Siemens 6ES7414-2XK05-0AB0

CPU 414-2, 1 MB, MPI/DP and PROFIBUS DP

Request a quote
Siemens
Siemens 6ES7414-2XK05-0AB0 CPU 414-2, photo from Siemens data sheet 6ES7414-2XK05-0AB0

Image is for illustrative purposes only. Please refer to product description.

  • FedEx
  • DHL
  • UPS
Manufacturer
Siemens
Manufacturer part number
6ES7414-2XK05-0AB0
Technical datasheet
Data sheet

Specifications

AttributeValue
TypePLC CPU
Manufacturer lifecycleDiscontinued
Product type designationCPU 414-2
HW functional status03
Firmware versionV5.3
Product function / Isochronous modeYes; For PROFIBUS only
Engineering with / Programming packageSTEP 7 V5.3 SP2 or higher with HW update
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O byte15 µs
Supply voltage / Rated value (DC)Power supply via system power supply
Input current / from backplane bus 5 V DC, typ.0.9 A
Input current / from backplane bus 5 V DC, max.1.1 A
Input current / from backplane bus 24 V DC, max.300 mA; 150 mA per DP interface
Input current / from interface 5 V DC, max.90 mA; At each DP interface
Power loss, typ.4.5 W
Show all 323 specifications
Storage / Type of memoryRAM
Work memory / Integrated1 Mbyte
Work memory / integrated (for program)0.5 Mbyte
Work memory / integrated (for data)0.5 Mbyte
Work memory / expandableNo
Load memory / expandable FEPROMYes; with Memory Card (FLASH)
Load memory / expandable FEPROM, max.64 Mbyte
Load memory / integrated RAM, max.512 kbyte
Load memory / expandable RAMYes; with Memory Card (RAM)
Load memory / expandable RAM, max.64 Mbyte
Backup / presentYes
Backup / with batteryYes; all data
Backup / Without batteryNo
Backup battery / Backup current, typ.125 µA; up to 40 °C
Backup battery / Backup current, max.550 µA
Backup battery / Backup time, max.See reference manual, module data, Chapter 3.3
Backup battery / Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times / for bit operations, typ.45 ns
CPU processing times / for word operations, typ.45 ns
CPU processing times / for fixed point arithmetic, typ.45 ns
CPU processing times / for floating point arithmetic, typ.135 ns
DB / Number, max.6 000; Number range: 1 to 16000
DB / Size, max.64 kbyte
FB / Number, max.3 000; Number range: 0 to 7999
FB / Size, max.64 kbyte
FC / Number, max.3 000; Number range: 0 to 7999
FC / Size, max.64 kbyte
OB / Number, max.see instruction list
OB / Size, max.64 kbyte
OB / Number of free cycle OBs1; OB 1
OB / Number of time alarm OBs4; OB 10-13
OB / Number of delay alarm OBs4; OB 20-23
OB / Number of cyclic interrupt OBs4; OB 32-35 (shortest cycle that can be set = 500 µs)
OB / Number of process alarm OBs4; OB 40-43
OB / Number of DPV1 alarm OBs3; OB 55-57
OB / Number of isochronous mode OBs3; OB 61-63
OB / Number of multicomputing OBs1; OB 60
OB / Number of background OBs1; OB 90
OB / Number of startup OBs3; OB 100-102
OB / Number of asynchronous error OBs9; OB 80-88
OB / Number of synchronous error OBs2; OB 121, 122
Nesting depth / per priority class24
Nesting depth / additional within an error OB1
S7 counter / Number2 048
S7 counter / Retentivity / can be setYes
S7 counter / Retentivity / presetZ 0 to Z 7
S7 counter / Counting range / lower limit0
S7 counter / Counting range / upper limit999
IEC counter / presentYes
IEC counter / TypeSFB
IEC counter / NumberUnlimited (limited only by RAM capacity)
S7 timer / Number2 048
S7 timer / Retentivity / can be setYes
S7 timer / Retentivity / presetNo times retentive
S7 timer / Time range / lower limit10 ms
S7 timer / Time range / upper limit9 990 s
IEC timer / presentYes
IEC timer / TypeSFB
IEC timer / NumberUnlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.Total working and load memory (with backup battery)
Flag / Size, max.8 kbyte; Size of bit memory address area
Flag / Retentivity availableYes
Flag / Retentivity presetMB 0 to MB 15
Flag / Number of clock memories8; in 1 memory byte
Local data / adjustable, max.16 kbyte
Local data / preset8 kbyte
I/O address area / Inputs8 kbyte
I/O address area / Outputs8 kbyte
Process image / Inputs, adjustable8 kbyte
Process image / Outputs, adjustable8 kbyte
Process image / Inputs, default256 byte
Process image / Outputs, default256 byte
Process image / consistent data, max.244 byte
Process image / Access to consistent data in process imageYes
Subprocess images / Number of subprocess images, max.15
Digital channels / Inputs65 536
Digital channels / Inputs / of which central65 536
Digital channels / Outputs65 536
