Siemens 6ES7314-6EH04-0AB0

CPU 314C-2 PN/DP compact CPU with integrated I/O

Request a quote
Siemens
Siemens 6ES7314-6EH04-0AB0 CPU 314C-2 PN/DP compact CPU with integrated I/O, photo from Siemens data sheet 6ES7314-6EH04-0AB0

Image is for illustrative purposes only. Please refer to product description.

  • FedEx
  • DHL
  • UPS
Manufacturer
Siemens
Manufacturer part number
6ES7314-6EH04-0AB0
Technical datasheet
Data sheet

Specifications

AttributeValue
TypePLC CPU
Manufacturer lifecycleDiscontinued
Product type designationCPU 314C-2 PN/DP
HW functional status01
Firmware versionV3.3
Product function / Isochronous modeYes; For PROFINET only
Engineering with / Programming packageSTEP 7 V5.5 or higher with HSP 191
Supply voltage / Rated value (DC)24 V
Supply voltage / permissible range, lower limit (DC)19.2 V
Supply voltage / permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A
Mains buffering / Mains/voltage failure stored energy time5 ms
Mains buffering / Repeat rate, min.1 s
Load voltage L+ / Digital inputs / Rated value (DC)24 V
Load voltage L+ / Digital inputs / Reverse polarity protectionYes
Show all 522 specifications
Load voltage L+ / Digital outputs / Rated value (DC)24 V
Load voltage L+ / Digital outputs / Reverse polarity protectionNo
Input current / Current consumption (rated value)850 mA
Input current / Current consumption (in no-load operation), typ.190 mA
Input current / Inrush current, typ.5 A
Input current / I²t0.7 A²·s
Digital inputs / from load voltage L+ (without load), max.80 mA
Digital outputs / from load voltage L+, max.50 mA
Power loss, typ.14 W
Work memory / integrated192 kbyte
Work memory / expandableNo
Load memory / Plug-in (MMC)Yes
Load memory / Plug-in (MMC), max.8 Mbyte
Load memory / Data management on MMC (after last programming), min.10 a
Backup / presentYes; Guaranteed by MMC (maintenance-free)
Backup / without batteryYes; Program and data
CPU processing times / for bit operations, typ.0.06 µs
CPU processing times / for word operations, typ.0.12 µs
CPU processing times / for fixed point arithmetic, typ.0.16 µs
CPU processing times / for floating point arithmetic, typ.0.59 µs
CPU-blocks / Number of elements (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB / Number, max.1 024; Number range: 1 to 16000
DB / Size, max.64 kbyte
FB / Number, max.1 024; Number range: 0 to 7999
FB / Size, max.64 kbyte
FC / Number, max.1 024; Number range: 0 to 7999
FC / Size, max.64 kbyte
OB / Number, max.see instruction list
OB / Size, max.64 kbyte
OB / Number of free cycle OBs1; OB 1
OB / Number of time alarm OBs1; OB 10
OB / Number of delay alarm OBs2; OB 20, 21
OB / Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
OB / Number of process alarm OBs1; OB 40
OB / Number of DPV1 alarm OBs3; OB 55, 56, 57
OB / Number of isochronous mode OBs1; OB 61; only for PROFINET
OB / Number of startup OBs1; OB 100
OB / Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
OB / Number of synchronous error OBs2; OB 121, 122
Nesting depth / per priority class16
Nesting depth / additional within an error OB4
S7 counter / Number256
S7 counter / Retentivity / adjustableYes
S7 counter / Retentivity / presetZ 0 to Z 7
S7 counter / Counting range / can be setYes
S7 counter / Counting range / lower limit0
S7 counter / Counting range / upper limit999
IEC counter / presentYes
IEC counter / TypeSFB
IEC counter / NumberUnlimited (limited only by RAM capacity)
S7 timer / Number256
S7 timer / Retentivity / adjustableYes
S7 timer / Retentivity / presetNo retentivity
S7 timer / Time range / lower limit10 ms
S7 timer / Time range / upper limit9 990 s
IEC timer / presentYes
IEC timer / TypeSFB
IEC timer / NumberUnlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.64 kbyte
Flag / Size, max.256 byte
Flag / Retentivity availableYes; MB 0 to MB 255
Flag / Retentivity presetMB 0 to MB 15
Flag / Number of clock memories8; 1 memory byte
Data blocks / Retentivity adjustableYes; via non-retain property on DB
Data blocks / Retentivity presetYes
Local data / per priority class, max.32 kbyte; Max. 2048 bytes per block
I/O address area / Inputs2 048 byte
I/O address area / Outputs2 048 byte
I/O address area / of which distributed / Inputs2 003 byte
I/O address area / of which distributed / Outputs2 010 byte
Process image / Inputs2 048 byte
Process image / Outputs2 048 byte
Process image / Inputs, adjustable2 048 byte
Process image / Outputs, adjustable2 048 byte
Process image / Inputs, default256 byte
Process image / Outputs, default256 byte
Subprocess images / Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels / Inputs16 048
Digital channels / Inputs / of which central1 016
