Skip to content

Siemens 6ES7315-2FJ14-0AB0

CPU 315F-2 PN/DP fail-safe, 512 KB, MPI/DP and PROFINET

Request a quote
Siemens
Siemens 6ES7315-2FJ14-0AB0 CPU 315F-2 PN/DP fail-safe, photo from Siemens data sheet 6ES7315-2FJ14-0AB0

Image is for illustrative purposes only. Please refer to product description.

  • FedEx
  • DHL
  • UPS
Manufacturer
Siemens
Manufacturer part number
6ES7315-2FJ14-0AB0
Technical datasheet
Data sheet

Specifications

AttributeValue
TypeSafety PLC CPU (F-CPU)
Manufacturer lifecycleDiscontinued
Product type designationCPU 315F-2 PN/DP
HW functional status01
Firmware versionV3.2
Product function / Isochronous modeYes; Via PROFIBUS DP or PROFINET interface
Engineering with / Programming packageSTEP 7 V5.5 or higher, Distributed Safety V5.4 SP4
Supply voltage / Rated value (DC)24 V
Supply voltage / permissible range, lower limit (DC)20.4 V
Supply voltage / permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Mains buffering / Mains/voltage failure stored energy time5 ms
Mains buffering / Repeat rate, min.1 s
Input current / Current consumption (rated value)750 mA
Input current / Current consumption (in no-load operation), typ.150 mA
Show all 358 specifications
Input current / Inrush current, typ.4 A
Input current / I²t1 A²·s
Power loss, typ.4.65 W
Work memory / integrated512 kbyte
Work memory / expandableNo
Load memory / Plug-in (MMC)Yes
Load memory / Plug-in (MMC), max.8 Mbyte
Load memory / Data management on MMC (after last programming), min.10 a
Backup / presentYes; Guaranteed by MMC (maintenance-free)
Backup / without batteryYes; Program and data
CPU processing times / for bit operations, typ.0.05 µs
CPU processing times / for word operations, typ.0.09 µs
CPU processing times / for fixed point arithmetic, typ.0.12 µs
CPU processing times / for floating point arithmetic, typ.0.45 µs
CPU-blocks / Number of elements (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB / Number, max.1 024; Number range: 1 to 16000
DB / Size, max.64 kbyte
FB / Number, max.1 024; Number range: 0 to 7999
FB / Size, max.64 kbyte
FC / Number, max.1 024; Number range: 0 to 7999
FC / Size, max.64 kbyte
OB / Size, max.64 kbyte
OB / Number of free cycle OBs1; OB 1
OB / Number of time alarm OBs1; OB 10
OB / Number of delay alarm OBs2; OB 20, 21
OB / Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
OB / Number of process alarm OBs1; OB 40
OB / Number of DPV1 alarm OBs3; OB 55, 56, 57
OB / Number of isochronous mode OBs1; OB 61
OB / Number of startup OBs1; OB 100
OB / Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
OB / Number of synchronous error OBs2; OB 121, 122
Nesting depth / per priority class16
Nesting depth / additional within an error OB4
S7 counter / Number256
S7 counter / Retentivity / adjustableYes
S7 counter / Retentivity / presetZ 0 to Z 7
S7 counter / Counting range / can be setYes
S7 counter / Counting range / lower limit0
S7 counter / Counting range / upper limit999
IEC counter / presentYes
IEC counter / TypeSFB
IEC counter / NumberUnlimited (limited only by RAM capacity)
S7 timer / Number256
S7 timer / Retentivity / adjustableYes
S7 timer / Retentivity / presetNo retentivity
S7 timer / Time range / lower limit10 ms
S7 timer / Time range / upper limit9 990 s
IEC timer / presentYes
IEC timer / TypeSFB
IEC timer / NumberUnlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.128 kbyte
Flag / Size, max.2 048 byte
Flag / Retentivity availableYes; MB 0 to MB 2 047
Flag / Retentivity presetMB 0 to MB 15
Flag / Number of clock memories8; 1 memory byte
Data blocks / Retentivity adjustableYes; via non-retain property on DB
Data blocks / Retentivity presetYes
Local data / per priority class, max.32 768 byte; Max. 2048 bytes per block
I/O address area / Inputs2 048 byte
I/O address area / Outputs2 048 byte
I/O address area / of which distributed / Inputs2 048 byte
I/O address area / of which distributed / Outputs2 048 byte
Process image / Inputs2 048 byte
Process image / Outputs2 048 byte
Process image / Inputs, adjustable2 048 byte
Process image / Outputs, adjustable2 048 byte
Process image / Inputs, default128 byte
Process image / Outputs, default128 byte
Subprocess images / Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels / Inputs16 384
Digital channels / Inputs / of which central1 024
Digital channels / Outputs16 384
Digital channels / Outputs / of which central1 024
Analog channels / Inputs1 024
Analog channels / Inputs / of which central256
Analog channels / Outputs1 024
Analog channels / Outputs / of which central256
Hardware configuration / Number of expansion units, max.3
Number of DP masters / integrated1
Number of DP masters / via CP4
Number of operable FMs and CPs (recommended) / FM8
Number of operable FMs and CPs (recommended) / CP, PtP8
Number of operable FMs and CPs (recommended) / CP, LAN10
Rack / Racks, max.4
Rack / Modules per rack, max.8
Clock / Hardware clock (real-time)Yes
Clock / retentive and synchronizableYes
Clock / Backup time6 wk; At 40 °C ambient temperature
Clock / Deviation per day, max.10 s; Typ.: 2 s
Clock / Behavior of the clock following POWER-ONClock continues running after POWER OFF