Digital channels / Outputs / of which central65 536
Analog channels / Inputs4 096
Analog channels / Inputs / of which central4 096
Analog channels / Outputs4 096
Analog channels / Outputs / of which central4 096
Hardware configuration / Integrated power supplyNo
Hardware configuration / Number of expansion units, max.21
Hardware configuration / connectable OPs31
Hardware configuration / MulticomputingYes; 4 CPUs max. (with UR1 or UR2)
Interface modules / Number of connectable IMs (total), max.6
Interface modules / Number of connectable IM 460s, max.6
Interface modules / Number of connectable IM 463s, max.4; IM 463-2
Number of DP masters / Integrated2
Number of DP masters / Via CP10; CP 443-5 Extended
Number of DP masters / via IM 4674
Number of DP masters / Mixed mode IM + CP permittedNo; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
Number of DP masters / via interface module0
Number of DP masters / Number of pluggable S5 modules (via adapter capsule in central device), max.6
Number of IO Controllers / Integrated0
Number of IO Controllers / Via CP4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended) / FMLimited by number of slots and number of connections
Number of operable FMs and CPs (recommended) / CP, PtPCP 440: Limited by number of slots; CP 441: limited by number of connections
Number of operable FMs and CPs (recommended) / PROFIBUS and Ethernet CPs14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum
Slots / required slots1
Clock / Hardware clock (real-time)Yes
Clock / retentive and synchronizableYes
Clock / Resolution1 ms
Clock / Deviation per day (buffered), max.1.7 s; Power off
Clock / Deviation per day (unbuffered), max.8.6 s; For power On
Operating hours counter / Number16
Operating hours counter / Number/Number range0 to 15
Operating hours counter / Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Operating hours counter / Granularity1 h
Operating hours counter / retentiveYes
Clock synchronization / supportedYes
Clock synchronization / to MPI, masterYes
Clock synchronization / on MPI, deviceYes
Clock synchronization / to DP, masterYes
Clock synchronization / on DP, deviceYes
Clock synchronization / in AS, masterYes
Clock synchronization / in AS, deviceYes
Clock synchronization / on Ethernet via NTPNo; Via CP
Time difference in system when synchronizing via / MPI, max.200 ms
Interfaces/bus type1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP
Number of RS 485 interfaces2; Combined MPI / PROFIBUS DP and PROFIBUS DP
Interfaces / Optical interfaceNo
1. Interface / Interface typeMPI/PROFIBUS DP
1. Interface / IsolatedYes
Interface types / RS 485Yes
Interface types / Output current of the interface, max.150 mA
Protocols / MPIYes
Protocols / PROFIBUS DP masterYes
Protocols / PROFIBUS DP deviceYes
MPI / Number of connections32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
MPI / Transmission rate, max.12 Mbit/s
MPI / Services / PG/OP communicationYes
MPI / Services / RoutingYes
MPI / Services / Global data communicationYes
MPI / Services / S7 basic communicationYes
MPI / Services / S7 communicationYes
MPI / Services / S7 communication, as clientYes
MPI / Services / S7 communication, as serverYes
1. Interface / PROFIBUS DP master / Number of connections, max.16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
PROFIBUS DP master / Transmission rate, max.12 Mbit/s
1. Interface / PROFIBUS DP master / max. number of DP devices32
PROFIBUS DP master / Services / PG/OP communicationYes
PROFIBUS DP master / Services / RoutingYes; S7 routing
PROFIBUS DP master / Services / Global data communicationNo
PROFIBUS DP master / Services / S7 basic communicationYes
PROFIBUS DP master / Services / S7 communicationYes
PROFIBUS DP master / Services / S7 communication, as clientYes
PROFIBUS DP master / Services / S7 communication, as serverYes
PROFIBUS DP master / Services / EquidistanceYes
PROFIBUS DP master / Services / Isochronous modeYes
PROFIBUS DP master / Services / SYNC/FREEZEYes
PROFIBUS DP master / Services / activation/deactivation of DP devicesYes
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)Yes
PROFIBUS DP master / Services / DPV1Yes
1. Interface / PROFIBUS DP master / Address area / Inputs, max.2 kbyte
1. Interface / PROFIBUS DP master / Address area / Outputs, max.2 kbyte
PROFIBUS DP master / User data per DP device / user data per DP device, max.244 byte
PROFIBUS DP master / User data per DP device / Inputs, max.244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.244 byte
