Image is for illustrative purposes only. Please refer to product description.
- Manufacturer
- Siemens
- Manufacturer part number
- 6ES7318-3EL01-0AB0
- Product family
- SIMATIC S7-300 PLC Modules
- Category
- PLCs and I/O › CPU and processor modules
- Technical datasheet
- Data sheet
Specifications
| Attribute | Value |
|---|---|
| Type | PLC CPU |
| Manufacturer lifecycle | Discontinued |
| Product type designation | CPU 319-3 PN/DP |
| HW functional status | 01 |
| Firmware version | V3.2 |
| Product function / Isochronous mode | Yes; Via 2nd PROFIBUS DP or PROFINET interface |
| Engineering with / Programming package | STEP 7 V5.5 or higher |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| external protection for power supply lines (recommendation) | 2 A min. |
| Mains buffering / Mains/voltage failure stored energy time | 5 ms |
| Mains buffering / Repeat rate, min. | 1 s |
| Input current / Current consumption (rated value) | 1 250 mA |
| Input current / Current consumption (in no-load operation), typ. | 500 mA |
Show all 369 specificationsShow fewer specifications
| Input current / Inrush current, typ. | 4 A |
|---|---|
| Input current / I²t | 1.2 A²·s |
| Power loss, typ. | 14 W |
| Work memory / Integrated | 2 048 kbyte |
| Work memory / expandable | No |
| Load memory / Plug-in (MMC) | Yes |
| Load memory / Plug-in (MMC), max. | 8 Mbyte |
| Load memory / Data management on MMC (after last programming), min. | 10 a |
| Backup / present | Yes |
| Backup / without battery | Yes |
| CPU processing times / for bit operations, typ. | 0.004 µs |
| CPU processing times / for word operations, typ. | 0.01 µs |
| CPU processing times / for fixed point arithmetic, typ. | 0.01 µs |
| CPU processing times / for floating point arithmetic, typ. | 0.04 µs |
| CPU-blocks / Number of elements (total) | 4 096; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
| DB / Number, max. | 4 096; Number range: 1 to 16000 |
| DB / Size, max. | 64 kbyte |
| FB / Number, max. | 4 096; Number range: 0 to 7999 |
| FB / Size, max. | 64 kbyte |
| FC / Number, max. | 4 096; Number range: 0 to 7999 |
| FC / Size, max. | 64 kbyte |
| OB / Size, max. | 64 kbyte |
| OB / Number of free cycle OBs | 1; OB 1 |
| OB / Number of time alarm OBs | 1; OB 10 |
| OB / Number of delay alarm OBs | 2; OB 20, 21 |
| OB / Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 (OB 35: smallest settable clock pulse = 500 µs) |
| OB / Number of process alarm OBs | 1; OB 40 |
| OB / Number of DPV1 alarm OBs | 3; OB 55, 56, 57 |
| OB / Number of isochronous mode OBs | 1; OB 61 |
| OB / Number of startup OBs | 1; OB 100 |
| OB / Number of asynchronous error OBs | 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) |
| OB / Number of synchronous error OBs | 2; OB 121, 122 |
| Nesting depth / per priority class | 16 |
| Nesting depth / additional within an error OB | 4 |
| S7 counter / Number | 2 048 |
| S7 counter / Retentivity / can be set | Yes |
| S7 counter / Retentivity / preset | Z 0 to Z 7 |
| S7 counter / Counting range / can be set | Yes |
| S7 counter / Counting range / lower limit | 0 |
| S7 counter / Counting range / upper limit | 999 |
| IEC counter / present | Yes |
| IEC counter / Type | SFB |
| IEC counter / Number | Unlimited (limited only by RAM capacity) |
| S7 timer / Number | 2 048 |
| S7 timer / Retentivity / adjustable | Yes |
| S7 timer / Retentivity / preset | No retentivity |
| S7 timer / Time range / lower limit | 10 ms |
| S7 timer / Time range / upper limit | 9 990 s |
| IEC timer / present | Yes |
| IEC timer / Type | SFB |
| IEC timer / Number | Unlimited (limited only by RAM capacity) |
| Retentive data area (incl. timers, counters, flags), max. | 700 kbyte |
| Flag / Size, max. | 8 192 byte |
| Flag / Retentivity available | Yes; From MB 0 to MB 8 191 |
| Flag / Retentivity preset | MB 0 to MB 15 |
| Flag / Number of clock memories | 8; 1 memory byte |
| Data blocks / Retentivity adjustable | Yes; via non-retain property on DB |
| Data blocks / Retentivity preset | Yes |
| Local data / per priority class, max. | 32 768 byte; Max. 2048 bytes per block |
