Siemens SIMATIC S7-300 CPU 313C: compact CPU with 128 KB work memory, MPI, 24 DI/16 DO, 4 AI, 2 AO, 1 Pt100 and 3 high-speed counters, 24 V DC.
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7313-5BG04-0AB0
- Product family
- SIMATIC S7-300 PLC Modules
- Type
- PLC CPU
- Lifecycle
- Discontinued: product cancellation (Siemens SiePortal), spare part only
- OEM successor
- Not stated
- Technical datasheet
- Data sheet
Technical specifications
- Manufacturer
- Siemens
- Manufacturer part no.
- 6ES7313-5BG04-0AB0
- Type
- PLC CPU
- Application
- PLC controller with integrated I/O
- Used with
- SIMATIC S7-300 rack (S7-300 backplane bus)
- Product type designation
- CPU 313C
- HW functional status
- 01
- Firmware version
- V3.3
- Engineering with / Programming package
- STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
- Supply voltage / Rated value (DC)
- 24 V
- Supply voltage / permissible range, lower limit (DC)
- 19.2 V
- Supply voltage / permissible range, upper limit (DC)
- 28.8 V
- external protection for power supply lines (recommendation)
- Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A
- Mains buffering / Mains/voltage failure stored energy time
- 5 ms
- Mains buffering / Repeat rate, min.
- 1 s
- Load voltage L+ / Digital inputs / Rated value (DC)
- 24 V
- Load voltage L+ / Digital inputs / Reverse polarity protection
- Yes
- Load voltage L+ / Digital outputs / Rated value (DC)
- 24 V
- Load voltage L+ / Digital outputs / Reverse polarity protection
- No
- Input current / Current consumption (rated value)
- 650 mA
- Input current / Current consumption (in no-load operation), typ.
- 150 mA
- Input current / Inrush current, typ.
- 5 A
- Input current / I²t
- 0.7 A²·s
- Digital inputs / from load voltage L+ (without load), max.
- 80 mA
- Digital outputs / from load voltage L+, max.
- 50 mA
- Power loss, typ.
- 12 W
- Work memory / integrated
- 128 kbyte
- Work memory / expandable
- No
- Load memory / Plug-in (MMC)
- Yes
- Load memory / Plug-in (MMC), max.
- 8 Mbyte
Show all 364 specificationsShow fewer
- Load memory / Data management on MMC (after last programming), min.
- 10 a
- Backup / present
- Yes; Guaranteed by MMC (maintenance-free)
- Backup / without battery
- Yes; Program and data
- CPU processing times / for bit operations, typ.
- 0.07 µs
- CPU processing times / for word operations, typ.
- 0.15 µs
- CPU processing times / for fixed point arithmetic, typ.
- 0.2 µs
- CPU processing times / for floating point arithmetic, typ.
- 0.72 µs
- CPU-blocks / Number of elements (total)
- 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
- DB / Number, max.
- 1 024; Number range: 1 to 16000
- DB / Size, max.
- 64 kbyte
- FB / Number, max.
- 1 024; Number range: 0 to 7999
- FB / Size, max.
- 64 kbyte
- FC / Number, max.
- 1 024; Number range: 0 to 7999
- FC / Size, max.
- 64 kbyte
- OB / Number, max.
- see instruction list
- OB / Size, max.
- 64 kbyte
- OB / Number of free cycle OBs
- 1; OB 1
- OB / Number of time alarm OBs
- 1; OB 10
- OB / Number of delay alarm OBs
- 2; OB 20, 21
- OB / Number of cyclic interrupt OBs
- 4; OB 32, 33, 34, 35
- OB / Number of process alarm OBs
- 1; OB 40
- OB / Number of startup OBs
- 1; OB 100
- OB / Number of asynchronous error OBs
- 4; OB 80, 82, 85, 87
- OB / Number of synchronous error OBs
- 2; OB 121, 122
- Nesting depth / per priority class
- 16
- Nesting depth / additional within an error OB
- 4
- S7 counter / Number
- 256
- S7 counter / Retentivity / adjustable
- Yes
- S7 counter / Retentivity / preset
- Z 0 to Z 7
- S7 counter / Counting range / lower limit
- 0
- S7 counter / Counting range / upper limit
- 999
- IEC counter / present
- Yes
- IEC counter / Type
- SFB
- IEC counter / Number
- Unlimited (limited only by RAM capacity)
- S7 timer / Number
- 256
- S7 timer / Retentivity / adjustable
- Yes
- S7 timer / Retentivity / preset
- No retentivity
- S7 timer / Time range / lower limit
- 10 ms
- S7 timer / Time range / upper limit
- 9 990 s
- IEC timer / present
- Yes
- IEC timer / Type
- SFB
- IEC timer / Number
- Unlimited (limited only by RAM capacity)
- Retentive data area (incl. timers, counters, flags), max.
