Siemens 6ES7317-6FF04-0AB0

CPU 317F-2 DP fail-safe, 1.5 MB, MPI/DP and DP

Request a quote
Siemens
Siemens 6ES7317-6FF04-0AB0 CPU 317F-2 DP fail-safe, photo from Siemens data sheet 6ES7317-6FF04-0AB0

Image is for illustrative purposes only. Please refer to product description.

  • FedEx
  • DHL
  • UPS
Manufacturer
Siemens
Manufacturer part number
6ES7317-6FF04-0AB0
Technical datasheet
Data sheet

Specifications

AttributeValue
TypeSafety PLC CPU (F-CPU)
Manufacturer lifecycleDiscontinued
Product type designationCPU 317F-2 DP
HW functional status01
Firmware versionV3.3
Engineering with / Programming packageSTEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 202 + Distributed Safety
Supply voltage / Rated value (DC)24 V
Supply voltage / permissible range, lower limit (DC)19.2 V
Supply voltage / permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Input current / Current consumption (rated value)870 mA
Input current / Current consumption (in no-load operation), typ.120 mA
Input current / Inrush current, typ.4 A
Input current / I²t1 A²·s
Power loss, typ.4.5 W
Show all 260 specifications
Work memory / integrated1 536 kbyte
Work memory / expandableNo
Load memory / Plug-in (MMC)Yes
Load memory / Plug-in (MMC), max.8 Mbyte
Load memory / Data management on MMC (after last programming), min.10 a
Backup / presentYes; Guaranteed by MMC (maintenance-free)
Backup / without batteryYes; Program and data
CPU processing times / for bit operations, typ.0.025 µs
CPU processing times / for word operations, typ.0.03 µs
CPU processing times / for fixed point arithmetic, typ.0.04 µs
CPU processing times / for floating point arithmetic, typ.0.16 µs
CPU-blocks / Number of elements (total)2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB / Number, max.2 048; Number range: 1 to 16000
DB / Size, max.64 kbyte
FB / Number, max.2 048; Number range: 0 to 7999
FB / Size, max.64 kbyte
FC / Number, max.2 048; Number range: 0 to 7999
FC / Size, max.64 kbyte
OB / Number, max.see instruction list
OB / Size, max.64 kbyte
OB / Number of free cycle OBs1; OB 1
OB / Number of time alarm OBs1; OB 10
OB / Number of delay alarm OBs2; OB 20, 21
OB / Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
OB / Number of process alarm OBs1; OB 40
OB / Number of DPV1 alarm OBs3; OB 55, 56, 57
OB / Number of isochronous mode OBs1; OB 61
OB / Number of startup OBs1; OB 100
OB / Number of asynchronous error OBs5; OB 80, 82, 85, 86, 87
OB / Number of synchronous error OBs2; OB 121, 122
Nesting depth / per priority class16
Nesting depth / additional within an error OB4
S7 counter / Number512
S7 counter / Retentivity / adjustableYes
S7 counter / Retentivity / presetZ 0 to Z 7
S7 counter / Counting range / lower limit0
S7 counter / Counting range / upper limit999
IEC counter / presentYes
IEC counter / TypeSFB
IEC counter / NumberUnlimited (limited only by RAM capacity)
S7 timer / Number512
S7 timer / Retentivity / adjustableYes
S7 timer / Retentivity / presetNo retentivity
S7 timer / Time range / lower limit10 ms
S7 timer / Time range / upper limit9 990 s
IEC timer / presentYes
IEC timer / TypeSFB
IEC timer / NumberUnlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.256 kbyte
Flag / Size, max.4 096 byte
Flag / Retentivity availableYes; From MB 0 to MB 4 095
Flag / Retentivity presetMB 0 to MB 15
Flag / Number of clock memories8; 1 memory byte
Data blocks / Retentivity adjustableYes; via non-retain property on DB
Data blocks / Retentivity presetYes
Local data / per priority class, max.32 768 byte; Max. 2048 bytes per block
I/O address area / Inputs8 192 byte
I/O address area / Outputs8 192 byte
I/O address area / of which distributed / Inputs8 192 byte
I/O address area / of which distributed / Outputs8 192 byte
Process image / Inputs8 192 byte
Process image / Outputs8 192 byte
Process image / Inputs, adjustable8 192 byte
Process image / Outputs, adjustable8 192 byte
Process image / Inputs, default1 024 byte
Process image / Outputs, default1 024 byte
Subprocess images / Number of subprocess images, max.1
Digital channels / Inputs65 536
Digital channels / Inputs / of which central1 024
Digital channels / Outputs65 536
Digital channels / Outputs / of which central1 024
Analog channels / Inputs4 096
Analog channels / Inputs / of which central256
Analog channels / Outputs4 096
Analog channels / Outputs / of which central256
Hardware configuration / Number of expansion units, max.3
Number of DP masters / integrated2
Number of DP masters / via CP4
Number of operable FMs and CPs (recommended) / FM8
Number of operable FMs and CPs (recommended) / CP, PtP8
Number of operable FMs and CPs (recommended) / CP, LAN10
Rack / Racks, max.4
