MELSEC-Q Analogue input module, 4 channels, thermocouple (B, R, S, K, E, J, T, N)

Mitsubishi Electric

Delivery options

  • FedEx
  • DHL
  • UPS

Mitsubishi Electric Q64TD is a MELSEC-Q analogue input module with 4 analogue input channels.

Manufacturer part no.
Q64TD
Type
Analog input module
Lifecycle
Phased out
OEM successor
R60TRD4-G
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Mitsubishi Electric
Manufacturer part no.
Q64TD
Type
Analog input module
Application
I/O module
Used with
MELSEC-Q base units
Number of analog input points
4 points (4 channels + cold junction compensation channels)
Number of channels
4 channels
Digital output, Temperature measured value
16-bit signed binary value (-2700...18200: value to the first decimal place × 10)
Digital output, Scaling value
16-bit signed binary value
Thermocouple compliance standards
JIS C1602-1995
Resolution
B, R, S, N: 0.3 ˚C; K, E, J, T: 0.1 ˚C
Accuracy, Thermocouple type, Measured temperature range
Accuracy (℃) = (Conversion accuracy) + (Temperature characteristics); ; Conversion accuracy (at operating ambient temperature 25±5 ゚C); Temperature characteristic (per operating ambient temperature variation of 1 ゚C); Maximum temperature error at ambient temperature 55゚C; Effect per wiring resistance 1Ω
Accuracy, B, 0...600 ゚C
―
Accuracy, B, 600...800 ゚C
Conversion accuracy: ±3.0 ˚C; Temperature characteristics: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±13.0 ˚C; Effect per wiring resistance: 0.009 ˚C/Ω
Accuracy, B, 800...1700 ゚C
Conversion accuracy: ±2.5 ˚C; Temperature characteristics: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C; Effect per wiring resistance: 0.008 ˚C/Ω
Accuracy, B, 1700...1820 ゚C
―
Accuracy, R, -50...0 ゚C
―
Accuracy, R, 0...300 ゚C
Conversion accuracy: ±2.5 ˚C; Temperature characteristics: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C; Effect per wiring resistance: 0.011 ˚C/Ω
Accuracy, R, 300...1600 ゚C
Conversion accuracy: ±2.0 ˚C; Temperature characteristics: ±0.3 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±9.5 ˚C; Effect per wiring resistance: 0.006 ˚C/Ω
Accuracy, R, 1600...1760 ゚C
―
Accuracy, S, -50...0 ゚C
―
Accuracy, S, 0...300 ゚C
Conversion accuracy: ±2.5 ˚C; Temperature characteristics: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C; Effect per wiring resistance: 0.011 ˚C/Ω
Accuracy, S, 300...1600 ゚C
Conversion accuracy: ±2.0 ˚C; Temperature characteristics: ±0.3 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±9.2 ˚C; Effect per wiring resistance: 0.006 ˚C/Ω
Accuracy, S, 1600...1760 ゚C
―
Accuracy, K, -270...-200 ゚C
―
Accuracy, K, -200...0 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.2 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±11.0 ˚C; Effect per wiring resistance: 0.004 ˚C/Ω
Accuracy, K, 0...1200 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±9.0 ˚C; Effect per wiring resistance: 0.002 ˚C/Ω
Accuracy, K, 1200...1370 ゚C
―
Accuracy, E, -270...-200 ゚C
―
Accuracy, E, -200...0 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.15 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±8.5 ˚C; Effect per wiring resistance: 0.003 ˚C/Ω
Show all 57 specifications
Accuracy, E, 0...900 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±6.75 ˚C; Effect per wiring resistance: 0.001 ˚C/Ω
Accuracy, E, 900...1000 ゚C
―
Accuracy, J, -210...-40 ゚C
―
Accuracy, J, -40...750 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±5.625 ˚C; Effect per wiring resistance: 0.002 ˚C/Ω
Accuracy, J, 750...1200 ゚C
―
Accuracy, T, -270...-200 ゚C
―
Accuracy, T, -200...0 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.1 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±6.0 ˚C; Effect per wiring resistance: 0.004 ˚C/Ω
Accuracy, T, 0...350 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±2.625 ˚C; Effect per wiring resistance: 0.002 ˚C/Ω
Accuracy, T, 350...400 ゚C
―
Accuracy, N, -270...-200 ゚C
―
Accuracy, N, -200...0 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.2 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±11.0 ˚C; Effect per wiring resistance: 0.006 ˚C/Ω
Accuracy, N, 0...1250 ゚C
Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±9.375 ˚C; Effect per wiring resistance: 0.003 ˚C/Ω
Accuracy, N, 1250...1300 ゚C
―
Accuracy, Cold junction compensation accuracy
±1.0 ˚C
Conversion speed
40 ms/channel
Disconnection detection
Available (each channel independent)
Isolation method
Between thermocouple input channel and programmable controller power supply: Transformer; Between thermocouple input channels: Transformer; Between cold junction temperature compensation channel (Pt100) and programmable controller power supply: Non-isolation
Dielectric withstand voltage
Between thermocouple input channel and programmable controller power supply, between thermocouple input channels: 1780 V AC rms/3 cycles (altitude 2000 m)
Insulation resistance
Between thermocouple input channel and programmable controller power supply: 500 V DC, 100 MΩ or higher; Between thermocouple input channels: 500 V DC, 10 MΩ or higher
External interface,
18-point terminal block (M3 screw)
Number of occupied I/O points
16 points (I/O assignment: Intelligent 16 points)
Internal current consumption (5 V DC)
0.50 A
External dimensions, Height
98 mm
External dimensions, Width
27.4 mm
External dimensions, Depth
112 mm
Weight
0.25 kg
General specifications
Refer to the general specifications of the CPU module.