- 64 kbyte
- Flag / Size, max.
- 256 byte
- Flag / Retentivity available
- Yes; MB 0 to MB 255
- Flag / Retentivity preset
- MB 0 to MB 15
- Flag / Number of clock memories
- 8; 1 memory byte
- Data blocks / Retentivity adjustable
- Yes; via non-retain property on DB
- Data blocks / Retentivity preset
- Yes
- Local data / per priority class, max.
- 32 kbyte; Max. 2048 bytes per block
- I/O address area / Inputs
- 1 024 byte
- I/O address area / Outputs
- 1 024 byte
- I/O address area / of which distributed / Inputs
- none
- I/O address area / of which distributed / Outputs
- none
- Process image / Inputs
- 1 024 byte
- Process image / Outputs
- 1 024 byte
- Process image / Inputs, adjustable
- 1 024 byte
- Process image / Outputs, adjustable
- 1 024 byte
- Process image / Inputs, default
- 128 byte
- Process image / Outputs, default
- 128 byte
- Digital channels / Inputs
- 1 016
- Digital channels / of which central
- 1 016
- Digital channels / Outputs
- 1 008
- Digital channels / of which central
- 1 008
- Analog channels / Inputs
- 253
- Analog channels / of which central
- 253
- Analog channels / Outputs
- 250
- Analog channels / of which central
- 250
- Hardware configuration / Number of expansion units, max.
- 3
- Number of DP masters / integrated
- none
- Number of DP masters / via CP
- 4
- Number of operable FMs and CPs (recommended) / FM
- 8
- Number of operable FMs and CPs (recommended) / CP, PtP
- 8
- Number of operable FMs and CPs (recommended) / CP, LAN
- 6
- Rack / Racks, max.
- 4
- Rack / Modules per rack, max.
- 8; In rack 3 max. 7
- Clock / Hardware clock (real-time)
- Yes
- Clock / retentive and synchronizable
- Yes
- Clock / Backup time
- 6 wk; At 40 °C ambient temperature
- Clock / Deviation per day, max.
- 10 s; Typ.: 2 s
- Clock / Behavior of the clock following POWER-ON
- Clock continues running after POWER OFF
- Clock / Behavior of the clock following expiry of backup period
- the clock continues at the time of day it had when power was switched off
- Operating hours counter / Number
- 1
- Operating hours counter / Number/Number range
- 0
- Operating hours counter / Range of values
- 0 to 2^31 hours (when using SFC 101)
- Operating hours counter / Granularity
- 1 h
- Operating hours counter / retentive
- Yes; Must be restarted at each restart
- Clock synchronization / supported
- Yes
- Clock synchronization / to MPI, master
- Yes
- Clock synchronization / on MPI, device
- Yes
- Clock synchronization / in AS, master
- Yes
- Clock synchronization / in AS, device
- No
- Number of digital inputs
- 24
- Digital inputs / of which inputs usable for technological functions
- 12
- Digital inputs / integrated channels (DI)
- 24
- Digital inputs / Input characteristic curve in accordance with IEC 61131, type 1
- Yes
- Number of simultaneously controllable inputs / horizontal installation / up to 40 °C, max.
- 24
- Number of simultaneously controllable inputs / horizontal installation / up to 60 °C, max.
- 12
- Number of simultaneously controllable inputs / vertical installation / up to 40 °C, max.
