Siemens 6ES7412-2EK06-0AB0

CPU 412-2 PN, 1 MB, MPI/DP and PROFINET

Request a quote
Siemens
Siemens 6ES7412-2EK06-0AB0 CPU 412-2 PN, photo from Siemens data sheet 6ES7412-2EK06-0AB0

Image is for illustrative purposes only. Please refer to product description.

  • FedEx
  • DHL
  • UPS
Manufacturer
Siemens
Manufacturer part number
6ES7412-2EK06-0AB0
Technical datasheet
Data sheet

Specifications

AttributeValue
TypePLC CPU
Manufacturer lifecycleDiscontinued
Product type designationCPU 412-2 PN
HW functional status01
Firmware versionV6.0
Product function / Isochronous modeYes; Via PROFIBUS DP or PROFINET interface
Engineering with / Programming packageSTEP 7 V5.5 or higher/iMap V3.0 + iMap STEP 7 Add-on V3.0 SP5 or higher
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O byte30 µs; Time per I/O byte
Supply voltage / Rated value (DC)Power supply via system power supply
Input current / from backplane bus 5 V DC, typ.1.1 A
Input current / from backplane bus 5 V DC, max.1.3 A
Input current / from backplane bus 24 V DC, max.150 mA; 150 mA per DP interface
Input current / from interface 5 V DC, max.90 mA; At the DP interface
Power loss, typ.5.5 W
Show all 395 specifications
Storage / Type of memoryRAM
Work memory / Integrated1 Mbyte
Work memory / integrated (for program)0.5 Mbyte
Work memory / integrated (for data)0.5 Mbyte
Work memory / expandableNo
Load memory / expandable FEPROMYes; with Memory Card (FLASH)
Load memory / expandable FEPROM, max.64 Mbyte
Load memory / integrated RAM, max.512 kbyte
Load memory / expandable RAMYes; with Memory Card (RAM)
Load memory / expandable RAM, max.64 Mbyte
Backup / presentYes
Backup / with batteryYes; all data
Backup / Without batteryNo
Backup battery / Backup current, typ.125 µA; up to 40 °C
Backup battery / Backup current, max.450 µA
Backup battery / Backup time, max.Dealt with in the module data manual with the secondary conditions and the factors of influence
Backup battery / Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times / for bit operations, typ.75 ns
CPU processing times / for word operations, typ.75 ns
CPU processing times / for fixed point arithmetic, typ.75 ns
CPU processing times / for floating point arithmetic, typ.225 ns
DB / Number, max.3 000; Number range: 1 to 16000
DB / Size, max.64 kbyte
FB / Number, max.1 500; Number range: 0 to 7999
FB / Size, max.64 kbyte
FC / Number, max.1 500; Number range: 0 to 7999
FC / Size, max.64 kbyte
OB / Number, max.see instruction list
OB / Size, max.64 kbyte
OB / Number of free cycle OBs1; OB 1
OB / Number of time alarm OBs2; OB 10, 11
OB / Number of delay alarm OBs2; OB 20, 21
OB / Number of cyclic interrupt OBs2; OB 32, 35 (shortest cycle that can be set = 500 µs)
OB / Number of process alarm OBs2; OB 40, 41
OB / Number of DPV1 alarm OBs3; OB 55-57
OB / Number of isochronous mode OBs2; OB 61-62
OB / Number of multicomputing OBs1; OB 60
OB / Number of background OBs1; OB 90
OB / Number of startup OBs3; OB 100-102
OB / Number of asynchronous error OBs9; OB 80-88
OB / Number of synchronous error OBs2; OB 121, 122
Nesting depth / per priority class24
Nesting depth / additional within an error OB1
S7 counter / Number2 048
S7 counter / Retentivity / can be setYes
S7 counter / Retentivity / presetZ 0 to Z 7
S7 counter / Counting range / lower limit0
S7 counter / Counting range / upper limit999
IEC counter / presentYes
IEC counter / TypeSFB
IEC counter / NumberUnlimited (limited only by RAM capacity)
S7 timer / Number2 048
S7 timer / Retentivity / can be setYes
S7 timer / Retentivity / presetNo times retentive
S7 timer / Time range / lower limit10 ms
S7 timer / Time range / upper limit9 990 s
IEC timer / presentYes
IEC timer / TypeSFB
IEC timer / NumberUnlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.Total working and load memory (with backup battery)
Flag / Size, max.4 kbyte; Size of bit memory address area
Flag / Retentivity availableYes
Flag / Retentivity presetMB 0 to MB 15
Flag / Number of clock memories8; in 1 memory byte
Local data / adjustable, max.8 kbyte
Local data / preset4 kbyte
I/O address area / Inputs4 kbyte
I/O address area / Outputs4 kbyte
Process image / Inputs, adjustable4 kbyte
Process image / Outputs, adjustable4 kbyte
Process image / Inputs, default128 kbyte
Process image / Outputs, default128 kbyte
Process image / consistent data, max.244 byte
Process image / Access to consistent data in process imageYes
Subprocess images / Number of subprocess images, max.15
Digital channels / Inputs32 768
Digital channels / Inputs / of which central32 768
Digital channels / Outputs32 768
Digital channels / Outputs / of which central32 768
