Image is for illustrative purposes only. Please refer to product description.
Delivery options
Siemens SIMATIC S7-400 FM 455 C controller module: 16 continuous control channels with 16 analog inputs (8 with Pt100), 16 digital inputs and 16 analog outputs, configuration package on CD.
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7455-0VS00-0AE0
- Product family
- SIMATIC S7-400 PLC CPUs, I/O and Function Modules
- Type
- Controller module
- Lifecycle
- Discontinued
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7455-0VS00-0AE0
- Type
- Controller module
- Application
- Controller module
- Used with
- SIMATIC S7-400 rack
- Load voltage L+ / Rated value (DC)
- 24 V
- Load voltage L+ / permissible range, lower limit (DC)
- 20.4 V
- Load voltage L+ / permissible range, upper limit (DC)
- 28.8 V
- Input current / from load voltage L+ (without load), max.
- 440 mA; typ. 370 mA
- Power loss, typ.
- 12 W
- Power loss, max.
- 17.3 W
- Number of digital inputs
- 16
- Digital inputs / Input characteristic curve in accordance with IEC 61131, type 2
- Yes
- Input voltage / Rated value (DC)
- 24 V
- Input voltage / for signal "0"
- -3 to +5V
- Input voltage / for signal "1"
- 13 to 30V
- Input current / for signal "1", typ.
- 7 mA
- Digital inputs / Cable length / shielded, max.
- 1 000 m
- Cable length / unshielded, max.
- 600 m
- Number of analog inputs
- 16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
- Analog inputs / permissible input voltage for voltage input (destruction limit), max.
- 20 V
- Analog inputs / permissible input current for current input (destruction limit), max.
- 40 mA
- Input ranges / Voltage
- Yes
- Input ranges / Current
- Yes
- Input ranges / Thermocouple
- Yes
- Input ranges / Resistance thermometer
- Yes
- Input ranges (rated values), voltages / 0 to +10 V
- Yes
- Input ranges (rated values), voltages / 0 to +10 V / Input resistance (0 to 10 V)
- 100 kΩ
- Input ranges (rated values), voltages / -1.75 V to +11.75 V
- Yes
- Input ranges (rated values), voltages / -1.75 V to +11.75 V / Input resistance (-1.75 V to +11.75 V)
- 100 kΩ
Show all 103 specificationsShow fewer
- Input ranges (rated values), voltages / -80 mV to +80 mV
- Yes
- Input ranges (rated values), voltages / -80 mV to +80 mV / Input resistance (-80 mV to +80 mV)
- 10 MΩ
- Input ranges (rated values), currents / 0 to 20 mA
- Yes
- Input ranges (rated values), currents / 0 to 20 mA / Input resistance (0 to 20 mA)
- 50 Ω
- Input ranges (rated values), currents / 0 to 23.5 mA
- Yes
- Input ranges (rated values), currents / 0 to 23.5 mA / Input resistance (0 to 23.5 mA)
- 50 Ω
- Input ranges (rated values), currents / -3.5 mA to +23.5 mA
- Yes
- Input ranges (rated values), currents / -3.5 mA to +23.5 mA / Input resistance (-3.5 mA to +23.5 mA)
- 50 Ω
- Input ranges (rated values), currents / 4 mA to 20 mA
- Yes
- Input ranges (rated values), currents / 4 mA to 20 mA / Input resistance (4 mA to 20 mA)
- 50 Ω
- Input ranges (rated values), thermocouples / Type B
- Yes
- Input ranges (rated values), thermocouples / Type B / Input resistance (Type B)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type J
- Yes
- Input ranges (rated values), thermocouples / Type J / Input resistance (type J)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type K
- Yes
- Input ranges (rated values), thermocouples / Type K / Input resistance (Type K)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type R
- Yes
- Input ranges (rated values), thermocouples / Type R / Input resistance (Type R)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type S
- Yes
- Input ranges (rated values), thermocouples / Type S / Input resistance (Type S)
- 10 MΩ
- Input ranges (rated values), resistance thermometer / Pt 100
- Yes
- Input ranges (rated values), resistance thermometer / Pt 100 / Input resistance (Pt 100)
- 10 MΩ
- Thermocouple (TC) / Temperature compensation / internal temperature compensation
- Yes; Parameterizable
- Thermocouple (TC) / Temperature compensation / external temperature compensation with Pt100
- Yes; Parameterizable
- Characteristic linearization / Parameterizable
- Yes
- Characteristic linearization / Parameterizable / for thermocouples
- Type B, J, K, R, S
- Characteristic linearization / Parameterizable / for resistance thermometer
- Pt100 (standard)
- Analog inputs / Cable length / shielded, max.