- 12
- Input voltage / Rated value (DC)
- 24 V
- Input voltage / for signal "0"
- -3 to +5V
- Input voltage / for signal "1"
- +15 to +30 V
- Input current / for signal "1", typ.
- 8 mA
- Input delay (for rated value of input voltage) / for standard inputs / parameterizable
- Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)
- Input delay (for rated value of input voltage) / for standard inputs / Rated value
- 3 ms
- Input delay (for rated value of input voltage) / for technological functions / at "0" to "1", max.
- 16 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency
- Cable length / shielded, max.
- 1 000 m; 100 m for technological functions
- Cable length / unshielded, max.
- 600 m; for technological functions: No
- Cable length / for technological functions / shielded, max.
- 100 m; at maximum count frequency
- Cable length / for technological functions / unshielded, max.
- not allowed
- Number of digital outputs
- 16
- Digital outputs / of which high-speed outputs
- 4; Notice: You cannot connect the fast outputs of your CPU in parallel
- Digital outputs / integrated channels (DO)
- 16
- Digital outputs / Short-circuit protection
- Yes; Clocked electronically
- Digital outputs / Response threshold, typ.
- 1 A
- Digital outputs / Limitation of inductive shutdown voltage to
- L+ (-48 V)
- Controlling a digital input
- Yes
- Switching capacity of the outputs / on lamp load, max.
- 5 W
- Load resistance range / lower limit
- 48 Ω
- Load resistance range / upper limit
- 4 kΩ
- Output voltage / for signal "1", min.
- L+ (-0.8 V)
- Output current / for signal "1" rated value
- 500 mA
- Output current / for signal "1" permissible range, min.
- 5 mA
- Output current / for signal "1" permissible range, max.
- 0.6 A
- Output current / for signal "1" minimum load current
- 5 mA
- Output current / for signal "0" residual current, max.
- 0.5 mA
- Parallel switching of two outputs / for uprating
- No
- Parallel switching of two outputs / for redundant control of a load
- Yes
- Switching frequency / with resistive load, max.
- 100 Hz
- Switching frequency / with inductive load, max.
- 0.5 Hz
- Switching frequency / on lamp load, max.
- 100 Hz
- Switching frequency / of the pulse outputs, with resistive load, max.
- 2.5 kHz
- Total current of the outputs (per group) / horizontal installation / up to 40 °C, max.
- 3 A
- Total current of the outputs (per group) / horizontal installation / up to 60 °C, max.
- 2 A
- Total current of the outputs (per group) / vertical installation / up to 40 °C, max.
- 2 A
- Cable length / shielded, max.
- 1 000 m
- Cable length / unshielded, max.
- 600 m
- Number of analog inputs
- 4
- Analog inputs / For voltage/current measurement
- 4
- Analog inputs / For resistance/resistance thermometer measurement
- 1
- Analog inputs / integrated channels (AI)
- 5; 4x current/voltage, 1x resistance
- Analog inputs / permissible input voltage for current input (destruction limit), max.
- 5 V; Permanent
- Analog inputs / permissible input voltage for voltage input (destruction limit), max.
- 30 V; Permanent
- Analog inputs / permissible input current for voltage input (destruction limit), max.
- 0.5 mA; Permanent
- Analog inputs / permissible input current for current input (destruction limit), max.
- 50 mA; Permanent
- Analog inputs / Electrical input frequency, max.
- 400 Hz
- Analog inputs / No-load voltage for resistance-type transmitter, typ.
- 3.3 V
- Analog inputs / Constant measurement current for resistance-type transmitter, typ.