Analog channels / Inputs2 048
Analog channels / Inputs / of which central2 048
Analog channels / Outputs2 048
Analog channels / Outputs / of which central2 048
Hardware configuration / Integrated power supplyNo
Hardware configuration / Number of expansion units, max.21
Hardware configuration / connectable OPs47
Hardware configuration / MulticomputingYes; 4 CPUs max. (with UR1 or UR2)
Interface modules / Number of connectable IMs (total), max.6
Interface modules / Number of connectable IM 460s, max.6
Interface modules / Number of connectable IM 463s, max.4; IM 463-2
Number of DP masters / integrated1
Number of DP masters / via CP10; CP 443-5 Extended
Number of DP masters / via IM 4674
Number of DP masters / Mixed mode IM + CP permittedNo; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
Number of DP masters / via interface module0
Number of DP masters / Number of pluggable S5 modules (via adapter capsule in central device), max.6
Number of IO Controllers / Integrated1
Number of IO Controllers / Via CP4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended) / FMLimited by number of slots and number of connections
Number of operable FMs and CPs (recommended) / CP, PtPCP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections
Number of operable FMs and CPs (recommended) / PROFIBUS and Ethernet CPs14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
Slots / required slots1
Clock / Hardware clock (real-time)Yes
Clock / retentive and synchronizableYes
Clock / Resolution1 ms
Clock / Deviation per day (buffered), max.1.7 s; Power off
Clock / Deviation per day (unbuffered), max.8.6 s; For power On
Operating hours counter / Number16
Operating hours counter / Number/Number range0 to 15
Operating hours counter / Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Operating hours counter / Granularity1 h
Operating hours counter / retentiveYes
Clock synchronization / supportedYes
Clock synchronization / to MPI, masterYes
Clock synchronization / on MPI, deviceYes
Clock synchronization / to DP, masterYes
Clock synchronization / on DP, deviceYes
Clock synchronization / in AS, masterYes
Clock synchronization / in AS, deviceYes
Clock synchronization / on Ethernet via NTPYes; As client
Time difference in system when synchronizing via / Ethernet, max.10 ms
Time difference in system when synchronizing via / MPI, max.200 ms
Interfaces/bus type1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports)
Number of RS 485 interfaces1
Number of other interfaces0
Interfaces / Optical interfaceNo
1. Interface / Interface typeMPI/PROFIBUS DP
1. Interface / IsolatedYes
Interface types / RS 485Yes
Interface types / Output current of the interface, max.150 mA
Protocols / MPIYes
1. Interface / Protocols / PROFIBUS DP masterYes
1. Interface / Protocols / PROFIBUS DP deviceYes
MPI / Number of connections32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
MPI / Transmission rate, max.12 Mbit/s
MPI / Services / PG/OP communicationYes
MPI / Services / RoutingYes
MPI / Services / Global data communicationYes
MPI / Services / S7 basic communicationYes
MPI / Services / S7 communicationYes
MPI / Services / S7 communication, as clientYes
MPI / Services / S7 communication, as serverYes
PROFIBUS DP master / Number of connections, max.16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
PROFIBUS DP master / Transmission rate, max.12 Mbit/s
PROFIBUS DP master / max. number of DP devices32
PROFIBUS DP master / Services / PG/OP communicationYes
PROFIBUS DP master / Services / RoutingYes
PROFIBUS DP master / Services / Global data communicationNo
PROFIBUS DP master / Services / S7 basic communicationYes
PROFIBUS DP master / Services / S7 communicationYes
PROFIBUS DP master / Services / S7 communication, as clientYes
PROFIBUS DP master / Services / S7 communication, as serverYes
PROFIBUS DP master / Services / EquidistanceYes
PROFIBUS DP master / Services / Isochronous modeYes
PROFIBUS DP master / Services / SYNC/FREEZEYes
PROFIBUS DP master / Services / activation/deactivation of DP devicesYes
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)Yes
PROFIBUS DP master / Services / DPV1Yes
PROFIBUS DP master / Address area / Inputs, max.2 kbyte
PROFIBUS DP master / Address area / Outputs, max.2 kbyte
PROFIBUS DP master / User data per DP device / user data per DP device, max.244 byte
PROFIBUS DP master / User data per DP device / Inputs, max.244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.244 byte
PROFIBUS DP master / User data per DP device / Slots, max.244
PROFIBUS DP master / User data per DP device / per slot, max.128 byte
