Skip to content
Industrial

VLT 5032 380-500 V

Danfoss VLT 5000 type 5032, 30 kW, 3 x 380-500 V

Danfoss

Delivery options

  • FedEx
  • DHL
  • UPS

Danfoss VLT 5032 frequency converter from the VLT 5000 series for 3 x 380-500 V: 30 kW, output current 61 A. Discontinued by Danfoss; successor iC7-Automation.

Manufacturer
Danfoss
Manufacturer part no.
VLT 5032 380-500 V
Type
AC drive
Lifecycle
Discontinued
OEM successor
iC7-Automation
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Danfoss
Manufacturer part no.
VLT 5032 380-500 V
Type
AC drive
Application
AC motor speed control
Used with
Three-phase AC motors
Mains supply
3 x 380-500 V
Normal overload torque (110 %) / Output current I VLT,N [A] (380-415 V)
61
Normal overload torque (110 %) / Output current I VLT,MAX (60 s) [A] (380-415 V)
67.1
Normal overload torque (110 %) / Output current I VLT,N [A] (440-500 V)
54
Normal overload torque (110 %) / Output current I VLT,MAX (60 s) [A] (440-500 V)
59.4
Normal overload torque (110 %) / Output S VLT,N [kVA] (380-415 V)
46.5
Normal overload torque (110 %) / Output S VLT,N [kVA] (440-500 V)
46.8
Normal overload torque (110 %) / Typical shaft output P VLT,N [kW]
30
Normal overload torque (110 %) / Typical shaft output P VLT,N [HP]
40
High overload torque (160 %) / Output current I VLT,N [A] (380-415 V)
44
High overload torque (160 %) / Output current I VLT,MAX (60 s) [A] (380-415 V)
70.4
High overload torque (160 %) / Output current I VLT,N [A] (440-500 V)
41.4
High overload torque (160 %) / Output current I VLT,MAX (60 s) [A] (440-500 V)
66.2
High overload torque (160 %) / Output S VLT,N [kVA] (380-415 V)
33.5
High overload torque (160 %) / Output S VLT,N [kVA] (440-500 V)
35.9
High overload torque (160 %) / Typical shaft output P VLT,N [kW]
22
High overload torque (160 %) / Typical shaft output P VLT,N [HP]
30
Rated input current I L,N [A] (380 V)
60
Rated input current I L,N [A] (460 V)
53
Max. pre-fuses IEC/UL [A]
80/80
Efficiency
0.96
Weight IP 20 EB [kg]
28
Weight IP 54 [kg]
54
Power loss, high overload [W]
768
Power loss, normal overload [W]
1065

Technical documents (1)

Key features

  • 30 kW at normal overload
  • Output current 61 A at normal overload
  • Mains supply 3 x 380-500 V
  • Separate ratings for normal (110 %) and high (160 %) overload
  • Discontinued by Danfoss; successor iC7-Automation

About the Danfoss VLT 5032 380-500 V

The Danfoss VLT 5032 is a 30 kW frequency converter from the VLT 5000 series for 3 x 380-500 V supplies. Danfoss's VLT 5000 design guide gives it an output current of 61 A at normal overload (110 %), with separate ratings for high overload (160 %); the full electrical data from the design guide is listed below. Danfoss's product page states that the VLT 5000 has reached the Inactive phase of its lifecycle, meaning it is discontinued and no longer in production, and names iC7-Automation as its successor.

What is the VLT 5032 380-500 V used for?

It controls the speed of a three-phase AC motor on pumps, fans, compressors, conveyors and process machinery. A failed unit stops the motor it drives.

Lifecycle and successor

Discontinued.

OEM successor: iC7-Automation

Before you order

What to photograph or confirm so the right unit is quoted.

Read the full type code on the drive's label (it starts VLT5032, followed by the voltage, enclosure, brake, filter and option codes) and send it complete: the options differ between otherwise identical 5032 units.

Alternatives for VLT 5032 380-500 V

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
iC7-AutomationNamed by the manufacturer as the successorDanfossAC driveNot checked; ask usOEM successor (upgrade path)On RequestOn requestView ›
Danfoss VLT 5001 200-240 VVLT 5000 type 5001, 0.75 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5002 200-240 VVLT 5000 type 5002, 1.1 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5003 200-240 VVLT 5000 type 5003, 1.5 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5004 200-240 VVLT 5000 type 5004, 2.2 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5005 200-240 VVLT 5000 type 5005, 3.0 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5006 200-240 VVLT 5000 type 5006, 3.7 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5008 200-240 VVLT 5000 type 5008, 7.5 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5011 200-240 VVLT 5000 type 5011, 11 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5016 200-240 VVLT 5000 type 5016, 15 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5022 200-240 VVLT 5000 type 5022, 18.5 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5027 200-240 VVLT 5000 type 5027, 22 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›
Danfoss VLT 5032 200-240 VVLT 5000 type 5032, 30 kW, 3 x 200-240 VDanfossAC driveDiscontinuedSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Danfoss VLT 5032 380-500 V? Send us the details.