- 1.25 mA
- Analog inputs / Technical unit for temperature measurement adjustable
- Yes; Degrees Celsius / degrees Fahrenheit / Kelvin
- Input ranges / Voltage
- Yes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ
- Input ranges / Current
- Yes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω
- Input ranges / Resistance thermometer
- Yes; Pt 100 / 10 MΩ
- Input ranges / Resistance
- Yes; 0 Ω to 600 Ω / 10 MΩ
- Input ranges (rated values), voltages / 0 to +10 V
- Yes
- Input ranges (rated values), voltages / Input resistance (0 to 10 V)
- 100 kΩ
- Input ranges (rated values), currents / 0 to 20 mA
- Yes
- Input ranges (rated values), currents / Input resistance (0 to 20 mA)
- 100 Ω
- Input ranges (rated values), currents / -20 mA to +20 mA
- Yes
- Input ranges (rated values), currents / Input resistance (-20 mA to +20 mA)
- 100 Ω
- Input ranges (rated values), currents / 4 mA to 20 mA
- Yes
- Input ranges (rated values), currents / Input resistance (4 mA to 20 mA)
- 100 Ω
- Input ranges (rated values), resistance thermometer / Pt 100
- Yes
- Input ranges (rated values), resistance thermometer / Input resistance (Pt 100)
- 10 MΩ
- Input ranges (rated values), resistors / 0 to 600 ohms
- Yes
- Input ranges (rated values), resistors / Input resistance (0 to 600 ohms)
- 10 MΩ
- Thermocouple (TC) / Temperature compensation / Parameterizable
- No
- Characteristic linearization / Parameterizable
- Yes; by software
- Characteristic linearization / for resistance thermometer
- Pt 100
- Cable length / shielded, max.
- 100 m
- Analog outputs / integrated channels (AO)
- 2
- Analog outputs / Voltage output, short-circuit protection
- Yes
- Analog outputs / Voltage output, short-circuit current, max.
- 55 mA
- Analog outputs / Current output, no-load voltage, max.
- 14 V
- Output ranges, voltage / 0 to 10 V
- Yes
- Output ranges, voltage / -10 V to +10 V
- Yes
- Output ranges, current / 0 to 20 mA
- Yes
- Output ranges, current / -20 mA to +20 mA
- Yes
- Output ranges, current / 4 mA to 20 mA
- Yes
- Connection of actuators / for voltage output two-wire connection
- Yes; Without compensation of the line resistances
- Connection of actuators / for voltage output four-wire connection
- No
- Connection of actuators / for current output two-wire connection
- Yes
- Load impedance (in rated range of output) / with voltage outputs, min.
- 1 kΩ
- Load impedance (in rated range of output) / with voltage outputs, capacitive load, max.
- 0.1 µF
- Load impedance (in rated range of output) / with current outputs, max.
- 300 Ω
- Load impedance (in rated range of output) / with current outputs, inductive load, max.
- 0.1 mH
- Destruction limits against externally applied voltages and currents / Voltages at the outputs towards MANA
- 16 V; Permanent
- Destruction limits against externally applied voltages and currents / Current, max.
- 50 mA; Permanent
- Cable length / shielded, max.
- 200 m
- Analog value generation for the inputs / Measurement principle
- Actual value encryption (successive approximation)
- Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.
- 12 bit
- Integration and conversion time/resolution per channel / Integration time, parameterizable
- Yes; 16.6 / 20 ms
- Integration and conversion time/resolution per channel / Interference voltage suppression for interference frequency f1 in Hz
- 50 / 60 Hz
- Integration and conversion time/resolution per channel / Time constant of the input filter
- 0.38 ms
- Integration and conversion time/resolution per channel / Basic execution time of the module (all channels released)
- 1 ms
- Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.
- 12 bit
- Integration and conversion time/resolution per channel / Conversion time (per channel)
- 1 ms
- Settling time / for resistive load
- 0.6 ms
- Settling time / for capacitive load
- 1 ms
- Settling time / for inductive load
- 0.5 ms
- Connection of signal encoders / for voltage measurement
- Yes
- Connection of signal encoders / for current measurement as 2-wire transducer
- Yes; with external supply
- Connection of signal encoders / for current measurement as 4-wire transducer
- Yes
- Connection of signal encoders / for resistance measurement with two-wire connection
- Yes; Without compensation of the line resistances
- Connection of signal encoders / for resistance measurement with three-wire connection
- No
- Connection of signal encoders / for resistance measurement with four-wire connection
- No
- Connectable encoders / 2-wire sensor
- Yes
- Connectable encoders / permissible quiescent current (2-wire sensor), max.
- 1.5 mA
- Errors/accuracies / Temperature error (relative to input range), (+/-)
- 0.006 %/K
- Errors/accuracies / Crosstalk between the inputs, min.