PROFIBUS DP device / Number of connections16
PROFIBUS DP device / Transmission rate, max.12 Mbit/s
PROFIBUS DP device / automatic baud rate searchNo
PROFIBUS DP device / Address area, max.32; Virtual slots
PROFIBUS DP device / User data per address area, max.32 byte
PROFIBUS DP device / User data per address area, max. / of which consistent, max.32 byte
PROFIBUS DP device / Services / PG/OP communicationYes; with interface active
PROFIBUS DP device / Services / RoutingYes; with interface active
PROFIBUS DP device / Services / Global data communicationNo
PROFIBUS DP device / Services / S7 basic communicationNo
PROFIBUS DP device / Services / S7 communicationYes
PROFIBUS DP device / Services / S7 communication, as clientYes
PROFIBUS DP device / Services / S7 communication, as serverYes
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)No
PROFIBUS DP device / Services / DPV1No
PROFIBUS DP device / Transfer memory / Inputs244 byte
PROFIBUS DP device / Transfer memory / Outputs244 byte
2. Interface / Interface typePROFINET
2. Interface / IsolatedYes
2. Interface / automatic detection of transmission rateYes; Autosensing
2. Interface / AutonegotiationYes
2. Interface / AutocrossingYes
2. Interface / Change of IP address at runtime, supportedYes; Assignment by higher-level IO-Controller or by the user program with SFB104 "IP_CONF"
Interface types / RJ 45 (Ethernet)Yes
Interface types / Number of ports2
Interface types / integrated switchYes
Protocols / PROFINET IO ControllerYes
Protocols / PROFINET IO deviceYes
Protocols / PROFINET CBAYes
2. Interface / Protocols / PROFIBUS DP masterNo
2. Interface / Protocols / PROFIBUS DP deviceNo
Protocols / Open IE communicationYes
Protocols / Web serverYes
Protocols / Point-to-point connectionNo
Protocols / Media redundancyYes
PROFINET IO Controller / Transmission rate, max.100 Mbit/s
PROFINET IO Controller / Services / PG/OP communicationYes
PROFINET IO Controller / Services / S7 communicationYes
PROFINET IO Controller / Services / Isochronous modeYes; Only with IRT and the High Performance option
PROFINET IO Controller / Services / Shared deviceYes
PROFINET IO Controller / Services / Prioritized startupYes
PROFINET IO Controller / Services / Number of IO devices with prioritized startup, max.32
PROFINET IO Controller / Services / Number of connectable IO Devices, max.256
PROFINET IO Controller / Services / Of which IO devices with IRT, max.64
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. / Of which IO devices with IRT, max. / of which in line, max.64
PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility"256
2. Interface / PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility" / of which in line, max.61
PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max.256
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max.256
PROFINET IO Controller / Services / Activation/deactivation of IO DevicesYes
PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max.8
PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supportedYes
PROFINET IO Controller / Services / Number of IO Devices per tool, max.8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation (partner ports) are supported
PROFINET IO Controller / Services / Device replacement without swap mediumYes
PROFINET IO Controller / Services / Send cycles250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame
PROFINET IO Controller / Services / Updating time250 µs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description
PROFINET IO Controller / Address area / Inputs, max.4 kbyte
PROFINET IO Controller / Address area / Outputs, max.4 kbyte
PROFINET IO Controller / Address area / User data consistency, max.1 024 byte
PROFINET IO Device / Services / PG/OP communicationYes
PROFINET IO Device / Services / S7 communicationYes
PROFINET IO Device / Services / Isochronous modeNo
PROFINET IO Device / Services / IRTYes
PROFINET IO Device / Services / Prioritized startupYes
PROFINET IO Device / Services / Shared deviceYes
PROFINET IO Device / Services / Number of IO Controllers with shared device, max.2
PROFINET IO Device / Transfer memory / Inputs, max.1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Transfer memory / Outputs, max.1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Submodules / Number, max.64
PROFINET IO Device / Submodules / User data per submodule, max.1 024 byte
PROFINET IO Device / PROFINET CBA / acyclic transmissionYes
PROFINET IO Device / PROFINET CBA / cyclic transmissionYes
PROFINET IO Device / Open IE communication / Number of connections, max.46