Digital channels / Outputs16 096
Digital channels / Outputs / of which central1 008
Analog channels / Inputs1 006
Analog channels / Inputs / of which central253
Analog channels / Outputs1 007
Analog channels / Outputs / of which central250
Hardware configuration / Number of expansion units, max.3
Number of DP masters / integrated1
Number of DP masters / via CP4
Number of operable FMs and CPs (recommended) / FM8
Number of operable FMs and CPs (recommended) / CP, PtP8
Number of operable FMs and CPs (recommended) / CP, LAN10
Rack / Racks, max.4
Rack / Modules per rack, max.8; In rack 3 max. 7
Clock / Hardware clock (real-time)Yes
Clock / retentive and synchronizableYes
Clock / Backup time6 wk; At 40 °C ambient temperature
Clock / Deviation per day, max.10 s; Typ.: 2 s
Clock / Behavior of the clock following POWER-ONClock continues running after POWER OFF
Clock / Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Operating hours counter / Number1
Operating hours counter / Number/Number range0
Operating hours counter / Range of values0 to 2^31 hours (when using SFC 101)
Operating hours counter / Granularity1 h
Operating hours counter / retentiveYes; Must be restarted at each restart
Clock synchronization / supportedYes
Clock synchronization / to MPI, masterYes
Clock synchronization / on MPI, deviceYes
Clock synchronization / to DP, masterYes; With DP slave only slave clock
Clock synchronization / on DP, deviceYes
Clock synchronization / in AS, masterYes
Clock synchronization / in AS, deviceYes
Clock synchronization / on Ethernet via NTPYes; As client
Number of digital inputs24
Number of digital inputs / of which inputs usable for technological functions16
Digital inputs / integrated channels (DI)24
Digital inputs / Input characteristic curve in accordance with IEC 61131, type 1Yes
Number of simultaneously controllable inputs / horizontal installation / up to 40 °C, max.24
Number of simultaneously controllable inputs / horizontal installation / up to 60 °C, max.12
Number of simultaneously controllable inputs / vertical installation / up to 40 °C, max.12
Input voltage / Rated value (DC)24 V
Input voltage / for signal "0"-3 to +5V
Input voltage / for signal "1"+15 to +30 V
Input current / for signal "1", typ.8 mA
Input delay (for rated value of input voltage) / for standard inputs / parameterizableYes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)
Input delay (for rated value of input voltage) / for standard inputs / Rated value3 ms
Input delay (for rated value of input voltage) / for technological functions / at "0" to "1", max.8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency
Digital inputs / Cable length / shielded, max.1 000 m; 50 m for technological functions
Digital inputs / Cable length / unshielded, max.600 m; for technological functions: No
Cable length / for technological functions / shielded, max.50 m; at maximum count frequency
Cable length / for technological functions / unshielded, max.not allowed
Number of digital outputs16
Number of digital outputs / of which high-speed outputs4; Notice: You cannot connect the fast outputs of your CPU in parallel
Digital outputs / integrated channels (DO)16
Digital outputs / Short-circuit protectionYes; Clocked electronically
Short-circuit protection / Response threshold, typ.1 A
Digital outputs / Limitation of inductive shutdown voltage toL+ (-48 V)
Controlling a digital inputYes
Switching capacity of the outputs / on lamp load, max.5 W
Load resistance range / lower limit48 Ω
Load resistance range / upper limit4 kΩ
Output voltage / for signal "1", min.L+ (-0.8 V)
Output current / for signal "1" rated value500 mA
Output current / for signal "1" permissible range, min.5 mA
Output current / for signal "1" permissible range, max.0.6 A
Output current / for signal "1" minimum load current5 mA
Output current / for signal "0" residual current, max.0.5 mA
Parallel switching of two outputs / for upratingNo
Parallel switching of two outputs / for redundant control of a loadYes
Switching frequency / with resistive load, max.100 Hz
Switching frequency / with inductive load, max.0.5 Hz
Switching frequency / on lamp load, max.100 Hz
Switching frequency / of the pulse outputs, with resistive load, max.2.5 kHz
Total current of the outputs (per group) / horizontal installation / up to 40 °C, max.3 A
Total current of the outputs (per group) / horizontal installation / up to 60 °C, max.2 A
Total current of the outputs (per group) / vertical installation / up to 40 °C, max.2 A
Digital outputs / Cable length / shielded, max.1 000 m
Digital outputs / Cable length / unshielded, max.600 m
Number of analog inputs5
