Mitsubishi Electric Q68TD-G-H01
MELSEC-Q Analogue input module, 8 channels, thermocouple (B, R, S, K, E, J, T, N)
Read from the product label
- Maker
- Mitsubishi Electric
- Part no.
- Q68TD-G-H01
- Serial / rev.
- as printed on your unit
Image is for illustrative purposes only. Please refer to product description.
Delivery options
Mitsubishi Electric Q68TD-G-H01 is a MELSEC-Q analogue input module with 8 analogue input channels and 320 ms/8 channels sampling.
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- Q68TD-G-H01
- Product family
- Mitsubishi MELSEC-Q I/O Modules
- Type
- Analog input module
- Category
- I/O modules › Analogue input and output modules
- Lifecycle
- Phased out
- OEM successor
- R60TD8-G
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Mitsubishi Electric
- Manufacturer part no.
- Q68TD-G-H01
- Type
- Analog input module
- Application
- I/O module
- Used with
- MELSEC-Q base units
- Number of analog input points
- 8 points (8 channels + cold junction compensation channels)
- Number of channels
- 8 channels
- Digital output, Temperature measured value
- 16-bit signed binary value (-2700...18200)
- Digital output, Scaling value
- 16-bit signed binary value
- Thermocouple compliance standards
- JIS C1602-1995, IEC 60584-1 (1995), IEC60584-2 (1982)
- Resolution
- B, R, S, N: 0.3 ˚C; K, E, J, T: 0.1 ˚C
- Accuracy, Thermocouple type, Measured temperature range
- Accuracy (℃) = (Conversion accuracy) + (Temperature characteristics); ; Conversion accuracy (at operating ambient temperature 25±5 ゚C); Temperature characteristic (per operating ambient temperature variation of 1 ゚C); Maximum temperature error at ambient temperature 55゚C; Effect per wiring resistance 1Ω
- Accuracy, B, 0...600 ゚C
- ―
- Accuracy, B, 600...800 ゚C
- Conversion accuracy: ±3.0 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±13.0 ˚C
- Accuracy, B, 800...1700 ゚C
- Conversion accuracy: ±2.5 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C
- Accuracy, B, 1700...1820 ゚C
- ―
- Accuracy, R, -50...0 ゚C
- ―
- Accuracy, R, 0...300 ゚C
- Conversion accuracy: ±2.5 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C
- Accuracy, R, 300...1600 ゚C
- Conversion accuracy: ±2.0 ˚C; Temperature characteristic: ±0.3 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±9.5 ˚C
- Accuracy, R, 1600...1760 ゚C
- ―
- Accuracy, S, -50...0 ゚C
- ―
- Accuracy, S, 0...300 ゚C
- Conversion accuracy: ±2.5 ˚C; Temperature characteristic: ±0.4 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±12.5 ˚C
- Accuracy, S, 300...1600 ゚C
- Conversion accuracy: ±2.0 ˚C; Temperature characteristic: ±0.3 ˚C; Maximum temperature error at ambient temperature 55 ゚C: ±9.5 ˚C
- Accuracy, S, 1600...1760 ゚C
- ―
- Accuracy, K, -270...-200 ゚C
- ―
- Accuracy, K, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.2 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±11.0 ˚C
- Accuracy, K, 0...1200 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±9.0 ˚C
- Accuracy, K, 1200...1370 ゚C
- ―
- Accuracy, E, -270...-200 ゚C
- ―
- Accuracy, E, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.15 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±8.5 ˚C
Show all 59 specificationsShow fewer
- Accuracy, E, 0...900 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±6.75 ˚C
- Accuracy, E, 900...1000 ゚C
- ―
- Accuracy, J, -210...-40 ゚C
- ―
- Accuracy, J, -40...750 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±5.625 ˚C
- Accuracy, J, 750...1200 ゚C
- ―
- Accuracy, T, -270...-200 ゚C
- ―
- Accuracy, T, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.1 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±6.0 ˚C
- Accuracy, T, 0...350 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±2.625 ˚C
- Accuracy, T, 350...400 ゚C
- ―
- Accuracy, N, -270...-200 ゚C
- ―
- Accuracy, N, -200...0 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.5 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.2 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±11.0 ˚C
- Accuracy, N, 0...1250 ゚C
- Conversion accuracy: Larger value of ±0.5 ˚C and ±0.25 % of measured temperature; Temperature characteristic: Larger value of ±0.06 ˚C and ±0.02 % of measured temperature; Maximum temperature error at ambient temperature 55 ゚C: ±9.375 ˚C
- Accuracy, N, 1250...1300 ゚C
- ―
- Accuracy, Cold junction compensation accuracy
- ±1.0 ˚C
- Sampling cycle
- 320 ms/8 channels
- Conversion speed
- 320 ms/8 channels
- Disconnection detection
- None
- Isolation method
