Read from the product label
- Maker
- Siemens
- Part no.
- 6ES7317-2EK14-0AB0
- Serial / rev.
- as printed on your unit
Illustration of the unit type, not a photo of this part.
Delivery options
Siemens SIMATIC S7-300 CPU 317-2 PN/DP: central processing unit with 1 MB work memory, MPI/PROFIBUS DP interface and PROFINET interface with 2-port switch; Micro Memory Card required.
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7317-2EK14-0AB0
- Product family
- SIMATIC S7-300 PLC Modules
- Type
- PLC CPU
- Lifecycle
- Discontinued: product cancellation (Siemens SiePortal), spare part only
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7317-2EK14-0AB0
- Type
- PLC CPU
- Application
- PLC controller
- Used with
- SIMATIC S7-300 rack (S7-300 backplane bus)
- Product type designation
- CPU 317-2 PN/DP
- HW functional status
- 01
- Firmware version
- V3.2
- Product function / Isochronous mode
- Yes; Via PROFIBUS DP or PROFINET interface
- Engineering with / Programming package
- STEP 7 V5.5 or higher
- Supply voltage / Rated value (DC)
- 24 V
- Supply voltage / permissible range, lower limit (DC)
- 20.4 V
- Supply voltage / permissible range, upper limit (DC)
- 28.8 V
- external protection for power supply lines (recommendation)
- 2 A min.
- Mains buffering / Mains/voltage failure stored energy time
- 5 ms
- Mains buffering / Repeat rate, min.
- 1 s
- Input current / Current consumption (rated value)
- 750 mA
- Input current / Current consumption (in no-load operation), typ.
- 150 mA
- Input current / Inrush current, typ.
- 4 A
- Input current / I²t
- 1 A²·s
- Power loss, typ.
- 4.65 W
- Work memory / integrated
- 1 024 kbyte
- Work memory / expandable
- No
- Load memory / Plug-in (MMC)
- Yes
- Load memory / Plug-in (MMC), max.
- 8 Mbyte
- Load memory / Data management on MMC (after last programming), min.
- 10 a
- Backup / present
- Yes; Guaranteed by MMC (maintenance-free)
- Backup / without battery
- Yes; Program and data
- CPU processing times / for bit operations, typ.
- 0.025 µs
- CPU processing times / for word operations, typ.
- 0.03 µs
Show all 338 specificationsShow fewer
- CPU processing times / for fixed point arithmetic, typ.
- 0.04 µs
- CPU processing times / for floating point arithmetic, typ.
- 0.16 µs
- CPU-blocks / Number of elements (total)
- 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
- DB / Number, max.
- 2 048; Number range: 1 to 16000
- DB / Size, max.
- 64 kbyte
- FB / Number, max.
- 2 048; Number range: 0 to 7999
- FB / Size, max.
- 64 kbyte
- FC / Number, max.
- 2 048; Number range: 0 to 7999
- FC / Size, max.
- 64 kbyte
- OB / Size, max.
- 64 kbyte
- OB / Number of free cycle OBs
- 1; OB 1
- OB / Number of time alarm OBs
- 1; OB 10
- OB / Number of delay alarm OBs
- 2; OB 20, 21
- OB / Number of cyclic interrupt OBs
- 4; OB 32, 33, 34, 35
- OB / Number of process alarm OBs
- 1; OB 40
- OB / Number of DPV1 alarm OBs
- 3; OB 55, 56, 57
- OB / Number of isochronous mode OBs
- 1; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
- OB / Number of startup OBs
- 1; OB 100
- OB / Number of asynchronous error OBs
- 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
- OB / Number of synchronous error OBs
- 2; OB 121, 122
- Nesting depth / per priority class
- 16
- Nesting depth / additional within an error OB
- 4
- S7 counter / Number
- 512
- S7 counter / Retentivity / adjustable
- Yes
- S7 counter / Retentivity / preset
- Z 0 to Z 7
- S7 counter / Counting range / can be set
- Yes
- S7 counter / Counting range / lower limit
- 0
- S7 counter / Counting range / upper limit
- 999
- IEC counter / present
- Yes
- IEC counter / Type
- SFB
- IEC counter / Number
- Unlimited (limited only by RAM capacity)
- S7 timer / Number
- 512
- S7 timer / Retentivity / adjustable
- Yes
- S7 timer / Retentivity / preset
- No retentivity
- S7 timer / Time range / lower limit
- 10 ms
- S7 timer / Time range / upper limit
- 9 990 s
- IEC timer / present
- Yes
- IEC timer / Type
- SFB
- IEC timer / Number
- Unlimited (limited only by RAM capacity)
- Retentive data area (incl. timers, counters, flags), max.
