Mitsubishi Electric Q68TD-G-H02
MELSEC-Q Analogue input module, 8 channels, thermocouple (B, R, S, K, E, J, T, N)
Read from the product label
- Maker
- Mitsubishi Electric
- Part no.
- Q68TD-G-H02
- Serial / rev.
- as printed on your unit
Image is for illustrative purposes only. Please refer to product description.
Delivery options
Mitsubishi Electric Q68TD-G-H02 is a MELSEC-Q analogue input module with 8 analogue input channels and 320 ms/8 channels sampling.
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- Q68TD-G-H02
- Product family
- Mitsubishi MELSEC-Q I/O Modules
- Type
- Analog input module
- Category
- I/O modules › Analogue input and output modules
- Lifecycle
- Phased out
- OEM successor
- R60TD8-G
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- Q68TD-G-H02
- Type
- Analog input module
- Application
- I/O module
- Used with
- MELSEC-Q base units
- Number of analog input points
- 8 points (8 channels + cold junction compensation channels)
- Number of channels
- 8 channels
- Digital output, Temperature measured value
- 16-bit signed binary value (-2700...18200)
- Digital output, Scaling value
- 16-bit signed binary value
- Thermocouple compliance standards
- JIS C1602-1995, IEC 60584-1 (1995), IEC60584-2 (1982)
- Resolution
- B, R, S, N: 0.3 ˚C; K, E, J, T: 0.1 ˚C
- Accuracy, Thermocouple type, Measured temperature range
- Accuracy (℃) = (Conversion accuracy) + (Temperature characteristics); ; Conversion accuracy (at operating ambient temperature 25±5 ゚C); Temperature characteristic (per operating ambient temperature variation of 1 ゚C); Maximum temperature error at ambient temperature 55゚C; Effect per wiring resistance 1Ω
- Accuracy, B, 0...600 ゚C
- ―
- Accuracy, B, 600...800 ゚C
- Conversion accuracy: ±3.0 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±13.0 ˚C
- Accuracy, B, 800...1700 ゚C
- Conversion accuracy: ±2.5 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C
- Accuracy, B, 1700...1820 ゚C
- ―
- Accuracy, R, -50...0 ゚C
- ―
- Accuracy, R, 0...300 ゚C
- Conversion accuracy: ±2.5 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C
- Accuracy, R, 300...1600 ゚C
- Conversion accuracy: ±2.0 ˚C; Temperature characteristic: ±0.3 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±9.5 ˚C
- Accuracy, R, 1600...1760 ゚C
- ―
- Accuracy, S, -50...0 ゚C
- ―
- Accuracy, S, 0...300 ゚C
- Conversion accuracy: ±2.5 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C
- Accuracy, S, 300...1600 ゚C
- Conversion accuracy: ±2.0 ˚C; Temperature characteristic: ±0.3 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±9.5 ˚C
- Accuracy, S, 1600...1760 ゚C
- ―
- Accuracy, K, -270...-200 ゚C
- ―
- Accuracy, K, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.2 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±11.0 ˚C
- Accuracy, K, 0...1200 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±9.0 ˚C
- Accuracy, K, 1200...1370 ゚C
- ―
- Accuracy, E, -270...-200 ゚C
- ―
- Accuracy, E, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.15 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±8.5 ˚C
Show all 59 specificationsShow fewer
- Accuracy, E, 0...900 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±6.75 ˚C
- Accuracy, E, 900...1000 ゚C
- ―
- Accuracy, J, -210...-40 ゚C
- ―
- Accuracy, J, -40...750 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±5.625 ˚C
- Accuracy, J, 750...1200 ゚C
- ―
- Accuracy, T, -270...-200 ゚C
- ―
- Accuracy, T, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.1 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±6.0 ˚C
- Accuracy, T, 0...350 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±2.625 ˚C
- Accuracy, T, 350...400 ゚C
- ―
- Accuracy, N, -270...-200 ゚C
- ―
- Accuracy, N, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.2 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±11.0 ˚C
- Accuracy, N, 0...1250 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±9.375 ˚C
- Accuracy, N, 1250...1300 ゚C
- ―
- Accuracy, Cold junction compensation accuracy
- ±1.0 ˚C
- Sampling cycle
- 320 ms/8 channels
- Conversion speed
- 640 ms/8 channels
- Disconnection detection
- Available (each channel independent)
- Isolation method
- Between thermocouple input channel and programmable controller power supply: Transformer; Between thermocouple input channels: Transformer; Between cold junction compensation channel and programmable controller power supply: Non-isolation
- Dielectric withstand voltage
- Between thermocouple input channel and programmable controller power supply: 500 V AC rms for 1 minute; Between thermocouple input channels: 1000 V AC rms for 1 minute
- Insulation resistance
- Between thermocouple input channel and programmable controller power supply, between thermocouple input channels: 500 V DC, 10 MΩ or higher
- External interface,
- 40-pin connector
- External interface, Applicable connector
- A6CON1, A6CON2, A6CON4 (sold separately)
- Number of occupied I/O points
- 16 points (I/O assignment: Intelligent 16 points)
- Internal current consumption (5 V DC)
- 0.65 A
- External dimensions, Height
- 102 mm
- External dimensions, Width
- 27.4 mm
- External dimensions, Depth
- 130 mm
- Weight
- 0.22 kg
- General specifications
- Refer to the general specifications of the CPU module.
