6ES7414-2XK05-0AB0

Siemens CPU 414-2, 1 MB, MPI/DP and PROFIBUS DP

Siemens
Siemens 6ES7414-2XK05-0AB0 CPU 414-2, photo from Siemens data sheet 6ES7414-2XK05-0AB0

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Siemens SIMATIC S7-400 CPU 414-2: central processing unit with 1 MB work memory (0.5 MB code, 0.5 MB data), an MPI/DP interface at 12 Mbit/s and a second PROFIBUS DP interface.

Manufacturer
Siemens
Manufacturer part no.
6ES7414-2XK05-0AB0
Type
PLC CPU
Lifecycle
Discontinued
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Siemens
Manufacturer part no.
6ES7414-2XK05-0AB0
Type
PLC CPU
Application
PLC controller
Used with
SIMATIC S7-400 rack (system power supply)
Product type designation
CPU 414-2
HW functional status
03
Firmware version
V5.3
Product function / Isochronous mode
Yes; For PROFIBUS only
Engineering with / Programming package
STEP 7 V5.3 SP2 or higher with HW update
CiR synchronization time, basic load
100 ms
CiR synchronization time, time per I/O byte
15 µs
Supply voltage / Rated value (DC)
Power supply via system power supply
Input current / from backplane bus 5 V DC, typ.
0.9 A
Input current / from backplane bus 5 V DC, max.
1.1 A
Input current / from backplane bus 24 V DC, max.
300 mA; 150 mA per DP interface
Input current / from interface 5 V DC, max.
90 mA; At each DP interface
Power loss, typ.
4.5 W
Storage / Type of memory
RAM
Work memory / Integrated
1 Mbyte
Work memory / integrated (for program)
0.5 Mbyte
Work memory / integrated (for data)
0.5 Mbyte
Work memory / expandable
No
Load memory / expandable FEPROM
Yes; with Memory Card (FLASH)
Load memory / expandable FEPROM, max.
64 Mbyte
Load memory / integrated RAM, max.
512 kbyte
Load memory / expandable RAM
Yes; with Memory Card (RAM)
Load memory / expandable RAM, max.
64 Mbyte
Backup / present
Yes
Backup / with battery
Yes; all data
Show all 326 specifications
Backup / Without battery
No
Backup battery / Backup current, typ.
125 µA; up to 40 °C
Backup battery / Backup current, max.
550 µA
Backup battery / Backup time, max.
See reference manual, module data, Chapter 3.3
Backup battery / Feeding of external backup voltage to CPU
5 V DC to 15 V DC
CPU processing times / for bit operations, typ.
45 ns
CPU processing times / for word operations, typ.
45 ns
CPU processing times / for fixed point arithmetic, typ.
45 ns
CPU processing times / for floating point arithmetic, typ.
135 ns
DB / Number, max.
6 000; Number range: 1 to 16000
DB / Size, max.
64 kbyte
FB / Number, max.
3 000; Number range: 0 to 7999
FB / Size, max.
64 kbyte
FC / Number, max.
3 000; Number range: 0 to 7999
FC / Size, max.
64 kbyte
OB / Number, max.
see instruction list
OB / Size, max.
64 kbyte
OB / Number of free cycle OBs
1; OB 1
OB / Number of time alarm OBs
4; OB 10-13
OB / Number of delay alarm OBs
4; OB 20-23
OB / Number of cyclic interrupt OBs
4; OB 32-35 (shortest cycle that can be set = 500 µs)
OB / Number of process alarm OBs
4; OB 40-43
OB / Number of DPV1 alarm OBs
3; OB 55-57
OB / Number of isochronous mode OBs
3; OB 61-63
OB / Number of multicomputing OBs
1; OB 60
OB / Number of background OBs
1; OB 90
OB / Number of startup OBs
3; OB 100-102
OB / Number of asynchronous error OBs
9; OB 80-88
OB / Number of synchronous error OBs
2; OB 121, 122
Nesting depth / per priority class
24
Nesting depth / additional within an error OB
1
S7 counter / Number
2 048
S7 counter / Retentivity / can be set
Yes
S7 counter / Retentivity / preset
Z 0 to Z 7
S7 counter / Counting range / lower limit
0
S7 counter / Counting range / upper limit
999
IEC counter / present
Yes
IEC counter / Type
SFB
IEC counter / Number
Unlimited (limited only by RAM capacity)
S7 timer / Number
2 048
S7 timer / Retentivity / can be set
Yes
S7 timer / Retentivity / preset
No times retentive
S7 timer / Time range / lower limit
10 ms
S7 timer / Time range / upper limit
9 990 s
IEC timer / present
Yes
IEC timer / Type
SFB
IEC timer / Number
Unlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.
Total working and load memory (with backup battery)
Flag / Size, max.
8 kbyte; Size of bit memory address area
Flag / Retentivity available
Yes
Flag / Retentivity preset
MB 0 to MB 15
Flag / Number of clock memories
8; in 1 memory byte
Local data / adjustable, max.
16 kbyte
Local data / preset
8 kbyte
I/O address area / Inputs
8 kbyte
I/O address area / Outputs
8 kbyte
Process image / Inputs, adjustable
8 kbyte
Process image / Outputs, adjustable
8 kbyte
Process image / Inputs, default
256 byte
Process image / Outputs, default
256 byte
Process image / consistent data, max.
244 byte
Process image / Access to consistent data in process image
