Image is for illustrative purposes only. Please refer to product description.
Delivery options
Siemens SIMATIC S7-400 CPU 416-3: central processing unit with 16 MB work memory (8 MB code, 8 MB data), an MPI/DP interface at 12 Mbit/s, a PROFIBUS DP interface and a slot for a plug-in interface module.
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7416-3XS07-0AB0
- Product family
- SIMATIC S7-400 PLC CPUs
- Type
- PLC CPU
- Lifecycle
- Active
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7416-3XS07-0AB0
- Type
- PLC CPU
- Application
- PLC controller
- Used with
- SIMATIC S7-400 rack (system power supply)
- Product type designation
- CPU 416-3
- HW functional status
- 01
- Firmware version
- V7.0
- Product function / Isochronous mode
- Yes; For PROFIBUS only
- Engineering with / Programming package
- STEP 7 V5.4 or higher with HSP 261
- CiR synchronization time, basic load
- 100 ms
- CiR synchronization time, time per I/O byte
- 10 µs
- Supply voltage / Rated value (DC)
- Power supply via system power supply
- Input current / from backplane bus 5 V DC, typ.
- 1.1 A
- Input current / from backplane bus 5 V DC, max.
- 1.3 A
- Input current / from backplane bus 24 V DC, max.
- 450 mA; 150 mA per DP interface
- Input current / from interface 5 V DC, max.
- 90 mA; At each DP interface
- Power loss, typ.
- 5.5 W
- Storage / Type of memory
- RAM
- Work memory / integrated
- 16 Mbyte
- Work memory / integrated (for program)
- 8 Mbyte
- Work memory / integrated (for data)
- 8 Mbyte
- Work memory / expandable
- No
- Load memory / expandable FEPROM
- Yes; with Memory Card (FLASH)
- Load memory / expandable FEPROM, max.
- 64 Mbyte
- Load memory / integrated RAM, max.
- 1 Mbyte
- Load memory / expandable RAM
- Yes; with Memory Card (RAM)
- Load memory / expandable RAM, max.
- 64 Mbyte
- Backup / present
- Yes
- Backup / with battery
- Yes; all data
Show all 338 specificationsShow fewer
- Backup / without battery
- No
- Backup battery / Backup current, typ.
- 180 µA; up to 40 °C
- Backup battery / Backup current, max.
- 850 µA
- Backup battery / Backup time, max.
- Dealt with in the module data manual with the secondary conditions and the factors of influence
- Backup battery / Feeding of external backup voltage to CPU
- 5 V DC to 15 V DC
- CPU processing times / for bit operations, typ.
- 12.5 ns
- CPU processing times / for word operations, typ.
- 12.5 ns
- CPU processing times / for fixed point arithmetic, typ.
- 12.5 ns
- CPU processing times / for floating point arithmetic, typ.
- 25 ns
- DB / Number, max.
- 10 000; Number range: 1 to 16000
- DB / Size, max.
- 64 kbyte
- FB / Number, max.
- 5 000; Number range: 0 to 7999
- FB / Size, max.
- 64 kbyte
- FC / Number, max.
- 5 000; Number range: 0 to 7999
- FC / Size, max.
- 64 kbyte
- OB / Number, max.
- see instruction list
- OB / Size, max.
- 64 kbyte
- OB / Number of free cycle OBs
- 1; OB 1
- OB / Number of time alarm OBs
- 8; OB 10-17
- OB / Number of delay alarm OBs
- 4; OB 20-23
- OB / Number of cyclic interrupt OBs
- 9; OB 30-38 (shortest cycle that can be set = 500 µs)
- OB / Number of process alarm OBs
- 8; OB 40-47
- OB / Number of DPV1 alarm OBs
- 3; OB 55-57
- OB / Number of isochronous mode OBs
- 4; OB 61-64
- OB / Number of multicomputing OBs
- 1; OB 60
- OB / Number of background OBs
- 1; OB 90
- OB / Number of startup OBs
- 3; OB 100-102
- OB / Number of asynchronous error OBs
- 9; OB 80-88
- OB / Number of synchronous error OBs
- 2; OB 121, 122
- Nesting depth / per priority class
- 24
- Nesting depth / additional within an error OB
- 2
- S7 counter / Number
- 2 048
- S7 counter / Retentivity / adjustable
- Yes
- S7 counter / Retentivity / preset
- Z 0 to Z 7
- S7 counter / Counting range / lower limit
- 0
- S7 counter / Counting range / upper limit
- 999
- IEC counter / present
- Yes
- IEC counter / Type
- SFB
- IEC counter / Number
- Unlimited (limited only by RAM capacity)
- S7 timer / Number
- 2 048
- S7 timer / Retentivity / adjustable
- Yes
- S7 timer / Retentivity / preset
- No times retentive
- S7 timer / Time range / lower limit
- 10 ms
- S7 timer / Time range / upper limit
- 9 990 s
- IEC timer / present
- Yes
- IEC timer / Type
- SFB
- IEC timer / Number
- Unlimited (limited only by RAM capacity)
- Retentive data area (incl. timers, counters, flags), max.
