6ES7412-2EK06-0AB0

Siemens CPU 412-2 PN, 1 MB, MPI/DP and PROFINET

Siemens
Siemens 6ES7412-2EK06-0AB0 CPU 412-2 PN, photo from Siemens data sheet 6ES7412-2EK06-0AB0

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Siemens SIMATIC S7-400 CPU 412-2 PN: central processing unit with 1 MB work memory (0.5 MB code, 0.5 MB data), an MPI/DP interface at 12 Mbit/s and an Ethernet/PROFINET interface.

Manufacturer
Siemens
Manufacturer part no.
6ES7412-2EK06-0AB0
Type
PLC CPU
Lifecycle
Discontinued
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Siemens
Manufacturer part no.
6ES7412-2EK06-0AB0
Type
PLC CPU
Application
PLC controller
Used with
SIMATIC S7-400 rack (system power supply)
Product type designation
CPU 412-2 PN
HW functional status
01
Firmware version
V6.0
Product function / Isochronous mode
Yes; Via PROFIBUS DP or PROFINET interface
Engineering with / Programming package
STEP 7 V5.5 or higher/iMap V3.0 + iMap STEP 7 Add-on V3.0 SP5 or higher
CiR synchronization time, basic load
100 ms
CiR synchronization time, time per I/O byte
30 µs; Time per I/O byte
Supply voltage / Rated value (DC)
Power supply via system power supply
Input current / from backplane bus 5 V DC, typ.
1.1 A
Input current / from backplane bus 5 V DC, max.
1.3 A
Input current / from backplane bus 24 V DC, max.
150 mA; 150 mA per DP interface
Input current / from interface 5 V DC, max.
90 mA; At the DP interface
Power loss, typ.
5.5 W
Storage / Type of memory
RAM
Work memory / Integrated
1 Mbyte
Work memory / integrated (for program)
0.5 Mbyte
Work memory / integrated (for data)
0.5 Mbyte
Work memory / expandable
No
Load memory / expandable FEPROM
Yes; with Memory Card (FLASH)
Load memory / expandable FEPROM, max.
64 Mbyte
Load memory / integrated RAM, max.
512 kbyte
Load memory / expandable RAM
Yes; with Memory Card (RAM)
Load memory / expandable RAM, max.
64 Mbyte
Backup / present
Yes
Backup / with battery
Yes; all data
Show all 398 specifications
Backup / Without battery
No
Backup battery / Backup current, typ.
125 µA; up to 40 °C
Backup battery / Backup current, max.
450 µA
Backup battery / Backup time, max.
Dealt with in the module data manual with the secondary conditions and the factors of influence
Backup battery / Feeding of external backup voltage to CPU
5 V DC to 15 V DC
CPU processing times / for bit operations, typ.
75 ns
CPU processing times / for word operations, typ.
75 ns
CPU processing times / for fixed point arithmetic, typ.
75 ns
CPU processing times / for floating point arithmetic, typ.
225 ns
DB / Number, max.
3 000; Number range: 1 to 16000
DB / Size, max.
64 kbyte
FB / Number, max.
1 500; Number range: 0 to 7999
FB / Size, max.
64 kbyte
FC / Number, max.
1 500; Number range: 0 to 7999
FC / Size, max.
64 kbyte
OB / Number, max.
see instruction list
OB / Size, max.
64 kbyte
OB / Number of free cycle OBs
1; OB 1
OB / Number of time alarm OBs
2; OB 10, 11
OB / Number of delay alarm OBs
2; OB 20, 21
OB / Number of cyclic interrupt OBs
2; OB 32, 35 (shortest cycle that can be set = 500 µs)
OB / Number of process alarm OBs
2; OB 40, 41
OB / Number of DPV1 alarm OBs
3; OB 55-57
OB / Number of isochronous mode OBs
2; OB 61-62
OB / Number of multicomputing OBs
1; OB 60
OB / Number of background OBs
1; OB 90
OB / Number of startup OBs
3; OB 100-102
OB / Number of asynchronous error OBs
9; OB 80-88
OB / Number of synchronous error OBs
2; OB 121, 122
Nesting depth / per priority class
24
Nesting depth / additional within an error OB
1
S7 counter / Number
2 048
S7 counter / Retentivity / can be set
Yes
S7 counter / Retentivity / preset
Z 0 to Z 7
S7 counter / Counting range / lower limit
0
S7 counter / Counting range / upper limit
999
IEC counter / present
Yes
IEC counter / Type
SFB
IEC counter / Number
Unlimited (limited only by RAM capacity)
S7 timer / Number
2 048
S7 timer / Retentivity / can be set
Yes
S7 timer / Retentivity / preset
No times retentive
S7 timer / Time range / lower limit
10 ms
S7 timer / Time range / upper limit
9 990 s
IEC timer / present
Yes
IEC timer / Type
SFB
IEC timer / Number
Unlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.
Total working and load memory (with backup battery)
Flag / Size, max.
4 kbyte; Size of bit memory address area
Flag / Retentivity available
Yes
Flag / Retentivity preset
MB 0 to MB 15
Flag / Number of clock memories
8; in 1 memory byte
Local data / adjustable, max.
8 kbyte
Local data / preset
4 kbyte
I/O address area / Inputs
4 kbyte
I/O address area / Outputs
4 kbyte
Process image / Inputs, adjustable
4 kbyte
Process image / Outputs, adjustable
4 kbyte
Process image / Inputs, default
128 kbyte
Process image / Outputs, default
128 kbyte
Process image / consistent data, max.
244 byte
Process image / Access to consistent data in process image