Yes
Subprocess images / Number of subprocess images, max.
15
Digital channels / Inputs
65 536
Digital channels / Inputs / of which central
65 536
Digital channels / Outputs
65 536
Digital channels / Outputs / of which central
65 536
Analog channels / Inputs
4 096
Analog channels / Inputs / of which central
4 096
Analog channels / Outputs
4 096
Analog channels / Outputs / of which central
4 096
Hardware configuration / Integrated power supply
No
Hardware configuration / Number of expansion units, max.
21
Hardware configuration / connectable OPs
31
Hardware configuration / Multicomputing
Yes; 4 CPUs max. (with UR1 or UR2)
Interface modules / Number of connectable IMs (total), max.
6
Interface modules / Number of connectable IM 460s, max.
6
Interface modules / Number of connectable IM 463s, max.
4; IM 463-2
Number of DP masters / Integrated
2
Number of DP masters / Via CP
10; CP 443-5 Extended
Number of DP masters / via IM 467
4
Number of DP masters / Mixed mode IM + CP permitted
No; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
Number of DP masters / via interface module
0
Number of DP masters / Number of pluggable S5 modules (via adapter capsule in central device), max.
6
Number of IO Controllers / Integrated
0
Number of IO Controllers / Via CP
4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended) / FM
Limited by number of slots and number of connections
Number of operable FMs and CPs (recommended) / CP, PtP
CP 440: Limited by number of slots; CP 441: limited by number of connections
Number of operable FMs and CPs (recommended) / PROFIBUS and Ethernet CPs
14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum
Slots / required slots
1
Clock / Hardware clock (real-time)
Yes
Clock / retentive and synchronizable
Yes
Clock / Resolution
1 ms
Clock / Deviation per day (buffered), max.
1.7 s; Power off
Clock / Deviation per day (unbuffered), max.
8.6 s; For power On
Operating hours counter / Number
16
Operating hours counter / Number/Number range
0 to 15
Operating hours counter / Range of values
SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Operating hours counter / Granularity
1 h
Operating hours counter / retentive
Yes
Clock synchronization / supported
Yes
Clock synchronization / to MPI, master
Yes
Clock synchronization / on MPI, device
Yes
Clock synchronization / to DP, master
Yes
Clock synchronization / on DP, device
Yes
Clock synchronization / in AS, master
Yes
Clock synchronization / in AS, device
Yes
Clock synchronization / on Ethernet via NTP
No; Via CP
Time difference in system when synchronizing via / MPI, max.
200 ms
Interfaces/bus type
1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP
Number of RS 485 interfaces
2; Combined MPI / PROFIBUS DP and PROFIBUS DP
Interfaces / Optical interface
No
1. Interface / Interface type
MPI/PROFIBUS DP
1. Interface / Isolated
Yes
Interface types / RS 485
Yes
Interface types / Output current of the interface, max.
150 mA
Protocols / MPI
Yes
Protocols / PROFIBUS DP master
Yes
Protocols / PROFIBUS DP device
Yes
MPI / Number of connections
32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
MPI / Transmission rate, max.
12 Mbit/s
MPI / Services / PG/OP communication
Yes
MPI / Services / Routing
Yes
MPI / Services / Global data communication
Yes
MPI / Services / S7 basic communication
Yes
MPI / Services / S7 communication
Yes
MPI / Services / S7 communication, as client
Yes
MPI / Services / S7 communication, as server
Yes
1. Interface / PROFIBUS DP master / Number of connections, max.
16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
PROFIBUS DP master / Transmission rate, max.
12 Mbit/s
1. Interface / PROFIBUS DP master / max. number of DP devices
32
PROFIBUS DP master / Services / PG/OP communication
Yes
PROFIBUS DP master / Services / Routing
Yes; S7 routing
PROFIBUS DP master / Services / Global data communication
No
PROFIBUS DP master / Services / S7 basic communication
Yes
PROFIBUS DP master / Services / S7 communication
Yes
PROFIBUS DP master / Services / S7 communication, as client
Yes
PROFIBUS DP master / Services / S7 communication, as server
Yes
PROFIBUS DP master / Services / Equidistance
Yes
PROFIBUS DP master / Services / Isochronous mode
Yes
PROFIBUS DP master / Services / SYNC/FREEZE
Yes
PROFIBUS DP master / Services / activation/deactivation of DP devices
Yes
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)
Yes
PROFIBUS DP master / Services / DPV1
Yes
1. Interface / PROFIBUS DP master / Address area / Inputs, max.
2 kbyte
1. Interface / PROFIBUS DP master / Address area / Outputs, max.
2 kbyte
