Siemens SIMATIC S7-400 CPU 412-2 PN: central processing unit with 1 MB work memory (0.5 MB code, 0.5 MB data), an MPI/DP interface at 12 Mbit/s and an Ethernet/PROFINET interface.
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7412-2EK06-0AB0
- Product family
- SIMATIC S7-400 PLC CPUs
- Type
- PLC CPU
- Lifecycle
- Discontinued
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7412-2EK06-0AB0
- Type
- PLC CPU
- Application
- PLC controller
- Used with
- SIMATIC S7-400 rack (system power supply)
- Product type designation
- CPU 412-2 PN
- HW functional status
- 01
- Firmware version
- V6.0
- Product function / Isochronous mode
- Yes; Via PROFIBUS DP or PROFINET interface
- Engineering with / Programming package
- STEP 7 V5.5 or higher/iMap V3.0 + iMap STEP 7 Add-on V3.0 SP5 or higher
- CiR synchronization time, basic load
- 100 ms
- CiR synchronization time, time per I/O byte
- 30 µs; Time per I/O byte
- Supply voltage / Rated value (DC)
- Power supply via system power supply
- Input current / from backplane bus 5 V DC, typ.
- 1.1 A
- Input current / from backplane bus 5 V DC, max.
- 1.3 A
- Input current / from backplane bus 24 V DC, max.
- 150 mA; 150 mA per DP interface
- Input current / from interface 5 V DC, max.
- 90 mA; At the DP interface
- Power loss, typ.
- 5.5 W
- Storage / Type of memory
- RAM
- Work memory / Integrated
- 1 Mbyte
- Work memory / integrated (for program)
- 0.5 Mbyte
- Work memory / integrated (for data)
- 0.5 Mbyte
- Work memory / expandable
- No
- Load memory / expandable FEPROM
- Yes; with Memory Card (FLASH)
- Load memory / expandable FEPROM, max.
- 64 Mbyte
- Load memory / integrated RAM, max.
- 512 kbyte
- Load memory / expandable RAM
- Yes; with Memory Card (RAM)
- Load memory / expandable RAM, max.
- 64 Mbyte
- Backup / present
- Yes
- Backup / with battery
- Yes; all data
Show all 398 specificationsShow fewer
- Backup / Without battery
- No
- Backup battery / Backup current, typ.
- 125 µA; up to 40 °C
- Backup battery / Backup current, max.
- 450 µA
- Backup battery / Backup time, max.
- Dealt with in the module data manual with the secondary conditions and the factors of influence
- Backup battery / Feeding of external backup voltage to CPU
- 5 V DC to 15 V DC
- CPU processing times / for bit operations, typ.
- 75 ns
- CPU processing times / for word operations, typ.
- 75 ns
- CPU processing times / for fixed point arithmetic, typ.
- 75 ns
- CPU processing times / for floating point arithmetic, typ.
- 225 ns
- DB / Number, max.
- 3 000; Number range: 1 to 16000
- DB / Size, max.
- 64 kbyte
- FB / Number, max.
- 1 500; Number range: 0 to 7999
- FB / Size, max.
- 64 kbyte
- FC / Number, max.
- 1 500; Number range: 0 to 7999
- FC / Size, max.
- 64 kbyte
- OB / Number, max.
- see instruction list
- OB / Size, max.