Technical documents (1)

Key features

  • Number of analog input points: 4 points (4 channels + cold junction compensation channels)
  • Number of channels: 4 channels
  • Digital output, Scaling value: 16-bit signed binary value
  • Thermocouple compliance standards: JIS C1602-1995
  • Resolution: B, R, S, N: 0.3 ˚C; K, E, J, T: 0.1 ˚C

About the Mitsubishi Electric Q64TD

The Mitsubishi Electric Q64TD is a MELSEC-Q analogue input module. Mitsubishi Electric's overview: 4 channels, thermocouple (B, R, S, K, E, J, T, N), conversion speed: 40 ms/channel, 18-point terminal block, channel isolated. Mitsubishi Electric names the R60TRD4-G as its replacement model.

What is the Q64TD used for?

The Q64TD mounts on a MELSEC-Q base unit and connects field signals to the CPU, which reads or writes them each cycle.

Lifecycle and successor

Phased out.

OEM successor: R60TRD4-G

Before you order

What to photograph or confirm so the right unit is quoted.

Check the model name Q64TD on the rating plate, with the serial number and function version. Send us a photo of the rating plate and we will confirm the details before quoting.

Alternatives for Q64TD

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
R60TRD4-GNamed by the manufacturer as the successorMitsubishi ElectricAnalog input moduleActiveOEM successor (upgrade path)On RequestOn requestView ›
Mitsubishi Electric Q64AD2DAMELSEC-Q Analogue I/O module, Analog input: 4 channelsMitsubishi ElectricAnalog I/O modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TDV-GHMELSEC-Q Analogue input module, 4 analogue input channelsMitsubishi ElectricAnalog input modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64RDMELSEC-Q Analogue input module, 4 analogue input channelsMitsubishi ElectricAnalog input modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64RD-GMELSEC-Q Analogue input module, 4 analogue input channelsMitsubishi ElectricAnalog input modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCTTNMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCTTMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control moduleDiscontinuedSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCTTBWNMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCTTBWMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control moduleDiscontinuedSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCRTNMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCRTMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control moduleDiscontinuedSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCRTBWNMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control modulePhased outSame familyOn RequestOn requestView ›
Mitsubishi Electric Q64TCRTBWMELSEC-Q Temperature control module, 4 temperature input channelsMitsubishi ElectricTemperature control moduleDiscontinuedSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Mitsubishi Electric Q64TD? Send us the details.