Yes
Subprocess images / Number of subprocess images, max.
15
Digital channels / Inputs
32 768
Digital channels / Inputs / of which central
32 768
Digital channels / Outputs
32 768
Digital channels / Outputs / of which central
32 768
Analog channels / Inputs
2 048
Analog channels / Inputs / of which central
2 048
Analog channels / Outputs
2 048
Analog channels / Outputs / of which central
2 048
Hardware configuration / Integrated power supply
No
Hardware configuration / Number of expansion units, max.
21
Hardware configuration / connectable OPs
47
Hardware configuration / Multicomputing
Yes; 4 CPUs max. (with UR1 or UR2)
Interface modules / Number of connectable IMs (total), max.
6
Interface modules / Number of connectable IM 460s, max.
6
Interface modules / Number of connectable IM 463s, max.
4; IM 463-2
Number of DP masters / integrated
1
Number of DP masters / via CP
10; CP 443-5 Extended
Number of DP masters / via IM 467
4
Number of DP masters / Mixed mode IM + CP permitted
No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
Number of DP masters / via interface module
0
Number of DP masters / Number of pluggable S5 modules (via adapter capsule in central device), max.
6
Number of IO Controllers / Integrated
1
Number of IO Controllers / Via CP
4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended) / FM
Limited by number of slots and number of connections
Number of operable FMs and CPs (recommended) / CP, PtP
CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections
Number of operable FMs and CPs (recommended) / PROFIBUS and Ethernet CPs
14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
Slots / required slots
1
Clock / Hardware clock (real-time)
Yes
Clock / retentive and synchronizable
Yes
Clock / Resolution
1 ms
Clock / Deviation per day (buffered), max.
1.7 s; Power off
Clock / Deviation per day (unbuffered), max.
8.6 s; For power On
Operating hours counter / Number
16
Operating hours counter / Number/Number range
0 to 15
Operating hours counter / Range of values
SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Operating hours counter / Granularity
1 h
Operating hours counter / retentive
Yes
Clock synchronization / supported
Yes
Clock synchronization / to MPI, master
Yes
Clock synchronization / on MPI, device
Yes
Clock synchronization / to DP, master
Yes
Clock synchronization / on DP, device
Yes
Clock synchronization / in AS, master
Yes
Clock synchronization / in AS, device
Yes
Clock synchronization / on Ethernet via NTP
Yes; As client
Time difference in system when synchronizing via / Ethernet, max.
10 ms
Time difference in system when synchronizing via / MPI, max.
200 ms
Interfaces/bus type
1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports)
Number of RS 485 interfaces
1
Number of other interfaces
0
Interfaces / Optical interface
No
1. Interface / Interface type
MPI/PROFIBUS DP
1. Interface / Isolated
Yes
Interface types / RS 485
Yes
Interface types / Output current of the interface, max.
150 mA
Protocols / MPI
Yes
1. Interface / Protocols / PROFIBUS DP master
Yes
1. Interface / Protocols / PROFIBUS DP device
Yes
MPI / Number of connections
32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
MPI / Transmission rate, max.
12 Mbit/s
MPI / Services / PG/OP communication
Yes
MPI / Services / Routing
Yes
MPI / Services / Global data communication
Yes
MPI / Services / S7 basic communication
Yes
MPI / Services / S7 communication
Yes
MPI / Services / S7 communication, as client
Yes
MPI / Services / S7 communication, as server
Yes
PROFIBUS DP master / Number of connections, max.
16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
PROFIBUS DP master / Transmission rate, max.
12 Mbit/s
PROFIBUS DP master / max. number of DP devices
32
PROFIBUS DP master / Services / PG/OP communication
Yes
PROFIBUS DP master / Services / Routing
Yes
PROFIBUS DP master / Services / Global data communication
No
PROFIBUS DP master / Services / S7 basic communication
Yes
PROFIBUS DP master / Services / S7 communication
Yes
PROFIBUS DP master / Services / S7 communication, as client
Yes
PROFIBUS DP master / Services / S7 communication, as server
Yes
PROFIBUS DP master / Services / Equidistance
Yes
PROFIBUS DP master / Services / Isochronous mode
Yes
PROFIBUS DP master / Services / SYNC/FREEZE
Yes
PROFIBUS DP master / Services / activation/deactivation of DP devices
Yes
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)
Yes
PROFIBUS DP master / Services / DPV1
Yes
PROFIBUS DP master / Address area / Inputs, max.
2 kbyte
PROFIBUS DP master / Address area / Outputs, max.
2 kbyte
PROFIBUS DP master / User data per DP device / user data per DP device, max.
244 byte
PROFIBUS DP master / User data per DP device / Inputs, max.
