Siemens SIMATIC S7-400 FM 455 S controller module: 16 step and pulse control channels with 16 analog inputs (8 with Pt100), 16 digital inputs and 32 digital outputs, configuration package on CD.
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7455-1VS00-0AE0
- Product family
- SIMATIC S7-400 PLC CPUs, I/O and Function Modules
- Type
- Controller module
- Lifecycle
- Discontinued
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7455-1VS00-0AE0
- Type
- Controller module
- Application
- Controller module
- Used with
- SIMATIC S7-400 rack
- Load voltage L+ / Rated value (DC)
- 24 V
- Load voltage L+ / permissible range, lower limit (DC)
- 20.4 V
- Load voltage L+ / permissible range, upper limit (DC)
- 28.8 V
- Input current / from load voltage L+ (without load), max.
- 400 mA; typ. 330 mA
- Power loss, typ.
- 10.7 W
- Power loss, max.
- 16.2 W
- Number of digital inputs
- 16
- Digital inputs / Input characteristic curve in accordance with IEC 61131, type 2
- Yes
- Input voltage / Rated value (DC)
- 24 V
- Input voltage / for signal "0"
- -3 to +5V
- Input voltage / for signal "1"
- 13 to 30V
- Input current / for signal "1", typ.
- 7 mA
- Digital inputs / Cable length / shielded, max.
- 1 000 m
- Cable length / unshielded, max.
- 600 m
- Number of digital outputs
- 32
- Digital outputs / Short-circuit protection
- Yes; Electronic
- Digital outputs / Limitation of inductive shutdown voltage to
- L+ (-1.5 V)
- Controlling a digital input
- Yes
- Switching capacity of the outputs / on lamp load, max.
- 5 W
- Load resistance range / lower limit
- 240 Ω
- Load resistance range / upper limit
- 4 kΩ
- Output voltage / for signal "1", min.
- L+ (-2.5 V)
- Output current / for signal "1" rated value
- 0.1 A
- Output current / for signal "1" permissible range for 0 to 60 °C, min.
- 5 mA
- Output current / for signal "1" permissible range for 0 to 60 °C, max.
- 150 mA
Show all 97 specificationsShow fewer
- Output current / for signal "0" residual current, max.
- 0.5 mA
- Parallel switching of two outputs / for logic links
- Yes
- Switching frequency / with resistive load, max.
- 100 Hz
- Switching frequency / with inductive load, max.
- 0.5 Hz
- Switching frequency / on lamp load, max.
- 100 Hz
- Digital outputs / Cable length / shielded, max.
- 1 000 m
- Number of analog inputs
- 16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
- Analog inputs / permissible input voltage for voltage input (destruction limit), max.
- 20 V
- Analog inputs / permissible input current for current input (destruction limit), max.