- 256 kbyte
- Flag / Size, max.
- 4 096 byte
- Flag / Retentivity available
- Yes; From MB 0 to MB 4 095
- Flag / Retentivity preset
- MB 0 to MB 15
- Flag / Number of clock memories
- 8; 1 memory byte
- Data blocks / Retentivity adjustable
- Yes; via non-retain property on DB
- Data blocks / Retentivity preset
- Yes
- Local data / per priority class, max.
- 32 768 byte; Max. 2048 bytes per block
- I/O address area / Inputs
- 8 192 byte
- I/O address area / Outputs
- 8 192 byte
- I/O address area / of which distributed / Inputs
- 8 192 byte
- I/O address area / of which distributed / Outputs
- 8 192 byte
- Process image / Inputs
- 8 192 byte
- Process image / Outputs
- 8 192 byte
- Process image / Inputs, adjustable
- 8 192 byte
- Process image / Outputs, adjustable
- 8 192 byte
- Process image / Inputs, default
- 256 byte
- Process image / Outputs, default
- 256 byte
- Subprocess images / Number of subprocess images, max.
- 1; With PROFINET IO, the length of the user data is limited to 1600 bytes
- Digital channels / Inputs
- 65 536
- Digital channels / of which central
- 1 024
- Digital channels / Outputs
- 65 536
- Digital channels / of which central
- 1 024
- Analog channels / Inputs
- 4 096
- Analog channels / of which central
- 256
- Analog channels / Outputs
- 4 096
- Analog channels / of which central
- 256
- Hardware configuration / Number of expansion units, max.
- 3
- Number of DP masters / integrated
- 1
- Number of DP masters / via CP
- 4
- Number of operable FMs and CPs (recommended) / FM
- 8
- Number of operable FMs and CPs (recommended) / CP, PtP
- 8
- Number of operable FMs and CPs (recommended) / CP, LAN
- 10
- Rack / Racks, max.
- 4
- Rack / Modules per rack, max.
- 8
- Clock / Hardware clock (real-time)
- Yes
- Clock / retentive and synchronizable
- Yes
- Clock / Backup time
- 6 wk; At 40 °C ambient temperature
- Clock / Deviation per day, max.
- 10 s; Typ.: 2 s
- Clock / Behavior of the clock following POWER-ON
- Clock continues running after POWER OFF
- Clock / Behavior of the clock following expiry of backup period
- the clock continues at the time of day it had when power was switched off
- Operating hours counter / Number
- 4
- Operating hours counter / Number/Number range
- 0 to 3
- Operating hours counter / Range of values
- 0 to 2^31 hours (when using SFC 101)
- Operating hours counter / Granularity
- 1 h
- Operating hours counter / retentive
- Yes; Must be restarted at each restart
- Clock synchronization / supported
- Yes
- Clock synchronization / to MPI, master
- Yes
- Clock synchronization / on MPI, device
- Yes
- Clock synchronization / to DP, master
- Yes; With DP slave only slave clock
- Clock synchronization / on DP, device
- Yes
- Clock synchronization / in AS, master
- Yes
- Clock synchronization / in AS, device
- Yes
- Clock synchronization / on Ethernet via NTP
- Yes; As client
- Number of digital inputs
- 0
- Number of digital outputs
- 0
- Number of analog inputs
- 0
- Number of PROFINET interfaces
- 1; 2 ports (switch) RJ45
- Number of RS 485 interfaces
- 1; Combined MPI / PROFIBUS DP
- Number of RS 422 interfaces
- 0
- 1. Interface / Interface type
- Integrated RS 485 interface
- 1. Interface / Isolated
- Yes
- Interface types / RS 485
- Yes
- Interface types / Output current of the interface, max.