- 64 kbyte
- OB / Number of free cycle OBs
- 1; OB 1
- OB / Number of time alarm OBs
- 2; OB 10, 11
- OB / Number of delay alarm OBs
- 2; OB 20, 21
- OB / Number of cyclic interrupt OBs
- 2; OB 32, 35 (shortest cycle that can be set = 500 µs)
- OB / Number of process alarm OBs
- 2; OB 40, 41
- OB / Number of DPV1 alarm OBs
- 3; OB 55-57
- OB / Number of isochronous mode OBs
- 2; OB 61-62
- OB / Number of multicomputing OBs
- 1; OB 60
- OB / Number of background OBs
- 1; OB 90
- OB / Number of startup OBs
- 3; OB 100-102
- OB / Number of asynchronous error OBs
- 9; OB 80-88
- OB / Number of synchronous error OBs
- 2; OB 121, 122
- Nesting depth / per priority class
- 24
- Nesting depth / additional within an error OB
- 1
- S7 counter / Number
- 2 048
- S7 counter / Retentivity / can be set
- Yes
- S7 counter / Retentivity / preset
- Z 0 to Z 7
- S7 counter / Counting range / lower limit
- 0
- S7 counter / Counting range / upper limit
- 999
- IEC counter / present
- Yes
- IEC counter / Type
- SFB
- IEC counter / Number
- Unlimited (limited only by RAM capacity)
- S7 timer / Number
- 2 048
- S7 timer / Retentivity / can be set
- Yes
- S7 timer / Retentivity / preset
- No times retentive
- S7 timer / Time range / lower limit
- 10 ms
- S7 timer / Time range / upper limit
- 9 990 s
- IEC timer / present
- Yes
- IEC timer / Type
- SFB
- IEC timer / Number
- Unlimited (limited only by RAM capacity)
- Retentive data area (incl. timers, counters, flags), max.
- Total working and load memory (with backup battery)
- Flag / Size, max.
- 4 kbyte; Size of bit memory address area
- Flag / Retentivity available
- Yes
- Flag / Retentivity preset
- MB 0 to MB 15
- Flag / Number of clock memories
- 8; in 1 memory byte
- Local data / adjustable, max.
- 8 kbyte
- Local data / preset
- 4 kbyte
- I/O address area / Inputs
- 4 kbyte
- I/O address area / Outputs
- 4 kbyte
- Process image / Inputs, adjustable
- 4 kbyte
- Process image / Outputs, adjustable
- 4 kbyte
- Process image / Inputs, default
- 128 kbyte
- Process image / Outputs, default
- 128 kbyte
- Process image / consistent data, max.
- 244 byte
- Process image / Access to consistent data in process image
- Yes
- Subprocess images / Number of subprocess images, max.
- 15
- Digital channels / Inputs
- 32 768
- Digital channels / Inputs / of which central
- 32 768
- Digital channels / Outputs
- 32 768
- Digital channels / Outputs / of which central
- 32 768
- Analog channels / Inputs
- 2 048
- Analog channels / Inputs / of which central
- 2 048
- Analog channels / Outputs
- 2 048
- Analog channels / Outputs / of which central
- 2 048
- Hardware configuration / Integrated power supply
- No
- Hardware configuration / Number of expansion units, max.
- 21
- Hardware configuration / connectable OPs
- 47
- Hardware configuration / Multicomputing
- Yes; 4 CPUs max. (with UR1 or UR2)
- Interface modules / Number of connectable IMs (total), max.
- 6
- Interface modules / Number of connectable IM 460s, max.
- 6
- Interface modules / Number of connectable IM 463s, max.
- 4; IM 463-2
- Number of DP masters / integrated
- 1
- Number of DP masters / via CP
- 10; CP 443-5 Extended
- Number of DP masters / via IM 467
- 4
- Number of DP masters / Mixed mode IM + CP permitted
- No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
- Number of DP masters / via interface module
- 0
- Number of DP masters / Number of pluggable S5 modules (via adapter capsule in central device), max.
- 6
- Number of IO Controllers / Integrated
- 1
- Number of IO Controllers / Via CP
- 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
- Number of operable FMs and CPs (recommended) / FM
- Limited by number of slots and number of connections
- Number of operable FMs and CPs (recommended) / CP, PtP
- CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections
- Number of operable FMs and CPs (recommended) / PROFIBUS and Ethernet CPs
- 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
- Slots / required slots
- 1
- Clock / Hardware clock (real-time)
- Yes
- Clock / retentive and synchronizable
- Yes
- Clock / Resolution
- 1 ms
- Clock / Deviation per day (buffered), max.
- 1.7 s; Power off
- Clock / Deviation per day (unbuffered), max.
- 8.6 s; For power On
- Operating hours counter / Number
- 16
- Operating hours counter / Number/Number range
- 0 to 15
- Operating hours counter / Range of values
- SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
- Operating hours counter / Granularity
- 1 h
- Operating hours counter / retentive
- Yes
- Clock synchronization / supported
- Yes
- Clock synchronization / to MPI, master
- Yes
- Clock synchronization / on MPI, device
- Yes
- Clock synchronization / to DP, master
- Yes
- Clock synchronization / on DP, device
- Yes
- Clock synchronization / in AS, master
- Yes
- Clock synchronization / in AS, device
- Yes
- Clock synchronization / on Ethernet via NTP
- Yes; As client
- Time difference in system when synchronizing via / Ethernet, max.