Rack / Modules per rack, max.8
Clock / Hardware clock (real-time)Yes
Clock / retentive and synchronizableYes
Clock / Backup time6 wk; At 40 °C ambient temperature
Clock / Deviation per day, max.10 s; Typ.: 2 s
Clock / Behavior of the clock following POWER-ONClock continues running after POWER OFF
Clock / Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Operating hours counter / Number4
Operating hours counter / Number/Number range0 to 3
Operating hours counter / Range of values0 to 2^31 hours (when using SFC 101)
Operating hours counter / Granularity1 h
Operating hours counter / retentiveYes; Must be restarted at each restart
Clock synchronization / supportedYes
Clock synchronization / to MPI, masterYes
Clock synchronization / on MPI, deviceYes
Clock synchronization / to DP, masterYes; With DP slave only slave clock
Clock synchronization / on DP, deviceYes
Clock synchronization / in AS, masterYes
Clock synchronization / in AS, deviceYes
Clock synchronization / on Ethernet via NTPNo
Number of digital inputs0
Number of digital outputs0
Number of analog inputs0
Number of PROFINET interfaces0
Number of RS 485 interfaces2
Number of RS 422 interfaces0
1. Interface / Interface typeIntegrated RS 485 interface
1. Interface / IsolatedYes
Interface types / RS 485Yes
Interface types / Output current of the interface, max.200 mA
1. Interface / Protocols / MPIYes
Protocols / PROFIBUS DP masterYes
Protocols / PROFIBUS DP deviceYes; A DP slave at both interfaces simultaneously is not possible
Protocols / Point-to-point connectionNo
MPI / Transmission rate, max.12 Mbit/s
MPI / Services / PG/OP communicationYes
MPI / Services / RoutingYes
MPI / Services / Global data communicationYes
MPI / Services / S7 basic communicationYes
MPI / Services / S7 communicationYes; Only server, configured on one side
MPI / Services / S7 communication, as clientNo; but via CP and loadable FB
MPI / Services / S7 communication, as serverYes
PROFIBUS DP master / Transmission rate, max.12 Mbit/s
PROFIBUS DP master / max. number of DP devices124
PROFIBUS DP master / Services / PG/OP communicationYes
PROFIBUS DP master / Services / RoutingYes
PROFIBUS DP master / Services / Global data communicationNo
PROFIBUS DP master / Services / S7 basic communicationYes; I blocks only
PROFIBUS DP master / Services / S7 communicationYes; Only server, configured on one side
1. Interface / PROFIBUS DP master / Services / S7 communication, as clientNo
PROFIBUS DP master / Services / S7 communication, as serverYes
PROFIBUS DP master / Services / EquidistanceYes
1. Interface / PROFIBUS DP master / Services / Isochronous modeNo
PROFIBUS DP master / Services / SYNC/FREEZEYes
PROFIBUS DP master / Services / activation/deactivation of DP devicesYes
PROFIBUS DP master / Services / max. number of DP devices that can be activated/deactivated at the same time8
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)Yes; as subscriber
PROFIBUS DP master / Services / DPV1Yes
1. Interface / PROFIBUS DP master / Address area / Inputs, max.8 kbyte
1. Interface / PROFIBUS DP master / Address area / Outputs, max.8 kbyte
PROFIBUS DP master / User data per DP device / Inputs, max.244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.244 byte
PROFIBUS DP device / Transmission rate, max.12 Mbit/s
PROFIBUS DP device / automatic baud rate searchYes; only with passive interface
PROFIBUS DP device / Address area, max.32
PROFIBUS DP device / User data per address area, max.32 byte
PROFIBUS DP device / Services / PG/OP communicationYes
PROFIBUS DP device / Services / RoutingYes; Only with active interface
PROFIBUS DP device / Services / Global data communicationNo
PROFIBUS DP device / Services / S7 basic communicationNo
PROFIBUS DP device / Services / S7 communicationYes; Only server, configured on one side
1. Interface / PROFIBUS DP device / Services / S7 communication, as clientNo
1. Interface / PROFIBUS DP device / Services / S7 communication, as serverYes; Connection configured on one side only
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)Yes
PROFIBUS DP device / Services / DPV1No
PROFIBUS DP device / Transfer memory / Inputs244 byte
PROFIBUS DP device / Transfer memory / Outputs244 byte
2. Interface / Interface typeIntegrated RS 485 interface
2. Interface / IsolatedYes
2. Interface / Protocols / MPINo
2. Interface / PROFIBUS DP master / Services / S7 communication, as clientNo; but via CP and loadable FB
2. Interface / PROFIBUS DP master / Services / Isochronous modeYes; OB 61
2. Interface / PROFIBUS DP master / Address area / Inputs, max.8 192 byte
2. Interface / PROFIBUS DP master / Address area / Outputs, max.8 192 byte
