- Manufacturer
- Siemens
- Manufacturer part number
- 6ES7515-2AN03-0AB0
- Product family
- SIMATIC S7-1500 PLC
- Category
- PLCs and I/O › CPU and processor modules
- Technical datasheet
- Data sheet
Specifications
| Attribute | Value |
|---|---|
| Type | PLC CPU |
| Manufacturer lifecycle | Active |
| Product type designation | CPU 1515-2 PN |
| HW functional status | FS04 |
| Firmware version | V4.1 |
| Firmware version / FW update possible | Yes |
| Product function / I&M data | Yes; I&M0 to I&M3 |
| Product function / Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central) |
| Product function / SysLog | Yes |
| Engineering with / STEP 7 TIA Portal configurable/integrated from version | V21 (FW V4.1) / V18 (FW V3.0) or higher; configurable with older TIA Portal versions as 6ES7515-2AM02-0AB0 |
| Configuration control / via dataset | Yes |
| Display / Screen diagonal [cm] | 6.1 cm |
| Control elements / Number of keys | 8 |
| Control elements / Mode buttons | 2 |
| Supply voltage / Rated value (DC) | 24 V |
Show all 326 specificationsShow fewer specifications
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
|---|---|
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Supply voltage / Reverse polarity protection | Yes |
| Mains buffering / Mains/voltage failure stored energy time | 5 ms |
| Mains buffering / Repeat rate, min. | 1/s |
| Input current / Current consumption (rated value) | 0.65 A |
| Input current / Current consumption, max. | 1.03 A |
| Input current / Inrush current, max. | 1.15 A; Rated value |
| Input current / I²t | 0.6 A²·s |
| Infeed power to the backplane bus | 12 W |
| Power consumption from the backplane bus (balanced) | 6.2 W |
| Power loss, typ. | 3.6 W |
| Storage / Number of slots for SIMATIC memory card | 1 |
| Storage / SIMATIC memory card required | Yes |
| Work memory / integrated (for program) | 1 Mbyte |
| Work memory / integrated (for data) | 4.5 Mbyte |
| Load memory / Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
| Backup / maintenance-free | Yes |
| CPU processing times / for bit operations, typ. | 6 ns |
| CPU processing times / for word operations, typ. | 7 ns |
| CPU processing times / for fixed point arithmetic, typ. | 9 ns |
| CPU processing times / for floating point arithmetic, typ. | 37 ns |
| CPU-blocks / Number of elements (total) | 8 000; Blocks (OB, FB, FC, DB) and UDTs |
| DB / Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 |
| DB / Size, max. | 4.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
| FB / Number range | 0 ... 65 535 |
| FB / Size, max. | 1 Mbyte |
| FC / Number range | 0 ... 65 535 |
| FC / Size, max. | 1 Mbyte |
| OB / Size, max. | 1 Mbyte |
| OB / Number of free cycle OBs | 100 |
| OB / Number of time alarm OBs | 20 |
| OB / Number of delay alarm OBs | 20 |
| OB / Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 250 µs |
| OB / Number of process alarm OBs | 50 |
| OB / Number of DPV1 alarm OBs | 3 |
| OB / Number of isochronous mode OBs | 2 |
| OB / Number of startup OBs | 100 |
| OB / Number of asynchronous error OBs | 4 |
| OB / Number of synchronous error OBs | 2 |
| OB / Number of diagnostic alarm OBs | 1 |
| Nesting depth / per priority class | 24 |
| S7 counter / Number | 2 048 |
| S7 counter / Retentivity / adjustable | Yes |
| IEC counter / Number | Any (only limited by the main memory) |
| IEC counter / Retentivity / adjustable | Yes |
| S7 timer / Number | 2 048 |
| S7 timer / Retentivity / adjustable | Yes |
| IEC timer / Number | Any (only limited by the main memory) |
| IEC timer / Retentivity / can be set | Yes |
| Retentive data area (incl. timers, counters, flags), max. | 472 kbyte; in total; for bit memories, timers, counters, DBs, and technology data (axes) |
| Extended retentive data area (incl. timers, counters, flags), max. | 4.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF |
| Flag / Size, max. | 16 kbyte |
| Flag / Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data blocks / Retentivity adjustable | Yes |