| I/O address area / Inputs | 8 192 byte |
| I/O address area / Outputs | 8 192 byte |
| I/O address area / of which distributed / Inputs | 8 192 byte |
| I/O address area / of which distributed / Outputs | 8 192 byte |
| Process image / Inputs | 8 192 byte |
| Process image / Outputs | 8 192 byte |
| Process image / Inputs, adjustable | 8 192 byte |
| Process image / Outputs, adjustable | 8 192 byte |
| Process image / Inputs, default | 256 byte |
| Process image / Outputs, default | 256 byte |
| Subprocess images / Number of subprocess images, max. | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes |
| Digital channels / Inputs | 65 536 |
| Digital channels / Inputs / of which central | 1 024 |
| Digital channels / Outputs | 65 536 |
| Digital channels / Outputs / of which central | 1 024 |
| Analog channels / Inputs | 4 096 |
| Analog channels / Inputs / of which central | 256 |
| Analog channels / Outputs | 4 096 |
| Analog channels / Outputs / of which central | 256 |
| Number of DP masters / integrated | 2 |
| Number of DP masters / via CP | 4 |
| Number of operable FMs and CPs (recommended) / FM | 8 |
| Number of operable FMs and CPs (recommended) / CP, PtP | 8 |
| Number of operable FMs and CPs (recommended) / CP, LAN | 10 |
| Rack / Racks, max. | 4 |
| Rack / Modules per rack, max. | 8 |
| Clock / Hardware clock (real-time) | Yes |
| Clock / retentive and synchronizable | Yes |
| Clock / Backup time | 6 wk; At 40 °C ambient temperature |
| Clock / Deviation per day, max. | 10 s; Typ.: 2 s |
| Clock / Behavior of the clock following POWER-ON | Clock continues running after POWER OFF |
| Clock / Behavior of the clock following expiry of backup period | the clock continues at the time of day it had when power was switched off |
| Operating hours counter / Number | 4 |
| Operating hours counter / Number/Number range | 0 to 3 |
| Operating hours counter / Range of values | 0 to 2^31 hours (when using SFC 101) |
| Operating hours counter / Granularity | 1 h |
| Operating hours counter / retentive | Yes; Must be restarted at each restart |
| Clock synchronization / supported | Yes |
| Clock synchronization / to MPI, master | Yes |
| Clock synchronization / on MPI, device | Yes |
| Clock synchronization / to DP, master | Yes; With DP slave only slave clock |
| Clock synchronization / on DP, device | Yes |
| Clock synchronization / in AS, master | Yes |
| Clock synchronization / in AS, device | Yes |
| Clock synchronization / on Ethernet via NTP | Yes; As client |
| Number of digital inputs | 0 |
| Number of digital outputs | 0 |
| Number of analog inputs | 0 |
| Number of PROFINET interfaces | 1; 2 ports (switch) RJ45 |
| Number of RS 485 interfaces | 2; Combined MPI / PROFIBUS DP and PROFIBUS DP |
| Number of RS 422 interfaces | 0 |
| 1. Interface / Interface type | Integrated RS 485 interface |
| 1. Interface / Isolated | Yes |
| Interface types / RS 485 | Yes |
| 1. Interface / Interface types / Output current of the interface, max. | 150 mA |
| 1. Interface / Protocols / MPI | Yes |
| 1. Interface / Protocols / PROFIBUS DP master | Yes |
| 1. Interface / Protocols / PROFIBUS DP device | Yes; A DP slave at both interfaces simultaneously is not possible |
| Protocols / Point-to-point connection | No |
| MPI / Transmission rate, max. | 12 Mbit/s |
| MPI / Services / PG/OP communication | Yes |
| MPI / Services / Routing | Yes |
| MPI / Services / Global data communication | Yes |
| MPI / Services / S7 basic communication | Yes |
| MPI / Services / S7 communication | Yes |
| MPI / Services / S7 communication, as client | No; but via CP and loadable FB |
| MPI / Services / S7 communication, as server | Yes |
| PROFIBUS DP master / Transmission rate, max. | 12 Mbit/s |
| PROFIBUS DP master / max. number of DP devices | 124 |
| PROFIBUS DP master / Services / PG/OP communication | Yes |
| PROFIBUS DP master / Services / Routing | Yes |
| PROFIBUS DP master / Services / Global data communication | No |
| PROFIBUS DP master / Services / S7 basic communication | Yes; I blocks only |
| PROFIBUS DP master / Services / S7 communication | Yes |