Number of analog inputs / For voltage/current measurement4
Number of analog inputs / For resistance/resistance thermometer measurement1
Analog inputs / integrated channels (AI)5; 4x current/voltage, 1x resistance
Analog inputs / permissible input voltage for current input (destruction limit), max.5 V; Permanent
Analog inputs / permissible input voltage for voltage input (destruction limit), max.30 V; Permanent
Analog inputs / permissible input current for voltage input (destruction limit), max.0.5 mA; Permanent
Analog inputs / permissible input current for current input (destruction limit), max.50 mA; Permanent
Analog inputs / Electrical input frequency, max.400 Hz
Analog inputs / No-load voltage for resistance-type transmitter, typ.3.3 V
Analog inputs / Constant measurement current for resistance-type transmitter, typ.1.25 mA
Analog inputs / Technical unit for temperature measurement adjustableYes; Degrees Celsius / degrees Fahrenheit / Kelvin
Input ranges / VoltageYes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ
Input ranges / CurrentYes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω
Input ranges / Resistance thermometerYes; Pt 100 / 10 MΩ
Input ranges / ResistanceYes; 0 Ω to 600 Ω / 10 MΩ
Input ranges (rated values), voltages / 0 to +10 VYes
Input ranges (rated values), voltages / 0 to +10 V / Input resistance (0 to 10 V)100 kΩ
Input ranges (rated values), currents / 0 to 20 mAYes
Input ranges (rated values), currents / 0 to 20 mA / Input resistance (0 to 20 mA)100 Ω
Input ranges (rated values), currents / -20 mA to +20 mAYes
Input ranges (rated values), currents / -20 mA to +20 mA / Input resistance (-20 mA to +20 mA)100 Ω
Input ranges (rated values), currents / 4 mA to 20 mAYes
Input ranges (rated values), currents / 4 mA to 20 mA / Input resistance (4 mA to 20 mA)100 Ω
Input ranges (rated values), resistance thermometer / Pt 100Yes
Input ranges (rated values), resistance thermometer / Pt 100 / Input resistance (Pt 100)10 MΩ
Input ranges (rated values), resistors / 0 to 600 ohmsYes
Input ranges (rated values), resistors / 0 to 600 ohms / Input resistance (0 to 600 ohms)10 MΩ
Thermocouple (TC) / Temperature compensation / ParameterizableNo
Characteristic linearization / ParameterizableYes; by software
Characteristic linearization / Parameterizable / for resistance thermometerPt 100
Analog inputs / Cable length / shielded, max.100 m
Analog outputs / integrated channels (AO)2
Analog outputs / Voltage output, short-circuit protectionYes
Analog outputs / Voltage output, short-circuit current, max.55 mA
Analog outputs / Current output, no-load voltage, max.14 V
Output ranges, voltage / 0 to 10 VYes
Output ranges, voltage / -10 V to +10 VYes
Output ranges, current / 0 to 20 mAYes
Output ranges, current / -20 mA to +20 mAYes
Output ranges, current / 4 mA to 20 mAYes
Connection of actuators / for voltage output two-wire connectionYes; Without compensation of the line resistances
Connection of actuators / for voltage output four-wire connectionNo
Connection of actuators / for current output two-wire connectionYes
Load impedance (in rated range of output) / with voltage outputs, min.1 kΩ
Load impedance (in rated range of output) / with voltage outputs, capacitive load, max.0.1 µF
Load impedance (in rated range of output) / with current outputs, max.300 Ω
Load impedance (in rated range of output) / with current outputs, inductive load, max.0.1 mH
Destruction limits against externally applied voltages and currents / Voltages at the outputs towards MANA16 V; Permanent
Destruction limits against externally applied voltages and currents / Current, max.50 mA; Permanent
Analog outputs / Cable length / shielded, max.200 m
Analog value generation for the inputs / Measurement principleActual value encryption (successive approximation)
Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.12 bit
Integration and conversion time/resolution per channel / Integration time, parameterizableYes; 16.6 / 20 ms
Integration and conversion time/resolution per channel / Interference voltage suppression for interference frequency f1 in Hz50 / 60 Hz
Integration and conversion time/resolution per channel / Time constant of the input filter0.38 ms
Integration and conversion time/resolution per channel / Basic execution time of the module (all channels released)1 ms
Integration and conversion time/resolution per channel / Conversion time (per channel)1 ms
Settling time / for resistive load0.6 ms
Settling time / for capacitive load1 ms
Settling time / for inductive load0.5 ms
Connection of signal encoders / for voltage measurementYes
Connection of signal encoders / for current measurement as 2-wire transducerYes; with external supply
