approvals, certificates / RCM (formerly C-TICK)
- Yes
- Standards, approvals, certificates / KC approval
- Yes
- Use in hazardous areas / ATEX Zone 2
- Yes
- Use in hazardous areas / ATEX Zone 22
- Yes
- Use in hazardous areas / IECEx Zone 2
- Yes
- Use in hazardous areas / IECEx Zone 22
- Yes
- Use in hazardous areas / cULus Class I Zone 1
- No
- Use in hazardous areas / cULus Class I Zone 2, Division 2
- Yes
- Use in hazardous areas / FM Class I Division 2
- Yes
- Marine approval / Germanischer Lloyd (GL)
- Yes
- Marine approval / American Bureau of Shipping (ABS)
- Yes
- Marine approval / Bureau Veritas (BV)
- Yes
- Marine approval / Det Norske Veritas (DNV)
- Yes
- Marine approval / Lloyds Register of Shipping (LRS)
- Yes
- Marine approval / Nippon Kaiji Kyokai (Class NK)
- Yes
- Marine approval / Polski Rejestr Statkow (PRS)
- No
- Ambient conditions / Suited for indoor use
- Yes
- Ambient conditions / Suited for outdoor use
- No
- Ambient temperature during operation / Operation (vertical installation) / For vertical installation, min.
- 0 °C
- Ambient temperature during operation / Operation (vertical installation) / For vertical installation, max.
- 50 °C; (55 °C, see entry ID: 64847814)
- Ambient temperature during operation / Operation (max. tilt angle) / At maximum tilt angle, min.
- 0 °C
- Ambient temperature during operation / Operation (max. tilt angle) / At maximum tilt angle, max.
- 40 °C
- Ambient temperature during operation / Operation (vertical installation, portrait format) / For vertical installation, min.
- 0 °C
- Ambient temperature during operation / Operation (vertical installation, portrait format) / For vertical installation, max.
- 40 °C
- Ambient temperature during operation / Operation (max. tilt angle, portrait format) / At maximum tilt angle, min.
- 0 °C
- Ambient temperature during operation / Operation (max. tilt angle, portrait format) / At maximum tilt angle, max.
- 35 °C
- Ambient temperature during storage/transportation / min.
- -20 °C
- Ambient temperature during storage/transportation / max.
- 60 °C
- Relative humidity / Operation, max.
- 90 %; no condensation
- Operating systems / proprietary
- No
- pre-installed operating system / Windows CE
- Yes
- Configuration / Message indicator
- Yes
- Configuration / Alarm system (incl. buffer and acknowledgment)
- Yes
- Configuration / Process value display (output)
- Yes
- Configuration / Process value default (input) possible
- Yes
- Configuration / Recipe management
- Yes
- Configuration software / STEP 7 Basic (TIA Portal)
- No
- Configuration software / STEP 7 Professional (TIA Portal)
- No
- Configuration software / WinCC flexible Compact
- No
- Configuration software / WinCC flexible Standard
- No
- Configuration software / WinCC flexible Advanced
- No
- Configuration software / WinCC Basic (TIA Portal)
- No
- Configuration software / WinCC Comfort (TIA Portal)
- Yes; from V11
- Configuration software / WinCC Advanced (TIA Portal)
- Yes; from V11
- Configuration software / WinCC Professional (TIA Portal)
- Yes; from V11
- Online languages / Number of online/runtime languages
- 32
- Project languages / Languages per project
- 32
- Functionality under WinCC (TIA Portal) / Libraries
- Yes
- Applications/options / Web browser
- Yes
- Applications/options / Pocket Word
- Yes
- Applications/options / Pocket Excel
- Yes
- Applications/options / PDF Viewer
- Yes
- Applications/options / Media Player
- Yes
- Applications/options / SIMATIC WinCC Sm@rtServer
- Yes
- Applications/options / SIMATIC WinCC Audit
- Yes
- Functionality under WinCC (TIA Portal) / Number of Visual Basic Scripts
- Yes
- Task planner / time-controlled
- Yes
- Task planner / task-controlled
- Yes
- Help system / Number of characters per info text
- 70
- Message system / Number of alarm classes
- 32
- Message system / Bit messages
- Yes
- Message system / Bit messages / Number of bit messages
- 4 000
- Message system / Analog messages
- Yes
- Message system / Analog messages / Number of analog messages
- 200
- Message system / S7 alarm number procedure
- Yes
- Message system / System messages HMI
- Yes
