Image is for illustrative purposes only. Please refer to product description.
- Manufacturer
- Siemens
- Manufacturer part number
- 6ES7331-1KF02-0AB0
- Product family
- SIMATIC S7-300 PLC Modules
- Category
- PLCs and I/O › Analog I/O modules
- Technical datasheet
- Data sheet
Specifications
| Attribute | Value |
|---|---|
| Type | Analog module |
| Manufacturer lifecycle | Discontinued |
| Product function / Isochronous mode | No |
| Input current / from backplane bus 5 V DC, max. | 90 mA |
| Power loss, typ. | 0.4 W |
| Number of analog inputs | 8 |
| Number of analog inputs / For resistance measurement | 8 |
| Analog inputs / permissible input voltage for voltage input (destruction limit), max. | 30 V; 12 V continuous, 30 V for max. 1 s |
| Analog inputs / permissible input current for current input (destruction limit), max. | 40 mA |
| Input ranges / Voltage | Yes |
| Input ranges / Current | Yes |
| Input ranges / Thermocouple | No |
| Input ranges / Resistance thermometer | Yes |
| Input ranges / Resistance | Yes |
| Input ranges (rated values), voltages / 0 to +10 V | Yes |
Show all 114 specificationsShow fewer specifications
| Input ranges (rated values), voltages / 0 to +10 V / Input resistance (0 to 10 V) | 100 kΩ |
|---|---|
| Input ranges (rated values), voltages / 1 V to 5 V | Yes |
| Input ranges (rated values), voltages / 1 V to 5 V / Input resistance (1 V to 5 V) | 100 kΩ |
| Input ranges (rated values), voltages / 1 V to 10 V | No |
| Input ranges (rated values), voltages / -1 V to +1 V | Yes |
| Input ranges (rated values), voltages / -1 V to +1 V / Input resistance (-1 V to +1 V) | 100 kΩ |
| Input ranges (rated values), voltages / -10 V to +10 V | Yes |
| Input ranges (rated values), voltages / -10 V to +10 V / Input resistance (-10 V to +10 V) | 100 kΩ |
| Input ranges (rated values), voltages / -2.5 V to +2.5 V | No |
| Input ranges (rated values), voltages / -250 mV to +250 mV | No |
| Input ranges (rated values), voltages / -5 V to +5 V | Yes |
| Input ranges (rated values), voltages / -5 V to +5 V / Input resistance (-5 V to +5 V) | 100 kΩ |
| Input ranges (rated values), voltages / -50 mV to +50 mV | Yes |
| Input ranges (rated values), voltages / -50 mV to +50 mV / Input resistance (-50 mV to +50 mV) | 100 kΩ |
| Input ranges (rated values), voltages / -500 mV to +500 mV | Yes |
| Input ranges (rated values), voltages / -500 mV to +500 mV / Input resistance (-500 mV to +500 mV) | 100 kΩ |
| Input ranges (rated values), voltages / -80 mV to +80 mV | No |
| Input ranges (rated values), currents / 0 to 20 mA | Yes |
| Input ranges (rated values), currents / 0 to 20 mA / Input resistance (0 to 20 mA) | 100 Ω |
| Input ranges (rated values), currents / -10 mA to +10 mA | No |
| Input ranges (rated values), currents / -20 mA to +20 mA | Yes |
| Input ranges (rated values), currents / -20 mA to +20 mA / Input resistance (-20 mA to +20 mA) | 100 Ω |
| Input ranges (rated values), currents / -3.2 mA to +3.2 mA | No |
| Input ranges (rated values), currents / 4 mA to 20 mA | Yes |
| Input ranges (rated values), currents / 4 mA to 20 mA / Input resistance (4 mA to 20 mA) | 100 Ω |
| Input ranges (rated values), thermocouples / Type B | No |
| Input ranges (rated values), thermocouples / Type C | No |
| Input ranges (rated values), thermocouples / Type E | No |
| Input ranges (rated values), thermocouples / Type J | No |
| Input ranges (rated values), thermocouples / Type K | No |
| Input ranges (rated values), thermocouples / Type L | No |
| Input ranges (rated values), thermocouples / Type N | No |
| Input ranges (rated values), thermocouples / Type R | No |
| Input ranges (rated values), thermocouples / Type S | No |
| Input ranges (rated values), thermocouples / Type T | No |
| Input ranges (rated values), thermocouples / Type U | No |
| Input ranges (rated values), thermocouples / Type TXK/TXK(L) to GOST | No |
| Input ranges (rated values), resistance thermometer / Cu 10 | No |
| Input ranges (rated values), resistance thermometer / Ni 100 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer / Ni 100 / Input resistance (Ni 100) | 100 MΩ |
| Input ranges (rated values), resistance thermometer / Ni 1000 | Yes |
| Input ranges (rated values), resistance thermometer / Ni 1000 / Input resistance (Ni 1000) | 100 MΩ |
| Input ranges (rated values), resistance thermometer / LG-Ni 1000 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer / LG-Ni 1000 / Input resistance (LG-Ni 1000) | 100 MΩ |
| Input ranges (rated values), resistance thermometer / Ni 120 | No |
| Input ranges (rated values), resistance thermometer / Ni 200 | No |
| Input ranges (rated values), resistance thermometer / Ni 500 | No |
| Input ranges (rated values), resistance thermometer / Pt 100 | Yes; Standard/climate |