- 60 dB
- Errors/accuracies / Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)
- 0.06 %
- Errors/accuracies / Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)
- 0.1 %
- Errors/accuracies / Linearity error (relative to output range), (+/-)
- 0.15 %
- Errors/accuracies / Temperature error (relative to output range), (+/-)
- 0.01 %/K
- Errors/accuracies / Crosstalk between the outputs, min.
- 60 dB
- Errors/accuracies / Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)
- 0.06 %
- Operational error limit in overall temperature range / Voltage, relative to input range, (+/-)
- 1 %
- Operational error limit in overall temperature range / Current, relative to input range, (+/-)
- 1 %
- Operational error limit in overall temperature range / Resistance, relative to input range, (+/-)
- 1 %
- Operational error limit in overall temperature range / Voltage, relative to output range, (+/-)
- 1 %
- Operational error limit in overall temperature range / Current, relative to output range, (+/-)
- 1 %
- Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-)
- 0.8 %; Linearity error ±0.06 %
- Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-)
- 0.8 %; Linearity error ±0.06 %
- Basic error limit (operational limit at 25 °C) / Resistance, relative to input range, (+/-)
- 0.8 %; Linearity error ±0.2 %
- Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-)
- 0.8 %
- Basic error limit (operational limit at 25 °C) / Voltage, relative to output range, (+/-)
- 0.8 %
- Basic error limit (operational limit at 25 °C) / Current, relative to output range, (+/-)
- 0.8 %
- Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency / Series mode interference (peak value of interference < rated value of input range), min.
- 30 dB
- Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency / Common mode interference, min.
- 40 dB
- Number of PROFINET interfaces
- 0
- Number of RS 485 interfaces
- 1; MPI
- Number of RS 422 interfaces
- 0
- 1. Interface / Interface type
- Integrated RS 485 interface
- 1. Interface / Isolated
- No
- Interface types / RS 485
- Yes
- Interface types / Output current of the interface, max.
- 200 mA
- Protocols / MPI
- Yes
- Protocols / PROFIBUS DP master
- No
- Protocols / PROFIBUS DP device
- No
- Protocols / Point-to-point connection
- No
- MPI / Transmission rate, max.
- 187.5 kbit/s
- MPI / Services / PG/OP communication
- Yes
- MPI / Services / Routing
- No
- MPI / Services / Global data communication
- Yes
- MPI / Services / S7 basic communication
- Yes
- MPI / Services / S7 communication
- Yes; Only server, configured on one side
- MPI / Services / S7 communication, as client
- No; but via CP and loadable FB
- MPI / Services / S7 communication, as server
- Yes
- Protocols / PROFIsafe
- No
- PG/OP communication
- Yes
- Communication functions / Data record routing
- No
- Global data communication / supported
- Yes
- Global data communication / Number of GD loops, max.
- 8
- Global data communication / Number of GD packets, max.
- 8
- Global data communication / Number of GD packets, transmitter, max.
- 8
- Global data communication / Number of GD packets, receiver, max.
- 8
- Global data communication / Size of GD packets, max.
- 22 byte
- Global data communication / Size of GD packet (of which consistent), max.
- 22 byte
- S7 basic communication / supported
- Yes
- S7 basic communication / User data per job, max.
- 76 byte
- S7 basic communication / User data per job (of which consistent), max.
- 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
- S7 communication / supported
- Yes
- S7 communication / as server
- Yes
- S7 communication / as client
- Yes; Via CP and loadable FB
- S7 communication / User data per job, max.
- 180 byte; With PUT/GET
- S7 communication / User data per job (of which consistent), max.
- 240 byte; as server
- S5 compatible communication / supported
- Yes; via CP and loadable FC
- Number of connections / overall
- 8
- Number of connections / usable for PG communication
- 7
- Number of connections / reserved for PG communication
- 1
- Number of connections / adjustable for PG communication, min.
- 1
- Number of connections / adjustable for PG communication, max.
- 7
- Number of connections / usable for OP communication
- 7
- Number of connections / reserved for OP communication
- 1
- Number of connections / adjustable for OP communication, min.