| Data blocks / Retentivity preset | No |
| Local data / per priority class, max. | 64 kbyte; max. 16 KB per block |
| Address area / Number of IO modules | 8 192; max. number of modules / submodules |
| I/O address area / Inputs | 32 kbyte; All inputs are in the process image |
| I/O address area / Outputs | 32 kbyte; All outputs are in the process image |
| I/O address area / per integrated IO subsystem / Inputs (volume) | 8 kbyte |
| I/O address area / per integrated IO subsystem / Outputs (volume) | 8 kbyte |
| I/O address area / per CM/CP / Inputs (volume) | 8 kbyte |
| I/O address area / per CM/CP / Outputs (volume) | 8 kbyte |
| Subprocess images / Number of subprocess images, max. | 32 |
| Hardware configuration / Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
| Number of DP masters / Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
| Number of IO Controllers / Integrated | 2 |
| Number of IO Controllers / via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
| Rack / Modules per rack, max. | 32; CPU + 31 modules |
| Rack / Number of lines, max. | 1 |
| PtP CM / Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
| Clock / Type | Hardware clock |
| Clock / Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Clock / Deviation per day, max. | 10 s; Typ.: 2 s |
| Operating hours counter / Number | 64 |
| Clock synchronization / supported | Yes |
| Clock synchronization / to DP, master | Yes; via PROFIBUS CM / CP |
| Clock synchronization / on DP, device | Yes; via PROFIBUS CM / CP |
| Clock synchronization / in AS, master | Yes |
| Clock synchronization / in AS, device | Yes |
| Clock synchronization / on Ethernet via NTP | Yes |
| Number of PROFINET interfaces | 2 |
| 1. Interface / Interface types / RJ 45 (Ethernet) | Yes; X1 |
| 1. Interface / Interface types / Number of ports | 2 |
| 1. Interface / Interface types / integrated switch | Yes |
| Protocols / IP protocol | Yes; IPv4 |
| Protocols / PROFINET IO Controller | Yes |
| Protocols / PROFINET IO device | Yes |
| Protocols / SIMATIC communication | Yes |
| Protocols / Open IE communication | Yes; Optionally also encrypted |
| Protocols / Web server | Yes |
| 1. Interface / Protocols / Media redundancy | Yes |
| 1. Interface / PROFINET IO Controller / Services / Isochronous mode | Yes |
| 1. Interface / PROFINET IO Controller / Services / Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| 1. Interface / PROFINET IO Controller / Services / IRT | Yes |
| 1. Interface / PROFINET IO Controller / Services / Dynamic Frame Packing (DFP) | Yes |
| PROFINET IO Controller / Services / PROFIenergy | Yes; per user program |
| 1. Interface / PROFINET IO Controller / Services / Prioritized startup | Yes; Max. 32 PROFINET devices |
| 1. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. | 256; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| PROFINET IO Controller / Services / Of which IO devices with IRT, max. | 64 |
| 1. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. | 256 |
| 1. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max. | 256 |
| PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
| PROFINET IO Controller / Services / Number of IO Devices per tool, max. | 8 |
| PROFINET IO Controller / Services / Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| PROFINET IO Controller / Update time for IRT / for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive |
| PROFINET IO Controller / Update time for IRT / for send cycle of 500 µs | 500 µs to 8 ms |
| PROFINET IO Controller / Update time for IRT / for send cycle of 1 ms | 1 ms to 16 ms |
| PROFINET IO Controller / Update time for IRT / for send cycle of 2 ms | 2 ms to 32 ms |
| PROFINET IO Controller / Update time for IRT / for send cycle of 4 ms | 4 ms to 64 ms |
| PROFINET IO Controller / Update time for IRT / With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) |
| PROFINET IO Controller / Update time for RT / for send cycle of 250 µs | 250 µs to 128 ms |
| PROFINET IO Controller / Update time for RT / for send cycle of 500 µs | 500 µs to 256 ms |