| PROFIBUS DP master / Services / S7 communication, as client | No |
| 1. Interface / PROFIBUS DP master / Services / S7 communication, as server | Yes |
| PROFIBUS DP master / Services / Equidistance | Yes |
| 1. Interface / PROFIBUS DP master / Services / Isochronous mode | No |
| PROFIBUS DP master / Services / SYNC/FREEZE | Yes |
| PROFIBUS DP master / Services / activation/deactivation of DP devices | Yes |
| PROFIBUS DP master / Services / max. number of DP devices that can be activated/deactivated at the same time | 8 |
| PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication) | Yes; as subscriber |
| PROFIBUS DP master / Services / DPV1 | Yes |
| PROFIBUS DP master / Address area / Inputs, max. | 8 kbyte |
| PROFIBUS DP master / Address area / Outputs, max. | 8 kbyte |
| PROFIBUS DP master / User data per DP device / Inputs, max. | 244 byte |
| PROFIBUS DP master / User data per DP device / Outputs, max. | 244 byte |
| PROFIBUS DP device / Transmission rate, max. | 12 Mbit/s |
| PROFIBUS DP device / automatic baud rate search | Yes; only with passive interface |
| PROFIBUS DP device / Address area, max. | 32 |
| PROFIBUS DP device / User data per address area, max. | 32 byte |
| PROFIBUS DP device / Services / PG/OP communication | Yes |
| PROFIBUS DP device / Services / Routing | Yes; with interface active |
| PROFIBUS DP device / Services / Global data communication | No |
| PROFIBUS DP device / Services / S7 basic communication | No |
| PROFIBUS DP device / Services / S7 communication | Yes |
| PROFIBUS DP device / Services / S7 communication, as client | No |
| PROFIBUS DP device / Services / S7 communication, as server | Yes; Connection configured on one side only |
| PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication) | Yes |
| PROFIBUS DP device / Services / DPV1 | No |
| PROFIBUS DP device / Transfer memory / Inputs | 244 byte |
| PROFIBUS DP device / Transfer memory / Outputs | 244 byte |
| 2. Interface / Interface type | Integrated RS 485 interface |
| 2. Interface / Isolated | Yes |
| 2. Interface / Interface types / Output current of the interface, max. | 200 mA |
| 2. Interface / Protocols / MPI | No |
| 2. Interface / Protocols / PROFINET IO Controller | No |
| 2. Interface / Protocols / PROFINET IO device | No |
| 2. Interface / Protocols / PROFINET CBA | No |
| 2. Interface / Protocols / PROFIBUS DP master | Yes |
| 2. Interface / Protocols / PROFIBUS DP device | Yes; A DP slave at both interfaces simultaneously is not possible |
| 2. Interface / Protocols / Open IE communication | No |
| 2. Interface / Protocols / Web server | No |
| 2. Interface / PROFIBUS DP master / Services / S7 communication, as server | Yes; Connection configured on one side only |
| 2. Interface / PROFIBUS DP master / Services / Isochronous mode | Yes; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously) |
| 3. Interface / Interface type | PROFINET |
| 3. Interface / Isolated | Yes |
| 3. Interface / automatic detection of transmission rate | Yes; 10/100 Mbit/s |
| 3. Interface / Autonegotiation | Yes |
| 3. Interface / Autocrossing | Yes |
| 3. Interface / Change of IP address at runtime, supported | Yes |
| Interface types / RJ 45 (Ethernet) | Yes |
| Interface types / Number of ports | 2 |
| Interface types / integrated switch | Yes |
| 3. Interface / Protocols / MPI | No |
| 3. Interface / Protocols / PROFINET IO Controller | Yes; Also simultaneously with I-Device functionality |
| 3. Interface / Protocols / PROFINET IO device | Yes; Also simultaneously with IO Controller functionality |
| 3. Interface / Protocols / PROFINET CBA | Yes |
| 3. Interface / Protocols / PROFIBUS DP master | No |
| 3. Interface / Protocols / PROFIBUS DP device | No |
| 3. Interface / Protocols / Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP |
| 3. Interface / Protocols / Web server | Yes |
| Protocols / Media redundancy | Yes |
| PROFINET IO Controller / Transmission rate, max. | 100 Mbit/s |
| PROFINET IO Controller / Services / PG/OP communication | Yes |
| PROFINET IO Controller / Services / Routing | Yes |