- 200 mA
- Protocols / MPI
- Yes
- Protocols / PROFIBUS DP master
- Yes
- Protocols / PROFIBUS DP device
- Yes
- Protocols / Point-to-point connection
- No
- MPI / Transmission rate, max.
- 12 Mbit/s
- MPI / Services / PG/OP communication
- Yes
- MPI / Services / Routing
- Yes
- MPI / Services / Global data communication
- Yes
- MPI / Services / S7 basic communication
- Yes
- MPI / Services / S7 communication
- Yes
- MPI / Services / S7 communication, as client
- No; but via CP and loadable FB
- MPI / Services / S7 communication, as server
- Yes
- PROFIBUS DP master / Transmission rate, max.
- 12 Mbit/s
- PROFIBUS DP master / max. number of DP devices
- 124
- PROFIBUS DP master / Services / PG/OP communication
- Yes
- PROFIBUS DP master / Services / Routing
- Yes
- PROFIBUS DP master / Services / Global data communication
- No
- PROFIBUS DP master / Services / S7 basic communication
- Yes; I blocks only
- PROFIBUS DP master / Services / S7 communication
- Yes
- PROFIBUS DP master / Services / S7 communication, as client
- No
- PROFIBUS DP master / Services / S7 communication, as server
- Yes
- PROFIBUS DP master / Services / Equidistance
- Yes
- PROFIBUS DP master / Services / Isochronous mode
- Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
- PROFIBUS DP master / Services / SYNC/FREEZE
- Yes
- PROFIBUS DP master / Services / activation/deactivation of DP devices
- Yes
- PROFIBUS DP master / Services / max. number of DP devices that can be activated/deactivated at the same time
- 8
- PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)
- Yes; as subscriber
- PROFIBUS DP master / Services / DPV1
- Yes
- PROFIBUS DP master / Address area / Inputs, max.
- 8 kbyte
- PROFIBUS DP master / Address area / Outputs, max.
- 8 kbyte
- PROFIBUS DP master / User data per DP device / Inputs, max.
- 244 byte
- PROFIBUS DP master / User data per DP device / Outputs, max.
- 244 byte
- PROFIBUS DP device / Transmission rate, max.
- 12 Mbit/s
- PROFIBUS DP device / automatic baud rate search
- Yes; only with passive interface
- PROFIBUS DP device / Address area, max.
- 32
- PROFIBUS DP device / User data per address area, max.
- 32 byte
- PROFIBUS DP device / Services / PG/OP communication
- Yes
- PROFIBUS DP device / Services / Routing
- Yes; Only with active interface
- PROFIBUS DP device / Services / Global data communication
- No
- PROFIBUS DP device / Services / S7 basic communication
- No
- PROFIBUS DP device / Services / S7 communication
- Yes
- PROFIBUS DP device / Services / S7 communication, as client
- No
- PROFIBUS DP device / Services / S7 communication, as server
- Yes; Connection configured on one side only
- PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)
- Yes
- PROFIBUS DP device / Services / DPV1
- No
- PROFIBUS DP device / Transfer memory / Inputs
- 244 byte
- PROFIBUS DP device / Transfer memory / Outputs
- 244 byte
- 2. Interface / Interface type
- PROFINET
- 2. Interface / Isolated
- Yes
- 2. Interface / automatic detection of transmission rate
- Yes; 10/100 Mbit/s
- 2. Interface / Autonegotiation
- Yes
- 2. Interface / Autocrossing
- Yes
- 2. Interface / Change of IP address at runtime, supported
- Yes
- Interface types / RJ 45 (Ethernet)
- Yes
- Interface types / Number of ports
- 2
- Interface types / integrated switch
- Yes
- Protocols / MPI
- No
- Protocols / PROFINET IO Controller
- Yes; Also simultaneously with IO-Device functionality
- Protocols / PROFINET IO Device
- Yes; Also simultaneously with IO Controller functionality
- Protocols / PROFINET CBA
- Yes
- Protocols / PROFIBUS DP master
- No
- Protocols / PROFIBUS DP device
- No
- Protocols / Open IE communication
- Yes; Via TCP/IP, ISO on TCP, and UDP
- Protocols / Web server
- Yes
- Protocols / Media redundancy
- Yes
- PROFINET IO Controller / Transmission rate, max.