Connection of signal encoders / for current measurement as 4-wire transducerYes
Connection of signal encoders / for resistance measurement with two-wire connectionYes; Without compensation of the line resistances
Connection of signal encoders / for resistance measurement with three-wire connectionNo
Connection of signal encoders / for resistance measurement with four-wire connectionNo
Connectable encoders / 2-wire sensorYes
Connectable encoders / 2-wire sensor / permissible quiescent current (2-wire sensor), max.1.5 mA
Errors/accuracies / Temperature error (relative to input range), (+/-)0.006 %/K
Errors/accuracies / Crosstalk between the inputs, min.60 dB
Errors/accuracies / Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.06 %
Errors/accuracies / Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)0.1 %
Errors/accuracies / Linearity error (relative to output range), (+/-)0.15 %
Errors/accuracies / Temperature error (relative to output range), (+/-)0.01 %/K
Errors/accuracies / Crosstalk between the outputs, min.60 dB
Errors/accuracies / Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.06 %
Operational error limit in overall temperature range / Voltage, relative to input range, (+/-)1 %
Operational error limit in overall temperature range / Current, relative to input range, (+/-)1 %
Operational error limit in overall temperature range / Resistance, relative to input range, (+/-)1 %
Operational error limit in overall temperature range / Voltage, relative to output range, (+/-)1 %
Operational error limit in overall temperature range / Current, relative to output range, (+/-)1 %
Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-)0.8 %; Linearity error ±0.06 %
Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-)0.8 %; Linearity error ±0.06 %
Basic error limit (operational limit at 25 °C) / Resistance, relative to input range, (+/-)0.8 %; Linearity error ±0.2 %
Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-)0.8 %
Basic error limit (operational limit at 25 °C) / Voltage, relative to output range, (+/-)0.8 %
Basic error limit (operational limit at 25 °C) / Current, relative to output range, (+/-)0.8 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency / Series mode interference (peak value of interference < rated value of input range), min.30 dB
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency / Common mode interference, min.40 dB
Number of PROFINET interfaces1; 2 ports (switch) RJ45
Number of RS 485 interfaces1; Combined MPI / PROFIBUS DP
Number of RS 422 interfaces0
1. Interface / Interface typeIntegrated RS 485 interface
1. Interface / IsolatedYes
Interface types / RS 485Yes
Interface types / Output current of the interface, max.200 mA
1. Interface / Protocols / MPIYes
1. Interface / Protocols / PROFIBUS DP masterYes
1. Interface / Protocols / PROFIBUS DP deviceYes
Protocols / Point-to-point connectionNo
MPI / Transmission rate, max.12 Mbit/s
MPI / Services / PG/OP communicationYes
MPI / Services / RoutingYes
MPI / Services / Global data communicationYes
MPI / Services / S7 basic communicationYes
MPI / Services / S7 communicationYes
MPI / Services / S7 communication, as clientNo; but via CP and loadable FB
MPI / Services / S7 communication, as serverYes
PROFIBUS DP master / Transmission rate, max.12 Mbit/s
PROFIBUS DP master / max. number of DP devices124
PROFIBUS DP master / Services / PG/OP communicationYes
PROFIBUS DP master / Services / RoutingYes
PROFIBUS DP master / Services / Global data communicationNo
PROFIBUS DP master / Services / S7 basic communicationYes; I blocks only
PROFIBUS DP master / Services / S7 communicationYes
PROFIBUS DP master / Services / S7 communication, as clientNo
PROFIBUS DP master / Services / S7 communication, as serverYes
PROFIBUS DP master / Services / EquidistanceYes
PROFIBUS DP master / Services / Isochronous modeNo
PROFIBUS DP master / Services / SYNC/FREEZEYes
PROFIBUS DP master / Services / activation/deactivation of DP devicesYes
PROFIBUS DP master / Services / max. number of DP devices that can be activated/deactivated at the same time8
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)Yes; as subscriber
PROFIBUS DP master / Services / DPV1Yes
PROFIBUS DP master / Address area / Inputs, max.2 kbyte
PROFIBUS DP master / Address area / Outputs, max.2 kbyte
PROFIBUS DP master / User data per DP device / Inputs, max.244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.244 byte
PROFIBUS DP device / Transmission rate, max.12 Mbit/s
PROFIBUS DP device / automatic baud rate searchYes; only with passive interface
PROFIBUS DP device / Address area, max.32