- 200 m; 50 m at 80 mV and thermocouples
- Number of analog outputs
- 16
- Analog outputs / Voltage output, short-circuit protection
- Yes
- Analog outputs / Voltage output, short-circuit current, max.
- 25 mA
- Analog outputs / Current output, no-load voltage, max.
- 18 V
- Output ranges, voltage / 0 to 10 V
- Yes
- Output ranges, voltage / -10 V to +10 V
- Yes
- Output ranges, current / 0 to 20 mA
- Yes
- Output ranges, current / -20 mA to +20 mA
- Yes
- Output ranges, current / 4 mA to 20 mA
- Yes
- Connection of actuators / for voltage output two-wire connection
- Yes
- Connection of actuators / for current output two-wire connection
- Yes
- Load impedance (in rated range of output) / with voltage outputs, min.
- 1 kΩ
- Load impedance (in rated range of output) / with voltage outputs, capacitive load, max.
- 1 µF
- Load impedance (in rated range of output) / with current outputs, max.
- 500 Ω
- Load impedance (in rated range of output) / with current outputs, inductive load, max.
- 1 mH
- Analog outputs / Cable length / shielded, max.
- 200 m; 50 m at 80 mV and thermocouples
- Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.
- 14 bit; 12 bit or 14 bit, parameterizable
- Integration and conversion time/resolution per channel / Conversion time (per channel)
- 16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 Hz and 60 Hz
- Settling time / for resistive load
- 0.1 ms
- Settling time / for capacitive load
- 3.3 ms
- Settling time / for inductive load
- 0.5 ms
- Connection of signal encoders / for voltage measurement
- Yes
- Connection of signal encoders / for current measurement as 4-wire transducer
- Yes
- Connectable encoders / 2-wire sensor
- Yes
- Connectable encoders / 2-wire sensor / permissible quiescent current (2-wire sensor), max.
- 1.5 mA
- Operational error limit in overall temperature range / Voltage, relative to input range, (+/-)
- ±0.6 to ±1%
- Operational error limit in overall temperature range / Current, relative to input range, (+/-)
- ±0.6 to ±1%
- Operational error limit in overall temperature range / Resistance thermometer, relative to input range, (+/-)
- ±0.6 to ±1%
- Operational error limit in overall temperature range / Voltage, relative to output range, (+/-)
- 0.5 %
- Operational error limit in overall temperature range / Current, relative to output range, (+/-)
- 0.6 %
- Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-)
- ±0.4 to ±0.6 %
- Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-)
- ±0.4 to ±0.6 %
- Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-)
- ±0.4 to ±0.6 %
- Basic error limit (operational limit at 25 °C) / Voltage, relative to output range, (+/-)
- 0.4 %
- Basic error limit (operational limit at 25 °C) / Current, relative to output range, (+/-)
- 0.5 %
- Interrupts/diagnostics/status information / Substitute values connectable
- Yes; Parameterizable
- Control technology / Number of closed-loop controllers
- 16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
- Potential separation controller / between the channels
- No
- Potential separation controller / between the channels and backplane bus
- Yes; Optocoupler
- Isolation tested with
- 500 V DC
- required front connector
- 2x 48-pin
- Width
- 50 mm
- Height
- 290 mm
- Depth
- 210 mm
- Weight, approx.