| PROFINET IO Controller / Services / S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 |
| PROFINET IO Controller / Services / Isochronous mode | Yes; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously) |
| PROFINET IO Controller / Services / Shared device | Yes |
| PROFINET IO Controller / Services / Prioritized startup | Yes |
| PROFINET IO Controller / Services / Number of IO devices with prioritized startup, max. | 32 |
| PROFINET IO Controller / Services / Number of connectable IO Devices, max. | 256 |
| PROFINET IO Controller / Services / Of which IO devices with IRT, max. | 64 |
| 3. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. / Of which IO devices with IRT, max. / of which in line, max. | 64 |
| PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility" | 256 |
| 3. Interface / PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility" / of which in line, max. | 61 |
| PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. | 256 |
| 3. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max. | 256 |
| PROFINET IO Controller / Services / Activation/deactivation of IO Devices | Yes |
| PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
| PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supported | Yes |
| PROFINET IO Controller / Services / Number of IO Devices per tool, max. | 8 |
| PROFINET IO Controller / Services / Device replacement without swap medium | Yes |
| PROFINET IO Controller / Services / Send cycles | 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) |
| PROFINET IO Controller / Services / Updating time | 250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details) |
| PROFINET IO Controller / Address area / Inputs, max. | 8 kbyte |
| PROFINET IO Controller / Address area / Outputs, max. | 8 kbyte |
| PROFINET IO Controller / Address area / User data consistency, max. | 1 024 byte |
| PROFINET IO Device / Services / PG/OP communication | Yes |
| PROFINET IO Device / Services / Routing | Yes |
| PROFINET IO Device / Services / S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 |
| PROFINET IO Device / Services / Isochronous mode | No |
| PROFINET IO Device / Services / IRT | Yes |
| PROFINET IO Device / Services / PROFIenergy | Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I- Device |
| PROFINET IO Device / Services / Shared device | Yes |
| PROFINET IO Device / Services / Number of IO Controllers with shared device, max. | 2 |
| PROFINET IO Device / Transfer memory / Inputs, max. | 1 440 byte; Per IO Controller with shared device |
| PROFINET IO Device / Transfer memory / Outputs, max. | 1 440 byte; Per IO Controller with shared device |
| PROFINET IO Device / Submodules / Number, max. | 64 |
| PROFINET IO Device / Submodules / User data per submodule, max. | 1 024 byte |
| PROFINET CBA / acyclic transmission | Yes |
| PROFINET CBA / cyclic transmission | Yes |
| Open IE communication / Number of connections, max. | 32 |
| Open IE communication / Local port numbers used at the system end | 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
| Open IE communication / Keep-alive function, supported | Yes |
| Protocols / PROFIsafe | No |
| Redundancy mode / Media redundancy / Switchover time on line break, typ. | 200 ms; PROFINET MRP |
| Redundancy mode / Media redundancy / Number of stations in the ring, max. | 50 |
| Open IE communication / TCP/IP | Yes; via integrated PROFINET interface and loadable FBs |
| Open IE communication / TCP/IP / Number of connections, max. | 32 |
| Open IE communication / TCP/IP / Data length for connection type 01H, max. | 1 460 byte |
| Open IE communication / TCP/IP / Data length for connection type 11H, max. | 32 768 byte |
| Open IE communication / TCP/IP / several passive connections per port, supported | Yes |
| Open IE communication / ISO-on-TCP (RFC1006) | Yes; via integrated PROFINET interface and loadable FBs |
| Open IE communication / ISO-on-TCP (RFC1006) / Number of connections, max. | 32 |
| Open IE communication / ISO-on-TCP (RFC1006) / Data length, max. | 32 768 byte |