| Input ranges (rated values), resistance thermometer / Pt 100 / Input resistance (Pt 100) | 100 MΩ |
| Input ranges (rated values), resistance thermometer / Pt 1000 | No |
| Input ranges (rated values), resistance thermometer / Pt 200 | No |
| Input ranges (rated values), resistance thermometer / Pt 500 | No |
| Input ranges (rated values), resistors / 0 to 150 ohms | No |
| Input ranges (rated values), resistors / 0 to 300 ohms | No |
| Input ranges (rated values), resistors / 0 to 600 ohms | Yes |
| Input ranges (rated values), resistors / 0 to 600 ohms / Input resistance (0 to 600 ohms) | 100 MΩ |
| Input ranges (rated values), resistors / 0 to 6000 ohms | Yes |
| Input ranges (rated values), resistors / 0 to 6000 ohms / Input resistance (0 to 6000 ohms) | 100 MΩ |
| Thermocouple (TC) / Temperature compensation / Parameterizable | No |
| Thermocouple (TC) / Temperature compensation / internal temperature compensation | No |
| Thermocouple (TC) / Temperature compensation / external temperature compensation with compensations socket | No |
| Characteristic linearization / Parameterizable | Yes |
| Characteristic linearization / Parameterizable / for thermocouples | No |
| Characteristic linearization / Parameterizable / for resistance thermometer | yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con. |
| Cable length / shielded, max. | 200 m; max. 50 m at 50 mV |
| Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 13 bit |
| Integration and conversion time/resolution per channel / Integration time, parameterizable | Yes; 60 / 50 ms |
| Integration and conversion time/resolution per channel / Basic conversion time (ms) | 66 / 55 ms |
| Integration and conversion time/resolution per channel / Interference voltage suppression for interference frequency f1 in Hz | 50 / 60 Hz |
| Connection of signal encoders / for voltage measurement | Yes |
| Connection of signal encoders / for current measurement as 2-wire transducer | Yes; with external supply |
| Connection of signal encoders / for current measurement as 4-wire transducer | Yes |
| Connection of signal encoders / for resistance measurement with two-wire connection | Yes |
| Connection of signal encoders / for resistance measurement with three-wire connection | Yes |
| Connection of signal encoders / for resistance measurement with four-wire connection | Yes |
| Operational error limit in overall temperature range / Voltage, relative to input range, (+/-) | 0.6 %; ±0.6 % (±5 V, 10 V, 1 to 5 V, 0 to 10 V); ±0.5 % (±50 mV, 500 mV, 1 V) |
| Operational error limit in overall temperature range / Current, relative to input range, (+/-) | 0.5 %; ±20 mA, 0 to 20 mA, 4 to 20 mA |
| Operational error limit in overall temperature range / Resistance, relative to input range, (+/-) | 0.5 %; 0 to 6 kohms, 0 to 600 kohms |
| Operational error limit in overall temperature range / Resistance thermometer, relative to input range, (+/-) | 1 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG- Ni1000, climatic); 1.2 Kelvin (Pt100, Ni100, standard) |
| Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-) | 0.4 %; 0.4% (±5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (±50 mV, 500 mV, 1 V) |
| Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-) | 0.3 %; ±20 mA, 0 to 20 mA, 4 to 20 mA |
| Basic error limit (operational limit at 25 °C) / Resistance, relative to input range, (+/-) | 0.3 %; 0 to 6 kohms, 0 to 600 kohms |
| Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-) | 1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic) |
| Interrupts/diagnostics/status information / Diagnostics function | No |
| Alarms / Diagnostic alarm | No |
| Alarms / Limit value alarm | No |
| Diagnoses / Diagnostic information readable | No |
| Diagnostics indication LED / Group error SF (red) | No |
| Potential separation analog inputs / between the channels | No |
| Potential separation analog inputs / between the channels and backplane bus | Yes |
| Isolation tested with | 500 V DC |
| required front connector | 40-pin |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 117 mm |
| Weight, approx. | 250 g |
| Phase-out announced (PM400) | 1 October 2023 |
| Product cancellation (PM410) | 1 October 2025 |
| Spare part | Yes, supplied by Siemens as a spare part only |
Description
The Siemens 6ES7331-1KF02-0AB0 is an eight-channel SM 331 analog input module with 13-bit resolution. Siemens describes it for voltage, current, resistance, Pt100, Ni100, Ni1000, LG-Ni1000 and PTC/KTY inputs with a 66 ms conversion time, isolated, with a 40-pin front connector. Siemens's data sheet marks it as a spare part. Siemens names no direct successor for the order number; its route forward is migration to the S7-1500 with ET 200MP.