PROFIBUS DP master / User data per DP device / user data per DP device, max.
244 byte
PROFIBUS DP master / User data per DP device / Inputs, max.
244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.
244 byte
PROFIBUS DP master / User data per DP device / Slots, max.
244
PROFIBUS DP master / User data per DP device / per slot, max.
128 byte
PROFIBUS DP device / Number of connections
16
PROFIBUS DP device / Transmission rate, max.
12 Mbit/s
PROFIBUS DP device / automatic baud rate search
No
1. Interface / PROFIBUS DP device / Address area, max.
32; Virtual slots
PROFIBUS DP device / User data per address area, max.
32 byte
PROFIBUS DP device / User data per address area, max. / of which consistent, max.
32 byte
PROFIBUS DP device / Services / PG/OP communication
Yes; with interface active
1. Interface / PROFIBUS DP device / Services / Routing
Yes; with interface active
PROFIBUS DP device / Services / Global data communication
No
PROFIBUS DP device / Services / S7 basic communication
No
PROFIBUS DP device / Services / S7 communication
Yes
PROFIBUS DP device / Services / S7 communication, as client
Yes
PROFIBUS DP device / Services / S7 communication, as server
Yes
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)
No
PROFIBUS DP device / Services / DPV1
No
PROFIBUS DP device / Transfer memory / Inputs
244 byte
PROFIBUS DP device / Transfer memory / Outputs
244 byte
2. Interface / Interface type
PROFIBUS DP
2. Interface / Isolated
Yes
2. Interface / PROFIBUS DP master / Number of connections, max.
16
2. Interface / PROFIBUS DP master / max. number of DP devices
96
2. Interface / PROFIBUS DP master / Address area / Inputs, max.
6 kbyte
2. Interface / PROFIBUS DP master / Address area / Outputs, max.
6 kbyte
2. Interface / PROFIBUS DP device / Address area, max.
32
2. Interface / PROFIBUS DP device / Services / Routing
Yes
SIMATIC communication / S7 routing
Yes
Open IE communication / ISO-on-TCP (RFC1006)
Via CP 443-1 and loadable FB
Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.
1 452 bytes via CP 443-1 Adv.
Web server / supported
No
Isochronous mode / Equidistance
Yes
Number of DP masters with isochronous mode
2
payload per isochronous device, max.
244 byte
Isochronous mode / shortest clock pulse
1 ms; 0.5 ms without use of SFC 126, 127
Isochronous mode / max. cycle
32 ms
PG/OP communication
Yes
PG/OP communication / Number of connectable OPs with message processing
31; When using Alarm_S/SQ and Alarm_D/DQ
PG/OP communication / Number of connectable OPs without message processing
31
Communication functions / Data record routing
Yes
Global data communication / supported
Yes
Global data communication / Number of GD loops, max.
8
Global data communication / Number of GD packets, transmitter, max.
8
Global data communication / Number of GD packets, receiver, max.
16
Global data communication / Size of GD packets, max.
54 byte
Global data communication / Size of GD packet (of which consistent), max.
1 variable
S7 basic communication / supported
Yes
S7 basic communication / User data per job, max.
76 byte
S7 basic communication / User data per job (of which consistent), max.
1 variable
S7 communication / supported
Yes
S7 communication / as server
Yes
S7 communication / As client
Yes
S7 communication / User data per job, max.
64 kbyte
S7 communication / User data per job (of which consistent), max.
462 byte; 1 variable
S5 compatible communication / supported
Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
S5 compatible communication / User data per job, max.
8 kbyte
S5 compatible communication / User data per job (of which consistent), max.
240 byte
S5 compatible communication / Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.
24/24
Standard communication (FMS) / supported
Yes; Via CP and loadable FB
Number of connections / overall
32
Number of connections / usable for PG communication
31
Number of connections / usable for PG communication / reserved for PG communication
1
Number of connections / usable for PG communication / adjustable for PG communication, max.
0
Number of connections / usable for OP communication
31
Number of connections / usable for OP communication / reserved for OP communication
1
Number of connections / usable for OP communication / adjustable for OP communication, max.
0
Number of connections / usable for S7 basic communication
30
Number of connections / usable for S7 basic communication / reserved for S7 basic communication
0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.
0
Number of connections / usable for S7 communication
30
Number of connections / usable for S7 communication / reserved for S7 communication