Clock / Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Operating hours counter / Number1
Operating hours counter / Number/Number range0
Operating hours counter / Range of values0 to 2^31 hours (when using SFC 101)
Operating hours counter / Granularity1 h
Operating hours counter / retentiveYes; Must be restarted at each restart
Clock synchronization / supportedYes
Clock synchronization / to MPI, masterYes
Clock synchronization / on MPI, deviceYes
Clock synchronization / to DP, masterYes; With DP slave only slave clock
Clock synchronization / on DP, deviceYes
Clock synchronization / in AS, masterYes
Clock synchronization / in AS, deviceYes
Clock synchronization / on Ethernet via NTPYes; As client
Number of digital inputs0
Number of digital outputs0
Number of analog inputs0
Number of PROFINET interfaces1
Number of RS 485 interfaces1
Number of RS 422 interfaces0
1. Interface / Interface typeIntegrated RS 485 interface
1. Interface / IsolatedYes
Interface types / RS 485Yes
Interface types / Output current of the interface, max.200 mA
1. Interface / Protocols / MPIYes
1. Interface / Protocols / PROFIBUS DP masterYes
1. Interface / Protocols / PROFIBUS DP deviceYes
Protocols / Point-to-point connectionNo
MPI / Transmission rate, max.12 Mbit/s
MPI / Services / PG/OP communicationYes
MPI / Services / RoutingYes
MPI / Services / Global data communicationYes
MPI / Services / S7 basic communicationYes
MPI / Services / S7 communicationYes
MPI / Services / S7 communication, as clientNo; but via CP and loadable FB
MPI / Services / S7 communication, as serverYes
PROFIBUS DP master / Transmission rate, max.12 Mbit/s
PROFIBUS DP master / max. number of DP devices124
PROFIBUS DP master / Services / PG/OP communicationYes
PROFIBUS DP master / Services / RoutingYes
PROFIBUS DP master / Services / Global data communicationNo
PROFIBUS DP master / Services / S7 basic communicationYes; I blocks only
PROFIBUS DP master / Services / S7 communicationYes
PROFIBUS DP master / Services / S7 communication, as clientNo
PROFIBUS DP master / Services / S7 communication, as serverYes
PROFIBUS DP master / Services / EquidistanceYes
PROFIBUS DP master / Services / Isochronous modeYes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
PROFIBUS DP master / Services / SYNC/FREEZEYes
PROFIBUS DP master / Services / activation/deactivation of DP devicesYes
PROFIBUS DP master / Services / max. number of DP devices that can be activated/deactivated at the same time8
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)Yes; as subscriber
PROFIBUS DP master / Services / DPV1Yes
PROFIBUS DP master / Address area / Inputs, max.2 kbyte
PROFIBUS DP master / Address area / Outputs, max.2 kbyte
PROFIBUS DP master / User data per DP device / Inputs, max.244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.244 byte
PROFIBUS DP device / Transmission rate, max.12 Mbit/s
PROFIBUS DP device / automatic baud rate searchYes; only with passive interface
PROFIBUS DP device / Address area, max.32
PROFIBUS DP device / User data per address area, max.32 byte
PROFIBUS DP device / Services / PG/OP communicationYes
PROFIBUS DP device / Services / RoutingYes; Only with active interface
PROFIBUS DP device / Services / Global data communicationNo
PROFIBUS DP device / Services / S7 basic communicationNo
PROFIBUS DP device / Services / S7 communicationYes
PROFIBUS DP device / Services / S7 communication, as clientNo
PROFIBUS DP device / Services / S7 communication, as serverYes; Connection configured on one side only
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)Yes
PROFIBUS DP device / Services / DPV1No
PROFIBUS DP device / Transfer memory / Inputs244 byte
PROFIBUS DP device / Transfer memory / Outputs244 byte
2. Interface / Interface typePROFINET
2. Interface / IsolatedYes
2. Interface / automatic detection of transmission rateYes; 10/100 Mbit/s
2. Interface / AutonegotiationYes
2. Interface / AutocrossingYes
2. Interface / Change of IP address at runtime, supportedYes
Interface types / RJ 45 (Ethernet)Yes
Interface types / Number of ports2
Interface types / integrated switchYes
2. Interface / Protocols / MPINo
Protocols / PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
Protocols / PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
Protocols / PROFINET CBAYes
2. Interface / Protocols / PROFIBUS DP masterNo
2. Interface / Protocols / PROFIBUS DP deviceNo
Protocols / Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Protocols / Web serverYes; only read function
Protocols / Media redundancyYes
PROFINET IO Controller / Transmission rate, max.100 Mbit/s
PROFINET IO Controller / Services / PG/OP communicationYes
PROFINET IO Controller / Services / RoutingYes
PROFINET IO Controller / Services / S7 communicationYes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
PROFINET IO Controller / Services / Isochronous modeYes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
PROFINET IO Controller / Services / IRTYes
PROFINET IO Controller / Services / Shared deviceYes
PROFINET IO Controller / Services / Prioritized startupYes
PROFINET IO Controller / Services / Number of IO devices with prioritized startup, max.32