- Between thermocouple input channel and programmable controller power supply: Transformer; Between thermocouple input channels: Transformer; Between cold junction compensation channel and programmable controller power supply: Non-isolation
- Dielectric withstand voltage
- Between thermocouple input channel and programmable controller power supply: 500 V AC rms for 1 minute; Between thermocouple input channels: 1000 V AC rms for 1 minute
- Insulation resistance
- Between thermocouple input channel and programmable controller power supply, between thermocouple input channels: 500 V DC, 10 MΩ or higher
- External interface,
- 40-pin connector
- External interface, Applicable connector
- A6CON1, A6CON2, A6CON4 (sold separately)
- Number of occupied I/O points
- 16 points (I/O assignment: Intelligent 16 points)
- Internal current consumption (5 V DC)
- 0.49 A
- External dimensions, Height
- 98 mm
- External dimensions, Width
- 27.4 mm
- External dimensions, Depth
- 90 mm
- Weight
- 0.18 kg
- General specifications
- Refer to the general specifications of the CPU module.
Technical documents (1)
Key features
- Number of analog input points: 8 points (8 channels + cold junction compensation channels)
- Number of channels: 8 channels
- Digital output, Scaling value: 16-bit signed binary value
- Thermocouple compliance standards: JIS C1602-1995, IEC 60584-1 (1995), IEC60584-2 (1982)
- Resolution: B, R, S, N: 0.3 ˚C; K, E, J, T: 0.1 ˚C
About the Mitsubishi Electric Q68TD-G-H01
The Mitsubishi Electric Q68TD-G-H01 is a MELSEC-Q analogue input module. Mitsubishi Electric's overview: 8 channels, thermocouple (B, R, S, K, E, J, T, N), conversion speed: 320 ms/8 channels, 40-pin connector, channel isolated, disconnection monitoring. Mitsubishi Electric names the R60TD8-G as its replacement model.
What is the Q68TD-G-H01 used for?
The Q68TD-G-H01 mounts on a MELSEC-Q base unit and connects field signals to the CPU, which reads or writes them each cycle.
Lifecycle and successor
Phased out.
OEM successor: R60TD8-G
Before you order
What to photograph or confirm so the right unit is quoted.
Check the model name Q68TD-G-H01 on the rating plate, with the serial number and function version. Send us a photo of the rating plate and we will confirm the details before quoting.
Alternatives for Q68TD-G-H01
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| R60TD8-GNamed by the manufacturer as the successor | Mitsubishi Electric | Analog input module | Active | OEM successor (upgrade path) | On Request | On request | View › |
| Mitsubishi Electric Q68AD-GMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68ADVMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68ADIMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAVNMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAVMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Discontinued | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAINMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68DAIMELSEC-Q Analogue output module, 8 analogue output channels | Mitsubishi Electric | Analog output module | Discontinued | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68CTMELSEC-Q Analogue input module, 8 channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q64TDMELSEC-Q Analogue input module, 4 channels, thermocouple (B, R, S, K, E, J, T, N) | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q64TDV-GHMELSEC-Q Analogue input module, 4 analogue input channels | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68TD-G-H02MELSEC-Q Analogue input module, 8 channels, thermocouple (B, R, S, K, E, J, T, N) | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
| Mitsubishi Electric Q68RD3-GMELSEC-Q Analogue input module, 8 channels, RTD (Pt100, JPt100, Ni100) | Mitsubishi Electric | Analog input module | Phased out | Same family | On Request | On request | View › |
You may also be interested in
Mitsubishi Electric
Mitsubishi Electric Q13UDEHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q20UDEHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q26UDEHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q50UDEHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q100UDEHCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q00JCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q00JCPU-E
View ›Mitsubishi Electric
Mitsubishi Electric Q00CPU
View ›Mitsubishi Electric
Mitsubishi Electric Q01CPU
View ›Mitsubishi Electric
Mitsubishi Electric Q02CPU
View ›Mitsubishi Electric
Mitsubishi Electric Q02HCPU
View ›Mitsubishi Electric
Mitsubishi Electric Q06HCPU
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.