- Total working and load memory (with backup battery)
- Flag / Size, max.
- 16 kbyte; Size of bit memory address area
- Flag / Retentivity available
- Yes
- Flag / Retentivity preset
- MB 0 to MB 15
- Flag / Number of clock memories
- 8; in 1 memory byte
- Local data / adjustable, max.
- 32 kbyte
- Local data / preset
- 16 kbyte
- I/O address area / Inputs
- 16 kbyte
- I/O address area / Outputs
- 16 kbyte
- Process image / Inputs, adjustable
- 16 kbyte
- Process image / Outputs, adjustable
- 16 kbyte
- Process image / Inputs, default
- 512 byte
- Process image / Outputs, default
- 512 byte
- Process image / consistent data, max.
- 244 byte
- Process image / Access to consistent data in process image
- Yes
- Subprocess images / Number of subprocess images, max.
- 15
- Digital channels / Inputs
- 131 072
- Digital channels / Inputs / of which central
- 131 072
- Digital channels / Outputs
- 131 072
- Digital channels / Outputs / of which central
- 131 072
- Analog channels / Inputs
- 8 192
- Analog channels / Inputs / of which central
- 8 192
- Analog channels / Outputs
- 8 192
- Analog channels / Outputs / of which central
- 8 192
- Hardware configuration / Number of expansion units, max.
- 21
- Hardware configuration / connectable OPs
- 95
- Hardware configuration / Multicomputing
- Yes; 4 CPUs max. (with UR1 or UR2)
- Interface modules / Number of connectable IMs (total), max.
- 6
- Interface modules / Number of connectable IM 460s, max.
- 6
- Interface modules / Number of connectable IM 463s, max.
- 4; IM 463-2
- Number of DP masters / integrated
- 2
- Number of DP masters / via CP
- 10; CP 443-5 Extended
- Number of DP masters / via IM 467
- 4
- Number of DP masters / Mixed mode IM + CP permitted
- No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode
- Number of DP masters / via interface module
- 1
- Number of DP masters / Number of pluggable S5 modules (via adapter capsule in central device), max.
- 6
- Number of IO Controllers / Integrated
- 0
- Number of IO Controllers / Via CP
- 4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode
- Number of operable FMs and CPs (recommended) / FM
- Limited by number of slots and number of connections
- Number of operable FMs and CPs (recommended) / CP, PtP
- CP 440: Limited by number of slots; CP 441: limited by number of connections
- Number of operable FMs and CPs (recommended) / PROFIBUS and Ethernet CPs
- 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
- Slots / required slots
- 2
- Clock / Hardware clock (real-time)
- Yes
- Clock / retentive and synchronizable
- Yes
- Clock / Resolution
- 1 ms
- Clock / Deviation per day (buffered), max.
- 1.7 s; Power off
- Clock / Deviation per day (unbuffered), max.
- 8.6 s; For power On
- Operating hours counter / Number
- 16
- Operating hours counter / Number/Number range
- 0 to 15
- Operating hours counter / Range of values
- SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
- Operating hours counter / Granularity
- 1 h
- Operating hours counter / retentive
- Yes
- Clock synchronization / supported
- Yes
- Clock synchronization / to MPI, master
- Yes
- Clock synchronization / on MPI, device
- Yes
- Clock synchronization / to DP, master
- Yes
- Clock synchronization / on DP, device
- Yes
- Clock synchronization / in AS, master
- Yes
- Clock synchronization / in AS, device
- Yes
- Clock synchronization / on Ethernet via NTP
- No; Via CP
- Clock synchronization / to IF 964 DP
- Yes
- Time difference in system when synchronizing via / MPI, max.