PROFINET IO Controller / Services / Number of connectable IO Devices, max.128
PROFINET IO Controller / Services / Of which IO devices with IRT, max.64
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices, max. / Of which IO devices with IRT, max. / of which in line, max.64
PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility"128
2. Interface / PROFINET IO Controller / Services / Number of IO Devices with IRT and the option "high flexibility" / of which in line, max.61
PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max.128
2. Interface / PROFINET IO Controller / Services / Number of connectable IO Devices for RT, max. / of which in line, max.128
PROFINET IO Controller / Services / Activation/deactivation of IO DevicesYes
PROFINET IO Controller / Services / Number of IO Devices that can be simultaneously activated/deactivated, max.8
PROFINET IO Controller / Services / IO Devices changing during operation (partner ports), supportedYes
PROFINET IO Controller / Services / Number of IO Devices per tool, max.8
PROFINET IO Controller / Services / Device replacement without swap mediumYes
PROFINET IO Controller / Services / Send cycles250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
PROFINET IO Controller / Services / Updating time250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details)
PROFINET IO Controller / Address area / Inputs, max.2 kbyte
PROFINET IO Controller / Address area / Outputs, max.2 kbyte
PROFINET IO Controller / Address area / User data consistency, max.1 024 byte
PROFINET IO Device / Services / PG/OP communicationYes
PROFINET IO Device / Services / RoutingYes
PROFINET IO Device / Services / S7 communicationYes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
PROFINET IO Device / Services / Isochronous modeNo
PROFINET IO Device / Services / IRTYes
PROFINET IO Device / Services / PROFIenergyYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I- Device
PROFINET IO Device / Services / Shared deviceYes
PROFINET IO Device / Services / Number of IO Controllers with shared device, max.2
PROFINET IO Device / Transfer memory / Inputs, max.1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Transfer memory / Outputs, max.1 440 byte; Per IO Controller with shared device
PROFINET IO Device / Submodules / Number, max.64
PROFINET IO Device / Submodules / User data per submodule, max.1 024 byte
PROFINET CBA / acyclic transmissionYes
PROFINET CBA / cyclic transmissionYes
Open IE communication / Number of connections, max.8
Open IE communication / Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Open IE communication / Keep-alive function, supportedYes
Protocols / PROFIsafeYes
Redundancy mode / Media redundancy / Switchover time on line break, typ.200 ms; PROFINET MRP
Redundancy mode / Media redundancy / Number of stations in the ring, max.50
Open IE communication / TCP/IPYes; via integrated PROFINET interface and loadable FBs
Open IE communication / TCP/IP / Number of connections, max.8
Open IE communication / TCP/IP / Data length for connection type 01H, max.1 460 byte
Open IE communication / TCP/IP / Data length for connection type 11H, max.32 768 byte
Open IE communication / TCP/IP / several passive connections per port, supportedYes
Open IE communication / ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
Open IE communication / ISO-on-TCP (RFC1006) / Number of connections, max.8
Open IE communication / ISO-on-TCP (RFC1006) / Data length, max.32 768 byte
Open IE communication / UDPYes; via integrated PROFINET interface and loadable FBs
Open IE communication / UDP / Number of connections, max.8
Open IE communication / UDP / Data length, max.1 472 byte
Web server / supportedYes; only read function
Web server / User-defined websitesYes
Web server / Number of HTTP clients5
PG/OP communicationYes
Communication functions / Data record routingYes
Global data communication / supportedYes
Global data communication / Number of GD loops, max.8
Global data communication / Number of GD packets, max.8
Global data communication / Number of GD packets, transmitter, max.8
Global data communication / Number of GD packets, receiver, max.8
Global data communication / Size of GD packets, max.22 byte
Global data communication / Size of GD packet (of which consistent), max.22 byte
S7 basic communication / supportedYes
S7 basic communication / User data per job, max.76 byte
S7 basic communication / User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication / supportedYes
S7 communication / as serverYes
S7 communication / as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
S7 communication / User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication / supportedYes; via CP and loadable FC
PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load50 %
PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners32
PROFINET CBA (at set setpoint communication load) / number of master/device functions30
PROFINET CBA (at set setpoint communication load) / total of all master/device connections1 000
PROFINET CBA (at set setpoint communication load) / data length of all incoming master/device connections, max.4 000 byte
