Danfoss VLT 5402 525-690 V

VLT 5000 type 5402, 400 kW, 3 x 525-690 V

Request a quote
Danfoss
VLT 5000 Frequency Converters family illustration for VLT 5402 525-690 V; exact appearance unverified

Image is for illustrative purposes only. Please refer to product description.

  • FedEx
  • DHL
  • UPS
Manufacturer
Danfoss
Manufacturer part number
VLT 5402 525-690 V
Technical datasheet
Data sheet

Specifications

AttributeValue
TypeAC drive
Manufacturer lifecycleDiscontinued
OEM successoriC7-Automation
Mains supply3 x 525-690 V
Normal overload current (110 %) / Output current I VLT,N [A] (525-550 V)523
Normal overload current (110 %) / Output current I VLT,MAX (60 s) [A] (525-550 V)575
Normal overload current (110 %) / Output current I VLT,MAX (60 s) [A] (551-690 V)550
Normal overload current (110 %) / Output S VLT,N [kVA] (550 V)498
Normal overload current (110 %) / Output S VLT,N [kVA] (575 V)498
Normal overload current (110 %) / Output S VLT,N [kVA] (690 V)598
Normal overload current (110 %) / Typical shaft output [kW] (550 V)400
Normal overload current (110 %) / Typical shaft output [HP] (575 V)500
Normal overload current (110 %) / Typical shaft output [kW] (690 V)500
High overload torque (160 %) / Output current I VLT,N [A] (525-550 V)429
High overload torque (160 %) / Output current I VLT,MAX (60 s) [A] (525-550 V)644
Show all 32 specifications
High overload torque (160 %) / Output current I VLT,N [A] (551-690 V)410
High overload torque (160 %) / Output current I VLT,MAX (60 s) [A] (551-690 V)615
High overload torque (160 %) / Output S VLT,N [kVA] (550 V)409
High overload torque (160 %) / Output S VLT,N [kVA] (575 V)408
High overload torque (160 %) / Output S VLT,N [kVA] (690 V)490
High overload torque (160 %) / Typical shaft output [kW] (550 V)315
High overload torque (160 %) / Typical shaft output [HP] (575 V)400
High overload torque (160 %) / Typical shaft output [kW] (690 V)400
Normal overload current (110 %) / Rated input current I L,N [A] (525-550 V)504
Normal overload current (110 %) / Rated input current I L,N [A] (551-690 V)482
Rated input current I L,N [A] (525-550 V)413
Rated input current I L,N [A] (551-690 V)395
Power loss, normal overload [W]7249
Power loss, high overload [W]5818
Weight IP 00 [kg]221
Weight IP 21/Nema1 [kg]263
Weight IP 54/Nema12 [kg]263

OEM successor to VLT 5402 525-690 V

iC7-Automation is named by Danfoss as the successor. It is an upgrade, not a like-for-like spare: check wiring, I/O and configuration for your installation before ordering it. Contact sales@timcontrols.com if you need one.

Associated Products

ImageProductDescriptionStockViewAdd to RFQ
Danfoss VLT 5052 525-690 V
VLT 5052 525-690 VDanfossVLT 5000 type 5052, 45 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5062 525-690 V
VLT 5062 525-690 VDanfossVLT 5000 type 5062, 55 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5072 525-690 V
VLT 5072 525-690 VDanfossVLT 5000 type 5072, 75 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5102 525-690 V
VLT 5102 525-690 VDanfossVLT 5000 type 5102, 90 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5122 525-690 V
VLT 5122 525-690 VDanfossVLT 5000 type 5122, 110 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5152 525-690 V
VLT 5152 525-690 VDanfossVLT 5000 type 5152, 132 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5202 525-690 V
VLT 5202 525-690 VDanfossVLT 5000 type 5202, 160 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5252 525-690 V
VLT 5252 525-690 VDanfossVLT 5000 type 5252, 200 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5302 525-690 V
VLT 5302 525-690 VDanfossVLT 5000 type 5302, 250 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5352 525-690 V
VLT 5352 525-690 VDanfossVLT 5000 type 5352, 315 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5502 525-690 V
VLT 5502 525-690 VDanfossVLT 5000 type 5502, 450 kW, 3 x 525-690 VIn stockView
Danfoss VLT 5602 525-690 V
VLT 5602 525-690 VDanfossVLT 5000 type 5602, 500 kW, 3 x 525-690 VIn stockView

Product Questions

Is the VLT 5402 525-690 V discontinued?

Yes. Its manufacturer lifecycle status is Discontinued.

Is there a replacement for the VLT 5402 525-690 V?

The iC7-Automation is named by Danfoss as the successor. It is an upgrade, not a like-for-like spare: check ratings, wiring and configuration before ordering it in its place.

Do you ship worldwide?

Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.

Lifecycle Database

Danfoss VLT 5000, 6000 and 8000 discontinued: status, successors and ratings

Danfoss no longer supplies spares or service for the VLT 5000, 6000 HVAC or 8000 AQUA. Successors by region, and the Danfoss rating of every drive we list.

Open the database

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need a part? Send us the part number.

Added to cart