0
Number of connections / usable for S7 communication / adjustable for S7 communication, max.
0
Number of connections / usable for routing
15
Number of connections / usable for routing / reserved for routing
0
Number of connections / usable for routing / adjustable for routing, max.
0
S7 message functions / Number of login stations for message functions, max.
31; Max. 31 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm_8 and Alarm_P (e.g. WinCC)
S7 message functions / Symbol-related messages
Yes
S7 message functions / SCAN procedure
Yes
S7 message functions / Program alarms
Yes
S7 message functions / Process diagnostic messages
Yes
S7 message functions / simultaneously active Alarm_S blocks, max.
400; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
S7 message functions / Alarm 8-blocks
Yes
Alarm 8-blocks / Number of instances for alarm 8 and S7 communication blocks, max.
1 200
Alarm 8-blocks / preset, max.
300
S7 message functions / Process control messages
Yes
S7 message functions / Number of archives that can log on simultaneously (SFB 37 AR_SEND)
16
Number of messages / overall, max.
512
Number of messages / in 100 ms grid, max.
128
Number of messages / in 500 ms grid, max.
256
Number of messages / in 1000 ms grid, max.
512
Number of additional values / with 100 ms grid, max.
1
Number of additional values / with 500, 1000 ms grid, max.
10
Test commissioning functions / Status block
Yes; Up to 2 simultaneously
Test commissioning functions / Single step
Yes
Test commissioning functions / Number of breakpoints
4
Status/control / Status/control variable
Yes; Up to 16 variable tables
Status/control / Variables
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Status/control / Number of variables, max.
70; Status/control
Forcing / Forcing
Yes
Forcing / Forcing, variables
Inputs, outputs, bit memories, peripheral inputs, peripheral outputs
Forcing / Number of variables, max.
256
Diagnostic buffer / present
Yes
Diagnostic buffer / Number of entries, max.
400
Diagnostic buffer / Number of entries, max. / can be set
Yes
Diagnostic buffer / Number of entries, max. / preset
120
Service data / Can be read out
Yes
Standards, approvals, certificates / CE mark
Yes
Standards, approvals, certificates / CSA approval
Yes
Standards, approvals, certificates / UL approval
Yes
Standards, approvals, certificates / cULus
Yes
Standards, approvals, certificates / FM approval
Yes
Standards, approvals, certificates / RCM (formerly C-TICK)
Yes
Standards, approvals, certificates / KC approval
Yes
Standards, approvals, certificates / EAC (formerly Gost-R)
Yes
Use in hazardous areas / ATEX marking
ATEX II 3G Ex nA IIC T4 Gc
Ambient temperature during operation / min.
0 °C
Ambient temperature during operation / max.
60 °C
Configuration software / STEP 7
Yes
Programming / Command set
see instruction list
Programming / Nesting levels
7
Programming / Access to consistent data in process image
Yes
Programming / System functions (SFC)
see instruction list
Programming / System function blocks (SFB)
see instruction list
Programming / Programming language / LAD
Yes
Programming / Programming language / FBD
Yes
Programming / Programming language / STL
Yes
Programming / Programming language / SCL
Yes
Programming / Programming language / CFC
Yes
Programming / Programming language / GRAPH
Yes
Programming / Programming language / HiGraph®
Yes
Programming / Number of simultaneously active SFCs / DPSYC_FR
2; SFC 11; per interface
Programming / Number of simultaneously active SFCs / D_ACT_DP
8; SFC 12; per interface
Programming / Number of simultaneously active SFCs / RD_REC
8; SFC 59; per interface
Programming / Number of simultaneously active SFCs / WR_REC
8; SFC 58; per interface
Programming / Number of simultaneously active SFCs / WR_PARM
8; SFC 55; per interface
Programming / Number of simultaneously active SFCs / PARM_MOD
1; SFC 57; per interface
Programming / Number of simultaneously active SFCs / WR_DPARM
2; SFC 56; per interface
Programming / Number of simultaneously active SFCs / DPNRM_DG
8; SFC 13; per interface
Programming / Number of simultaneously active SFCs / RDSYSST
8
Programming / Number of simultaneously active SFCs / DP_TOPOL
1; SFC 103; per interface
Programming / Number of simultaneously active SFBs / RDREC
8; SFB 52; per interface, but not more than 32 across all external interfaces
Programming / Number of simultaneously active SFBs / WRREC
8; SFB 53; per interface, but not more than 32 across all external interfaces
Know-how protection / User program protection/password protection
Yes
Width
25 mm
Height
290 mm
Depth
219 mm
Weight, approx.
700 g