- 10 ms
- Time difference in system when synchronizing via / MPI, max.
- 200 ms
- Interfaces/bus type
- 1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports)
- Number of RS 485 interfaces
- 1
- Number of other interfaces
- 0
- Interfaces / Optical interface
- No
- 1. Interface / Interface type
- MPI/PROFIBUS DP
- 1. Interface / Isolated
- Yes
- Interface types / RS 485
- Yes
- Interface types / Output current of the interface, max.
- 150 mA
- Protocols / MPI
- Yes
- 1. Interface / Protocols / PROFIBUS DP master
- Yes
- 1. Interface / Protocols / PROFIBUS DP device
- Yes
- MPI / Number of connections
- 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
- MPI / Transmission rate, max.
- 12 Mbit/s
- MPI / Services / PG/OP communication
- Yes
- MPI / Services / Routing
- Yes
- MPI / Services / Global data communication
- Yes
- MPI / Services / S7 basic communication
- Yes
- MPI / Services / S7 communication
- Yes
- MPI / Services / S7 communication, as client
- Yes
- MPI / Services / S7 communication, as server
- Yes
- PROFIBUS DP master / Number of connections, max.
- 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
- PROFIBUS DP master / Transmission rate, max.
- 12 Mbit/s
- PROFIBUS DP master / max. number of DP devices
- 32
- PROFIBUS DP master / Services / PG/OP communication
- Yes
- PROFIBUS DP master / Services / Routing
- Yes
- PROFIBUS DP master / Services / Global data communication
- No
- PROFIBUS DP master / Services / S7 basic communication
- Yes
- PROFIBUS DP master / Services / S7 communication
- Yes
- PROFIBUS DP master / Services / S7 communication, as client
- Yes
- PROFIBUS DP master / Services / S7 communication, as server
- Yes
- PROFIBUS DP master / Services / Equidistance
- Yes
- PROFIBUS DP master / Services / Isochronous mode
- Yes
- PROFIBUS DP master / Services / SYNC/FREEZE
- Yes
- PROFIBUS DP master / Services / activation/deactivation of DP devices
- Yes
- PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)
- Yes
- PROFIBUS DP master / Services / DPV1
- Yes
- PROFIBUS DP master / Address area / Inputs, max.
- 2 kbyte
- PROFIBUS DP master / Address area / Outputs, max.
- 2 kbyte
- PROFIBUS DP master / User data per DP device / user data per DP device, max.
- 244 byte
- PROFIBUS DP master / User data per DP device / Inputs, max.
- 244 byte
- PROFIBUS DP master / User data per DP device / Outputs, max.
- 244 byte
- PROFIBUS DP master / User data per DP device / Slots, max.
- 244
- PROFIBUS DP master / User data per DP device / per slot, max.
- 128 byte
- PROFIBUS DP device / Number of connections
- 16
- PROFIBUS DP device / Transmission rate, max.
- 12 Mbit/s
- PROFIBUS DP device / automatic baud rate search
- No
- PROFIBUS DP device / Address area, max.
- 32; Virtual slots
- PROFIBUS DP device / User data per address area, max.
- 32 byte
- PROFIBUS DP device / User data per address area, max. / of which consistent, max.