PROFIBUS DP device / User data per address area, max.32 byte
PROFIBUS DP device / Services / PG/OP communicationYes
PROFIBUS DP device / Services / RoutingYes; Only with active interface
PROFIBUS DP device / Services / Global data communicationNo
PROFIBUS DP device / Services / S7 basic communicationNo
PROFIBUS DP device / Services / S7 communicationYes
PROFIBUS DP device / Services / S7 communication, as clientNo
PROFIBUS DP device / Services / S7 communication, as serverYes; Connection configured on one side only
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)Yes
PROFIBUS DP device / Services / DPV1No
PROFIBUS DP device / Transfer memory / Inputs244 byte
PROFIBUS DP device / Transfer memory / Outputs244 byte
2. Interface / Interface typePROFINET
2. Interface / IsolatedYes
2. Interface / automatic detection of transmission rateYes; 10/100 Mbit/s
2. Interface / AutonegotiationYes
2. Interface / AutocrossingYes
2. Interface / Change of IP address at runtime, supportedYes
Interface types / RJ 45 (Ethernet)Yes
Interface types / Number of ports2
Interface types / integrated switchYes
2. Interface / Protocols / MPINo
Protocols / PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
Protocols / PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
Protocols / PROFINET CBAYes
2. Interface / Protocols / PROFIBUS DP masterNo
2. Interface / Protocols / PROFIBUS DP deviceNo
Protocols / Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Protocols / Web serverYes
Protocols / Media redundancyYes
PROFINET IO Controller / Transmission rate, max.100 Mbit/s
PROFINET IO Controller / Services / PG/OP communicationYes
PROFINET IO Controller / Services / RoutingYes
PROFINET IO Controller / Services / S7 communicationYes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
PROFINET IO Controller / Services / Isochronous modeYes; OB 61
PROFINET IO Controller / Services / IRTYes
PROFINET IO Controller / Services / Shared deviceYes
PROFINET IO Controller / Services / Prioritized startupYes
PROFINET IO Controller / Services / Number of IO devices with prioritized startup, max.32
PROFINET IO Controller / Services / Number of connectable IO Devices, max.128
PROFINET IO Controller / Services / Of which IO devices with IRT, max.64
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. / Of which IO devices with IRT, max. / of which in line, max.64
PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility"128
2. Interface / PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility" / of which in line, max.61
PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max.128
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max.128
PROFINET IO Controller / Services / Activation/deactivation of IO DevicesYes
PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max.8
PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supportedYes
PROFINET IO Controller / Services / Number of IO Devices per tool, max.8
PROFINET IO Controller / Services / Device replacement without swap mediumYes
PROFINET IO Controller / Services / Send cycles250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
PROFINET IO Controller / Services / Updating time250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details)
PROFINET IO Controller / Address area / Inputs, max.2 kbyte
PROFINET IO Controller / Address area / Outputs, max.2 kbyte
PROFINET IO Controller / Address area / User data consistency, max.1 024 byte
PROFINET IO Device / Services / PG/OP communicationYes
PROFINET IO Device / Services / RoutingYes
PROFINET IO Device / Services / S7 communicationYes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
PROFINET IO Device / Services / Isochronous modeNo
PROFINET IO Device / Services / IRTYes
PROFINET IO Device / Services / PROFIenergyYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I- Device
PROFINET IO Device / Services / Shared deviceYes
PROFINET IO Device / Services / Number of IO Controllers with shared device, max.2
PROFINET IO Device / Services / Transfer memory / Inputs, max.1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Services / Transfer memory / Outputs, max.1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Services / Submodules / Number, max.64
PROFINET IO Device / Services / Submodules / User data per submodule, max.1 024 byte
PROFINET IO Device / PROFINET CBA / acyclic transmissionYes
PROFINET IO Device / PROFINET CBA / cyclic transmissionYes
PROFINET IO Device / Open IE communication / Number of connections, max.8
PROFINET IO Device / Open IE communication / Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
PROFINET IO Device / Open IE communication / Keep-alive function, supportedYes