PROFINET IO Device / Open IE communication / Local port numbers used at the system end0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
PROFINET IO Device / Open IE communication / Keep-alive function, supportedYes
Redundancy mode / Media redundancy / Switchover time on line break, typ.200 ms
Redundancy mode / Media redundancy / Number of stations in the ring, max.50
SIMATIC communication / S7 routingYes
Open IE communication / TCP/IPYes; via integrated PROFINET interface and loadable FBs
Open IE communication / TCP/IP / Number of connections, max.46
Open IE communication / TCP/IP / Data length, max.32 kbyte
Open IE communication / TCP/IP / several passive connections per port, supportedYes
Open IE communication / ISO-on-TCP (RFC1006)Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs
Open IE communication / ISO-on-TCP (RFC1006) / Number of connections, max.46
Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.32 kbyte; 1 452 bytes via CP 443-1 Adv.
Open IE communication / UDPYes; via integrated PROFINET interface and loadable FBs
Open IE communication / UDP / Number of connections, max.46
Open IE communication / UDP / Data length, max.1 472 byte
Web server / supportedYes
Web server / User-defined websitesYes
Web server / Number of HTTP clients5
Isochronous mode / EquidistanceYes
Number of DP masters with isochronous mode1
payload per isochronous device, max.244 byte
Isochronous mode / shortest clock pulse1.5 ms; 0.5 ms without use of SFC 126, 127
Isochronous mode / max. cycle32 ms
PG/OP communicationYes
PG/OP communication / Number of connectable OPs with message processing47; When using Alarm_S/SQ and Alarm_D/DQ
PG/OP communication / Number of connectable OPs without message processing47
Communication functions / Data record routingYes
Global data communication / supportedYes
Global data communication / Number of GD loops, max.8
Global data communication / Number of GD packets, transmitter, max.8
Global data communication / Number of GD packets, receiver, max.16
Global data communication / Size of GD packets, max.54 byte
Global data communication / Size of GD packet (of which consistent), max.1 variable
S7 basic communication / supportedYes
S7 basic communication / User data per job, max.76 byte
S7 basic communication / User data per job (of which consistent), max.1 variable
S7 communication / supportedYes
S7 communication / as serverYes
S7 communication / As clientYes
S7 communication / User data per job, max.64 kbyte
S7 communication / User data per job (of which consistent), max.462 byte; 1 variable
S5 compatible communication / supportedYes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
S5 compatible communication / User data per job, max.8 kbyte
S5 compatible communication / User data per job (of which consistent), max.240 byte
S5 compatible communication / Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.24/24
Standard communication (FMS) / supportedYes; Via CP and loadable FB
PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load20 %
PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners32
PROFINET CBA (at set setpoint communication load) / number of master/device functions150
PROFINET CBA (at set setpoint communication load) / total of all master/device connections4 500
PROFINET CBA (at set setpoint communication load) / data length of all incoming master/device connections, max.45 000 byte
PROFINET CBA (at set setpoint communication load) / data length of all outgoing master/device connections, max.45 000 byte
PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnections1 000
PROFINET CBA (at set setpoint communication load) / Data length of device-internal und PROFIBUS interconnections, max.16 000 byte
PROFINET CBA (at set setpoint communication load) / Data length per connection, max.2 000 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: Transmission interval, min.1 ms; Depending on preset communication load, number of interconnections and data length used
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections300
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections300
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all incoming interconnections, max.4 800 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all outgoing interconnections, max.4 800 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length per connection, max.450 byte
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of stations that can log on for HMI variables (PN OPC/iMap)2x PN OPC/1x iMap
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating500 ms
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables1 000
