Danfoss VLT 5552 380-500 V

VLT 5000 type 5552, 450 kW, 3 x 380-500 V

Request a quote
Danfoss
VLT 5000 Frequency Converters family illustration for VLT 5552 380-500 V; exact appearance unverified

Image is for illustrative purposes only. Please refer to product description.

  • FedEx
  • DHL
  • UPS
Manufacturer
Danfoss
Manufacturer part number
VLT 5552 380-500 V
Technical datasheet
Data sheet

Specifications

AttributeValue
TypeAC drive
Manufacturer lifecycleDiscontinued
OEM successoriC7-Automation
Mains supply3 x 380-500 V
Normal overload current (110 %) / Output current I VLT,N [A] (380-415 V)800
Normal overload current (110 %) / Output current I VLT,MAX (60 s) [A] (380-415 V)880
Normal overload current (110 %) / Output current I VLT,MAX (60 s) [A] (440-500 V)803
Normal overload current (110 %) / Output S VLT,N [kVA] (400 V)554
Normal overload current (110 %) / Output S VLT,N [kVA] (460 V)582
Normal overload current (110 %) / Output S VLT,N [kVA] (500 V)632
Normal overload current (110 %) / Typical shaft output [kW] (400 V)450
Normal overload current (110 %) / Typical shaft output [HP] (460 V)600
Normal overload current (110 %) / Typical shaft output [kW] (500 V)530
High overload torque (160 %) / Output current I VLT,N [A] (380-415 V)695
High overload torque (160 %) / Output current I VLT,MAX (60 s) [A] (380-415 V)1042
Show all 32 specifications
High overload torque (160 %) / Output current I VLT,N [A] (440-500 V)678
High overload torque (160 %) / Output current I VLT,MAX (60 s) [A] (440-500 V)1017
High overload torque (160 %) / Output S VLT,N [kVA] (400 V)482
High overload torque (160 %) / Output S VLT,N [kVA] (460 V)540
High overload torque (160 %) / Output S VLT,N [kVA] (500 V)587
High overload torque (160 %) / Typical shaft output [kW] (400 V)400
High overload torque (160 %) / Typical shaft output [HP] (460 V)550
High overload torque (160 %) / Typical shaft output [kW] (500 V)500
Normal overload current (110 %) / Rated input current I L,N [A] (380-415 V)787
Normal overload current (110 %) / Rated input current I L,N [A] (440-500 V)718
Rated input current I L,N [A] (380-415 V)684
Rated input current I L,N [A] (440-500 V)667
Power loss, normal overload [W]9428
Power loss, high overload [W]7964
Weight IP 00 [kg]277
Weight IP 21/Nema1 [kg]313
Weight IP 54/Nema12 [kg]313

OEM successor to VLT 5552 380-500 V

iC7-Automation is named by Danfoss as the successor. It is an upgrade, not a like-for-like spare: check wiring, I/O and configuration for your installation before ordering it. Contact sales@timcontrols.com if you need one.

Associated Products

ImageProductDescriptionStockViewAdd to RFQ
Danfoss VLT 5052 380-500 V
VLT 5052 380-500 VDanfossVLT 5000 type 5052, 45 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5062 380-500 V
VLT 5062 380-500 VDanfossVLT 5000 type 5062, 75 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5072 380-500 V
VLT 5072 380-500 VDanfossVLT 5000 type 5072, 90 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5102 380-500 V
VLT 5102 380-500 VDanfossVLT 5000 type 5102, 110 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5122 380-500 V
VLT 5122 380-500 VDanfossVLT 5000 type 5122, 110 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5152 380-500 V
VLT 5152 380-500 VDanfossVLT 5000 type 5152, 132 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5202 380-500 V
VLT 5202 380-500 VDanfossVLT 5000 type 5202, 160 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5252 380-500 V
VLT 5252 380-500 VDanfossVLT 5000 type 5252, 200 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5302 380-500 V
VLT 5302 380-500 VDanfossVLT 5000 type 5302, 250 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5352 380-500 V
VLT 5352 380-500 VDanfossVLT 5000 type 5352, 315 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5452 380-500 V
VLT 5452 380-500 VDanfossVLT 5000 type 5452, 355 kW, 3 x 380-500 VIn stockView
Danfoss VLT 5502 380-500 V
VLT 5502 380-500 VDanfossVLT 5000 type 5502, 400 kW, 3 x 380-500 VIn stockView

Product Questions

Is the VLT 5552 380-500 V discontinued?

Yes. Its manufacturer lifecycle status is Discontinued.

Is there a replacement for the VLT 5552 380-500 V?

The iC7-Automation is named by Danfoss as the successor. It is an upgrade, not a like-for-like spare: check ratings, wiring and configuration before ordering it in its place.

Do you ship worldwide?

Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.

Lifecycle Database

Danfoss VLT 5000, 6000 and 8000 discontinued: status, successors and ratings

Danfoss no longer supplies spares or service for the VLT 5000, 6000 HVAC or 8000 AQUA. Successors by region, and the Danfoss rating of every drive we list.

Open the database

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need a part? Send us the part number.

Added to cart