Image is for illustrative purposes only. Please refer to product description.
- Manufacturer
- Siemens
- Manufacturer part number
- 6ES7131-6BH01-0BA0
- Product family
- SIMATIC ET 200SP Distributed I/O
- Category
- PLCs and I/O › Digital I/O modules
- Technical datasheet
- Data sheet
Specifications
| Attribute | Value |
|---|---|
| Type | Digital input module |
| Manufacturer lifecycle | Active |
| Product type designation | DI 16x24VDC ST |
| HW functional status | From FS02 |
| Firmware version | V0.0 |
| Firmware version / FW update possible | No |
| usable BaseUnits | BU type A0 |
| Color code for module-specific color-coded label | CC00 |
| Product function / I&M data | Yes; I&M0 to I&M3 |
| Product function / Isochronous mode | No |
| Product function / suitable for operation on PROFINET R1 IMs | Yes |
| Engineering with / STEP 7 TIA Portal configurable/integrated from version | V14 |
| Engineering with / STEP 7 configurable/integrated from version | V5.5 SP3 |
| Engineering with / PCS 7 configurable/integrated from version | V8.1 SP1 |
| Engineering with / PCS neo can be configured/integrated from version | from V1.0.0 |
Show all 86 specificationsShow fewer specifications
| Engineering with / PROFIBUS from GSD version/GSD revision | One GSD file each, Revision 3 and 5 and higher |
|---|---|
| Engineering with / PROFINET from GSD version/GSD revision | GSDML V2.3 |
| Operating mode / DI | Yes |
| Operating mode / Counter | No |
| Operating mode / Oversampling | No |
| Operating mode / MSI | No |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Supply voltage / Reverse polarity protection | Yes |
| Input current / Current consumption, max. | 90 mA |
| 24 V encoder supply / 24 V | No |
| Power loss, typ. | 1.7 W |
| Address space per module / Inputs | 2 byte; + 2 bytes for QI information |
| Hardware configuration / Automatic encoding | Yes |
| Automatic encoding / Mechanical coding element | Yes |
| Automatic encoding / Type of mechanical coding element | Type A |
| Selection of BaseUnit for connection variants / 1-wire connection | BU type A0 |
| Selection of BaseUnit for connection variants / 2-wire connection | BU type A0 + Potential distributor module |
| Selection of BaseUnit for connection variants / 3-wire connection | BU type A0 + Potential distributor module |
| Selection of BaseUnit for connection variants / 4-wire connection | BU type A0 + Potential distributor module |
| Number of digital inputs | 16 |
| Digital inputs, parameterizable | Yes |
| Digital inputs / Sourcing/sinking input | P-reading |
| Digital inputs / Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
| Input voltage / Rated value (DC) | 24 V |
| Input voltage / for signal "0" | -30 to +5 V |
| Input voltage / for signal "1" | +11 to +30V |
| Input current / for signal "1", typ. | 2.5 mA |
| Input delay (for rated value of input voltage) / for standard inputs / parameterizable | Yes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms (in each case + delay of 30 to 500 µs, depending on line length) |
| Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", min. | 0.05 ms |
| Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", max. | 20 ms |
| Input delay (for rated value of input voltage) / for standard inputs / at "1" to "0", min. | 0.05 ms |
| Input delay (for rated value of input voltage) / for standard inputs / at "1" to "0", max. | 20 ms |
| Cable length / shielded, max. | 1 000 m |
| Cable length / unshielded, max. | 600 m |
| Connectable encoders / 2-wire sensor | Yes |
| Connectable encoders / 2-wire sensor / permissible quiescent current (2-wire sensor), max. | 1.5 mA |
| Interrupts/diagnostics/status information / Diagnostics function | Yes |
| Alarms / Diagnostic alarm | Yes |
| Diagnoses / Diagnostic information readable | Yes |
| Diagnoses / Monitoring the supply voltage | Yes |