- 32 byte
- PROFIBUS DP device / Services / PG/OP communication
- Yes; with interface active
- PROFIBUS DP device / Services / Routing
- Yes; with interface active
- PROFIBUS DP device / Services / Global data communication
- No
- PROFIBUS DP device / Services / S7 basic communication
- No
- PROFIBUS DP device / Services / S7 communication
- Yes
- PROFIBUS DP device / Services / S7 communication, as client
- Yes
- PROFIBUS DP device / Services / S7 communication, as server
- Yes
- PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)
- No
- PROFIBUS DP device / Services / DPV1
- No
- PROFIBUS DP device / Transfer memory / Inputs
- 244 byte
- PROFIBUS DP device / Transfer memory / Outputs
- 244 byte
- 2. Interface / Interface type
- PROFINET
- 2. Interface / Isolated
- Yes
- 2. Interface / automatic detection of transmission rate
- Yes; Autosensing
- 2. Interface / Autonegotiation
- Yes
- 2. Interface / Autocrossing
- Yes
- 2. Interface / Change of IP address at runtime, supported
- Yes; Assignment by higher-level IO-Controller or by the user program with SFB104 "IP_CONF"
- Interface types / RJ 45 (Ethernet)
- Yes
- Interface types / Number of ports
- 2
- Interface types / integrated switch
- Yes
- Protocols / PROFINET IO Controller
- Yes
- Protocols / PROFINET IO device
- Yes
- Protocols / PROFINET CBA
- Yes
- 2. Interface / Protocols / PROFIBUS DP master
- No
- 2. Interface / Protocols / PROFIBUS DP device
- No
- Protocols / Open IE communication
- Yes
- Protocols / Web server
- Yes
- Protocols / Point-to-point connection
- No
- Protocols / Media redundancy
- Yes
- PROFINET IO Controller / Transmission rate, max.
- 100 Mbit/s
- PROFINET IO Controller / Services / PG/OP communication
- Yes
- PROFINET IO Controller / Services / S7 communication
- Yes
- PROFINET IO Controller / Services / Isochronous mode
- Yes; Only with IRT and the High Performance option
- PROFINET IO Controller / Services / Shared device
- Yes
- PROFINET IO Controller / Services / Prioritized startup
- Yes
- PROFINET IO Controller / Services / Number of IO devices with prioritized startup, max.
- 32
- PROFINET IO Controller / Services / Number of connectable IO Devices, max.
- 256
- PROFINET IO Controller / Services / Of which IO devices with IRT, max.
- 64
- 2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. / Of which IO devices with IRT, max. / of which in line, max.
- 64
- PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility"
- 256
- 2. Interface / PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility" / of which in line, max.
- 61
- PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max.
- 256
- 2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max.
- 256
- PROFINET IO Controller / Services / Activation/deactivation of IO Devices
- Yes
- PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max.
- 8
- PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supported
- Yes
- PROFINET IO Controller / Services / Number of IO Devices per tool, max.
- 8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation (partner ports) are supported
- PROFINET IO Controller / Services / Device replacement without swap medium
- Yes
- PROFINET IO Controller / Services / Send cycles
- 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame
- PROFINET IO Controller / Services / Updating time
- 250 µs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description
- PROFINET IO Controller / Address area / Inputs, max.
- 4 kbyte
- PROFINET IO Controller / Address area / Outputs, max.
- 4 kbyte
- PROFINET IO Controller / Address area / User data consistency, max.
- 1 024 byte
- PROFINET IO Device / Services / PG/OP communication
- Yes
- PROFINET IO Device / Services / S7 communication
- Yes
- PROFINET IO Device / Services / Isochronous mode
- No
- PROFINET IO Device / Services / IRT
- Yes
- PROFINET IO Device / Services / Prioritized startup
- Yes
- PROFINET IO Device / Services / Shared device
- Yes
- PROFINET IO Device / Services / Number of IO Controllers with shared device, max.
- 2
- PROFINET IO Device / Transfer memory / Inputs, max.
- 1 440 byte; Per IO Controller with shared device
- PROFINET IO Device / Transfer memory / Outputs, max.
- 1 440 byte; Per IO Controller with shared device
- PROFINET IO Device / Submodules / Number, max.
- 64
- PROFINET IO Device / Submodules / User data per submodule, max.
- 1 024 byte
- PROFINET IO Device / PROFINET CBA / acyclic transmission
- Yes
- PROFINET IO Device / PROFINET CBA / cyclic transmission
- Yes
- PROFINET IO Device / Open IE communication / Number of connections, max.
- 46
- PROFINET IO Device / Open IE communication / Local port numbers used at the system end
- 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
- PROFINET IO Device / Open IE communication / Keep-alive function, supported
- Yes
- Redundancy mode / Media redundancy / Switchover time on line break, typ.