2. Interface / PROFIBUS DP device / Services / S7 communication, as clientNo; but via CP and loadable FB
2. Interface / PROFIBUS DP device / Services / S7 communication, as serverYes
Protocols / PROFIsafeNo
PG/OP communicationYes
Communication functions / Data record routingYes
Global data communication / supportedYes
Global data communication / Number of GD loops, max.8
Global data communication / Number of GD packets, max.8
Global data communication / Number of GD packets, transmitter, max.8
Global data communication / Number of GD packets, receiver, max.8
Global data communication / Size of GD packets, max.22 byte
Global data communication / Size of GD packet (of which consistent), max.22 byte
S7 basic communication / supportedYes
S7 basic communication / User data per job, max.76 byte
S7 basic communication / User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication / supportedYes
S7 communication / as serverYes
S7 communication / as clientYes; Via CP and loadable FB
S7 communication / User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication / supportedYes; via CP and loadable FC
Number of connections / overall32
Number of connections / usable for PG communication31
Number of connections / usable for PG communication / reserved for PG communication1
Number of connections / usable for PG communication / adjustable for PG communication, min.1
Number of connections / usable for PG communication / adjustable for PG communication, max.31
Number of connections / usable for OP communication31
Number of connections / usable for OP communication / reserved for OP communication1
Number of connections / usable for OP communication / adjustable for OP communication, min.1
Number of connections / usable for OP communication / adjustable for OP communication, max.31
Number of connections / usable for S7 basic communication30
Number of connections / usable for S7 basic communication / reserved for S7 basic communication0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, min.0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.30
Number of connections / usable for routingX1 as a MPI, max. 10; X1 as DP Master max. 24; X1 as DP Slave (active) max. 14; X2 as DP Master max. 24; X2 as DP Slave (active) max. 14
S7 message functions / Number of login stations for message functions, max.32; Depending on the configured connections for PG/OP and S7 basic communication
S7 message functions / Process diagnostic messagesYes
S7 message functions / simultaneously active Alarm_S blocks, max.300
Test commissioning functions / Status blockYes; Up to 2 simultaneously
Test commissioning functions / Single stepYes
Test commissioning functions / Number of breakpoints4
Status/control / Status/control variableYes
Status/control / VariablesInputs, outputs, memory bits, DB, times, counters
Status/control / Number of variables, max.30
Status/control / Number of variables, max. / of which status variables, max.30
Status/control / Number of variables, max. / of which control variables, max.14
Forcing / ForcingYes
Forcing / Forcing, variablesInputs, outputs
Forcing / Number of variables, max.10
Diagnostic buffer / presentYes
Diagnostic buffer / Number of entries, max.500
Diagnostic buffer / Number of entries, max. / can be setNo
Diagnostic buffer / Number of entries, max. / of which powerfail-proof100; Only the last 100 entries are retained
Diagnostic buffer / Number of entries readable in RUN, max.499
Diagnostic buffer / Number of entries readable in RUN, max. / can be setYes; From 10 to 499
Diagnostic buffer / Number of entries readable in RUN, max. / preset10
Service data / Can be read outYes
Ambient temperature during operation / min.0 °C
Ambient temperature during operation / max.60 °C
Configuration software / STEP 7Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
Configuration software / STEP 7 LiteNo
Programming / Command setsee instruction list
Programming / Nesting levels8
Programming / System functions (SFC)see instruction list
Programming / System function blocks (SFB)see instruction list
Programming / Programming language / LADYes
Programming / Programming language / FBDYes
Programming / Programming language / STLYes
Programming / Programming language / SCLYes
Programming / Programming language / CFCYes
Programming / Programming language / GRAPHYes
Programming / Programming language / HiGraph®Yes
Know-how protection / User program protection/password protectionYes
Know-how protection / Block encryptionYes; With S7 block Privacy
Width40 mm
Height125 mm
Depth130 mm
Phase-out announced (PM400)1 October 2023
Product cancellation (PM410)1 October 2025
Spare partYes, supplied by Siemens as a spare part only