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max.32 000 byte
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supportedYes; 32 PROFIBUS slaves max. connectable
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max.240 byte; Slave-dependent
Number of connections / overall48
Number of connections / usable for PG communication / reserved for PG communication1
Number of connections / usable for PG communication / adjustable for PG communication, max.0
Number of connections / usable for OP communication / reserved for OP communication1
Number of connections / usable for OP communication / adjustable for OP communication, max.0
Number of connections / usable for S7 basic communication / reserved for S7 basic communication0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.0
Number of connections / usable for S7 communication / reserved for S7 communication0
Number of connections / usable for S7 communication / adjustable for S7 communication, max.0
Number of connections / usable for routing / reserved for routing0
Number of connections / usable for routing / adjustable for routing, max.0
S7 message functions / Number of login stations for message functions, max.47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
S7 message functions / Symbol-related messagesYes
S7 message functions / SCAN procedureYes
S7 message functions / Program alarmsYes
S7 message functions / Process diagnostic messagesYes
S7 message functions / simultaneously active Alarm_S blocks, max.250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
S7 message functions / Alarm 8-blocksYes
Alarm 8-blocks / Number of instances for alarm 8 and S7 communication blocks, max.300
Alarm 8-blocks / preset, max.150
S7 message functions / Process control messagesYes
S7 message functions / Number of archives that can log on simultaneously (SFB 37 AR_SEND)4
Number of messages / overall, max.256
Number of messages / in 100 ms grid, max.0
Number of messages / in 500 ms grid, max.256
Number of messages / in 1000 ms grid, max.256
Number of additional values / with 100 ms grid, max.0
Number of additional values / with 500, 1000 ms grid, max.1
Test commissioning functions / Status blockYes; Up to 16 simultaneously
Test commissioning functions / Single stepYes
Test commissioning functions / Number of breakpoints16
Status/control / Status/control variableYes; Up to 16 variable tables
Status/control / VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Status/control / Number of variables, max.70; Status/control
Forcing / ForcingYes
Forcing / Forcing, variablesInputs/outputs, bit memories, distributed I/Os
Forcing / Number of variables, max.64
Diagnostic buffer / presentYes
Diagnostic buffer / Number of entries, max.400
Diagnostic buffer / Number of entries, max. / can be setYes
Diagnostic buffer / Number of entries, max. / preset120
Service data / Can be read outYes
Emission of radio interference acc. to EN 55 011 / Limit class A, for use in industrial areasYes
Emission of radio interference acc. to EN 55 011 / Limit class B, for use in residential areasNo
Configuration software / STEP 7Yes
Programming / Command setsee instruction list
Programming / Nesting levels7
Programming / Access to consistent data in process imageYes
Programming / System functions (SFC)see instruction list
Programming / System function blocks (SFB)see instruction list
Programming / Programming language / LADYes
Programming / Programming language / FBDYes
Programming / Programming language / STLYes
Programming / Programming language / SCLYes
Programming / Programming language / CFCYes
Programming / Programming language / GRAPHYes
Programming / Programming language / HiGraph®Yes
Programming / Number of simultaneously active SFCs / DPSYC_FR2
Programming / Number of simultaneously active SFCs / D_ACT_DP8
Programming / Number of simultaneously active SFCs / RD_REC8
Programming / Number of simultaneously active SFCs / WR_REC8
Programming / Number of simultaneously active SFCs / WR_PARM8
Programming / Number of simultaneously active SFCs / PARM_MOD1
Programming / Number of simultaneously active SFCs / WR_DPARM2
Programming / Number of simultaneously active SFCs / DPNRM_DG8
Programming / Number of simultaneously active SFCs / RDSYSST8
Programming / Number of simultaneously active SFCs / DP_TOPOL1
Programming / Number of simultaneously active SFBs / RDREC8
Programming / Number of simultaneously active SFBs / WRREC8
Know-how protection / User program protection/password protectionYes
Know-how protection / Block encryptionYes; With S7 block Privacy
Width25 mm
Height290 mm
Depth219 mm
Weight, approx.750 g