- 200 ms
- Redundancy mode / Media redundancy / Number of stations in the ring, max.
- 50
- SIMATIC communication / S7 routing
- Yes
- Open IE communication / TCP/IP
- Yes; via integrated PROFINET interface and loadable FBs
- Open IE communication / TCP/IP / Number of connections, max.
- 46
- Open IE communication / TCP/IP / Data length, max.
- 32 kbyte
- Open IE communication / TCP/IP / several passive connections per port, supported
- Yes
- Open IE communication / ISO-on-TCP (RFC1006)
- Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs
- Open IE communication / ISO-on-TCP (RFC1006) / Number of connections, max.
- 46
- Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.
- 32 kbyte; 1 452 bytes via CP 443-1 Adv.
- Open IE communication / UDP
- Yes; via integrated PROFINET interface and loadable FBs
- Open IE communication / UDP / Number of connections, max.
- 46
- Open IE communication / UDP / Data length, max.
- 1 472 byte
- Web server / supported
- Yes
- Web server / User-defined websites
- Yes
- Web server / Number of HTTP clients
- 5
- Isochronous mode / Equidistance
- Yes
- Number of DP masters with isochronous mode
- 1
- payload per isochronous device, max.
- 244 byte
- Isochronous mode / shortest clock pulse
- 1.5 ms; 0.5 ms without use of SFC 126, 127
- Isochronous mode / max. cycle
- 32 ms
- PG/OP communication
- Yes
- PG/OP communication / Number of connectable OPs with message processing
- 47; When using Alarm_S/SQ and Alarm_D/DQ
- PG/OP communication / Number of connectable OPs without message processing
- 47
- Communication functions / Data record routing
- Yes
- Global data communication / supported
- Yes
- Global data communication / Number of GD loops, max.
- 8
- Global data communication / Number of GD packets, transmitter, max.
- 8
- Global data communication / Number of GD packets, receiver, max.
- 16
- Global data communication / Size of GD packets, max.
- 54 byte
- Global data communication / Size of GD packet (of which consistent), max.
- 1 variable
- S7 basic communication / supported
- Yes
- S7 basic communication / User data per job, max.
- 76 byte
- S7 basic communication / User data per job (of which consistent), max.
- 1 variable
- S7 communication / supported
- Yes
- S7 communication / as server
- Yes
- S7 communication / As client
- Yes
- S7 communication / User data per job, max.
- 64 kbyte
- S7 communication / User data per job (of which consistent), max.
- 462 byte; 1 variable
- S5 compatible communication / supported
- Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
- S5 compatible communication / User data per job, max.
- 8 kbyte
- S5 compatible communication / User data per job (of which consistent), max.
- 240 byte
- S5 compatible communication / Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.
- 24/24
- Standard communication (FMS) / supported
- Yes; Via CP and loadable FB
- PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load
- 20 %
- PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners
- 32
- PROFINET CBA (at set setpoint communication load) / number of master/device functions
- 150
- PROFINET CBA (at set setpoint communication load) / total of all master/device connections
- 4 500
- PROFINET CBA (at set setpoint communication load) / data length of all incoming master/device connections, max.
- 45 000 byte
- PROFINET CBA (at set setpoint communication load) / data length of all outgoing master/device connections, max.
- 45 000 byte
- PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnections
- 1 000
- PROFINET CBA (at set setpoint communication load) / Data length of device-internal und PROFIBUS interconnections, max.
- 16 000 byte
- PROFINET CBA (at set setpoint communication load) / Data length per connection, max.
- 2 000 byte
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: Transmission interval, min.
- 1 ms; Depending on preset communication load, number of interconnections and data length used
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections
- 300
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections
- 300
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all incoming interconnections, max.
- 4 800 byte
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all outgoing interconnections, max.
- 4 800 byte
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length per connection, max.
- 450 byte
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of stations that can log on for HMI variables (PN OPC/iMap)
- 2x PN OPC/1x iMap
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating
- 500 ms
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables
- 1 000
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max.
- 32 000 byte
- PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supported
- Yes; 32 PROFIBUS slaves max. connectable
- PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max.
- 240 byte; Slave-dependent
- Number of connections / overall
- 48
- Number of connections / usable for PG communication / reserved for PG communication
- 1
- Number of connections / usable for PG communication / adjustable for PG communication, max.