- 1
- Number of connections / adjustable for OP communication, max.
- 7
- Number of connections / usable for S7 basic communication
- 4
- Number of connections / reserved for S7 basic communication
- 0
- Number of connections / adjustable for S7 basic communication, min.
- 0
- Number of connections / adjustable for S7 basic communication, max.
- 4
- S7 message functions / Number of login stations for message functions, max.
- 8; Depending on the configured connections for PG/OP and S7 basic communication
- S7 message functions / Process diagnostic messages
- Yes
- S7 message functions / simultaneously active Alarm_S blocks, max.
- 300
- Test commissioning functions / Status block
- Yes; Up to 2 simultaneously
- Test commissioning functions / Single step
- Yes
- Test commissioning functions / Number of breakpoints
- 4
- Status/control / Status/control variable
- Yes
- Status/control / Variables
- Inputs, outputs, memory bits, DB, times, counters
- Status/control / Number of variables, max.
- 30
- Status/control / of which status variables, max.
- 30
- Status/control / of which control variables, max.
- 14
- Forcing / Forcing
- Yes
- Forcing / Forcing, variables
- Inputs, outputs
- Forcing / Number of variables, max.
- 10
- Diagnostic buffer / present
- Yes
- Diagnostic buffer / Number of entries, max.
- 500
- Diagnostic buffer / can be set
- No
- Diagnostic buffer / of which powerfail-proof
- 100; Only the last 100 entries are retained
- Diagnostic buffer / Number of entries readable in RUN, max.
- 499
- Diagnostic buffer / can be set
- Yes; From 10 to 499
- Diagnostic buffer / preset
- 10
- Service data / Can be read out
- Yes
- Diagnostics indication LED / Status indicator digital input (green)
- Yes
- Diagnostics indication LED / Status indicator digital output (green)
- Yes
- Counter / Number of counters
- 3; See "Technological Functions" manual
- Counter / Counting frequency, max.
- 30 kHz
- Integrated Functions / Frequency measurement
- Yes
- Integrated Functions / Number of frequency meters
- 3; up to 30 kHz (see "Technological Functions" manual)
- Integrated Functions / controlled positioning
- No
- integrated function blocks (closed-loop control)
- Yes; PID controller (see "Technological Functions" manual)
- Integrated Functions / PID controller
- Yes
- Integrated Functions / Number of pulse outputs
- 3; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual)
- Integrated Functions / Limit frequency (pulse)
- 2.5 kHz
- Potential separation digital inputs / Potential separation digital inputs
- Yes
- Potential separation digital inputs / between the channels
- No
- Potential separation digital inputs / between the channels and backplane bus
- Yes
- Potential separation digital outputs / Potential separation digital outputs
- Yes
- Potential separation digital outputs / between the channels
- Yes
- Potential separation digital outputs / between the channels, in groups of
- 8
- Potential separation digital outputs / between the channels and backplane bus
- Yes
- Potential separation analog inputs / Potential separation analog inputs
- Yes; common for analog I/O
- Potential separation analog inputs / between the channels
- No
- Potential separation analog inputs / between the channels and backplane bus
- Yes
- Potential separation analog outputs / Potential separation analog outputs
- Yes; common for analog I/O
- Potential separation analog outputs / between the channels
- No
- Potential separation analog outputs / between the channels and backplane bus
- Yes
- Isolation tested with
- 600 V DC
- Ambient temperature during operation / min.
- 0 °C
- Ambient temperature during operation / max.
- 60 °C
- Configuration software / STEP 7
- Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
- Configuration software / STEP 7 Lite
- No
- Programming / Command set
- see instruction list
- Programming / Nesting levels
- 8
- Programming / System functions (SFC)
- see instruction list
- Programming / System function blocks (SFB)
- see instruction list
Technical documents (1)
Key features
- 128 KB integrated work memory
- Integrated I/O: 24 DI, 16 DO, 4 AI, 2 AO and 1 Pt100 input
- 3 high-speed counters (30 kHz)
- MPI interface
- Needs two 40-pole front connectors and a Micro Memory Card
- Discontinued by Siemens on 1 October 2025; spare part only
About the Siemens 6ES7313-5BG04-0AB0
The Siemens 6ES7313-5BG04-0AB0 is the CPU 313C, a compact S7-300 CPU with its I/O on board. Siemens's data sheet lists 128 KB of work memory, an MPI interface, 24 digital inputs and 16 digital outputs, four analog inputs plus one Pt100 input, two analog outputs and three high-speed counters up to 30 kHz, on 24 V DC. It needs two 40-pole front connectors and a Micro Memory Card, ordered separately. Siemens's data sheet marks it as a spare part. Siemens names no direct successor for the order number; its route forward is migration to the S7-1500.