| Open IE communication / UDP | Yes; via integrated PROFINET interface and loadable FBs |
| Open IE communication / UDP / Number of connections, max. | 32 |
| Open IE communication / UDP / Data length, max. | 1 472 byte |
| Web server / supported | Yes |
| Web server / User-defined websites | Yes |
| Web server / Number of HTTP clients | 5 |
| PG/OP communication | Yes |
| Communication functions / Data record routing | Yes |
| Global data communication / supported | Yes |
| Global data communication / Number of GD loops, max. | 8 |
| Global data communication / Number of GD packets, max. | 8 |
| Global data communication / Number of GD packets, transmitter, max. | 8 |
| Global data communication / Number of GD packets, receiver, max. | 8 |
| Global data communication / Size of GD packets, max. | 22 byte |
| Global data communication / Size of GD packet (of which consistent), max. | 22 byte |
| S7 basic communication / supported | Yes |
| S7 basic communication / User data per job, max. | 76 byte |
| S7 basic communication / User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
| S7 communication / supported | Yes |
| S7 communication / as server | Yes |
| S7 communication / as client | Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB |
| S7 communication / User data per job, max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) |
| S5 compatible communication / supported | Yes; via CP and loadable FC |
| PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load | 20 % |
| PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners | 32 |
| PROFINET CBA (at set setpoint communication load) / number of master/device functions | 50 |
| PROFINET CBA (at set setpoint communication load) / total of all master/device connections | 3 000 |
| PROFINET CBA (at set setpoint communication load) / data length of all incoming master/device connections, max. | 24 000 byte |
| PROFINET CBA (at set setpoint communication load) / data length of all outgoing master/device connections, max. | 24 000 byte |
| PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnections | 1 000 |
| PROFINET CBA (at set setpoint communication load) / Data length of device-internal und PROFIBUS interconnections, max. | 8 000 byte |
| PROFINET CBA (at set setpoint communication load) / Data length per connection, max. | 1 400 byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: Transmission interval, min. | 1 ms |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections | 300 |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections | 300 |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all incoming interconnections, max. | 4 800 byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all outgoing interconnections, max. | 4 800 byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length per connection, max. | 450 byte |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of stations that can log on for HMI variables (PN OPC/iMap) | 3; 2x PN OPC/1x iMap |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating | 500 ms |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables | 600 |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max. | 9 600 byte |
| PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supported | Yes |
| PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Number of linked PROFIBUS devices | 32 |
| PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max. | 240 byte; Slave-dependent |
| Number of connections / overall | 32 |
| Number of connections / usable for PG communication | 31 |
| Number of connections / usable for PG communication / reserved for PG communication | 1 |
| Number of connections / usable for PG communication / adjustable for PG communication, min. | 1 |
| Number of connections / usable for PG communication / adjustable for PG communication, max. | 31 |
| Number of connections / usable for OP communication | 31 |
| Number of connections / usable for OP communication / reserved for OP communication | 1 |
| Number of connections / usable for OP communication / adjustable for OP communication, min. | 1 |