| Diagnoses / Monitoring the supply voltage / parameterizable | Yes |
| Diagnoses / Monitoring of encoder power supply | No |
| Diagnoses / Wire break | Yes; Module-by-module, optional protective circuit for preventing wire-break diagnostics in the case of simple encoder contacts: 25 kOhm to 45 kOhm |
| Diagnoses / Short-circuit | No |
| Diagnoses / Group error | Yes |
| Diagnostics indication LED / Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED / Channel status display | Yes; green LED |
| Diagnostics indication LED / for channel diagnostics | No |
| Diagnostics indication LED / for module diagnostics | Yes; green/red DIAG LED |
| Potential separation channels / between the channels | No |
| Potential separation channels / between the channels and backplane bus | Yes |
| Potential separation channels / between the channels and the power supply of the electronics | No |
| Isolation tested with | 707 V DC (type test) |
| Standards, approvals, certificates / Suitable for safety functions | No |
| Ecological footprint / environmental product declaration | Yes |
| Ecological footprint / Global warming potential / global warming potential, (total) [CO2 eq] | 21 kg |
| Ecological footprint / Global warming potential / global warming potential, (during production) [CO2 eq] | 4.25 kg |
| Ecological footprint / Global warming potential / global warming potential, (during operation) [CO2 eq] | 17.5 kg |
| Ecological footprint / Global warming potential / global warming potential, (after end of life cycle) [CO2 eq] | -0.743 kg |
| Ambient temperature during operation / horizontal installation, min. | -30 °C; < 0 °C as of FS02 |
| Ambient temperature during operation / horizontal installation, max. | 60 °C |
| Ambient temperature during operation / vertical installation, min. | -30 °C; < 0 °C as of FS02 |
| Ambient temperature during operation / vertical installation, max. | 50 °C |
| Altitude during operation relating to sea level / Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Absolute humidity / dew point, min. | -60 °C; suitable for dry room applications |
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 28 g |
Description
The Siemens 6ES7131-6BH01-0BA0 is the ET 200SP DI 16x24VDC ST digital input module: 16 inputs at 24 V DC, IEC 61131 type 3, sink input (PNP). Siemens's data sheet gives an input delay adjustable from 0.05 to 20 ms and diagnostics for wire break and supply voltage; it fits BaseUnits of type A0. SiePortal lists it as an active product.
Application: Digital input module
Used with: ET 200SP BaseUnits of type A0
What is the 6ES7131-6BH01-0BA0 used for?
It reads switches and sensors into an ET 200SP station, 16 per module.
Key features
- 16 digital inputs, 24 V DC, IEC 61131 type 3
- Sink input (PNP)
- Input delay adjustable from 0.05 to 20 ms
- Diagnostics: wire break, supply voltage
- Fits BaseUnit type A0, colour code CC00
Documents and Resources
Associated Products
| Image | Product | Description | Stock | View | Add to RFQ |
|---|---|---|---|---|---|
![]() | 6ES7155-6AU01-0CN0Siemens | IM 155-6 PN/2 High Feature interface module | In stock | View | |
![]() | 6ES7193-6AR00-0AA0Siemens | BusAdapter BA 2xRJ45 | In stock | View | |
![]() | 6ES7193-6BP00-0DA0Siemens | BaseUnit BU15-P16+A0+2D, new load group | In stock | View | |
![]() | 6ES7193-6BP00-0BA0Siemens | BaseUnit BU15-P16+A0+2B, bridged to the left | In stock | View | |
![]() | 6ES7132-6BH01-0BA0Siemens | DQ 16x24VDC/0.5A ST digital output module | In stock | View |
Product Questions
Is the 6ES7131-6BH01-0BA0 discontinued?
No. Its manufacturer lifecycle status is Active.
Can another Siemens SIMATIC ET 200SP part replace it?
Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.
Do you ship worldwide?
Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.
Latest news
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.