- 200 ms
- Interfaces/bus type
- 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable)
- Number of RS 485 interfaces
- 2; Combined MPI / PROFIBUS DP and PROFIBUS DP
- Number of other interfaces
- 1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04- 0AB0)
- 1. Interface / Interface type
- MPI/PROFIBUS DP
- 1. Interface / Isolated
- Yes
- Interface types / RS 485
- Yes
- Interface types / Output current of the interface, max.
- 150 mA
- 1. Interface / Protocols / MPI
- Yes
- Protocols / PROFIBUS DP master
- Yes
- Protocols / PROFIBUS DP device
- Yes
- MPI / Number of connections
- 44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
- MPI / Transmission rate, max.
- 12 Mbit/s
- MPI / Services / PG/OP communication
- Yes
- MPI / Services / Routing
- Yes
- MPI / Services / Global data communication
- Yes
- MPI / Services / S7 basic communication
- Yes
- MPI / Services / S7 communication
- Yes
- MPI / Services / S7 communication, as client
- Yes
- MPI / Services / S7 communication, as server
- Yes
- 1. Interface / PROFIBUS DP master / Number of connections, max.
- 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
- PROFIBUS DP master / Transmission rate, max.
- 12 Mbit/s
- 1. Interface / PROFIBUS DP master / max. number of DP devices
- 32
- PROFIBUS DP master / Services / PG/OP communication
- Yes
- PROFIBUS DP master / Services / Routing
- Yes; S7 routing
- PROFIBUS DP master / Services / Global data communication
- No
- PROFIBUS DP master / Services / S7 basic communication
- Yes
- PROFIBUS DP master / Services / S7 communication
- Yes
- PROFIBUS DP master / Services / S7 communication, as client
- Yes
- PROFIBUS DP master / Services / S7 communication, as server
- Yes
- PROFIBUS DP master / Services / Equidistance
- Yes
- PROFIBUS DP master / Services / Isochronous mode
- Yes
- PROFIBUS DP master / Services / SYNC/FREEZE
- Yes
- PROFIBUS DP master / Services / activation/deactivation of DP devices
- Yes
- PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)
- Yes
- PROFIBUS DP master / Services / DPV1
- Yes
- 1. Interface / PROFIBUS DP master / Address area / Inputs, max.
- 2 kbyte
- 1. Interface / PROFIBUS DP master / Address area / Outputs, max.
- 2 kbyte
- PROFIBUS DP master / User data per DP device / user data per DP device, max.
- 244 byte
- PROFIBUS DP master / User data per DP device / Inputs, max.
- 244 byte
- PROFIBUS DP master / User data per DP device / Outputs, max.
- 244 byte
- PROFIBUS DP master / User data per DP device / Slots, max.
- 244
- PROFIBUS DP master / User data per DP device / per slot, max.
- 128 byte
- PROFIBUS DP device / Number of connections
- 32
- PROFIBUS DP device / Transmission rate, max.
- 12 Mbit/s
- PROFIBUS DP device / automatic baud rate search
- No
- 1. Interface / PROFIBUS DP device / Address area, max.
- 32; Virtual slots
- PROFIBUS DP device / User data per address area, max.
- 32 byte
- PROFIBUS DP device / User data per address area, max. / of which consistent, max.
- 32 byte
- 1. Interface / PROFIBUS DP device / Services / PG/OP communication
- Yes; with interface active
- PROFIBUS DP device / Services / Routing
- Yes; with interface active
- PROFIBUS DP device / Services / Global data communication
- No
- PROFIBUS DP device / Services / S7 basic communication
- No
- PROFIBUS DP device / Services / S7 communication
- Yes
- PROFIBUS DP device / Services / S7 communication, as client
- Yes
- PROFIBUS DP device / Services / S7 communication, as server
- Yes
- PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)
- No
- PROFIBUS DP device / Services / DPV1
- No
- PROFIBUS DP device / Transfer memory / Inputs
- 244 byte
- PROFIBUS DP device / Transfer memory / Outputs
- 244 byte
- 2. Interface / Interface type
- PROFIBUS DP
- 2. Interface / Isolated
- Yes
- 2. Interface / PROFIBUS DP master / Number of connections, max.
