Skip to content

Siemens 6GK7343-1GX31-0XE0

CP 343-1 Advanced communications processor, gigabit and PROFINET

Siemens
Siemens 6GK7343-1GX31-0XE0 CP 343-1 Advanced communications processor, gigabit and PROFINET, photo from Siemens data sheet 6GK7343-1GX31-0XE0

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Siemens SIMATIC NET CP 343-1 Advanced: communications processor connecting an S7-300 to Industrial Ethernet, with a gigabit port and a 2-port PROFINET interface, PROFINET IO controller or device, firewall and VPN.

Manufacturer
Siemens
Manufacturer part no.
6GK7343-1GX31-0XE0
Type
Communications processor
Lifecycle
Discontinued
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Siemens
Manufacturer part no.
6GK7343-1GX31-0XE0
Type
Communications processor
Application
Industrial Ethernet communications processor
Used with
SIMATIC S7-300 rack (S7-300 backplane bus)
transfer rate / at the 1st interface
10 ... 1000 Mbit/s
transfer rate / at the 2nd interface
10 ... 100 Mbit/s
number of interfaces / according to Industrial Ethernet
3
number of electrical connections / at the 1st interface / according to Industrial Ethernet
1
number of electrical connections / at the 2nd interface / according to Industrial Ethernet
2
number of electrical connections / for power supply
1
type of electrical connection / at the 1st interface / according to Industrial Ethernet
RJ45 port
type of electrical connection / at the 2nd interface / according to Industrial Ethernet
RJ45 port
type of electrical connection / for power supply
2-pole plugable terminal block
design of the removable storage / C-PLUG
Yes
type of voltage / of the supply voltage
DC
supply voltage / 1 / from backplane bus
5 V
supply voltage / external
24 V
supply voltage / external / at DC / rated value
24 V
supply voltage, current consumption, power loss / relative positive tolerance / at DC / at 24 V
20 %
supply voltage, current consumption, power loss / relative negative tolerance / at DC / at 24 V
15 %
consumed current / from backplane bus / at DC / at 5 V / typical
0.14 A
consumed current / from external supply voltage / at DC / at 24 V / typical
0.48 A
consumed current / from external supply voltage / at DC / at 24 V / maximum
0.62 A
supply voltage, current consumption, power loss / power loss [W]
14.7 W
ambient temperature / for vertical installation / during operation
0 ... 40 °C
ambient temperature / for horizontally arranged busbars / during operation
0 ... 60 °C
ambient temperature / during storage
-40 ... +70 °C
ambient temperature / during transport
-40 ... +70 °C
relative humidity / at 25 °C / without condensation / during operation / maximum
95 %
Show all 146 specifications
ambient conditions / protection class IP
IP20
module format
Compact module
width
80 mm
height
125 mm
depth
120 mm
net weight
0.45 kg
fastening method / S7-300 rail mounting
Yes
performance data / open communication / number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum
16
data volume / as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum
8 Kibyte
data volume / as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum
8 Kibyte
data volume / as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum
8 Kibyte
data volume / as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum
2 Kibyte
performance data / open communication / number of Multicast stations
16
number of possible connections / for S7 communication / maximum
16
performance data / multi-protocol mode / number of active connections / with multi-protocol mode
48
number of possible connections / as client / by means of FTP / maximum
10
number of possible connections / as server / by means of FTP / maximum
2
number of possible connections / as server / by means of HTTP / maximum
4
number of possible connections / as email client / maximum
1
performance data / IT functions / data volume / as user data for email / maximum
8 Kibyte
storage capacity / of the user memory / as flash memory file system
28 Mibyte
storage capacity / of the user memory / as RAM
30 Mibyte
performance data / IT functions / number of possible write cycles / of the flash memory cells
100000
performance data / PROFINET communication / as PN IO controller / product function / PROFINET IO controller
Yes
performance data / PROFINET communication / as PN IO controller / number of PN IO devices / on PROFINET IO controller / operable / total
128
performance data / PROFINET communication / as PN IO controller / number of PN IO IRT devices / on PROFINET IO controller / operable
128
performance data / PROFINET communication / as PN IO controller / number of external PN IO lines / with PROFINET / per rack
1
data volume / as user data for input variables / as PROFINET IO controller / maximum
4 Kibyte
data volume / as user data for output variables / as PROFINET IO controller / maximum
4 Kibyte
data volume / as user data for input variables per PN IO device / as PROFINET IO controller / maximum
1433 byte
data volume / as user data for output variables per PN IO device / as PROFINET IO controller / maximum
1433 byte
data volume / as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum
240 byte
data volume / as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum
240 byte
performance data / PROFINET communication / as PN IO device / product function / PROFINET IO device
Yes
data volume / as user data for input variables / as PROFINET IO device / maximum
1024 byte
data volume / as user data for output variables / as PROFINET IO device / maximum
1024 byte
data volume / as user data for input variables / for each sub-module as PROFINET IO device
240 byte
data volume / as user data for output variables / for each sub-module as PROFINET IO device
240 byte
data volume / as user data for the consistency area for each sub- module
240 byte
performance data / PROFINET communication / as PN IO device / number of submodules / per PROFINET IO-Device
32
performance data / PROFINET CBA / number of remote connection partners / with PROFINET CBA
64
performance data / PROFINET CBA / number of connections / with PROFINET CBA / total
1000
data volume / as user data for digital inputs / with PROFINET CBA / maximum
8 Kibyte
data volume / as user data for digital outputs / with PROFINET CBA / maximum
8 Kibyte
data volume / as user data for arrays and data types / in the case of acyclic transmission / with PROFINET CBA / maximum
8 Kibyte
data volume / as user data for arrays and data types / with PROFINET CBA / with cyclical transfer / maximum
250 byte
data volume / as user data for arrays and data types / with PROFINET CBA / in the case of local interconnection / maximum
2400 byte