244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.
244 byte
PROFIBUS DP master / User data per DP device / Slots, max.
244
PROFIBUS DP master / User data per DP device / per slot, max.
128 byte
PROFIBUS DP device / Number of connections
16
PROFIBUS DP device / Transmission rate, max.
12 Mbit/s
PROFIBUS DP device / automatic baud rate search
No
PROFIBUS DP device / Address area, max.
32; Virtual slots
PROFIBUS DP device / User data per address area, max.
32 byte
PROFIBUS DP device / User data per address area, max. / of which consistent, max.
32 byte
PROFIBUS DP device / Services / PG/OP communication
Yes; with interface active
PROFIBUS DP device / Services / Routing
Yes; with interface active
PROFIBUS DP device / Services / Global data communication
No
PROFIBUS DP device / Services / S7 basic communication
No
PROFIBUS DP device / Services / S7 communication
Yes
PROFIBUS DP device / Services / S7 communication, as client
Yes
PROFIBUS DP device / Services / S7 communication, as server
Yes
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)
No
PROFIBUS DP device / Services / DPV1
No
PROFIBUS DP device / Transfer memory / Inputs
244 byte
PROFIBUS DP device / Transfer memory / Outputs
244 byte
2. Interface / Interface type
PROFINET
2. Interface / Isolated
Yes
2. Interface / automatic detection of transmission rate
Yes; Autosensing
2. Interface / Autonegotiation
Yes
2. Interface / Autocrossing
Yes
2. Interface / Change of IP address at runtime, supported
Yes; Assignment by higher-level IO-Controller or by the user program with SFB104 "IP_CONF"
Interface types / RJ 45 (Ethernet)
Yes
Interface types / Number of ports
2
Interface types / integrated switch
Yes
Protocols / PROFINET IO Controller
Yes
Protocols / PROFINET IO device
Yes
Protocols / PROFINET CBA
Yes
2. Interface / Protocols / PROFIBUS DP master
No
2. Interface / Protocols / PROFIBUS DP device
No
Protocols / Open IE communication
Yes
Protocols / Web server
Yes
Protocols / Point-to-point connection
No
Protocols / Media redundancy
Yes
PROFINET IO Controller / Transmission rate, max.
100 Mbit/s
PROFINET IO Controller / Services / PG/OP communication
Yes
PROFINET IO Controller / Services / S7 communication
Yes
PROFINET IO Controller / Services / Isochronous mode
Yes; Only with IRT and the High Performance option
PROFINET IO Controller / Services / Shared device
Yes
PROFINET IO Controller / Services / Prioritized startup
Yes
PROFINET IO Controller / Services / Number of IO devices with prioritized startup, max.
32
PROFINET IO Controller / Services / Number of connectable IO Devices, max.
256
PROFINET IO Controller / Services / Of which IO devices with IRT, max.
64
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. / Of which IO devices with IRT, max. / of which in line, max.
64
PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility"
256
2. Interface / PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility" / of which in line, max.
61
PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max.
256
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max.
256
PROFINET IO Controller / Services / Activation/deactivation of IO Devices
Yes
PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max.
8
PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supported
Yes
PROFINET IO Controller / Services / Number of IO Devices per tool, max.
8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation (partner ports) are supported
PROFINET IO Controller / Services / Device replacement without swap medium
Yes
PROFINET IO Controller / Services / Send cycles
250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame
PROFINET IO Controller / Services / Updating time
250 µs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description
PROFINET IO Controller / Address area / Inputs, max.
4 kbyte
PROFINET IO Controller / Address area / Outputs, max.
4 kbyte
PROFINET IO Controller / Address area / User data consistency, max.
1 024 byte
PROFINET IO Device / Services / PG/OP communication
Yes
PROFINET IO Device / Services / S7 communication
Yes
PROFINET IO Device / Services / Isochronous mode
No
PROFINET IO Device / Services / IRT
Yes
PROFINET IO Device / Services / Prioritized startup
Yes
PROFINET IO Device / Services / Shared device
Yes
PROFINET IO Device / Services / Number of IO Controllers with shared device, max.
2
PROFINET IO Device / Transfer memory / Inputs, max.
1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Transfer memory / Outputs, max.
1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Submodules / Number, max.
64
PROFINET IO Device / Submodules / User data per submodule, max.
1 024 byte
PROFINET IO Device / PROFINET CBA / acyclic transmission
Yes
PROFINET IO Device / PROFINET CBA / cyclic transmission