- 40 mA
- Input ranges / Voltage
- Yes
- Input ranges / Current
- Yes
- Input ranges / Thermocouple
- Yes
- Input ranges / Resistance thermometer
- Yes
- Input ranges (rated values), voltages / 0 to +10 V
- Yes
- Input ranges (rated values), voltages / 0 to +10 V / Input resistance (0 to 10 V)
- 100 kΩ
- Input ranges (rated values), voltages / -1.75 V to +11.75 V
- Yes
- Input ranges (rated values), voltages / -1.75 V to +11.75 V / Input resistance (-1.75 V to +11.75 V)
- 100 kΩ
- Input ranges (rated values), voltages / -80 mV to +80 mV
- Yes
- Input ranges (rated values), voltages / -80 mV to +80 mV / Input resistance (-80 mV to +80 mV)
- 10 MΩ
- Input ranges (rated values), currents / 0 to 20 mA
- Yes
- Input ranges (rated values), currents / 0 to 20 mA / Input resistance (0 to 20 mA)
- 50 Ω
- Input ranges (rated values), currents / 0 to 23.5 mA
- Yes
- Input ranges (rated values), currents / 0 to 23.5 mA / Input resistance (0 to 23.5 mA)
- 50 Ω
- Input ranges (rated values), currents / -3.5 mA to +23.5 mA
- Yes
- Input ranges (rated values), currents / -3.5 mA to +23.5 mA / Input resistance (-3.5 mA to +23.5 mA)
- 50 Ω
- Input ranges (rated values), currents / 4 mA to 20 mA
- Yes
- Input ranges (rated values), currents / 4 mA to 20 mA / Input resistance (4 mA to 20 mA)
- 50 Ω
- Input ranges (rated values), thermocouples / Type B
- Yes
- Input ranges (rated values), thermocouples / Type B / Input resistance (Type B)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type J
- Yes
- Input ranges (rated values), thermocouples / Type J / Input resistance (type J)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type K
- Yes
- Input ranges (rated values), thermocouples / Type K / Input resistance (Type K)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type R
- Yes
- Input ranges (rated values), thermocouples / Type R / Input resistance (Type R)
- 10 MΩ
- Input ranges (rated values), thermocouples / Type S
- Yes
- Input ranges (rated values), thermocouples / Type S / Input resistance (Type S)
- 10 MΩ
- Input ranges (rated values), resistance thermometer / Pt 100
- Yes
- Input ranges (rated values), resistance thermometer / Pt 100 / Input resistance (Pt 100)
- 10 MΩ
- Thermocouple (TC) / Temperature compensation / internal temperature compensation
- Yes; Parameterizable
- Thermocouple (TC) / Temperature compensation / external temperature compensation with Pt100
- Yes; Parameterizable
- Characteristic linearization / Parameterizable
- Yes
- Characteristic linearization / Parameterizable / for thermocouples
- Type B, J, K, R, S
- Characteristic linearization / Parameterizable / for resistance thermometer
- Pt100 (standard)
- Analog inputs / Cable length / shielded, max.
- 200 m; 50 m at 80 mV and thermocouples
- Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.
- 14 bit; 12 bit or 14 bit, parameterizable
- Integration and conversion time/resolution per channel / Conversion time (per channel)
- 16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 Hz and 60 Hz
- Connection of signal encoders / for voltage measurement
- Yes
- Connection of signal encoders / for current measurement as 4-wire transducer
- Yes
- Connectable encoders / 2-wire sensor
- Yes
- Connectable encoders / 2-wire sensor / permissible quiescent current (2-wire sensor), max.
- 1.5 mA
- Operational error limit in overall temperature range / Voltage, relative to input range, (+/-)
- ±0.6 to ±1%
- Operational error limit in overall temperature range / Current, relative to input range, (+/-)
- ±0.6 to ±1%
- Operational error limit in overall temperature range / Resistance thermometer, relative to input range, (+/-)
- ±0.6 to ±1%
- Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-)
- ±0.4 to ±0.6 %
- Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-)
- ±0.4 to ±0.6 %
- Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-)
- ±0.4 to ±0.6 %
- Interrupts/diagnostics/status information / Substitute values connectable
- Yes; Parameterizable
- Control technology / Number of closed-loop controllers
- 16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
- Potential separation controller / between the channels
- No
- Potential separation controller / between the channels and backplane bus
- Yes; Optocoupler
- Isolation tested with
- 500 V DC
- required front connector
- 2x 48-pin
- Width
- 50 mm
- Height
- 290 mm
- Depth
- 210 mm
- Weight, approx.