Associated Products

ImageProductDescriptionStockViewAdd to RFQ
Siemens 6ES7412-3HJ14-0AB0
6ES7412-3HJ14-0AB0SiemensCPU 412-3H for S7-400H/F/FH, 768 KB, MPI/DP and 2 sync interfacesIn stockView
Siemens 6ES7414-2XK05-0AB0
6ES7414-2XK05-0AB0SiemensCPU 414-2, 1 MB, MPI/DP and PROFIBUS DPIn stockView
Siemens 6ES7414-3XM07-0AB0
6ES7414-3XM07-0AB0SiemensCPU 414-3, 4 MB, MPI/DP, PROFIBUS DP and IF slotIn stockView
Siemens 6ES7416-2XP07-0AB0
6ES7416-2XP07-0AB0SiemensCPU 416-2, 8 MB, MPI/DP and PROFIBUS DPIn stockView
Siemens 6ES7416-3XS07-0AB0
6ES7416-3XS07-0AB0SiemensCPU 416-3, 16 MB, MPI/DP, PROFIBUS DP and IF slotIn stockView
Siemens 6ES7417-4XT05-0AB0
6ES7417-4XT05-0AB0SiemensCPU 417-4, 30 MB, MPI, PROFIBUS DP and 2 IF slotsIn stockView
Siemens 6ES7414-4HM14-0AB0
6ES7414-4HM14-0AB0SiemensCPU 414-4H for S7-400H/F/FH, 2.8 MB, MPI/DP, DP and 2 sync interfacesIn stockView
Siemens 6ES7416-3FS07-0AB0
6ES7416-3FS07-0AB0SiemensCPU 416F-3 PN/DP fail-safe, 16 MB, MPI/DP, PROFINET and IF slotIn stockView
Siemens 6ES7422-1BL00-0AA0
6ES7422-1BL00-0AA0SiemensSM 422 digital output, 32 DO, 24 V DC, 0.5 AIn stockView
Siemens 6ES7421-1BL01-0AA0
6ES7421-1BL01-0AA0SiemensSM 421 digital input, 32 DI, 24 V DCIn stockView
Siemens 6ES7421-7BH01-0AB0
6ES7421-7BH01-0AB0SiemensSM 421 digital input, 16 DI, 24 V DC, interrupt and diagnosticsIn stockView
Siemens 6ES7421-1EL00-0AA0
6ES7421-1EL00-0AA0SiemensSM 421 digital input, 32 DI, 120 V AC/DCIn stockView

Product Questions

Is the 6ES7412-2EK06-0AB0 discontinued?

Yes. Its manufacturer lifecycle status is Discontinued.

Can another Siemens SIMATIC S7-400 part replace it?

Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.

Do you ship worldwide?

Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.

Related Products and Accessories

  • Siemens

    6ES7422-1BH11-0AA0

    SM 422 digital output, 16 DO, 24 V DC, 2 A

    Same SIMATIC S7-400 system

    In stock

  • Siemens

    6ES7422-7BL00-0AB0

    SM 422 digital output, 32 DO, 24 V DC, 0.5 A, diagnostics

    Same SIMATIC S7-400 system

    In stock

  • Siemens

    6ES7492-1CL00-0AA0

    Front connector for S7-400 signal modules, 48-pole, crimp contacts

    Same SIMATIC S7-400 system

    In stock

  • Siemens

    6ES7492-1AL00-0AA0

    Front connector for S7-400 signal modules, 48-pole, screw contacts

    Same SIMATIC S7-400 system

    In stock

Lifecycle Database

Siemens S7-400 Discontinued Parts List (2026)

Siemens status and dates for each S7-400 order number we track: I/O and function modules cancelled 1 October 2026, CPUs, Siemens source. Free CSV.

Open the database

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need a part? Send us the part number.

Added to cart