- 0
- Number of connections / usable for OP communication / reserved for OP communication
- 1
- Number of connections / usable for OP communication / adjustable for OP communication, max.
- 0
- Number of connections / usable for S7 basic communication / reserved for S7 basic communication
- 0
- Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.
- 0
- Number of connections / usable for S7 communication / reserved for S7 communication
- 0
- Number of connections / usable for S7 communication / adjustable for S7 communication, max.
- 0
- Number of connections / usable for routing / reserved for routing
- 0
- Number of connections / usable for routing / adjustable for routing, max.
- 0
- S7 message functions / Number of login stations for message functions, max.
- 47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
- S7 message functions / Symbol-related messages
- Yes
- S7 message functions / SCAN procedure
- Yes
- S7 message functions / Program alarms
- Yes
- S7 message functions / Process diagnostic messages
- Yes
- S7 message functions / simultaneously active Alarm_S blocks, max.
- 250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
- S7 message functions / Alarm 8-blocks
- Yes
- Alarm 8-blocks / Number of instances for alarm 8 and S7 communication blocks, max.
- 300
- Alarm 8-blocks / preset, max.
- 150
- S7 message functions / Process control messages
- Yes
- S7 message functions / Number of archives that can log on simultaneously (SFB 37 AR_SEND)
- 4
- Number of messages / overall, max.
- 256
- Number of messages / in 100 ms grid, max.
- 0
- Number of messages / in 500 ms grid, max.
- 256
- Number of messages / in 1000 ms grid, max.
- 256
- Number of additional values / with 100 ms grid, max.
- 0
- Number of additional values / with 500, 1000 ms grid, max.
- 1
- Test commissioning functions / Status block
- Yes; Up to 16 simultaneously
- Test commissioning functions / Single step
- Yes
- Test commissioning functions / Number of breakpoints
- 16
- Status/control / Status/control variable
- Yes; Up to 16 variable tables
- Status/control / Variables
- Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
- Status/control / Number of variables, max.
- 70; Status/control
- Forcing / Forcing
- Yes
- Forcing / Forcing, variables
- Inputs/outputs, bit memories, distributed I/Os
- Forcing / Number of variables, max.
- 64
- Diagnostic buffer / present
- Yes
- Diagnostic buffer / Number of entries, max.
- 400
- Diagnostic buffer / Number of entries, max. / can be set
- Yes
- Diagnostic buffer / Number of entries, max. / preset
- 120
- Service data / Can be read out
- Yes
- Emission of radio interference acc. to EN 55 011 / Limit class A, for use in industrial areas
- Yes
- Emission of radio interference acc. to EN 55 011 / Limit class B, for use in residential areas
- No
- Configuration software / STEP 7
- Yes
- Programming / Command set
- see instruction list
- Programming / Nesting levels
- 7
- Programming / Access to consistent data in process image
- Yes
- Programming / System functions (SFC)
- see instruction list
- Programming / System function blocks (SFB)
- see instruction list
- Programming / Programming language / LAD
- Yes
- Programming / Programming language / FBD
- Yes
- Programming / Programming language / STL
- Yes
- Programming / Programming language / SCL
- Yes
- Programming / Programming language / CFC
- Yes
- Programming / Programming language / GRAPH
- Yes
- Programming / Programming language / HiGraph®
- Yes
- Programming / Number of simultaneously active SFCs / DPSYC_FR
- 2
- Programming / Number of simultaneously active SFCs / D_ACT_DP
- 8
- Programming / Number of simultaneously active SFCs / RD_REC
- 8
- Programming / Number of simultaneously active SFCs / WR_REC
- 8
- Programming / Number of simultaneously active SFCs / WR_PARM
- 8
- Programming / Number of simultaneously active SFCs / PARM_MOD
- 1
- Programming / Number of simultaneously active SFCs / WR_DPARM
- 2
- Programming / Number of simultaneously active SFCs / DPNRM_DG
- 8
- Programming / Number of simultaneously active SFCs / RDSYSST
- 8
- Programming / Number of simultaneously active SFCs / DP_TOPOL
- 1
- Programming / Number of simultaneously active SFBs / RDREC
- 8
- Programming / Number of simultaneously active SFBs / WRREC
- 8
- Know-how protection / User program protection/password protection
- Yes
- Know-how protection / Block encryption
- Yes; With S7 block Privacy
- Width
- 25 mm
- Height
- 290 mm
- Depth
- 219 mm
- Weight, approx.