PROFIBUS DP master / User data per DP device / Slots, max.244
PROFIBUS DP master / User data per DP device / per slot, max.128 byte
PROFIBUS DP device / Number of connections16
PROFIBUS DP device / Transmission rate, max.12 Mbit/s
PROFIBUS DP device / automatic baud rate searchNo
1. Interface / PROFIBUS DP device / Address area, max.32; Virtual slots
PROFIBUS DP device / User data per address area, max.32 byte
PROFIBUS DP device / User data per address area, max. / of which consistent, max.32 byte
PROFIBUS DP device / Services / PG/OP communicationYes; with interface active
1. Interface / PROFIBUS DP device / Services / RoutingYes; with interface active
PROFIBUS DP device / Services / Global data communicationNo
PROFIBUS DP device / Services / S7 basic communicationNo
PROFIBUS DP device / Services / S7 communicationYes
PROFIBUS DP device / Services / S7 communication, as clientYes
PROFIBUS DP device / Services / S7 communication, as serverYes
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)No
PROFIBUS DP device / Services / DPV1No
PROFIBUS DP device / Transfer memory / Inputs244 byte
PROFIBUS DP device / Transfer memory / Outputs244 byte
2. Interface / Interface typePROFIBUS DP
2. Interface / IsolatedYes
2. Interface / PROFIBUS DP master / Number of connections, max.16
2. Interface / PROFIBUS DP master / max. number of DP devices96
2. Interface / PROFIBUS DP master / Address area / Inputs, max.6 kbyte
2. Interface / PROFIBUS DP master / Address area / Outputs, max.6 kbyte
2. Interface / PROFIBUS DP device / Address area, max.32
2. Interface / PROFIBUS DP device / Services / RoutingYes
SIMATIC communication / S7 routingYes
Open IE communication / ISO-on-TCP (RFC1006)Via CP 443-1 and loadable FB
Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.1 452 bytes via CP 443-1 Adv.
Web server / supportedNo
Isochronous mode / EquidistanceYes
Number of DP masters with isochronous mode2
payload per isochronous device, max.244 byte
Isochronous mode / shortest clock pulse1 ms; 0.5 ms without use of SFC 126, 127
Isochronous mode / max. cycle32 ms
PG/OP communicationYes
PG/OP communication / Number of connectable OPs with message processing31; When using Alarm_S/SQ and Alarm_D/DQ
PG/OP communication / Number of connectable OPs without message processing31
Communication functions / Data record routingYes
Global data communication / supportedYes
Global data communication / Number of GD loops, max.8
Global data communication / Number of GD packets, transmitter, max.8
Global data communication / Number of GD packets, receiver, max.16
Global data communication / Size of GD packets, max.54 byte
Global data communication / Size of GD packet (of which consistent), max.1 variable
S7 basic communication / supportedYes
S7 basic communication / User data per job, max.76 byte
S7 basic communication / User data per job (of which consistent), max.1 variable
S7 communication / supportedYes
S7 communication / as serverYes
S7 communication / As clientYes
S7 communication / User data per job, max.64 kbyte
S7 communication / User data per job (of which consistent), max.462 byte; 1 variable
S5 compatible communication / supportedYes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
S5 compatible communication / User data per job, max.8 kbyte
S5 compatible communication / User data per job (of which consistent), max.240 byte
S5 compatible communication / Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.24/24
Standard communication (FMS) / supportedYes; Via CP and loadable FB
Number of connections / overall32
Number of connections / usable for PG communication31
Number of connections / usable for PG communication / reserved for PG communication1
Number of connections / usable for PG communication / adjustable for PG communication, max.0
Number of connections / usable for OP communication31
Number of connections / usable for OP communication / reserved for OP communication1
Number of connections / usable for OP communication / adjustable for OP communication, max.0
Number of connections / usable for S7 basic communication30
Number of connections / usable for S7 basic communication / reserved for S7 basic communication0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.0
Number of connections / usable for S7 communication30
Number of connections / usable for S7 communication / reserved for S7 communication0