- 100 Mbit/s
- PROFINET IO Controller / Services / PG/OP communication
- Yes
- PROFINET IO Controller / Services / Routing
- Yes
- PROFINET IO Controller / Services / S7 communication
- Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
- PROFINET IO Controller / Services / Isochronous mode
- Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
- PROFINET IO Controller / Services / IRT
- Yes
- PROFINET IO Controller / Services / Shared device
- Yes
- PROFINET IO Controller / Services / Prioritized startup
- Yes
- PROFINET IO Controller / Services / Number of IO devices with prioritized startup, max.
- 32
- PROFINET IO Controller / Services / Number of connectable IO Devices, max.
- 128
- PROFINET IO Controller / Services / Of which IO devices with IRT, max.
- 64
- PROFINET IO Controller / Services / of which in line, max.
- 64
- PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility"
- 128
- PROFINET IO Controller / Services / of which in line, max.
- 61
- PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max.
- 128
- PROFINET IO Controller / Services / of which in line, max.
- 128
- PROFINET IO Controller / Services / Activation/deactivation of IO Devices
- Yes
- PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max.
- 8
- PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supported
- Yes
- PROFINET IO Controller / Services / Number of IO Devices per tool, max.
- 8
- PROFINET IO Controller / Services / Device replacement without swap medium
- Yes
- PROFINET IO Controller / Services / Send cycles
- 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
- PROFINET IO Controller / Services / Updating time
- 250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details)
- PROFINET IO Controller / Address area / Inputs, max.
- 8 kbyte
- PROFINET IO Controller / Address area / Outputs, max.
- 8 kbyte
- PROFINET IO Controller / Address area / User data consistency, max.
- 1 024 byte
- PROFINET IO Device / Services / PG/OP communication
- Yes
- PROFINET IO Device / Services / Routing
- Yes
- PROFINET IO Device / Services / S7 communication
- Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
- PROFINET IO Device / Services / Isochronous mode
- No
- PROFINET IO Device / Services / IRT
- Yes
- PROFINET IO Device / Services / PROFIenergy
- Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I- Device
- PROFINET IO Device / Services / Shared device
- Yes
- PROFINET IO Device / Services / Number of IO Controllers with shared device, max.
- 2
- PROFINET IO Device / Transfer memory / Inputs, max.
- 1 440 byte; Per IO Controller with shared device
- PROFINET IO Device / Transfer memory / Outputs, max.
- 1 440 byte; Per IO Controller with shared device
- PROFINET IO Device / Submodules / Number, max.
- 64
- PROFINET IO Device / Submodules / User data per submodule, max.
- 1 024 byte
- PROFINET CBA / acyclic transmission
- Yes
- PROFINET CBA / cyclic transmission
- Yes
- Open IE communication / Number of connections, max.
- 16
- Open IE communication / Local port numbers used at the system end
- 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
- Open IE communication / Keep-alive function, supported
- Yes
- Protocols / PROFIsafe
- No
- Redundancy mode / Media redundancy / Switchover time on line break, typ.
- 200 ms; PROFINET MRP
- Redundancy mode / Media redundancy / Number of stations in the ring, max.
- 50
- Open IE communication / TCP/IP
- Yes; via integrated PROFINET interface and loadable FBs
- Open IE communication / Number of connections, max.
- 16
- Open IE communication / Data length for connection type 01H, max.
- 1 460 byte
- Open IE communication / Data length for connection type 11H, max.
- 32 768 byte
- Open IE communication / several passive connections per port, supported
- Yes
- Open IE communication / ISO-on-TCP (RFC1006)
- Yes; via integrated PROFINET interface and loadable FBs
- Open IE communication / Number of connections, max.
- 16
- Open IE communication / Data length, max.
- 32 768 byte
- Open IE communication / UDP
- Yes; via integrated PROFINET interface and loadable FBs
- Open IE communication / Number of connections, max.
- 16
- Open IE communication / Data length, max.
- 1 472 byte
- Web server / supported
- Yes
- Web server / User-defined websites
- Yes
- Web server / Number of HTTP clients
- 5
- PG/OP communication
- Yes
- Communication functions / Data record routing
- Yes
- Global data communication / supported
- Yes
- Global data communication / Number of GD loops, max.
- 8
- Global data communication / Number of GD packets, max.