What is the 6ES7313-5BG04-0AB0 used for?
It controls small machines where the on-board I/O is enough and MPI covers programming and panels. A failed 313C takes its own I/O down with it.
Lifecycle and successor
Discontinued: product cancellation (Siemens SiePortal), spare part only.
Before you order
What to photograph or confirm so the right unit is quoted.
Check the full order number and the firmware version on the CPU's label, and read the program size from the project if you can: a replacement must match or exceed the work memory. The Micro Memory Card (MMC) holding the program is a separate part; send its order number and size too. The two front connectors carry the field wiring and can usually be moved to the replacement unit.
Alternatives for 6ES7313-5BG04-0AB0
The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.
| Product | Manufacturer | Type | Lifecycle | Relationship | Qty Available | Price | Action |
|---|---|---|---|---|---|---|---|
| Siemens 6ES7315-2AH14-0AB0CPU 315-2 DP, 256 KB, MPI and PROFIBUS DP | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7315-2EH14-0AB0CPU 315-2 PN/DP, 384 KB, MPI/DP and PROFINET | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7317-2EK14-0AB0CPU 317-2 PN/DP, 1 MB, MPI/DP and PROFINET | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7314-6EH04-0AB0CPU 314C-2 PN/DP compact CPU with integrated I/O | Siemens | PLC CPU | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7321-1BL00-0AA0SM 321 digital input, 32 DI, 24 V DC | Siemens | Digital input module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7322-1BL00-0AA0SM 322 digital output, 32 DO, 24 V DC, 0.5 A | Siemens | Digital output module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7331-7KF02-0AB0SM 331 analog input, 8 AI, U/I/thermocouple/resistance | Siemens | Analog input module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7332-5HF00-0AB0SM 332 analog output, 8 AO, voltage/current | Siemens | Analog output module | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6ES7307-1EA01-0AA0PS307 power supply, 120/230 V AC in, 24 V DC 5 A out | Siemens | Power supply | Phase-out announced (Siemens SiePortal) | Same family | On Request | On request | View › |
| Siemens 6GK7343-1CX10-0XE0CP 343-1 Lean communications processor, Industrial Ethernet | Siemens | Communications processor | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6GK7343-1EX30-0XE0CP 343-1 communications processor, Industrial Ethernet, PROFINET IO controller | Siemens | Communications processor | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
| Siemens 6GK7342-5DA03-0XE0CP 342-5 communications processor, PROFIBUS DP master/slave | Siemens | Communications processor | Discontinued: product cancellation (Siemens SiePortal), spare part only | Same family | On Request | On request | View › |
You may also be interested in
Siemens
Siemens 6ES7972-0BA12-0XA0
View ›Siemens
Siemens 6ES7972-0BB12-0XA0
View ›Siemens
Siemens 6ES7972-0BA42-0XA0
View ›Siemens
Siemens 6ES7972-0BB42-0XA0
View ›Siemens
Siemens 6ES7972-0BA52-0XA0
View ›Siemens
Siemens 6ES7972-0BB52-0XA0
View ›Siemens
Siemens 6ES7972-0BA61-0XA0
View ›Siemens
Siemens 6ES7972-0BA70-0XA0
View ›Siemens
Siemens 6GK1500-0FC10
View ›Siemens
Siemens 6GK1901-1BB10-2AA0
View ›Siemens
Siemens 6GK1901-1BB11-2AA0
View ›Siemens
Siemens 6XV1830-0EH10
View ›
TIMC is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorisation or affiliation.