| Number of connections / usable for OP communication / adjustable for OP communication, max. | 31 |
| Number of connections / usable for S7 basic communication | 30 |
| Number of connections / usable for S7 basic communication / reserved for S7 basic communication | 0 |
| Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, min. | 0 |
| Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max. | 30 |
| Number of connections / usable for S7 communication | 16 |
| Number of connections / usable for S7 communication / reserved for S7 communication | 0 |
| Number of connections / usable for S7 communication / adjustable for S7 communication, min. | 0 |
| Number of connections / usable for S7 communication / adjustable for S7 communication, max. | 16 |
| Number of connections / total number of instances, max. | 32 |
| Number of connections / usable for routing | X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as DP master: max. 24; X2 as DP slave (active): max. 14; X3 as PROFINET: 48 max. |
| S7 message functions / Number of login stations for message functions, max. | 32; Depending on the configured connections for PG/OP and S7 basic communication |
| S7 message functions / Process diagnostic messages | Yes |
| S7 message functions / simultaneously active Alarm_S blocks, max. | 300 |
| Test commissioning functions / Status block | Yes; Up to 2 simultaneously |
| Test commissioning functions / Single step | Yes |
| Test commissioning functions / Number of breakpoints | 4 |
| Status/control / Status/control variable | Yes |
| Status/control / Variables | Inputs, outputs, memory bits, DB, times, counters |
| Status/control / Number of variables, max. | 30 |
| Status/control / Number of variables, max. / of which status variables, max. | 30 |
| Status/control / Number of variables, max. / of which control variables, max. | 14 |
| Forcing / Forcing | Yes |
| Forcing / Forcing, variables | Inputs, outputs |
| Forcing / Number of variables, max. | 10 |
| Diagnostic buffer / present | Yes |
| Diagnostic buffer / Number of entries, max. | 500 |
| Diagnostic buffer / Number of entries, max. / can be set | No |
| Diagnostic buffer / Number of entries, max. / of which powerfail-proof | 100 |
| Diagnostic buffer / Number of entries readable in RUN, max. | 499 |
| Diagnostic buffer / Number of entries readable in RUN, max. / can be set | Yes; From 10 to 499 |
| Diagnostic buffer / Number of entries readable in RUN, max. / preset | 10 |
| Service data / Can be read out | Yes |
| Ambient temperature during operation / min. | 0 °C |
| Ambient temperature during operation / max. | 60 °C |
| Configuration software / STEP 7 | Yes; V5.5 or higher |
| Programming / Command set | see instruction list |
| Programming / Nesting levels | 8 |
| Programming / System functions (SFC) | see instruction list |
| Programming / System function blocks (SFB) | see instruction list |
| Programming / Programming language / LAD | Yes |
| Programming / Programming language / FBD | Yes |
| Programming / Programming language / STL | Yes |
| Programming / Programming language / SCL | Yes |
| Programming / Programming language / CFC | Yes |
| Programming / Programming language / GRAPH | Yes |
| Programming / Programming language / HiGraph® | Yes |
| Know-how protection / User program protection/password protection | Yes |
| Know-how protection / Block encryption | Yes; With S7 block Privacy |
| Width | 120 mm |
| Height | 125 mm |
| Depth | 130 mm |
| Weight, approx. | 1 250 g |
| Phase-out announced (PM400) | 1 October 2023 |
| Product cancellation (PM410) | 1 October 2025 |
| Spare part | Yes, supplied by Siemens as a spare part only |
Description
The Siemens 6ES7318-3EL01-0AB0 is the CPU 319-3 PN/DP, the largest standard CPU of the S7-300 range in this catalogue. Siemens's data sheet gives it 2 MB of integrated work memory and three interfaces: MPI/PROFIBUS DP at 12 Mbit/s, a second PROFIBUS DP interface, and PROFINET with a two-port switch that supports media redundancy. It runs on 24 V DC, and the program is held on a Micro Memory Card. Siemens's data sheet marks it as a spare part.
