Skip to content
Marine

AGC-2

DEIF Automatic genset controller

DEIF
Illustrative image of an automatic genset controller, not the exact DEIF AGC-2

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Legacy automatic genset controller in DEIF's AGC family.

Manufacturer
DEIF
Manufacturer part no.
AGC-2
Type
Automatic genset controller
Lifecycle
End of life
OEM successor
AGC-4 Mk II
Technical datasheet
Data sheet

Technical specifications

Manufacturer
DEIF
Manufacturer part no.
AGC-2
Type
Automatic genset controller
Application
Genset control / power management; confirm exact marine approvals per variant
Used with
Generator sets / power-management systems
Product
AGC-2 automatic gen-set controller, DEIF Multi-line 2
Measuring voltage
100 to 690 V AC +/-20%
Measuring current
-/1 or -/5 A AC, from CTs
Measuring frequency
30 to 70 Hz
Current overload
4 x In continuously; 20 x In for 10 s (max. 75 A); 80 x In for 1 s (max. 300 A)
Auxiliary supply
12/24 V DC (8 to 36 V continuously), max. 8 W
Relay outputs
250 V AC / 24 V DC, 5 A
Operating temperature
-25 to 70 °C
Storage temperature
-40 to 70 °C
Protection
Unit IP20; display IP52 (IP54 with gasket, option L)
EMC
EN 61000-6-1/2/3/4, IEC 60255-26, IEC 60533, IACS UR E10
Mounting
DIN rail or base mount with 6 screws
Weight
Main unit 1.6 kg
Approvals
UL/cUL Listed to UL508

Technical documents (1)

Key features

  • Automatic mains failure, island, fixed power, peak shaving and load takeover
  • Optional load sharing and power management
  • Overcurrent (2 levels) and reverse power protection
  • Separate display for switchboard door mounting
  • M-Logic configurable logic
  • GSM option for SMS alarm messages

About the DEIF AGC-2

The DEIF AGC-2 is an automatic gen-set controller from the first generation of DEIF's Multi-line 2 range. It combines three-phase measuring, generator protection and engine control for one generator set, with a separate display that can be mounted on the unit or in the switchboard door. It covers automatic mains failure, island operation, fixed power, peak shaving, load takeover and mains export, with optional load sharing and power management.

What is the AGC-2 used for?

The AGC-2 starts, stops, synchronises and protects a generator set, on its own or as part of a DEIF power management system. Replacing it like for like keeps the existing wiring and configuration; DEIF names the AGC-4 Mk II as the current controller.

Lifecycle and successor

End of life.

OEM successor: AGC-4 Mk II

Before you order

What to photograph or confirm so the right unit is quoted.

Check the item number and variant on the label and the installed options. Send a label photo and the vessel name or IMO number.

Alternatives for AGC-2

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
AGC-4 Mk IINamed by the manufacturer as the successorDEIFAutomatic genset controllerCurrent successorOEM successor (upgrade path)On RequestOn requestView ›
DEIF AGC-3Automatic genset controllerDEIFAutomatic genset controllerEnd of lifeSame familyIn Stockfrom $667.19View ›
DEIF AGC-4Automatic genset controllerDEIFAutomatic genset controllerSpare part / being phased outSame familyIn Stockfrom $2,800.00View ›
DEIF AGC 200Advanced genset controllerDEIFAdvanced genset controllerEnd of lifeSame familyOn RequestOn requestView ›
DEIF AGC plant managementPlant management controllerDEIFPlant management controllerSpare part / being phased outSame familyOn RequestOn requestView ›

You may also be interested in

TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorisation or affiliation.

Need DEIF AGC-2? Send us the details.