| PROFINET IO Controller / Update time for RT / for send cycle of 1 ms | 1 ms to 512 ms |
| PROFINET IO Controller / Update time for RT / for send cycle of 2 ms | 2 ms to 512 ms |
| PROFINET IO Controller / Update time for RT / for send cycle of 4 ms | 4 ms to 512 ms |
| PROFINET IO Device / Services / Isochronous mode | No |
| 1. Interface / PROFINET IO Device / Services / IRT | Yes |
| PROFINET IO Device / Services / Dynamic Frame Packing (DFP) | No |
| PROFINET IO Device / Services / PROFIenergy | Yes; per user program |
| 1. Interface / PROFINET IO Device / Services / Prioritized startup | Yes |
| PROFINET IO Device / Services / Shared device | Yes |
| PROFINET IO Device / Services / Number of IO Controllers with shared device, max. | 4 |
| PROFINET IO Device / Services / activation/deactivation of I-devices | Yes; per user program |
| PROFINET IO Device / Services / Asset management record | Yes; per user program |
| 2. Interface / Interface types / RJ 45 (Ethernet) | Yes; X2 |
| 2. Interface / Interface types / Number of ports | 1 |
| 2. Interface / Interface types / integrated switch | No |
| Protocols / PROFINET IO Device | Yes |
| 2. Interface / Protocols / Media redundancy | No |
| 2. Interface / PROFINET IO Controller / Services / Isochronous mode | No |
| 2. Interface / PROFINET IO Controller / Services / Direct data exchange | No |
| 2. Interface / PROFINET IO Controller / Services / IRT | No |
| 2. Interface / PROFINET IO Controller / Services / Dynamic Frame Packing (DFP) | No |
| 2. Interface / PROFINET IO Controller / Services / Prioritized startup | No |
| 2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. | 32; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
| 2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. | 32 |
| 2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max. | 32 |
| PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supported | Yes |
| PROFINET IO Controller / Services / PROFINET Security Class | 1 |
| 2. Interface / PROFINET IO Device / Services / IRT | No |
| 2. Interface / PROFINET IO Device / Services / Prioritized startup | No |
| PROFINET IO Device / Services / PROFINET Security Class | SNMP Configuration and DCP Read Only |
| RJ 45 (Ethernet) / 100 Mbps | Yes |
| RJ 45 (Ethernet) / Autonegotiation | Yes |
| RJ 45 (Ethernet) / Autocrossing | Yes |
| RJ 45 (Ethernet) / Industrial Ethernet status LED | Yes |
| Protocols / PROFIsafe | No |
| Number of connections / Number of connections, max. | 256; via integrated interfaces of the CPU and connected CPs / CMs |
| Number of connections / Number of connections reserved for ES/HMI/web | 10 |
| Number of connections / Number of connections via integrated interfaces | 128 |
| Number of connections / Number of S7 routing paths | 16 |
| Redundancy mode / PROFINET system redundancy (S2) | No |
| Redundancy mode / PROFINET system redundancy (R1) | No |
| Redundancy mode / H-Sync forwarding | Yes |
| Redundancy mode / Media redundancy / Media redundancy | only via 1st interface (X1) |
| Redundancy mode / Media redundancy / MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
| Redundancy mode / Media redundancy / MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
| Redundancy mode / Media redundancy / MRPD | Yes; Requirement: IRT |
| Redundancy mode / Media redundancy / Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| Redundancy mode / Media redundancy / Number of stations in the ring, max. | 50 |
| SIMATIC communication / PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| SIMATIC communication / S7 routing | Yes |
| SIMATIC communication / Data record routing | Yes |
| SIMATIC communication / S7 communication, as server | Yes |
| SIMATIC communication / S7 communication, as client | Yes |
| SIMATIC communication / User data per job, max. | See online help (S7 communication, user data size) |
| Open IE communication / TCP/IP | Yes |
| Open IE communication / TCP/IP / Data length, max. | 64 kbyte |