Application: PLC controller
Used with: SIMATIC S7-300 rack (S7-300 backplane bus)
What is the 6ES7318-3EL01-0AB0 used for?
It runs large S7-300 stations with a lot of program and distributed I/O on both PROFIBUS and PROFINET. It is found on complex machines and production lines where the smaller CPUs ran out of memory or interfaces.
Key features
- 2 MB integrated work memory
- 1st interface MPI/DP 12 Mbit/s
- 2nd interface PROFIBUS DP master/slave
- 3rd interface PROFINET with 2-port switch (RJ45), media redundancy (MRP)
- Isochronous mode via PROFIBUS DP or PROFINET
- Siemens lists it as a spare part
Documents and Resources
Associated Products
| Image | Product | Description | Stock | View | Add to RFQ |
|---|---|---|---|---|---|
![]() | 6ES7315-2AH14-0AB0Siemens | CPU 315-2 DP, 256 KB, MPI and PROFIBUS DP | In stock | View | |
![]() | 6ES7315-2EH14-0AB0Siemens | CPU 315-2 PN/DP, 384 KB, MPI/DP and PROFINET | In stock | View | |
![]() | 6ES7317-2EK14-0AB0Siemens | CPU 317-2 PN/DP, 1 MB, MPI/DP and PROFINET | In stock | View | |
![]() | 6ES7314-6EH04-0AB0Siemens | CPU 314C-2 PN/DP compact CPU with integrated I/O | In stock | View | |
![]() | 6ES7313-5BG04-0AB0Siemens | CPU 313C compact CPU with integrated I/O, MPI | In stock | View | |
![]() | 6ES7312-1AE14-0AB0Siemens | CPU 312, 32 KB, MPI | In stock | View | |
![]() | 6ES7314-1AG14-0AB0Siemens | CPU 314, 128 KB, MPI | In stock | View | |
![]() | 6ES7313-6CG04-0AB0Siemens | CPU 313C-2 DP compact CPU, 16 DI/16 DO, MPI and PROFIBUS DP | In stock | View | |
![]() | 6ES7314-6CH04-0AB0Siemens | CPU 314C-2 DP compact CPU with integrated I/O, MPI and PROFIBUS DP | In stock | View | |
![]() | 6ES7317-2AK14-0AB0Siemens | CPU 317-2 DP, 1 MB, MPI/DP and PROFIBUS DP | In stock | View | |
![]() | 6ES7312-5BF04-0AB0Siemens | CPU 312C compact, 64 KB, 10 DI/6 DO, MPI | In stock | View | |
![]() | 6ES7315-6FF04-0AB0Siemens | CPU 315F-2 DP fail-safe, 384 KB, MPI and DP | In stock | View |
Product Questions
Is the 6ES7318-3EL01-0AB0 discontinued?
Yes. Its manufacturer lifecycle status is Discontinued.
Can another Siemens SIMATIC S7-300 part replace it?
Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.
Do you ship worldwide?
Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.
Related Products
Siemens
6ES7323-1BL00-0AA0SM 323 digital I/O, 16 DI and 16 DO, 24 V DC
Same SIMATIC S7-300 system
In stock
Siemens
6ES7331-7KB02-0AB0SM 331 analog input, 2 AI, U/I/thermocouple/resistance
Same SIMATIC S7-300 system
In stock
Siemens
6ES7307-1BA01-0AA0PS307 power supply, 120/230 V AC in, 24 V DC 2 A out
Same SIMATIC S7-300 system
In stock
Siemens
6ES7307-1KA02-0AA0PS307 power supply, 120/230 V AC in, 24 V DC 10 A out
Same SIMATIC S7-300 system
In stock
Siemens
6ES7361-3CA01-0AA0IM 361 interface module, expansion rack, 24 V DC
Same SIMATIC S7-300 system
In stock
Siemens
6ES7365-0BA01-0AA0IM 365 interface module pair, one expansion rack, with 1 m cable
Same SIMATIC S7-300 system
In stock