Technical documents (1)

Key features

  • 1 MB work memory: 0.5 MB code, 0.5 MB data
  • 1st interface MPI/PROFIBUS DP 12 Mbit/s
  • 2nd interface PROFIBUS DP
  • Isochronous mode on PROFIBUS
  • Powered from the S7-400 system power supply

About the Siemens 6ES7414-2XK05-0AB0

The Siemens 6ES7414-2XK05-0AB0 is the CPU 414-2 of the S7-400. Siemens's data sheet gives it 1 MB of work memory, split into 0.5 MB for code and 0.5 MB for data, a combined MPI/PROFIBUS DP interface at 12 Mbit/s and a second PROFIBUS DP interface. It is powered from the S7-400 rack's system power supply.

What is the 6ES7414-2XK05-0AB0 used for?

It runs mid-sized S7-400 stations with I/O in the rack and distributed I/O on two PROFIBUS DP lines, common in production lines and plant sections built on PROFIBUS.

Lifecycle and successor

Discontinued.

Before you order

What to photograph or confirm so the right unit is quoted.

Check the full order number and the firmware version on the CPU's front label; send a photo of it. S7-400 CPUs of the same type differ by order number in memory and interfaces, so quote against the exact number, and list any interface modules (IF) fitted.

Alternatives for 6ES7414-2XK05-0AB0

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
Siemens 6ES7412-2EK06-0AB0CPU 412-2 PN, 1 MB, MPI/DP and PROFINETSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7412-3HJ14-0AB0CPU 412-3H for S7-400H/F/FH, 768 KB, MPI/DP and 2 sync interfacesSiemensRedundant PLC CPU (H-CPU)DiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7414-3XM07-0AB0CPU 414-3, 4 MB, MPI/DP, PROFIBUS DP and IF slotSiemensPLC CPUActiveSame familyOn RequestOn requestView ›
Siemens 6ES7416-2XP07-0AB0CPU 416-2, 8 MB, MPI/DP and PROFIBUS DPSiemensPLC CPUActiveSame familyOn RequestOn requestView ›
Siemens 6ES7416-3XS07-0AB0CPU 416-3, 16 MB, MPI/DP, PROFIBUS DP and IF slotSiemensPLC CPUActiveSame familyOn RequestOn requestView ›
Siemens 6ES7417-4XT05-0AB0CPU 417-4, 30 MB, MPI, PROFIBUS DP and 2 IF slotsSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7414-4HM14-0AB0CPU 414-4H for S7-400H/F/FH, 2.8 MB, MPI/DP, DP and 2 sync interfacesSiemensRedundant PLC CPU (H-CPU)DiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7416-3FS07-0AB0CPU 416F-3 PN/DP fail-safe, 16 MB, MPI/DP, PROFINET and IF slotSiemensSafety PLC CPU (F-CPU)ActiveSame familyOn RequestOn requestView ›