- 1 400 g
Technical documents (1)
Key features
- 16 step and pulse control channels with digital outputs
- 16 analog inputs (8 with Pt100 or 4-wire connection)
- 16 digital inputs, 24 V DC
- 32 digital outputs, 0.1 A each, short-circuit protected
- Discontinued by Siemens on 1 October 2026
About the Siemens 6ES7455-1VS00-0AE0
The Siemens 6ES7455-1VS00-0AE0 is the FM 455 S, the step and pulse version of the S7-400 FM 455 controller module; the FM 455 C (6ES7455-0VS00-0AE0) has 16 analog outputs instead of its 32 digital ones. Siemens's data sheet gives 16 control channels, 16 analog inputs (8 with Pt100), 16 digital inputs, 32 digital outputs at 0.1 A, a 50 mm wide housing and 10.7 W typical power loss. SiePortal shows its phase-out announced on 1 October 2025 and its product cancellation on 1 October 2026.
What is the 6ES7455-1VS00-0AE0 used for?
It runs up to 16 control loops that act through step or pulse outputs, for an S7-400 CPU.
Lifecycle and successor
Discontinued.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the order number: 1VS00 is the step and pulse FM 455 S, 0VS00 the continuous FM 455 C.
Other parts in the Siemens SIMATIC S7-400 family
Listed for reference. They differ from the 6ES7455-1VS00-0AE0 in rating, supply, interface or function and are not interchangeable with it unless Siemens says so. Match the part number on your unit.
| Product | Type | Lifecycle | Qty Available | Price | Action |
|---|---|---|---|---|---|
| Siemens 6ES7431-7QH00-0AB0SM 431 analog input, 16 AI, 16 bit, universal, diagnostics | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7431-7KF00-0AB0SM 431 analog input, 8 AI, 16 bit, U/I/thermocouple | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7431-7KF10-0AB0SM 431 analog input, 8 AI, 16 bit, resistance thermometers | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7431-0HH00-0AB0SM 431 analog input, 16 AI, 13 bit, non-isolated | Analog input module | Discontinued | On Request | On request | View |
| Siemens 6ES7432-1HF00-0AB0SM 432 analog output, 8 AO, 13 bit, U/I | Analog output module | Discontinued | On Request | On request | View |
| Siemens 6ES7450-1AP01-0AE0FM 450-1 counter module, 2 channels, up to 500 kHz | Counter module | Discontinued | On Request | On request | View |
| Siemens 6ES7451-3AL00-0AE0FM 451 positioning module, 3 channels, rapid/creep traverse | Positioning module | Discontinued | On Request | On request | View |
| Siemens 6ES7452-1AH00-0AE0FM 452 electronic cam controller, 16 cam tracks | Cam controller module | Discontinued | On Request | On request | View |
| Siemens 6ES7455-0VS00-0AE0FM 455 C controller module, 16 continuous control channels | Controller module | Discontinued | On Request | On request | View |
| Siemens 6ES7492-1AL00-0AA0Front connector for S7-400 signal modules, 48-pole, screw contacts | Front connector | Discontinued | On Request | On request | View |
| Siemens 6ES7492-1BL00-0AA0Front connector for S7-400 signal modules, 48-pole, spring-loaded contacts | Front connector | Discontinued | On Request | On request | View |
| Siemens 6ES7492-1CL00-0AA0Front connector for S7-400 signal modules, 48-pole, crimp contacts | Front connector | Discontinued | On Request | On request | View |
You may also be interested in

Siemens
Siemens 6ES7323-1BL00-0AA0
View
Siemens
Siemens 6ES7392-1AM00-0AA0
View
Siemens
Siemens 6ES7392-1AJ00-0AA0
View
Siemens
Siemens 6ES7953-8LJ31-0AA0
View
Siemens
Siemens 6ES7953-8LL31-0AA0
View
Siemens
Siemens 6ES7312-1AE14-0AB0
View
Siemens
Siemens 6ES7314-1AG14-0AB0
View
Siemens
Siemens 6ES7313-6CG04-0AB0
View
Siemens
Siemens 6ES7314-6CH04-0AB0
View
Siemens
Siemens 6ES7317-2AK14-0AB0
View
Siemens
Siemens 6ES7331-7KB02-0AB0
View
Siemens
Siemens 6ES7331-1KF02-0AB0
View
TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.