- Message system / System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )
- Yes
- Message system / Number of characters per message
- 80
- Message system / Number of process values per message
- 8
- Message system / Acknowledgment groups
- Yes
- Message system / Message indicator
- Yes
- Message system / Message buffer / Number of entries
- 1 024
- Message system / Message buffer / Circulating buffer
- Yes
- Message system / Message buffer / retentive
- Yes
- Message system / Message buffer / maintenance-free
- Yes
- Recipe management / Number of recipes
- 300
- Recipe management / Data records per recipe
- 500
- Recipe management / Entries per data record
- 1 000
- Recipe management / Size of internal recipe memory
- 2 Mbyte
- Recipe management / Recipe memory expandable
- Yes
- Variables / Number of variables per device
- 2 048
- Variables / Number of variables per screen
- 400
- Variables / Limit values
- Yes
- Variables / Multiplexing
- Yes
- Variables / Structures
- Yes
- Variables / Arrays
- Yes
- Images / Number of configurable images
- 500
- Images / Permanent window/default
- Yes
- Images / Global image
- Yes
- Images / Pop-up images
- Yes
- Images / Slide-in images
- Yes
- Images / Image selection by PLC
- Yes
- Images / Image number in the PLC
- Yes
- Image objects / Number of objects per image
- 400
- Image objects / Text fields
- Yes
- Image objects / I/O fields
- Yes
- Image objects / Graphic I/O fields (graphics list)
- Yes
- Image objects / Symbolic I/O fields (text list)
- Yes
- Image objects / Date/time fields
- Yes
- Image objects / Switches
- Yes
- Image objects / Buttons
- Yes
- Image objects / Graphic display
- Yes
- Image objects / Icons
- Yes
- Image objects / Geometric objects
- Yes
- Complex image objects / Number of complex objects per screen
- 20
- Complex image objects / Alarm view
- Yes
- Complex image objects / Trend view
- Yes
- Complex image objects / User view
- Yes
- Complex image objects / Status/control
- Yes
- Complex image objects / Sm@rtClient view
- Yes
- Complex image objects / Recipe view
- Yes
- Complex image objects / f(x) trend view
- Yes
- Complex image objects / System diagnostics view
- Yes
- Complex image objects / Media Player
- Yes
- Complex image objects / HTML browser
- Yes
- Complex image objects / PDF display
- Yes
- Complex image objects / IP camera display
- Yes
- Complex image objects / Bar graphs
- Yes
- Complex image objects / Sliders
- Yes
- Complex image objects / Pointer instruments
- Yes
- Complex image objects / Analog/digital clock
- Yes
- Lists / Number of text lists per project
- 500
- Lists / Number of entries per text list
- 500
- Lists / Number of graphics lists per project
- 500
- Lists / Number of entries per graphics list
- 500
- Archiving / Number of archives per device
- 50
- Archiving / Number of entries per archive
- 20 000
- Archiving / Message archive
- Yes
- Archiving / Process value archive
- Yes
- Archiving / Archiving methods / Sequential archive
- Yes
- Archiving / Archiving methods / Short-term archive
- Yes
- Archiving / Memory location / Memory card
- Yes
- Archiving / Memory location / USB memory
- Yes
- Archiving / Memory location / Ethernet
- Yes
- Archiving / Data storage format / CSV
- Yes
- Archiving / Data storage format / TXT
- Yes
- Archiving / Data storage format / RDB
- Yes
- Security / Number of user groups
- 50
- Security / Number of user rights
- 32
- Security / Number of users
- 50
- Security / Password export/import
- Yes
- Security / SIMATIC Logon
- Yes
- Logging through printer / Alarms
- Yes
- Logging through printer / Report (shift log)
- Yes
- Logging through printer / Hardcopy
- Yes
- Logging through printer / Electronic print to file
- Yes; PDF, HTML
- Character sets / Keyboard fonts / US English
- Yes
- Transfer (upload/download) / MPI/PROFIBUS DP
- Yes
- Transfer (upload/download) / USB
- Yes
- Transfer (upload/download) / Ethernet
- Yes
- Transfer (upload/download) / using external storage medium
- Yes
- Process coupling / S7-1200
- Yes
- Process coupling / S7-1500
- Yes
- Process coupling / S7-200
- Yes
- Process coupling / S7-300/400
- Yes
- Process coupling / LOGO!