Application: Analog I/O module
Used with: SIMATIC S7-300 rack (S7-300 backplane bus)
What is the 6ES7331-1KF02-0AB0 used for?
It reads temperatures from resistance thermometers and standard process signals in building services and process plant.
Key features
- 8 analog inputs, 13-bit
- Voltage, current, resistance, Pt100, Ni100, Ni1000, LG-Ni1000, PTC/KTY
- All 8 inputs usable for resistance measurement
- Isolated; 40-pin front connector
- Discontinued by Siemens on 1 October 2025; spare part only
Documents and Resources
Associated Products
| Image | Product | Description | Stock | View | Add to RFQ |
|---|---|---|---|---|---|
![]() | 6ES7331-7KF02-0AB0Siemens | SM 331 analog input, 8 AI, U/I/thermocouple/resistance | In stock | View | |
![]() | 6ES7332-5HF00-0AB0Siemens | SM 332 analog output, 8 AO, voltage/current | In stock | View | |
![]() | 6ES7331-7KB02-0AB0Siemens | SM 331 analog input, 2 AI, U/I/thermocouple/resistance | In stock | View | |
![]() | 6ES7331-7NF00-0AB0Siemens | SM 331 analog input, 8 AI, 16 bit, U/I | In stock | View | |
![]() | 6ES7331-7PF01-0AB0Siemens | SM 331 analog input, 8 AI, RTD, 16 bit | In stock | View | |
![]() | 6ES7332-5HD01-0AB0Siemens | SM 332 analog output, 4 AO, voltage/current | In stock | View | |
![]() | 6ES7334-0KE00-0AB0Siemens | SM 334 analog module, 4 AI / 2 AO, 12 bit | In stock | View | |
![]() | 6ES7331-7NF10-0AB0Siemens | SM 331 analog input, 8 AI, 16 bit, U/I, 4-channel fast mode | In stock | View | |
![]() | 6ES7331-7HF01-0AB0Siemens | SM 331 analog input, 8 AI, 14 bit, 52 µs per channel | In stock | View | |
![]() | 6ES7331-7PF11-0AB0Siemens | SM 331 analog input, 8 AI, thermocouples, 16 bit | In stock | View | |
![]() | 6ES7332-5HB01-0AB0Siemens | SM 332 analog output, 2 AO, voltage/current, 12 bit | In stock | View | |
![]() | 6ES7332-7ND02-0AB0Siemens | SM 332 analog output, 4 AO, 16 bit, isolated per channel | In stock | View |
Product Questions
Is the 6ES7331-1KF02-0AB0 discontinued?
Yes. Its manufacturer lifecycle status is Discontinued.
Can another Siemens SIMATIC S7-300 part replace it?
Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.
Do you ship worldwide?
Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.
Related Products and Accessories
Siemens
6ES7352-1AH02-0AE0FM 352 electronic cam controller, 13 cam tracks
Same SIMATIC S7-300 system
In stock
Siemens
6ES7355-0VH10-0AE0FM 355 C controller module, 4 continuous control channels
Same SIMATIC S7-300 system
In stock
Siemens
6ES7307-1BA01-0AA0PS307 power supply, 120/230 V AC in, 24 V DC 2 A out
Same SIMATIC S7-300 system
In stock
Siemens
6ES7307-1KA02-0AA0PS307 power supply, 120/230 V AC in, 24 V DC 10 A out
Same SIMATIC S7-300 system
In stock
Latest news
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.