performance data / PROFINET CBA / remote interconnection / with acyclic transfer / update time / of the remote interconnections / in the case of acyclic transmission / with PROFINET CBA
100 ms
performance data / PROFINET CBA / remote interconnection / with acyclic transfer / number of remote connections to input variables / in the case of acyclic transmission / with PROFINET CBA / maximum
128
performance data / PROFINET CBA / remote interconnection / with acyclic transfer / number of remote connections to output variables / in the case of acyclic transmission / with PROFINET CBA / maximum
128
data volume / as user data for remote interconnections with input variables / in the case of acyclic transmission / with PROFINET CBA
8 Kibyte
data volume / as user data for remote interconnections with output variables / in the case of acyclic transmission / with PROFINET CBA
8 Kibyte
performance data / PROFINET CBA / remote interconnection / with cyclic transfer / update time / of the remote interconnections / with cyclical transfer / with PROFINET CBA
8 ms
performance data / PROFINET CBA / remote interconnection / with cyclic transfer / number of remote connections to input variables / with PROFINET CBA / with cyclic transfer / maximum
200
performance data / PROFINET CBA / remote interconnection / with cyclic transfer / number of remote connections to output variables / with cyclical transfer / with PROFINET CBA / maximum
200
data volume / as user data for remote interconnections with input variables / with cyclical transfer / with PROFINET CBA / maximum
2000 byte
data volume / as user data for remote interconnections with output variables / with cyclical transfer / with PROFINET CBA / maximum
2000 byte
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / number of connectable HMI stations / for HMI variables / in the case of acyclic transmission / with PROFINET CBA
3
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / update time / of the HMI variables / in the case of acyclic transmission / with PROFINET CBA
500 ms
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / number of HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum
200
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / data volume / as user data for HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum
8 Kibyte
performance data / PROFINET CBA / device-internal interconnections / number of internal connections / with PROFINET CBA / maximum
256
performance data / PROFINET CBA / device-internal interconnections / data volume / of the internal connections / with PROFINET CBA / maximum
2400 byte
performance data / PROFINET CBA / interconnections to constants / number of connections with constants / with PROFINET CBA / maximum
200
performance data / PROFINET CBA / interconnections to constants / data volume / as user data for interconnections with constants / with PROFINET CBA / maximum
4096 byte
performance data / PROFINET CBA / PROFIBUS proxy functionality / product function / with PROFINET CBA / PROFIBUS proxy functionality
No
protocol / is supported / TCP/IP
Yes
product function / MIB support
Yes
protocol / is supported / SNMP v1
Yes
protocol / is supported / SNMP v3
Yes
protocol / is supported / DCP
Yes
protocol / is supported / LLDP
Yes
configuration software / required
STEP7 V5.5 SP2 HF1 or higher / STEP 7 Professional V12 (TIA Portal) or higher
configuration software / for PROFINET CBA / required
SIMATIC iMap V3.0 SP4 and higher
identification & maintenance function / I&M0 - device-specific information
Yes
identification & maintenance function / I&M1 - higher level designation/location designation
Yes
product function / is supported / identification link
Yes; acc. to IEC 61406-1:2022
product function / web-based diagnostics
Yes
product feature / switch
Yes
product function / switch-managed
No
product function / with IRT / PROFINET IO switch
Yes
product function / configuration with STEP 7
Yes
product function / ring redundancy
Yes
product function / redundancy manager
Yes
product functions / redundancy / protocol / is supported / Media Redundancy Protocol (MRP)
Yes
product functions / security / firewall version
stateful inspection
product function / with VPN connection
IPSec
product functions / security / type of encryption algorithms / with VPN connection
AES-256, AES-192, AES-128, 3DES-168, DES-56
product functions / security / type of authentication procedure / with VPN connection
Preshared key (PSK), X.509v3 certificates
product functions / security / type of hashing algorithms / with VPN connection
MD5, SHA-1
product functions / security / number of possible connections / with VPN connection
32
product function / password protection for Web applications
Yes
product function / ACL - IP-based
Yes
product function / ACL - IP-based for PLC/routing
Yes
product function / switch-off of non-required services
Yes
product function / blocking of communication via physical ports
Yes
product function / log file for unauthorized access
No
product function / SICLOCK support
Yes
product function / pass on time synchronization
Yes
protocol / is supported / NTP
Yes
standards, specifications, approvals / certificate of suitability / CE marking
Yes
standards, specifications, approvals / certificate of suitability / UKCA marking
Yes
standards, specifications, approvals / certificate of suitability / KC approval
Yes
standards, specifications, approvals / certificate of suitability / Regulatory Compliance Mark (RCM)
Yes
standards, specifications, approvals / certificate of suitability / RoHS conformity
Yes
standards, specifications, approvals / certificate of suitability / EAC approval
Yes
standards, specifications, approvals / hazardous environments / header / certificate of suitability / ATEX
Yes
standards, specifications, approvals / hazardous environments / header / certificate of suitability / IECEx
Yes
standards, specifications, approvals / hazardous environments / header / certificate of suitability / ULhazloc approval
Yes
standards, specifications, approvals / hazardous environments / header / certificate of suitability / CCC / for hazardous zone according to GB standard
Yes
standards, specifications, approvals / hazardous environments / header / certificate of suitability / FM registration
Yes
standards, specifications, approvals / marine classification / header / Marine classification association / Polski Rejestr Statkow (PRS)
Yes
General Product Approval / Declaration of Con-
China RoHS
Approvals / Certificates / Manufacturer Declara-
Miscellaneous
Manufacturer Declara- / proval / China RoHS
FM CCC-Ex
Approvals / Certificates / last modified:
8/28/2026