- Yes
- Process coupling / WinAC
- Yes
- Process coupling / SINUMERIK
- Yes; with SINUMERIK option package
- Process coupling / SIMOTION
- Yes
- Process coupling / Allen Bradley (EtherNet/IP)
- Yes
- Process coupling / Allen Bradley (DF1)
- Yes
- Process coupling / Mitsubishi (MC TCP/IP)
- Yes
- Process coupling / Mitsubishi (FX)
- Yes
- Process coupling / OMRON (FINS TCP)
- No
- Process coupling / OMRON (Host Link)
- Yes
- Process coupling / Modicon (Modbus TCP/IP)
- Yes
- Process coupling / Modicon (Modbus RTU)
- Yes
- Process coupling / OPC UA Client
- Yes
- Process coupling / OPC UA Server
- Yes
- Service tools/configuration aids / Backup/Restore manually
- Yes
- Service tools/configuration aids / Backup/Restore automatically
- Yes
- Service tools/configuration aids / Simulation
- Yes
- Service tools/configuration aids / Device switchover
- Yes
- Peripherals/Options / Printer
- Yes
- Peripherals/Options / SIMATIC HMI MM memory card: Multi Media Card
- Yes; Up to 128 MB
- Peripherals/Options / SIMATIC HMI SD memory card: Secure Digital memory card
- Yes; Up to 2 GB
- Peripherals/Options / SIMATIC HMI CF memory card Compact Flash Card
- No
- Peripherals/Options / USB memory
- Yes
- Peripherals/Options / SIMATIC IPC USB Flashdrive (USB stick)
- Yes; Up to 16 GB
- Peripherals/Options / SIMATIC HMI USB stick
- Yes; Up to 8 GB
- Peripherals/Options / Network camera
- Yes
- Enclosure material (front) / Plastic
- No
- Enclosure material (front) / Aluminum
- Yes
- Enclosure material (front) / Stainless steel
- No
- Width of the housing front
- 214 mm
- Height of housing front
- 158 mm
- Mounting cutout, width
- 198 mm
- Mounting cutout, height
- 142 mm
- mounting depth
- 63 mm
- Weight (without packaging)
- 1.4 kg
- Weight (with packaging)
- 1.6 kg
Technical documents (1)
Key features
- 7-inch widescreen TFT, 16 million colours
- Touch operation
- PROFINET and MPI/PROFIBUS DP interfaces
- 12 MB configuration memory; Windows CE 6.0
- Configured with WinCC Comfort from V11
- Siemens has announced its phase-out
About the Siemens 6AV2124-0GC01-0AX0
The Siemens 6AV2124-0GC01-0AX0 is the TP700 Comfort, a 7-inch touch Comfort Panel. Siemens describes it with a widescreen TFT in 16 million colours, PROFINET and MPI/PROFIBUS DP interfaces, 12 MB of configuration memory and Windows CE 6.0, configured with WinCC Comfort from V11. SiePortal lists it as phase-out announced.
What is the 6AV2124-0GC01-0AX0 used for?
It is the operator screen of machines and lines, connected to the controller over PROFINET, or over MPI or PROFIBUS.
Lifecycle and successor
Phase-out announced (Siemens SiePortal).
Before you order
What to photograph or confirm so the right unit is quoted.
Check the order number on the rating plate on the back. A replacement panel has to be loaded with the project from the engineering software (WinCC).
Alternatives for 6AV2124-0GC01-0AX0
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| Siemens 6AV2123-2GB03-0AX0KTP700 Basic PN, 7" key/touch panel | Siemens | HMI panel | Active product (Siemens SiePortal) | Same family | On Request | On request | View › |
| Siemens 6AV2124-0MC01-0AX0TP1200 Comfort, 12" touch panel | Siemens | HMI panel | Phase-out announced (Siemens SiePortal) | Same family | On Request | On request | View › |
| Siemens 6AV2128-3QB06-0AX1MTP1500 Unified Comfort, 15.6" touch panel | Siemens | HMI panel | Active product (Siemens SiePortal) | Same family | On Request | On request | View › |
You may also be interested in

Siemens
Siemens 6ES7972-0BA12-0XA0
View ›
Siemens
Siemens 6ES7972-0BB12-0XA0
View ›
Siemens
Siemens 6ES7972-0BA42-0XA0
View ›
Siemens
Siemens 6ES7972-0BB42-0XA0
View ›
Siemens
Siemens 6ES7972-0BA52-0XA0
View ›
Siemens
Siemens 6ES7972-0BB52-0XA0
View ›
Siemens
Siemens 6ES7972-0BA61-0XA0
View ›
Siemens
Siemens 6ES7972-0BA70-0XA0
View ›
Siemens
Siemens 6GK1500-0FC10
View ›
Siemens
Siemens 6GK1901-1BB10-2AA0
View ›
Siemens
Siemens 6GK1901-1BB11-2AA0
View ›
Siemens
Siemens 6XV1830-0EH10
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.