Number of connections / usable for S7 communication / adjustable for S7 communication, max.0
Number of connections / usable for routing15
Number of connections / usable for routing / reserved for routing0
Number of connections / usable for routing / adjustable for routing, max.0
S7 message functions / Number of login stations for message functions, max.31; Max. 31 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm_8 and Alarm_P (e.g. WinCC)
S7 message functions / Symbol-related messagesYes
S7 message functions / SCAN procedureYes
S7 message functions / Program alarmsYes
S7 message functions / Process diagnostic messagesYes
S7 message functions / simultaneously active Alarm_S blocks, max.400; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
S7 message functions / Alarm 8-blocksYes
Alarm 8-blocks / Number of instances for alarm 8 and S7 communication blocks, max.1 200
Alarm 8-blocks / preset, max.300
S7 message functions / Process control messagesYes
S7 message functions / Number of archives that can log on simultaneously (SFB 37 AR_SEND)16
Number of messages / overall, max.512
Number of messages / in 100 ms grid, max.128
Number of messages / in 500 ms grid, max.256
Number of messages / in 1000 ms grid, max.512
Number of additional values / with 100 ms grid, max.1
Number of additional values / with 500, 1000 ms grid, max.10
Test commissioning functions / Status blockYes; Up to 2 simultaneously
Test commissioning functions / Single stepYes
Test commissioning functions / Number of breakpoints4
Status/control / Status/control variableYes; Up to 16 variable tables
Status/control / VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Status/control / Number of variables, max.70; Status/control
Forcing / ForcingYes
Forcing / Forcing, variablesInputs, outputs, bit memories, peripheral inputs, peripheral outputs
Forcing / Number of variables, max.256
Diagnostic buffer / presentYes
Diagnostic buffer / Number of entries, max.400
Diagnostic buffer / Number of entries, max. / can be setYes
Diagnostic buffer / Number of entries, max. / preset120
Service data / Can be read outYes
Standards, approvals, certificates / CE markYes
Standards, approvals, certificates / CSA approvalYes
Standards, approvals, certificates / UL approvalYes
Standards, approvals, certificates / cULusYes
Standards, approvals, certificates / FM approvalYes
Standards, approvals, certificates / RCM (formerly C-TICK)Yes
Standards, approvals, certificates / KC approvalYes
Standards, approvals, certificates / EAC (formerly Gost-R)Yes
Use in hazardous areas / ATEX markingATEX II 3G Ex nA IIC T4 Gc
Ambient temperature during operation / min.0 °C
Ambient temperature during operation / max.60 °C
Configuration software / STEP 7Yes
Programming / Command setsee instruction list
Programming / Nesting levels7
Programming / Access to consistent data in process imageYes
Programming / System functions (SFC)see instruction list
Programming / System function blocks (SFB)see instruction list
Programming / Programming language / LADYes
Programming / Programming language / FBDYes
Programming / Programming language / STLYes
Programming / Programming language / SCLYes
Programming / Programming language / CFCYes
Programming / Programming language / GRAPHYes
Programming / Programming language / HiGraph®Yes
Programming / Number of simultaneously active SFCs / DPSYC_FR2; SFC 11; per interface
Programming / Number of simultaneously active SFCs / D_ACT_DP8; SFC 12; per interface
Programming / Number of simultaneously active SFCs / RD_REC8; SFC 59; per interface
Programming / Number of simultaneously active SFCs / WR_REC8; SFC 58; per interface
Programming / Number of simultaneously active SFCs / WR_PARM8; SFC 55; per interface
Programming / Number of simultaneously active SFCs / PARM_MOD1; SFC 57; per interface
Programming / Number of simultaneously active SFCs / WR_DPARM2; SFC 56; per interface
Programming / Number of simultaneously active SFCs / DPNRM_DG8; SFC 13; per interface
Programming / Number of simultaneously active SFCs / RDSYSST8
Programming / Number of simultaneously active SFCs / DP_TOPOL1; SFC 103; per interface
Programming / Number of simultaneously active SFBs / RDREC8; SFB 52; per interface, but not more than 32 across all external interfaces
Programming / Number of simultaneously active SFBs / WRREC8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection / User program protection/password protectionYes
Width25 mm
Height290 mm
Depth219 mm
Weight, approx.700 g