| Open IE communication / TCP/IP / several passive connections per port, supported | Yes |
| Open IE communication / ISO-on-TCP (RFC1006) | Yes |
| Open IE communication / ISO-on-TCP (RFC1006) / Data length, max. | 64 kbyte |
| Open IE communication / UDP | Yes |
| Open IE communication / UDP / Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
| Open IE communication / UDP / UDP multicast | Yes; max. 118 multicast circuits |
| Open IE communication / DHCP | Yes |
| Open IE communication / DNS | Yes |
| Open IE communication / SNMP | Yes |
| Open IE communication / DCP | Yes |
| Open IE communication / LLDP | Yes |
| Open IE communication / Encryption | Yes; Optional |
| Web server / HTTP | Yes; Standard and user pages |
| Web server / HTTPS | Yes; Standard and user pages |
| Web server / web API / Number of sessions, max. | 100 |
| Web server / web API / number of simultaneous HTTP calls, max. | 4 |
| Web server / web API / HTTP request body, max. | 131 072 byte |
| OPC UA / Runtime license required | Yes; "Medium" license required |
| OPC UA / OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
| OPC UA / OPC UA Client / Application authentication | Yes |
| OPC UA / OPC UA Client / Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| OPC UA / OPC UA Client / User authentication | "anonymous" or by user name & password |
| OPC UA / OPC UA Client / Number of connections, max. | 10 |
| OPC UA / OPC UA Client / Number of nodes of the client interfaces, recommended max. | 2 000 |
| OPC UA / OPC UA Client / Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. | 300 |
| OPC UA / OPC UA Client / Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
| OPC UA / OPC UA Client / Number of elements for one call of OPC_UA_MethodGetHandleList, max. | 100 |
| OPC UA / OPC UA Client / Number of simultaneous calls of the client instructions for session management, per connection, max. | 1 |
| OPC UA / OPC UA Client / Number of simultaneous calls of the client instructions for data access, per connection, max. | 5; for OPC_UA_MethodCall 100 in total (no limit per connection) |
| OPC UA / OPC UA Client / Number of registerable nodes, max. | 5 000 |
| OPC UA / OPC UA Client / Number of registerable method calls of OPC_UA_MethodCall, max. | 100 |
| OPC UA / OPC UA Client / Number of inputs/outputs when calling OPC_UA_MethodCall, max. | 20 |
| OPC UA / OPC UA Client / OPC UA Server | Yes; data access (read, write, subscribe), method call, alarms & condition (A&C), custom address space, role-based access control |
| OPC UA / OPC UA Client / OPC UA Server / Application authentication | Yes |
| OPC UA / OPC UA Client / OPC UA Server / Security policies | available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss |
| OPC UA / OPC UA Client / OPC UA Server / User authentication | "anonymous" or by user name & password |
| OPC UA / OPC UA Client / OPC UA Server / GDS support (certificate management) | Yes |
| OPC UA / OPC UA Client / OPC UA Server / Number of sessions, max. | 48 |
| OPC UA / OPC UA Client / OPC UA Server / Number of accessible variables, max. | 100 000 |
| OPC UA / OPC UA Client / OPC UA Server / Number of registerable nodes, max. | 20 000 |
| OPC UA / OPC UA Client / OPC UA Server / Number of subscriptions per session, max. | 50 |
| OPC UA / OPC UA Client / OPC UA Server / Sampling interval, min. | 100 ms |
| OPC UA / OPC UA Client / OPC UA Server / Publishing interval, min. | 100 ms |
| OPC UA / OPC UA Client / OPC UA Server / Number of server methods, max. | 1 000; max. 50 concurrently running jobs each for asynchronous instructions OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost |
| OPC UA / OPC UA Client / OPC UA Server / Number of inputs/outputs per server method, max. | 20 |
| OPC UA / OPC UA Client / OPC UA Server / Number of monitored items, recommended max. | 4 000; for 1 s sampling interval and 1 s send interval |
| OPC UA / OPC UA Client / OPC UA Server / Number of server interfaces, max. | 10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace" |