- 1 400 g
Technical documents (1)
Key features
- 16 continuous control channels with analog outputs
- 16 analog inputs (8 with Pt100 or 4-wire connection); thermocouple types B, J, K, R and S
- 16 digital inputs, 24 V DC
- 16 analog outputs: 0 to 10 V, ±10 V, 0/4 to 20 mA, ±20 mA
- Discontinued by Siemens on 1 October 2026
About the Siemens 6ES7455-0VS00-0AE0
The Siemens 6ES7455-0VS00-0AE0 is the FM 455 C, the continuous-output version of the S7-400 FM 455 controller module; the FM 455 S (6ES7455-1VS00-0AE0) has step and pulse outputs instead. Siemens's data sheet gives 16 control channels, 16 analog inputs (8 with Pt100), thermocouple types B, J, K, R and S, 16 digital inputs, 16 analog outputs and 12 W typical power loss. SiePortal shows its phase-out announced on 1 October 2025 and its product cancellation on 1 October 2026.
What is the 6ES7455-0VS00-0AE0 used for?
It runs up to 16 closed control loops, such as temperature, pressure or flow, for an S7-400 CPU.
Lifecycle and successor
Discontinued.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the order number: 0VS00 is the continuous FM 455 C, 1VS00 the step and pulse FM 455 S.
Other parts in the Siemens SIMATIC S7-400 family
Listed for reference. They differ from the 6ES7455-0VS00-0AE0 in rating, supply, interface or function and are not interchangeable with it unless Siemens says so. Match the part number on your unit.
| Product | Type | Lifecycle | Qty Available | Price | Action |
|---|---|---|---|---|---|
| Siemens 6ES7431-7QH00-0AB0SM 431 analog input, 16 AI, 16 bit, universal, diagnostics | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7431-7KF00-0AB0SM 431 analog input, 8 AI, 16 bit, U/I/thermocouple | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7431-7KF10-0AB0SM 431 analog input, 8 AI, 16 bit, resistance thermometers | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7431-0HH00-0AB0SM 431 analog input, 16 AI, 13 bit, non-isolated | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7432-1HF00-0AB0SM 432 analog output, 8 AO, 13 bit, U/I | Analog output module | Discontinued | On Request | On request | View |
| Siemens 6ES7450-1AP01-0AE0FM 450-1 counter module, 2 channels, up to 500 kHz | Counter module | Discontinued | On Request | On request | View |
| Siemens 6ES7451-3AL00-0AE0FM 451 positioning module, 3 channels, rapid/creep traverse | Positioning module | Discontinued | On Request | On request | View |
| Siemens 6ES7452-1AH00-0AE0FM 452 electronic cam controller, 16 cam tracks | Cam controller module | Discontinued | On Request | On request | View |
| Siemens 6ES7455-1VS00-0AE0FM 455 S controller module, 16 step and pulse control channels | Controller module | Discontinued | On Request | On request | View |
| Siemens 6ES7492-1AL00-0AA0Front connector for S7-400 signal modules, 48-pole, screw contacts | Front connector | Discontinued | On Request | On request | View |
| Siemens 6ES7492-1BL00-0AA0Front connector for S7-400 signal modules, 48-pole, spring-loaded contacts | Front connector | Discontinued | On Request | On request | View |
| Siemens 6ES7492-1CL00-0AA0Front connector for S7-400 signal modules, 48-pole, crimp contacts | Front connector | Discontinued | On Request | On request | View |
You may also be interested in

Siemens
Siemens 6ES7331-7NF10-0AB0
ViewSiemens
Siemens 6ES7331-7HF01-0AB0
View
Siemens
Siemens 6ES7331-7PF11-0AB0
ViewSiemens
Siemens 6ES7332-5HB01-0AB0
View
Siemens
Siemens 6ES7332-7ND02-0AB0
View
Siemens
Siemens 6ES7338-4BC01-0AB0
View
Siemens
Siemens 6ES7341-1CH02-0AE0
View
Siemens
Siemens 6ES7341-1AH02-0AE0
View
Siemens
Siemens 6GK7343-2AH11-0XA0
View
Siemens
Siemens 6GK7343-1GX31-0XE0
View
Siemens
Siemens 6ES7351-1AH02-0AE0
View
Siemens
Siemens 6ES7352-1AH02-0AE0
View
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.