PROFINET CBA (at set setpoint communication load) / data length of all outgoing master/device connections, max.4 000 byte
PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnections500
PROFINET CBA (at set setpoint communication load) / Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
PROFINET CBA (at set setpoint communication load) / Data length per connection, max.1 400 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: Transmission interval, min.10 ms
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections200
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections200
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all incoming interconnections, max.2 000 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length of all outgoing interconnections, max.2 000 byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Data length per connection, max.450 byte
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating500 ms
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables200
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max.2 000 byte
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supportedYes
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Number of linked PROFIBUS devices16
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max.240 byte; Slave-dependent
Number of connections / overall16
Number of connections / usable for PG communication15
Number of connections / usable for PG communication / reserved for PG communication1
Number of connections / usable for PG communication / adjustable for PG communication, min.1
Number of connections / usable for PG communication / adjustable for PG communication, max.15
Number of connections / usable for OP communication15
Number of connections / usable for OP communication / reserved for OP communication1
Number of connections / usable for OP communication / adjustable for OP communication, min.1
Number of connections / usable for OP communication / adjustable for OP communication, max.15
Number of connections / usable for S7 basic communication14
Number of connections / usable for S7 basic communication / reserved for S7 basic communication0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, min.0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.14
Number of connections / usable for S7 communication14
Number of connections / usable for S7 communication / reserved for S7 communication0
Number of connections / usable for S7 communication / adjustable for S7 communication, min.0
Number of connections / usable for S7 communication / adjustable for S7 communication, max.14
Number of connections / total number of instances, max.32
Number of connections / usable for routingX1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions / Number of login stations for message functions, max.16; Depending on the configured connections for PG/OP and S7 basic communication
S7 message functions / Process diagnostic messagesYes
S7 message functions / simultaneously active Alarm_S blocks, max.300
Test commissioning functions / Status blockYes; Up to 2 simultaneously
Test commissioning functions / Single stepYes
Test commissioning functions / Number of breakpoints4
Status/control / Status/control variableYes
Status/control / VariablesInputs, outputs, memory bits, DB, times, counters
Status/control / Number of variables, max.30
Status/control / Number of variables, max. / of which status variables, max.30
Status/control / Number of variables, max. / of which control variables, max.14
Forcing / ForcingYes
Forcing / Forcing, variablesInputs, outputs
Forcing / Number of variables, max.10
Diagnostic buffer / presentYes
Diagnostic buffer / Number of entries, max.500
Diagnostic buffer / Number of entries, max. / can be setNo
Diagnostic buffer / Number of entries, max. / of which powerfail-proof100
Diagnostic buffer / Number of entries readable in RUN, max.499
Diagnostic buffer / Number of entries readable in RUN, max. / can be setYes
Diagnostic buffer / Number of entries readable in RUN, max. / preset10
Service data / Can be read outYes
Ambient temperature during operation / min.0 °C
Ambient temperature during operation / max.60 °C
Configuration software / STEP 7Yes; V5.5 or higher
Programming / Command setsee instruction list
Programming / Nesting levels8
Programming / System functions (SFC)see instruction list
Programming / System function blocks (SFB)see instruction list
Programming / Programming language / LADYes
Programming / Programming language / FBDYes
Programming / Programming language / STLYes
Programming / Programming language / SCLYes
Programming / Programming language / CFCYes
Programming / Programming language / GRAPHYes
Programming / Programming language / HiGraph®Yes
Know-how protection / User program protection/password protectionYes
Know-how protection / Block encryptionYes; With S7 block Privacy
Width40 mm
Height125 mm
Depth130 mm
Weight, approx.340 g
Phase-out announced (PM400)1 October 2023
Product cancellation (PM410)1 October 2025
Spare partYes, supplied by Siemens as a spare part only