Yes
PROFINET IO Device / Open IE communication / Number of connections, max.
46
PROFINET IO Device / Open IE communication / Local port numbers used at the system end
0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
PROFINET IO Device / Open IE communication / Keep-alive function, supported
Yes
Redundancy mode / Media redundancy / Switchover time on line break, typ.
200 ms
Redundancy mode / Media redundancy / Number of stations in the ring, max.
50
SIMATIC communication / S7 routing
Yes
Open IE communication / TCP/IP
Yes; via integrated PROFINET interface and loadable FBs
Open IE communication / TCP/IP / Number of connections, max.
46
Open IE communication / TCP/IP / Data length, max.
32 kbyte
Open IE communication / TCP/IP / several passive connections per port, supported
Yes
Open IE communication / ISO-on-TCP (RFC1006)
Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs
Open IE communication / ISO-on-TCP (RFC1006) / Number of connections, max.
46
Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.
32 kbyte; 1 452 bytes via CP 443-1 Adv.
Open IE communication / UDP
Yes; via integrated PROFINET interface and loadable FBs
Open IE communication / UDP / Number of connections, max.
46
Open IE communication / UDP / Data length, max.
1 472 byte
Web server / supported
Yes
Web server / User-defined websites
Yes
Web server / Number of HTTP clients
5
Isochronous mode / Equidistance
Yes
Number of DP masters with isochronous mode
1
payload per isochronous device, max.
244 byte
Isochronous mode / shortest clock pulse
1.5 ms; 0.5 ms without use of SFC 126, 127
Isochronous mode / max. cycle
32 ms
PG/OP communication
Yes
PG/OP communication / Number of connectable OPs with message processing
47; When using Alarm_S/SQ and Alarm_D/DQ
PG/OP communication / Number of connectable OPs without message processing
47
Communication functions / Data record routing
Yes
Global data communication / supported
Yes
Global data communication / Number of GD loops, max.
8
Global data communication / Number of GD packets, transmitter, max.
8
Global data communication / Number of GD packets, receiver, max.
16
Global data communication / Size of GD packets, max.
54 byte
Global data communication / Size of GD packet (of which consistent), max.
1 variable
S7 basic communication / supported
Yes
S7 basic communication / User data per job, max.
76 byte
S7 basic communication / User data per job (of which consistent), max.
1 variable
S7 communication / supported
Yes
S7 communication / as server
Yes
S7 communication / As client
Yes
S7 communication / User data per job, max.
64 kbyte
S7 communication / User data per job (of which consistent), max.
462 byte; 1 variable
S5 compatible communication / supported
Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
S5 compatible communication / User data per job, max.
8 kbyte
S5 compatible communication / User data per job (of which consistent), max.
240 byte
S5 compatible communication / Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.
24/24
Standard communication (FMS) / supported
Yes; Via CP and loadable FB
PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load
20 %
PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners
32
PROFINET CBA (at set setpoint communication load) / number of master/device functions
150
PROFINET CBA (at set setpoint communication load) / total of all master/device connections
4 500
PROFINET CBA (at set setpoint communication load) / data length of all incoming master/device connections, max.
45 000 byte
PROFINET CBA (at set setpoint communication load) / data length of all outgoing master/device connections, max.
45 000 byte
PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnections
1 000
PROFINET CBA (at set setpoint communication load) / Data length of device-internal und PROFIBUS interconnections, max.
16 000 byte
PROFINET CBA (at set setpoint communication load) / Data length per connection, max.
2 000 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: Transmission interval, min.
1 ms; Depending on preset communication load, number of interconnections and data length used
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections
300
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections
300
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all incoming interconnections, max.
4 800 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all outgoing interconnections, max.
4 800 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length per connection, max.
450 byte
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of stations that can log on for HMI variables (PN OPC/iMap)
2x PN OPC/1x iMap
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating
500 ms