Protocols / PROFIsafeNo
Redundancy mode / Media redundancy / Switchover time on line break, typ.200 ms; PROFINET MRP
Redundancy mode / Media redundancy / Number of stations in the ring, max.50
Open IE communication / TCP/IPYes; via integrated PROFINET interface and loadable FBs
Open IE communication / TCP/IP / Number of connections, max.8
Open IE communication / TCP/IP / Data length for connection type 01H, max.1 460 byte
Open IE communication / TCP/IP / Data length for connection type 11H, max.32 768 byte
Open IE communication / TCP/IP / several passive connections per port, supportedYes
Open IE communication / ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
Open IE communication / ISO-on-TCP (RFC1006) / Number of connections, max.8
Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.32 768 byte
Open IE communication / UDPYes; via integrated PROFINET interface and loadable FBs
Open IE communication / UDP / Number of connections, max.8
Open IE communication / UDP / Data length, max.1 472 byte
Web server / supportedYes
Web server / User-defined websitesYes
Web server / Number of HTTP clients5
PG/OP communicationYes
Communication functions / Data record routingYes
Global data communication / supportedYes
Global data communication / Number of GD loops, max.8
Global data communication / Number of GD packets, max.8
Global data communication / Number of GD packets, transmitter, max.8
Global data communication / Number of GD packets, receiver, max.8
Global data communication / Size of GD packets, max.22 byte
Global data communication / Size of GD packet (of which consistent), max.22 byte
S7 basic communication / supportedYes
S7 basic communication / User data per job, max.76 byte
S7 basic communication / User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication / supportedYes
S7 communication / as serverYes
S7 communication / as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
S7 communication / User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication / supportedYes; via CP and loadable FC
PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load50 %
PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners32
PROFINET CBA (at set setpoint communication load) / number of master/device functions30
PROFINET CBA (at set setpoint communication load) / total of all master/device connections1 000
PROFINET CBA (at set setpoint communication load) / data length of all incoming master/device connections, max.4 000 byte
PROFINET CBA (at set setpoint communication load) / data length of all outgoing master/device connections, max.4 000 byte
PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnections500
PROFINET CBA (at set setpoint communication load) / Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
PROFINET CBA (at set setpoint communication load) / Data length per connection, max.1 400 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: Transmission interval, min.10 ms
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections200
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections200
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all incoming interconnections, max.2 000 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all outgoing interconnections, max.2 000 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length per connection, max.450 byte
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating500 ms
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables200
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max.2 000 byte
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supportedYes
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Number of linked PROFIBUS devices16
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max.240 byte; Slave-dependent
Number of connections / overall12
Number of connections / usable for PG communication11
Number of connections / usable for PG communication / reserved for PG communication1
Number of connections / usable for PG communication / adjustable for PG communication, min.1
Number of connections / usable for PG communication / adjustable for PG communication, max.11
Number of connections / usable for OP communication11
Number of connections / usable for OP communication / reserved for OP communication1
Number of connections / usable for OP communication / adjustable for OP communication, min.1
Number of connections / usable for OP communication / adjustable for OP communication, max.11
Number of connections / usable for S7 basic communication8
Number of connections / usable for S7 basic communication / reserved for S7 basic communication0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, min.0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.8