- 8
- Global data communication / Number of GD packets, transmitter, max.
- 8
- Global data communication / Number of GD packets, receiver, max.
- 8
- Global data communication / Size of GD packets, max.
- 22 byte
- Global data communication / Size of GD packet (of which consistent), max.
- 22 byte
- S7 basic communication / supported
- Yes
- S7 basic communication / User data per job, max.
- 76 byte
- S7 basic communication / User data per job (of which consistent), max.
- 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
- S7 communication / supported
- Yes
- S7 communication / as server
- Yes
- S7 communication / as client
- Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
- S7 communication / User data per job, max.
- See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
- S5 compatible communication / supported
- Yes; via CP and loadable FC
- PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load
- 50 %
- PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners
- 32
- PROFINET CBA (at set setpoint communication load) / number of master/device functions
- 30
- PROFINET CBA (at set setpoint communication load) / total of all master/device connections
- 1 000
- PROFINET CBA (at set setpoint communication load) / data length of all incoming master/device connections, max.
- 4 000 byte
- PROFINET CBA (at set setpoint communication load) / data length of all outgoing master/device connections, max.
- 4 000 byte
- PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnections
- 500
- PROFINET CBA (at set setpoint communication load) / Data length of device-internal und PROFIBUS interconnections, max.
- 4 000 byte
- PROFINET CBA (at set setpoint communication load) / Data length per connection, max.
- 1 400 byte
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: Transmission interval, min.
- 10 ms
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections
- 200
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections
- 200
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all incoming interconnections, max.
- 2 000 byte
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all outgoing interconnections, max.
- 2 000 byte
- PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length per connection, max.
- 450 byte
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of stations that can log on for HMI variables (PN OPC/iMap)
- 3; 2x PN OPC/1x iMap
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating
- 500 ms
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables
- 200
- PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max.
- 2 000 byte
- PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supported
- Yes
- PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Number of linked PROFIBUS devices
- 16
- PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max.
- 240 byte; Slave-dependent
- Number of connections / overall
- 32
- Number of connections / usable for PG communication
- 31
- Number of connections / reserved for PG communication
- 1
- Number of connections / adjustable for PG communication, min.
- 1
- Number of connections / adjustable for PG communication, max.
- 31
- Number of connections / usable for OP communication
- 31
- Number of connections / reserved for OP communication
- 1
- Number of connections / adjustable for OP communication, min.
- 1
- Number of connections / adjustable for OP communication, max.
- 31
- Number of connections / usable for S7 basic communication
- 30
- Number of connections / reserved for S7 basic communication
- 0
- Number of connections / adjustable for S7 basic communication, min.
- 0
- Number of connections / adjustable for S7 basic communication, max.
- 30
- Number of connections / usable for S7 communication
- 16
- Number of connections / reserved for S7 communication
- 0
- Number of connections / adjustable for S7 communication, min.
- 0
- Number of connections / adjustable for S7 communication, max.
- 16
- Number of connections / total number of instances, max.
- 32
- Number of connections / usable for routing
- X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
- S7 message functions / Number of login stations for message functions, max.
- 32; Depending on the configured connections for PG/OP and S7 basic communication
- S7 message functions / Process diagnostic messages
- Yes
- S7 message functions / simultaneously active Alarm_S blocks, max.
- 300
- Test commissioning functions / Status block
- Yes; Up to 2 simultaneously
- Test commissioning functions / Single step
- Yes
- Test commissioning functions / Number of breakpoints
- 4
- Status/control / Status/control variable
- Yes
- Status/control / Variables
- Inputs, outputs, memory bits, DB, times, counters
- Status/control / Number of variables, max.
- 30
- Status/control / of which status variables, max.
- 30
- Status/control / of which control variables, max.
- 14
- Forcing / Forcing
- Yes
- Forcing / Forcing, variables
- Inputs, outputs
- Forcing / Number of variables, max.
- 10
- Diagnostic buffer / present
- Yes
- Diagnostic buffer / Number of entries, max.
- 500
- Diagnostic buffer / can be set
- No
- Diagnostic buffer / of which powerfail-proof
- 100; Only the last 100 entries are retained
- Diagnostic buffer / Number of entries readable in RUN, max.