Technical documents (1)

Key features

  • 1st interface: 1 RJ45 port, 10 to 1000 Mbit/s
  • 2nd interface: 2 RJ45 ports, 10 to 100 Mbit/s, PROFINET IO controller and/or device
  • Firewall and VPN, FTP, e-mail, SNMP and DHCP (Siemens's description)
  • External 24 V DC supply; 80 mm wide
  • Discontinued by Siemens on 1 October 2025; spare part only

About the Siemens 6GK7343-1GX31-0XE0

The Siemens 6GK7343-1GX31-0XE0 is the Advanced version of the CP 343-1 (the standard one is the 6GK7343-1EX30-0XE0): Siemens's description lists a gigabit port and firewall/VPN security besides PROFINET IO. Siemens's data sheet gives a 10 to 1000 Mbit/s first interface, a 2-port 10 to 100 Mbit/s second interface, an external 24 V DC supply (0.48 A typical) and an 80 mm wide module. Siemens's data sheet marks it as a spare part.

What is the 6GK7343-1GX31-0XE0 used for?

It connects an S7-300 CPU to Industrial Ethernet and to PROFINET IO devices.

Lifecycle and successor

Discontinued.

Before you order

What to photograph or confirm so the right unit is quoted.

Check the order number and firmware version on the label, and keep a record of the CP's configuration (IP addresses, firewall rules) before replacing it.

Other parts in the Siemens SIMATIC S7-300 family

Listed for reference. They differ from the 6GK7343-1GX31-0XE0 in rating, supply, interface or function and are not interchangeable with it unless Siemens says so. Match the part number on your unit.

ProductTypeLifecycleQty AvailablePriceAction
Siemens 6GK7343-1CX10-0XE0CP 343-1 Lean communications processor, Industrial EthernetCommunications processorDiscontinuedOn RequestOn requestView
Siemens 6GK7343-1EX30-0XE0CP 343-1 communications processor, Industrial Ethernet, PROFINET IO controllerCommunications processorDiscontinuedOn RequestOn requestView
Siemens 6GK7342-5DA03-0XE0CP 342-5 communications processor, PROFIBUS DP master/slaveCommunications processorDiscontinuedOn RequestOn requestView
Siemens 6ES7340-1AH02-0AE0CP 340 communications processor, RS 232CCommunications processorDiscontinuedOn RequestOn requestView
Siemens 6ES7338-4BC01-0AB0SM 338 position input module, 3 SSI encodersPosition input moduleDiscontinuedOn RequestOn requestView
Siemens 6ES7341-1CH02-0AE0CP 341 communications processor, RS 422/485Communications processorDiscontinuedOn RequestOn requestView
Siemens 6ES7341-1AH02-0AE0CP 341 communications processor, RS 232CCommunications processorDiscontinuedOn RequestOn requestView
Siemens 6GK7343-2AH11-0XA0CP 343-2P AS-Interface master for S7-300 and ET 200MCommunications processorDiscontinuedOn RequestOn requestView
Siemens 6ES7351-1AH02-0AE0FM 351 positioning module for rapid/creep traverse drivesPositioning moduleDiscontinuedOn RequestOn requestView
Siemens 6ES7352-1AH02-0AE0FM 352 electronic cam controller, 13 cam tracksCam controller moduleDiscontinuedOn RequestOn requestView
Siemens 6ES7355-0VH10-0AE0FM 355 C controller module, 4 continuous control channelsController moduleDiscontinuedOn RequestOn requestView
Siemens 6AG1321-1BL00-2AA0SIPLUS SM 321 digital input, 32 DI, 24 V DC, conformal coatingDigital input moduleDiscontinuedOn RequestOn requestView

You may also be interested in

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need Siemens 6GK7343-1GX31-0XE0? Send us the details.