Number of connections / usable for S7 communication10
Number of connections / usable for S7 communication / reserved for S7 communication0
Number of connections / usable for S7 communication / adjustable for S7 communication, min.0
Number of connections / usable for S7 communication / adjustable for S7 communication, max.10
Number of connections / total number of instances, max.32
Number of connections / usable for routingX1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions / Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
S7 message functions / Process diagnostic messagesYes
S7 message functions / simultaneously active Alarm_S blocks, max.300
Test commissioning functions / Status blockYes; Up to 2 simultaneously
Test commissioning functions / Single stepYes
Test commissioning functions / Number of breakpoints4
Status/control / Status/control variableYes
Status/control / VariablesInputs, outputs, memory bits, DB, times, counters
Status/control / Number of variables, max.30
Status/control / Number of variables, max. / of which status variables, max.30
Status/control / Number of variables, max. / of which control variables, max.14
Forcing / ForcingYes
Forcing / Forcing, variablesInputs, outputs
Forcing / Number of variables, max.10
Diagnostic buffer / presentYes
Diagnostic buffer / Number of entries, max.500
Diagnostic buffer / Number of entries, max. / can be setNo
Diagnostic buffer / Number of entries, max. / of which powerfail-proof100; Only the last 100 entries are retained
Diagnostic buffer / Number of entries readable in RUN, max.499
Diagnostic buffer / Number of entries readable in RUN, max. / can be setYes; From 10 to 499
Diagnostic buffer / Number of entries readable in RUN, max. / preset10
Service data / Can be read outYes
Diagnostics indication LED / Status indicator digital input (green)Yes
Diagnostics indication LED / Status indicator digital output (green)Yes
Counter / Number of counters4; See "Technological Functions" manual
Counter / Counting frequency, max.60 kHz
Integrated Functions / Frequency measurementYes
Frequency measurement / Number of frequency meters4; up to 60 kHz (see "Technological Functions" manual)
Integrated Functions / controlled positioningYes
integrated function blocks (closed-loop control)Yes; PID controller (see "Technological Functions" manual)
Integrated Functions / PID controllerYes
Integrated Functions / Number of pulse outputs4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual)
Integrated Functions / Limit frequency (pulse)2.5 kHz
Potential separation digital inputs / Potential separation digital inputsYes
Potential separation digital inputs / between the channelsNo
Potential separation digital inputs / between the channels and backplane busYes
Potential separation digital outputs / Potential separation digital outputsYes
Potential separation digital outputs / between the channelsYes
Potential separation digital outputs / between the channels, in groups of8
Potential separation digital outputs / between the channels and backplane busYes
Potential separation analog inputs / Potential separation analog inputsYes; common for analog I/O
Potential separation analog inputs / between the channelsNo
Potential separation analog inputs / between the channels and backplane busYes
Potential separation analog outputs / Potential separation analog outputsYes; common for analog I/O
Potential separation analog outputs / between the channelsNo
Potential separation analog outputs / between the channels and backplane busYes
Isolation tested with600 V DC
Ambient temperature during operation / min.0 °C
Ambient temperature during operation / max.60 °C
Configuration software / STEP 7Yes; V5.5 or higher
Programming / Command setsee instruction list
Programming / Nesting levels8
Programming / System functions (SFC)see instruction list
Programming / System function blocks (SFB)see instruction list
Programming / Programming language / LADYes
Programming / Programming language / FBDYes
Programming / Programming language / STLYes
Programming / Programming language / SCLYes
Programming / Programming language / CFCYes
Programming / Programming language / GRAPHYes
Programming / Programming language / HiGraph®Yes
Know-how protection / User program protection/password protectionYes
Know-how protection / Block encryptionYes; With S7 block Privacy
Width120 mm
Height125 mm
Depth130 mm
Weight, approx.730 g
Phase-out announced (PM400)1 October 2023
Product cancellation (PM410)1 October 2025
Spare partYes, supplied by Siemens as a spare part only