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables
1 000
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max.
32 000 byte
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supported
Yes; 32 PROFIBUS slaves max. connectable
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max.
240 byte; Slave-dependent
Number of connections / overall
48
Number of connections / usable for PG communication / reserved for PG communication
1
Number of connections / usable for PG communication / adjustable for PG communication, max.
0
Number of connections / usable for OP communication / reserved for OP communication
1
Number of connections / usable for OP communication / adjustable for OP communication, max.
0
Number of connections / usable for S7 basic communication / reserved for S7 basic communication
0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.
0
Number of connections / usable for S7 communication / reserved for S7 communication
0
Number of connections / usable for S7 communication / adjustable for S7 communication, max.
0
Number of connections / usable for routing / reserved for routing
0
Number of connections / usable for routing / adjustable for routing, max.
0
S7 message functions / Number of login stations for message functions, max.
47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
S7 message functions / Symbol-related messages
Yes
S7 message functions / SCAN procedure
Yes
S7 message functions / Program alarms
Yes
S7 message functions / Process diagnostic messages
Yes
S7 message functions / simultaneously active Alarm_S blocks, max.
250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
S7 message functions / Alarm 8-blocks
Yes
Alarm 8-blocks / Number of instances for alarm 8 and S7 communication blocks, max.
300
Alarm 8-blocks / preset, max.
150
S7 message functions / Process control messages
Yes
S7 message functions / Number of archives that can log on simultaneously (SFB 37 AR_SEND)
4
Number of messages / overall, max.
256
Number of messages / in 100 ms grid, max.
0
Number of messages / in 500 ms grid, max.
256
Number of messages / in 1000 ms grid, max.
256
Number of additional values / with 100 ms grid, max.
0
Number of additional values / with 500, 1000 ms grid, max.
1
Test commissioning functions / Status block
Yes; Up to 16 simultaneously
Test commissioning functions / Single step
Yes
Test commissioning functions / Number of breakpoints
16
Status/control / Status/control variable
Yes; Up to 16 variable tables
Status/control / Variables
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Status/control / Number of variables, max.
70; Status/control
Forcing / Forcing
Yes
Forcing / Forcing, variables
Inputs/outputs, bit memories, distributed I/Os
Forcing / Number of variables, max.
64
Diagnostic buffer / present
Yes
Diagnostic buffer / Number of entries, max.
400
Diagnostic buffer / Number of entries, max. / can be set
Yes
Diagnostic buffer / Number of entries, max. / preset
120
Service data / Can be read out
Yes
Emission of radio interference acc. to EN 55 011 / Limit class A, for use in industrial areas
Yes
Emission of radio interference acc. to EN 55 011 / Limit class B, for use in residential areas
No
Configuration software / STEP 7
Yes
Programming / Command set
see instruction list
Programming / Nesting levels
7
Programming / Access to consistent data in process image
Yes
Programming / System functions (SFC)
see instruction list
Programming / System function blocks (SFB)
see instruction list
Programming / Programming language / LAD
Yes
Programming / Programming language / FBD
Yes
Programming / Programming language / STL
Yes
Programming / Programming language / SCL
Yes
Programming / Programming language / CFC
Yes
Programming / Programming language / GRAPH
Yes
Programming / Programming language / HiGraph®
Yes
Programming / Number of simultaneously active SFCs / DPSYC_FR
2
Programming / Number of simultaneously active SFCs / D_ACT_DP
8
Programming / Number of simultaneously active SFCs / RD_REC
8
Programming / Number of simultaneously active SFCs / WR_REC
8
Programming / Number of simultaneously active SFCs / WR_PARM
8
Programming / Number of simultaneously active SFCs / PARM_MOD
1
Programming / Number of simultaneously active SFCs / WR_DPARM
2
Programming / Number of simultaneously active SFCs / DPNRM_DG
8
Programming / Number of simultaneously active SFCs / RDSYSST
8
Programming / Number of simultaneously active SFCs / DP_TOPOL
1
Programming / Number of simultaneously active SFBs / RDREC
8
Programming / Number of simultaneously active SFBs / WRREC
8
Know-how protection / User program protection/password protection
Yes
Know-how protection / Block encryption
Yes; With S7 block Privacy
Width
25 mm
Height
290 mm
Depth
219 mm
Weight, approx.
750 g