- 750 g
Technical documents (1)
Key features
- 1 MB work memory: 0.5 MB code, 0.5 MB data
- 1st interface MPI/PROFIBUS DP 12 Mbit/s (X1)
- 2nd interface Ethernet/PROFINET (X5), media redundancy
- Isochronous mode via PROFIBUS DP or PROFINET
- Powered from the S7-400 system power supply
About the Siemens 6ES7412-2EK06-0AB0
The Siemens 6ES7412-2EK06-0AB0 is the CPU 412-2 PN, the entry CPU of the S7-400 with PROFINET. Siemens's data sheet gives it 1 MB of work memory, split into 0.5 MB for code and 0.5 MB for data, a combined MPI/PROFIBUS DP interface at 12 Mbit/s and an Ethernet/PROFINET interface. It is powered from the S7-400 rack's system power supply.
What is the 6ES7412-2EK06-0AB0 used for?
It runs S7-400 stations that need PROFINET but not a large program, such as smaller lines and plant sections, with I/O in the rack and on PROFIBUS DP or PROFINET.
Lifecycle and successor
Discontinued.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the full order number and the firmware version on the CPU's front label; send a photo of it. S7-400 CPUs of the same type differ by order number in memory and interfaces, so quote against the exact number, and list any interface modules (IF) fitted.
Alternatives for 6ES7412-2EK06-0AB0
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| Siemens 6ES7412-3HJ14-0AB0CPU 412-3H for S7-400H/F/FH, 768 KB, MPI/DP and 2 sync interfaces | Siemens | Redundant PLC CPU (H-CPU) | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7414-2XK05-0AB0CPU 414-2, 1 MB, MPI/DP and PROFIBUS DP | Siemens | PLC CPU | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7414-3XM07-0AB0CPU 414-3, 4 MB, MPI/DP, PROFIBUS DP and IF slot | Siemens | PLC CPU | Active | Same family | On Request | On request | View › |
| Siemens 6ES7416-2XP07-0AB0CPU 416-2, 8 MB, MPI/DP and PROFIBUS DP | Siemens | PLC CPU | Active | Same family | On Request | On request | View › |
| Siemens 6ES7416-3XS07-0AB0CPU 416-3, 16 MB, MPI/DP, PROFIBUS DP and IF slot | Siemens | PLC CPU | Active | Same family | On Request | On request | View › |
| Siemens 6ES7417-4XT05-0AB0CPU 417-4, 30 MB, MPI, PROFIBUS DP and 2 IF slots | Siemens | PLC CPU | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7414-4HM14-0AB0CPU 414-4H for S7-400H/F/FH, 2.8 MB, MPI/DP, DP and 2 sync interfaces | Siemens | Redundant PLC CPU (H-CPU) | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7416-3FS07-0AB0CPU 416F-3 PN/DP fail-safe, 16 MB, MPI/DP, PROFINET and IF slot | Siemens | Safety PLC CPU (F-CPU) | Active | Same family | On Request | On request | View › |
You may also be interested in

Siemens
Siemens 6ES7972-0BA12-0XA0
View ›
Siemens
Siemens 6ES7972-0BB12-0XA0
View ›
Siemens
Siemens 6ES7972-0BA42-0XA0
View ›
Siemens
Siemens 6ES7972-0BB42-0XA0
View ›
Siemens
Siemens 6ES7972-0BA52-0XA0
View ›
Siemens
Siemens 6ES7972-0BB52-0XA0
View ›
Siemens
Siemens 6ES7972-0BA61-0XA0
View ›
Siemens
Siemens 6ES7972-0BA70-0XA0
View ›
Siemens
Siemens 6GK1500-0FC10
View ›
Siemens
Siemens 6GK1901-1BB10-2AA0
View ›
Siemens
Siemens 6GK1901-1BB11-2AA0
View ›
Siemens
Siemens 6XV1830-0EH10
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.