| OPC UA / OPC UA Client / OPC UA Server / Number of nodes for user-defined server interfaces, max. | 30 000 |
| OPC UA / OPC UA Client / Alarms and Conditions | Yes |
| OPC UA / OPC UA Client / Alarms and Conditions / Number of program alarms | 200 |
| OPC UA / OPC UA Client / Alarms and Conditions / Number of alarms for system diagnostics | 100 |
| OPC UA / Further protocols / MODBUS | Yes; MODBUS TCP |
| S7 message functions / Number of login stations for message functions, max. | 64 |
| S7 message functions / number of subscriptions, max. | 500 |
| S7 message functions / number of tags/attributes for subscriptions, max. | 8 000 |
| S7 message functions / Program alarms | Yes |
| S7 message functions / Number of configurable program messages, max. | 10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH |
| S7 message functions / Number of loadable program messages in RUN, max. | 10 000 |
| Number of simultaneously active program alarms / Number of program alarms | 1 000 |
| Number of simultaneously active program alarms / Number of alarms for system diagnostics | 200 |
| Number of simultaneously active program alarms / Number of alarms for motion technology objects | 160 |
| Test commissioning functions / Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems |
| Test commissioning functions / Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
| Test commissioning functions / Single step | No |
| Test commissioning functions / Number of breakpoints | 8 |
| Test commissioning functions / Profiling | Yes |
| Status/control / Status/control variable | Yes |
| Status/control / Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Status/control / Number of variables, max. / of which status variables, max. | 200; per job |
| Status/control / Number of variables, max. / of which control variables, max. | 200; per job |
| Forcing / Forcing | Yes |
| Forcing / Forcing, variables | Peripheral inputs/outputs |
| Forcing / Number of variables, max. | 200 |
| Diagnostic buffer / present | Yes |
| Diagnostic buffer / Number of entries, max. | 3 200 |
| Diagnostic buffer / Number of entries, max. / of which powerfail-proof | 500 |
| Traces / Number of configurable Traces | 4 |
| Traces / Memory size per trace, max. | 512 kbyte |
| Diagnostics indication LED / RUN/STOP LED | Yes |
| Diagnostics indication LED / ERROR LED | Yes |
| Diagnostics indication LED / MAINT LED | Yes |
| Diagnostics indication LED / STOP ACTIVE LED | Yes |
| Diagnostics indication LED / Connection display LINK TX/RX | Yes |
| Supported technology objects / Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
| Motion Control / Number of available Motion Control resources for technology objects | 2 400 |
| Motion Control / Required Motion Control resources / per speed-controlled axis | 40 |
| Motion Control / Required Motion Control resources / per positioning axis | 80 |
| Motion Control / Required Motion Control resources / per synchronous axis | 160 |
| Motion Control / Required Motion Control resources / per external encoder | 80 |
| Motion Control / Required Motion Control resources / per output cam | 20 |
| Motion Control / Required Motion Control resources / per cam track | 160 |
| Motion Control / Required Motion Control resources / per probe | 40 |
| Motion Control / Positioning axis / Number of positioning axes at motion control cycle of 4 ms (typical value) | 11 |
| Motion Control / Positioning axis / Number of positioning axes at motion control cycle of 8 ms (typical value) | 20 |
| Controller / PID_Compact | Yes; Universal PID controller with integrated optimization |
| Controller / PID_3Step | Yes; PID controller with integrated optimization for valves |
| Controller / PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring / High-speed counter | Yes |
| Standards, approvals, certificates / Siemens Eco Profile (SEP) | Siemens EcoTech |
| Standards, approvals, certificates / Recycler Guide available | Yes |
| Ecological footprint / environmental product declaration | Yes |