Technical documents (1)

Key features

  • 1 MB work memory: 0.5 MB code, 0.5 MB data
  • 1st interface MPI/PROFIBUS DP 12 Mbit/s (X1)
  • 2nd interface Ethernet/PROFINET (X5), media redundancy
  • Isochronous mode via PROFIBUS DP or PROFINET
  • Powered from the S7-400 system power supply

About the Siemens 6ES7412-2EK06-0AB0

The Siemens 6ES7412-2EK06-0AB0 is the CPU 412-2 PN, the entry CPU of the S7-400 with PROFINET. Siemens's data sheet gives it 1 MB of work memory, split into 0.5 MB for code and 0.5 MB for data, a combined MPI/PROFIBUS DP interface at 12 Mbit/s and an Ethernet/PROFINET interface. It is powered from the S7-400 rack's system power supply.

What is the 6ES7412-2EK06-0AB0 used for?

It runs S7-400 stations that need PROFINET but not a large program, such as smaller lines and plant sections, with I/O in the rack and on PROFIBUS DP or PROFINET.

Lifecycle and successor

Discontinued.

Before you order

What to photograph or confirm so the right unit is quoted.

Check the full order number and the firmware version on the CPU's front label; send a photo of it. S7-400 CPUs of the same type differ by order number in memory and interfaces, so quote against the exact number, and list any interface modules (IF) fitted.

Alternatives for 6ES7412-2EK06-0AB0

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
Siemens 6ES7412-3HJ14-0AB0CPU 412-3H for S7-400H/F/FH, 768 KB, MPI/DP and 2 sync interfacesSiemensRedundant PLC CPU (H-CPU)DiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7414-2XK05-0AB0CPU 414-2, 1 MB, MPI/DP and PROFIBUS DPSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7414-3XM07-0AB0CPU 414-3, 4 MB, MPI/DP, PROFIBUS DP and IF slotSiemensPLC CPUActiveSame familyOn RequestOn requestView ›
Siemens 6ES7416-2XP07-0AB0CPU 416-2, 8 MB, MPI/DP and PROFIBUS DPSiemensPLC CPUActiveSame familyOn RequestOn requestView ›
Siemens 6ES7416-3XS07-0AB0CPU 416-3, 16 MB, MPI/DP, PROFIBUS DP and IF slotSiemensPLC CPUActiveSame familyOn RequestOn requestView ›
Siemens 6ES7417-4XT05-0AB0CPU 417-4, 30 MB, MPI, PROFIBUS DP and 2 IF slotsSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7414-4HM14-0AB0CPU 414-4H for S7-400H/F/FH, 2.8 MB, MPI/DP, DP and 2 sync interfacesSiemensRedundant PLC CPU (H-CPU)DiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7416-3FS07-0AB0CPU 416F-3 PN/DP fail-safe, 16 MB, MPI/DP, PROFINET and IF slotSiemensSafety PLC CPU (F-CPU)ActiveSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Siemens 6ES7412-2EK06-0AB0? Send us the details.