Associated Products

ImageProductDescriptionStockViewAdd to RFQ
Siemens 6ES7412-2EK06-0AB0
6ES7412-2EK06-0AB0SiemensCPU 412-2 PN, 1 MB, MPI/DP and PROFINETIn stockView
Siemens 6ES7412-3HJ14-0AB0
6ES7412-3HJ14-0AB0SiemensCPU 412-3H for S7-400H/F/FH, 768 KB, MPI/DP and 2 sync interfacesIn stockView
Siemens 6ES7414-3XM07-0AB0
6ES7414-3XM07-0AB0SiemensCPU 414-3, 4 MB, MPI/DP, PROFIBUS DP and IF slotIn stockView
Siemens 6ES7416-2XP07-0AB0
6ES7416-2XP07-0AB0SiemensCPU 416-2, 8 MB, MPI/DP and PROFIBUS DPIn stockView
Siemens 6ES7416-3XS07-0AB0
6ES7416-3XS07-0AB0SiemensCPU 416-3, 16 MB, MPI/DP, PROFIBUS DP and IF slotIn stockView
Siemens 6ES7417-4XT05-0AB0
6ES7417-4XT05-0AB0SiemensCPU 417-4, 30 MB, MPI, PROFIBUS DP and 2 IF slotsIn stockView
Siemens 6ES7414-4HM14-0AB0
6ES7414-4HM14-0AB0SiemensCPU 414-4H for S7-400H/F/FH, 2.8 MB, MPI/DP, DP and 2 sync interfacesIn stockView
Siemens 6ES7416-3FS07-0AB0
6ES7416-3FS07-0AB0SiemensCPU 416F-3 PN/DP fail-safe, 16 MB, MPI/DP, PROFINET and IF slotIn stockView
Siemens 6ES7422-1BL00-0AA0
6ES7422-1BL00-0AA0SiemensSM 422 digital output, 32 DO, 24 V DC, 0.5 AIn stockView
Siemens 6ES7421-1BL01-0AA0
6ES7421-1BL01-0AA0SiemensSM 421 digital input, 32 DI, 24 V DCIn stockView
Siemens 6ES7421-7BH01-0AB0
6ES7421-7BH01-0AB0SiemensSM 421 digital input, 16 DI, 24 V DC, interrupt and diagnosticsIn stockView
Siemens 6ES7421-1EL00-0AA0
6ES7421-1EL00-0AA0SiemensSM 421 digital input, 32 DI, 120 V AC/DCIn stockView

Product Questions

Is the 6ES7414-2XK05-0AB0 discontinued?

Yes. Its manufacturer lifecycle status is Discontinued.

Can another Siemens SIMATIC S7-400 part replace it?

Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.

Do you ship worldwide?

Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.

Related Products and Accessories

  • Siemens

    6ES7421-1FH20-0AA0

    SM 421 digital input, 16 DI, 120/230 V AC/DC

    Same SIMATIC S7-400 system

    In stock

  • Siemens

    6ES7421-7DH00-0AB0

    SM 421 digital input, 16 DI, 24 to 60 V AC/DC, interrupt and diagnostics

    Same SIMATIC S7-400 system

    In stock

  • Siemens

    6ES7492-1CL00-0AA0

    Front connector for S7-400 signal modules, 48-pole, crimp contacts

    Same SIMATIC S7-400 system

    In stock

  • Siemens

    6ES7492-1AL00-0AA0

    Front connector for S7-400 signal modules, 48-pole, screw contacts

    Same SIMATIC S7-400 system

    In stock

Lifecycle Database

Siemens S7-400 Discontinued Parts List (2026)

Siemens status and dates for each S7-400 order number we track: I/O and function modules cancelled 1 October 2026, CPUs, Siemens source. Free CSV.

Open the database

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need a part? Send us the part number.

Added to cart