| Ecological footprint / Global warming potential / global warming potential, (total) [CO2 eq] | 100 kg |
| Ecological footprint / Global warming potential / global warming potential, (during production) [CO2 eq] | 25.8 kg |
| Ecological footprint / Global warming potential / global warming potential, (during operation) [CO2 eq] | 75.2 kg |
| Ecological footprint / Global warming potential / global warming potential, (after end of life cycle) [CO2 eq] | -0.83 kg |
| PROFINET Security Class | 1 |
| Security / signed firmware update | Yes |
| Security / Secure Boot | Yes |
| Security / securely removing data | Yes |
| Ambient temperature during operation / horizontal installation, min. | -30 °C; No condensation |
| Ambient temperature during operation / horizontal installation, max. | 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off |
| Ambient temperature during operation / vertical installation, min. | -30 °C; No condensation |
| Ambient temperature during operation / vertical installation, max. | 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
| Ambient temperature during storage/transportation / min. | -40 °C |
| Ambient temperature during storage/transportation / max. | 70 °C |
| Altitude during operation relating to sea level / Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Programming / Programming language / LAD | Yes |
| Programming / Programming language / FBD | Yes |
| Programming / Programming language / STL | Yes |
| Programming / Programming language / SCL | Yes |
| Programming / Programming language / CFC | Yes |
| Programming / Programming language / GRAPH | Yes |
| Know-how protection / User program protection/password protection | Yes |
| Know-how protection / Copy protection | Yes |
| Know-how protection / Block protection | Yes |
| Access protection / protection of confidential configuration data | Yes |
| Access protection / Password for display | Yes |
| Access protection / Protection level: Write protection | Yes |
| Access protection / Protection level: Read/write protection | Yes |
| Access protection / Protection level: Write protection for Failsafe | No |
| Access protection / Protection level: Complete protection | Yes |
| Access protection / User administration | Yes; device-wide and centralized |
| Access protection / Number of users | 100 |
| Access protection / Number of groups | 100 |
| Access protection / Number of roles | 50 |
| Cycle time monitoring / lower limit | adjustable minimum cycle time |
| Cycle time monitoring / upper limit | adjustable maximum cycle time |
| Width | 70 mm |
| Height | 147 mm |
| Depth | 129 mm |
| Weight, approx. | 456 g |
Description
The Siemens 6ES7515-2AN03-0AB0 is the S7-1500 CPU 1515-2 PN. Siemens's data sheet gives 1 MB of work memory for the program and 4.5 MB for data, two PROFINET interfaces (IRT with a two-port switch, and RT), 6 ns per bit operation, and configuration in STEP 7 TIA Portal; it needs a SIMATIC Memory Card. SiePortal lists it as an active product.
Application: PLC controller
Used with: S7-1500 and ET 200MP modules
What is the 6ES7515-2AN03-0AB0 used for?
It controls machines and lines as the central CPU of an S7-1500 station, and is one of the CPUs an S7-300 can be migrated to.
Key features
- 1 MB work memory for program, 4.5 MB for data
- PROFINET IRT with 2-port switch, plus a second PROFINET RT interface
- 6 ns per bit operation
- Programmed in STEP 7 TIA Portal
- Needs a SIMATIC Memory Card
Documents and Resources
Associated Products
| Image | Product | Description | Stock | View | Add to RFQ |
|---|---|---|---|---|---|
![]() | 6ES7531-7KF00-0AB0Siemens | AI 8xU/I/RTD/TC ST analog input module, 16 bit | In stock | View | |
![]() | 6ES7592-1AM00-0XB0Siemens | Front connector, 40-pole, screw, for 35 mm modules | In stock | View |
Product Questions
Is the 6ES7515-2AN03-0AB0 discontinued?
No. Its manufacturer lifecycle status is Active.
Can another Siemens SIMATIC S7-1500 part replace it?
Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.