- 32
- 2. Interface / PROFIBUS DP master / max. number of DP devices
- 125
- 2. Interface / PROFIBUS DP master / Address area / Inputs, max.
- 8 kbyte
- 2. Interface / PROFIBUS DP master / Address area / Outputs, max.
- 8 kbyte
- 2. Interface / PROFIBUS DP device / Address area, max.
- 32
- 3. Interface / Interface type
- pluggable interface module (IF), technical data as for 2nd interface
- 3. Interface / Plug-in interface modules
- IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)
- 3. Interface / Isolated
- Yes
- 3. Interface / automatic detection of transmission rate
- No
- 3. Interface / Protocols / MPI
- No
- 3. Interface / PROFIBUS DP master / Number of connections, max.
- 32
- 3. Interface / PROFIBUS DP master / max. number of DP devices
- 125
- PROFIBUS DP master / Services / DPV0
- Yes
- 3. Interface / PROFIBUS DP master / Address area / Inputs, max.
- 8 kbyte
- 3. Interface / PROFIBUS DP master / Address area / Outputs, max.
- 8 kbyte
- 3. Interface / PROFIBUS DP device / Address area, max.
- 32
- 3. Interface / PROFIBUS DP device / Services / PG/OP communication
- Yes
- SIMATIC communication / S7 routing
- Yes
- Open IE communication / ISO-on-TCP (RFC1006)
- Via CP 443-1 and loadable FB
- Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.
- 1 452 bytes via CP 443-1 Adv.
- Web server / supported
- No
- Isochronous mode / Equidistance
- Yes
- Number of DP masters with isochronous mode
- 3
- payload per isochronous device, max.
- 244 byte
- Isochronous mode / shortest clock pulse
- 1 ms; 0.5 ms without use of SFC 126, 127
- Isochronous mode / max. cycle
- 32 ms
- PG/OP communication
- Yes
- PG/OP communication / Number of connectable OPs with message processing
- 95; When using Alarm_S/SQ and Alarm_D/DQ
- PG/OP communication / Number of connectable OPs without message processing
- 95
- Communication functions / Data record routing
- Yes
- Global data communication / supported
- Yes
- Global data communication / Number of GD loops, max.
- 16
- Global data communication / Number of GD packets, transmitter, max.
- 16
- Global data communication / Number of GD packets, receiver, max.
- 32
- Global data communication / Size of GD packets, max.
- 54 byte
- Global data communication / Size of GD packet (of which consistent), max.
- 1 variable
- S7 basic communication / supported
- Yes
- S7 basic communication / User data per job, max.
- 76 byte
- S7 basic communication / User data per job (of which consistent), max.
- 1 variable
- S7 communication / supported
- Yes
- S7 communication / as server
- Yes
- S7 communication / as client
- Yes
- S7 communication / User data per job, max.
- 64 kbyte
- S7 communication / User data per job (of which consistent), max.
- 462 byte; 1 variable
- S5 compatible communication / supported
- Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
- S5 compatible communication / User data per job, max.
- 8 kbyte
- S5 compatible communication / User data per job (of which consistent), max.
- 240 byte
- S5 compatible communication / Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.
- 64/64
- Standard communication (FMS) / supported
- Yes; Via CP and loadable FB
- Number of connections / overall
- 96
- Number of connections / usable for PG communication
- 95
- Number of connections / usable for PG communication / reserved for PG communication
- 1
- Number of connections / usable for PG communication / adjustable for PG communication, max.
- 0
- Number of connections / usable for OP communication
- 95
- Number of connections / usable for OP communication / reserved for OP communication
- 1
- Number of connections / usable for OP communication / adjustable for OP communication, max.
- 0
- Number of connections / usable for S7 basic communication
- 94
- Number of connections / usable for S7 basic communication / reserved for S7 basic communication
- 0
- Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.
- 0
- Number of connections / usable for S7 communication
- 94
- Number of connections / usable for S7 communication / reserved for S7 communication
- 0
- Number of connections / usable for S7 communication / adjustable for S7 communication, max.
- 0
- Number of connections / usable for routing
- 47
- Number of connections / usable for routing / reserved for routing
- 0
- Number of connections / usable for routing / adjustable for routing, max.
- 0
- S7 message functions / Number of login stations for message functions, max.