Technical documents (1)
Key features
- Number of analog input points: 8 points (8 channels + cold junction compensation channels)
- Number of channels: 8 channels
- Digital output, Scaling value: 16-bit signed binary value
- Thermocouple compliance standards: JIS C1602-1995, IEC 60584-1 (1995), IEC60584-2 (1982)
- Resolution: B, R, S, N: 0.3 ˚C; K, E, J, T: 0.1 ˚C
About the Mitsubishi Electric Q68TD-G-H02
The Mitsubishi Electric Q68TD-G-H02 is a MELSEC-Q analogue input module. Mitsubishi Electric's overview: 8 channels, thermocouple (B, R, S, K, E, J, T, N), conversion speed: 640 ms/8 channels, 40-pin connector, channel isolated, disconnection detection. Mitsubishi Electric names the R60TD8-G as its replacement model.
What is the Q68TD-G-H02 used for?
The Q68TD-G-H02 mounts on a MELSEC-Q base unit and connects field signals to the CPU, which reads or writes them each cycle.
Lifecycle and successor
Phased out.
OEM successor: R60TD8-G
Before you order
What to photograph or confirm so the right unit is quoted.
Check the model name Q68TD-G-H02 on the rating plate, with the serial number and function version. Send us a photo of the rating plate and we will confirm the details before quoting.
Alternatives for Q68TD-G-H02
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| R60TD8-GNamed by the manufacturer as the successor | Mitsubishi Electric | Analog input module | Active | OEM successor (upgrade path) | On Request | On request | View › |
| Mitsubishi Electric Q68AD-GMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68ADVMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68ADIMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAVNMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAVMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Discontinued | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAINMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAIMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Discontinued | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68CTMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q64TDV-GHMELSEC-Q Analogue input module, 4 analogue input channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68TD-G-H01MELSEC-Q Analogue input module, 8 channels, thermocouple (B, R, S, K, E, J, T, N) | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q64RDMELSEC-Q Analogue input module, 4 analogue input channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68RD3-GMELSEC-Q Analogue input module, 8 channels, RTD (Pt100, JPt100, Ni100) | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
You may also be interested in
Mitsubishi Electric
Mitsubishi Electric R16ENCPU
View ›Mitsubishi Electric
Mitsubishi Electric R32ENCPU
View ›
Mitsubishi Electric
Mitsubishi Electric R120ENCPU
View ›Mitsubishi Electric
Mitsubishi Electric R08PCPU
View ›Mitsubishi Electric
Mitsubishi Electric R16PCPU
View ›Mitsubishi Electric
Mitsubishi Electric R32PCPU
View ›
Mitsubishi Electric
Mitsubishi Electric R120PCPU
View ›
Mitsubishi Electric
Mitsubishi Electric L02SCPU
View ›Mitsubishi Electric
Mitsubishi Electric L02SCPU-P
View ›Mitsubishi Electric
Mitsubishi Electric L02CPU
View ›Mitsubishi Electric
Mitsubishi Electric L02CPU-P
View ›Mitsubishi Electric
Mitsubishi Electric L06CPU
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.