Associated Products

ImageProductDescriptionStockViewAdd to RFQ
Siemens 6ES7315-2AH14-0AB0
6ES7315-2AH14-0AB0SiemensCPU 315-2 DP, 256 KB, MPI and PROFIBUS DPIn stockView
Siemens 6ES7315-2EH14-0AB0
6ES7315-2EH14-0AB0SiemensCPU 315-2 PN/DP, 384 KB, MPI/DP and PROFINETIn stockView
Siemens 6ES7312-1AE14-0AB0
6ES7312-1AE14-0AB0SiemensCPU 312, 32 KB, MPIIn stockView
Siemens 6ES7314-1AG14-0AB0
6ES7314-1AG14-0AB0SiemensCPU 314, 128 KB, MPIIn stockView
Siemens 6ES7313-6CG04-0AB0
6ES7313-6CG04-0AB0SiemensCPU 313C-2 DP compact CPU, 16 DI/16 DO, MPI and PROFIBUS DPIn stockView
Siemens 6ES7314-6CH04-0AB0
6ES7314-6CH04-0AB0SiemensCPU 314C-2 DP compact CPU with integrated I/O, MPI and PROFIBUS DPIn stockView
Siemens 6ES7317-2AK14-0AB0
6ES7317-2AK14-0AB0SiemensCPU 317-2 DP, 1 MB, MPI/DP and PROFIBUS DPIn stockView
Siemens 6ES7312-5BF04-0AB0
6ES7312-5BF04-0AB0SiemensCPU 312C compact, 64 KB, 10 DI/6 DO, MPIIn stockView
Siemens 6ES7318-3EL01-0AB0
6ES7318-3EL01-0AB0SiemensCPU 319-3 PN/DP, 2 MB, MPI/DP, DP and PROFINETIn stockView
Siemens 6ES7315-6FF04-0AB0
6ES7315-6FF04-0AB0SiemensCPU 315F-2 DP fail-safe, 384 KB, MPI and DPIn stockView
Siemens 6ES7317-6FF04-0AB0
6ES7317-6FF04-0AB0SiemensCPU 317F-2 DP fail-safe, 1.5 MB, MPI/DP and DPIn stockView
Siemens 6ES7317-2FK14-0AB0
6ES7317-2FK14-0AB0SiemensCPU 317F-2 PN/DP fail-safe, 1.5 MB, MPI/DP and PROFINETIn stockView

Product Questions

Is the 6ES7315-2FJ14-0AB0 discontinued?

Yes. Its manufacturer lifecycle status is Discontinued.

Can another Siemens SIMATIC S7-300 part replace it?

Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.

Do you ship worldwide?

Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.

Related Products

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need a part? Send us the part number.

Added to cart