- 499
- Diagnostic buffer / can be set
- Yes; From 10 to 499
- Diagnostic buffer / preset
- 10
- Service data / Can be read out
- Yes
Technical documents (1)
Key features
- 1 MB (1,024 KB) integrated work memory; program on a Micro Memory Card up to 8 MB
- 1st interface MPI/PROFIBUS DP, 12 Mbit/s
- 2nd interface PROFINET with 2-port switch (RJ45)
- 24 V DC supply
- Discontinued by Siemens on 1 October 2025
About the Siemens 6ES7317-2EK14-0AB0
The Siemens 6ES7317-2EK14-0AB0 is the CPU 317-2 PN/DP, a larger S7-300 CPU. Siemens's data sheet gives it 1 MB of integrated work memory, a Micro Memory Card for the program (up to 8 MB), a combined MPI/PROFIBUS DP interface at up to 12 Mbit/s and a PROFINET interface with a two-port switch on RJ45, on a 24 V DC supply. SiePortal lists it as product cancellation, so it is supplied only as a spare part. Siemens names no direct successor for the order number; its route forward is migration to the S7-1500.
What is the 6ES7317-2EK14-0AB0 used for?
It is the controller of an S7-300 station: it runs the STEP 7 program and drives the I/O modules on its rack and the remote I/O on its networks. A failed CPU stops the machine or line it controls. The 317 is used where a 315's memory is not enough: larger programs and more networked I/O.
Lifecycle and successor
Discontinued: product cancellation (Siemens SiePortal), spare part only.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the full order number and the firmware version on the CPU's label, and read the program size from the project if you can: a replacement must match or exceed the work memory. The Micro Memory Card (MMC) holding the program is a separate part; send its order number and size too.
Alternatives for 6ES7317-2EK14-0AB0
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| Siemens 6ES7315-2AH14-0AB0CPU 315-2 DP, 256 KB, MPI and PROFIBUS DP | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7315-2EH14-0AB0CPU 315-2 PN/DP, 384 KB, MPI/DP and PROFINET | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7314-6EH04-0AB0CPU 314C-2 PN/DP compact CPU with integrated I/O | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7313-5BG04-0AB0CPU 313C compact CPU with integrated I/O, MPI | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7321-1BL00-0AA0SM 321 digital input, 32 DI, 24 V DC | Siemens | Digital input module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7322-1BL00-0AA0SM 322 digital output, 32 DO, 24 V DC, 0.5 A | Siemens | Digital output module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7331-7KF02-0AB0SM 331 analog input, 8 AI, U/I/thermocouple/resistance | Siemens | Analog input module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7332-5HF00-0AB0SM 332 analog output, 8 AO, voltage/current | Siemens | Analog output module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7307-1EA01-0AA0PS307 power supply, 120/230 V AC in, 24 V DC 5 A out | Siemens | Power supply | Phase-out announced (Siemens SiePortal) | Same family | On Request | On request | View › |
| Siemens 6GK7343-1CX10-0XE0CP 343-1 Lean communications processor, Industrial Ethernet | Siemens | Communications processor | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6GK7343-1EX30-0XE0CP 343-1 communications processor, Industrial Ethernet, PROFINET IO controller | Siemens | Communications processor | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6GK7342-5DA03-0XE0CP 342-5 communications processor, PROFIBUS DP master/slave | Siemens | Communications processor | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
You may also be interested in
Siemens
Siemens 6ES7972-0BA12-0XA0
View ›Siemens
Siemens 6ES7972-0BB12-0XA0
View ›Siemens
Siemens 6ES7972-0BA42-0XA0
View ›Siemens
Siemens 6ES7972-0BB42-0XA0
View ›Siemens
Siemens 6ES7972-0BA52-0XA0
View ›Siemens
Siemens 6ES7972-0BB52-0XA0
View ›Siemens
Siemens 6ES7972-0BA61-0XA0
View ›Siemens
Siemens 6ES7972-0BA70-0XA0
View ›Siemens
Siemens 6GK1500-0FC10
View ›Siemens
Siemens 6GK1901-1BB10-2AA0
View ›Siemens
Siemens 6GK1901-1BB11-2AA0
View ›Siemens
Siemens 6XV1830-0EH10
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorisation or affiliation.