Associated Products

ImageProductDescriptionStockViewAdd to RFQ
Siemens 6ES7315-2AH14-0AB0
6ES7315-2AH14-0AB0SiemensCPU 315-2 DP, 256 KB, MPI and PROFIBUS DPIn stockView
Siemens 6ES7315-2EH14-0AB0
6ES7315-2EH14-0AB0SiemensCPU 315-2 PN/DP, 384 KB, MPI/DP and PROFINETIn stockView
Siemens 6ES7317-2EK14-0AB0
6ES7317-2EK14-0AB0SiemensCPU 317-2 PN/DP, 1 MB, MPI/DP and PROFINETIn stockView
Siemens 6ES7313-5BG04-0AB0
6ES7313-5BG04-0AB0SiemensCPU 313C compact CPU with integrated I/O, MPIIn stockView
Siemens 6ES7312-1AE14-0AB0
6ES7312-1AE14-0AB0SiemensCPU 312, 32 KB, MPIIn stockView
Siemens 6ES7314-1AG14-0AB0
6ES7314-1AG14-0AB0SiemensCPU 314, 128 KB, MPIIn stockView
Siemens 6ES7313-6CG04-0AB0
6ES7313-6CG04-0AB0SiemensCPU 313C-2 DP compact CPU, 16 DI/16 DO, MPI and PROFIBUS DPIn stockView
Siemens 6ES7314-6CH04-0AB0
6ES7314-6CH04-0AB0SiemensCPU 314C-2 DP compact CPU with integrated I/O, MPI and PROFIBUS DPIn stockView
Siemens 6ES7317-2AK14-0AB0
6ES7317-2AK14-0AB0SiemensCPU 317-2 DP, 1 MB, MPI/DP and PROFIBUS DPIn stockView
Siemens 6ES7312-5BF04-0AB0
6ES7312-5BF04-0AB0SiemensCPU 312C compact, 64 KB, 10 DI/6 DO, MPIIn stockView
Siemens 6ES7318-3EL01-0AB0
6ES7318-3EL01-0AB0SiemensCPU 319-3 PN/DP, 2 MB, MPI/DP, DP and PROFINETIn stockView
Siemens 6ES7315-6FF04-0AB0
6ES7315-6FF04-0AB0SiemensCPU 315F-2 DP fail-safe, 384 KB, MPI and DPIn stockView

Product Questions

Is the 6ES7314-6EH04-0AB0 discontinued?

Yes. Its manufacturer lifecycle status is Discontinued.

Can another Siemens SIMATIC S7-300 part replace it?

Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.

Do you ship worldwide?

Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.

Related Products

  • Siemens

    6ES7322-1BL00-0AA0

    SM 322 digital output, 32 DO, 24 V DC, 0.5 A

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7331-7KF02-0AB0

    SM 331 analog input, 8 AI, U/I/thermocouple/resistance

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7307-1BA01-0AA0

    PS307 power supply, 120/230 V AC in, 24 V DC 2 A out

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7307-1KA02-0AA0

    PS307 power supply, 120/230 V AC in, 24 V DC 10 A out

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7361-3CA01-0AA0

    IM 361 interface module, expansion rack, 24 V DC

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7365-0BA01-0AA0

    IM 365 interface module pair, one expansion rack, with 1 m cable

    Same SIMATIC S7-300 system

    In stock

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need a part? Send us the part number.

Added to cart