- 95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
- S7 message functions / Symbol-related messages
- Yes
- S7 message functions / SCAN procedure
- Yes
- S7 message functions / Program alarms
- Yes
- S7 message functions / Process diagnostic messages
- Yes
- S7 message functions / simultaneously active Alarm_S blocks, max.
- 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
- S7 message functions / Alarm 8-blocks
- Yes
- Alarm 8-blocks / Number of instances for alarm 8 and S7 communication blocks, max.
- 4 000
- Alarm 8-blocks / preset, max.
- 600
- S7 message functions / Process control messages
- Yes
- S7 message functions / Number of archives that can log on simultaneously (SFB 37 AR_SEND)
- 32
- Number of messages / overall, max.
- 1 024
- Number of messages / in 100 ms grid, max.
- 128
- Number of messages / in 500 ms grid, max.
- 512
- Number of messages / in 1000 ms grid, max.
- 1 024
- Number of additional values / with 100 ms grid, max.
- 1
- Number of additional values / with 500, 1000 ms grid, max.
- 10
- Test commissioning functions / Status block
- Yes; Up to 16 simultaneously
- Test commissioning functions / Single step
- Yes
- Test commissioning functions / Number of breakpoints
- 16
- Status/control / Status/control variable
- Yes; Up to 16 variable tables
- Status/control / Variables
- Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
- Status/control / Number of variables, max.
- 70; Status/control
- Forcing / Forcing
- Yes
- Forcing / Forcing, variables
- Inputs, outputs, bit memories, peripheral inputs, peripheral outputs
- Forcing / Number of variables, max.
- 512
- Diagnostic buffer / present
- Yes
- Diagnostic buffer / Number of entries, max.
- 3 200
- Diagnostic buffer / Number of entries, max. / can be set
- Yes
- Diagnostic buffer / Number of entries, max. / preset
- 120
- Service data / Can be read out
- Yes
- Standards, approvals, certificates / CE mark
- Yes
- Standards, approvals, certificates / CSA approval
- Yes
- Standards, approvals, certificates / UL approval
- Yes
- Standards, approvals, certificates / cULus
- Yes
- Standards, approvals, certificates / FM approval
- Yes
- Standards, approvals, certificates / RCM (formerly C-TICK)
- Yes
- Standards, approvals, certificates / KC approval
- Yes
- Standards, approvals, certificates / EAC (formerly Gost-R)
- Yes
- Use in hazardous areas / ATEX marking
- ATEX II 3G Ex nA IIC T4 Gc
- Ambient temperature during operation / min.
- 0 °C
- Ambient temperature during operation / max.
- 60 °C
- Configuration software / STEP 7
- Yes
- Programming / Command set
- see instruction list
- Programming / Nesting levels
- 7
- Programming / Access to consistent data in process image
- Yes
- Programming / System functions (SFC)
- see instruction list
- Programming / System function blocks (SFB)
- see instruction list
- Programming / Programming language / LAD
- Yes
- Programming / Programming language / FBD
- Yes
- Programming / Programming language / STL
- Yes
- Programming / Programming language / SCL
- Yes
- Programming / Programming language / CFC
- Yes
- Programming / Programming language / GRAPH
- Yes
- Programming / Programming language / HiGraph®
- Yes
- Programming / Number of simultaneously active SFCs / DPSYC_FR
- 2; SFC 11; per interface
- Programming / Number of simultaneously active SFCs / D_ACT_DP
- 8; SFC 12; per interface
- Programming / Number of simultaneously active SFCs / RD_REC
- 8; SFC 59; per interface
- Programming / Number of simultaneously active SFCs / WR_REC
- 8; SFC 58; per interface
- Programming / Number of simultaneously active SFCs / WR_PARM
- 8; SFC 55; per interface
- Programming / Number of simultaneously active SFCs / PARM_MOD
- 1; SFC 57; per interface
- Programming / Number of simultaneously active SFCs / WR_DPARM
- 2; SFC 56; per interface
- Programming / Number of simultaneously active SFCs / DPNRM_DG
- 8; SFC 13; per interface
- Programming / Number of simultaneously active SFCs / RDSYSST
- 8; SFC 51
- Programming / Number of simultaneously active SFCs / DP_TOPOL
- 1; SFC 103; per interface
- Programming / Number of simultaneously active SFBs / RDREC
- 8; SFB 52; per interface, but not more than 32 across all external interfaces
- Programming / Number of simultaneously active SFBs / WRREC
- 8; SFB 53; per interface, but not more than 32 across all external interfaces
- Know-how protection / User program protection/password protection
- Yes
- Know-how protection / Block encryption
- Yes; With S7 block Privacy
- Width
- 50 mm
- Height
- 290 mm
- Depth
- 219 mm
- Weight, approx.
- 900 g
Technical documents (1)
Key features
- 16 MB work memory: 8 MB code, 8 MB data
- 1st interface MPI/PROFIBUS DP 12 Mbit/s
- 2nd interface PROFIBUS DP
- 3rd interface: slot for a plug-in interface module (IF)
- Powered from the S7-400 system power supply
- Active Siemens product
About the Siemens 6ES7416-3XS07-0AB0
The Siemens 6ES7416-3XS07-0AB0 is the CPU 416-3 of the S7-400. Siemens's data sheet gives it 16 MB of work memory, split into 8 MB for code and 8 MB for data, a combined MPI/PROFIBUS DP interface at 12 Mbit/s, a PROFIBUS DP interface, and a third interface slot for a plug-in interface module. It is powered from the S7-400 rack's system power supply. Siemens lists it as an active product.
What is the 6ES7416-3XS07-0AB0 used for?
It runs large S7-400 stations with big programs and several PROFIBUS DP lines, in production lines and process plants.
Lifecycle and successor
Active.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the full order number and the firmware version on the CPU's front label; send a photo of it. S7-400 CPUs of the same type differ by order number in memory and interfaces, so quote against the exact number, and list any interface modules (IF) fitted.
Alternatives for 6ES7416-3XS07-0AB0
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| Siemens 6ES7412-2EK06-0AB0CPU 412-2 PN, 1 MB, MPI/DP and PROFINET | Siemens | PLC CPU | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7412-3HJ14-0AB0CPU 412-3H for S7-400H/F/FH, 768 KB, MPI/DP and 2 sync interfaces | Siemens | Redundant PLC CPU (H-CPU) | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7414-2XK05-0AB0CPU 414-2, 1 MB, MPI/DP and PROFIBUS DP | Siemens | PLC CPU | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7414-3XM07-0AB0CPU 414-3, 4 MB, MPI/DP, PROFIBUS DP and IF slot | Siemens | PLC CPU | Active | Same family | On Request | On request | View › |
| Siemens 6ES7416-2XP07-0AB0CPU 416-2, 8 MB, MPI/DP and PROFIBUS DP | Siemens | PLC CPU | Active | Same family | On Request | On request | View › |
| Siemens 6ES7417-4XT05-0AB0CPU 417-4, 30 MB, MPI, PROFIBUS DP and 2 IF slots | Siemens | PLC CPU | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7414-4HM14-0AB0CPU 414-4H for S7-400H/F/FH, 2.8 MB, MPI/DP, DP and 2 sync interfaces | Siemens | Redundant PLC CPU (H-CPU) | Discontinued | Same family | On Request | On request | View › |
| Siemens 6ES7416-3FS07-0AB0CPU 416F-3 PN/DP fail-safe, 16 MB, MPI/DP, PROFINET and IF slot | Siemens | Safety PLC CPU (F-CPU) | Active | Same family | On Request | On request | View › |
You may also be interested in

Siemens
Siemens 6ES7972-0BA12-0XA0
View ›
Siemens
Siemens 6ES7972-0BB12-0XA0
View ›
Siemens
Siemens 6ES7972-0BA42-0XA0
View ›
Siemens
Siemens 6ES7972-0BB42-0XA0
View ›
Siemens
Siemens 6ES7972-0BA52-0XA0
View ›
Siemens
Siemens 6ES7972-0BB52-0XA0
View ›
Siemens
Siemens 6ES7972-0BA61-0XA0
View ›
Siemens
Siemens 6ES7972-0BA70-0XA0
View ›
Siemens
Siemens 6GK1500-0FC10
View ›
Siemens
Siemens 6GK1901-1BB10-2AA0
View ›
Siemens
Siemens 6GK1901-1BB11-2AA0
View ›
Siemens
Siemens 6XV1830-0EH10
View ›