Associated Products

ImageProductDescriptionStockViewAdd to RFQ
Siemens 6ES7317-2EK14-0AB0
6ES7317-2EK14-0AB0SiemensCPU 317-2 PN/DP, 1 MB, MPI/DP and PROFINETIn stockView
Siemens 6ES7313-5BG04-0AB0
6ES7313-5BG04-0AB0SiemensCPU 313C compact CPU with integrated I/O, MPIIn stockView
Siemens 6ES7312-1AE14-0AB0
6ES7312-1AE14-0AB0SiemensCPU 312, 32 KB, MPIIn stockView
Siemens 6ES7314-1AG14-0AB0
6ES7314-1AG14-0AB0SiemensCPU 314, 128 KB, MPIIn stockView
Siemens 6ES7313-6CG04-0AB0
6ES7313-6CG04-0AB0SiemensCPU 313C-2 DP compact CPU, 16 DI/16 DO, MPI and PROFIBUS DPIn stockView
Siemens 6ES7314-6CH04-0AB0
6ES7314-6CH04-0AB0SiemensCPU 314C-2 DP compact CPU with integrated I/O, MPI and PROFIBUS DPIn stockView
Siemens 6ES7317-2AK14-0AB0
6ES7317-2AK14-0AB0SiemensCPU 317-2 DP, 1 MB, MPI/DP and PROFIBUS DPIn stockView
Siemens 6ES7312-5BF04-0AB0
6ES7312-5BF04-0AB0SiemensCPU 312C compact, 64 KB, 10 DI/6 DO, MPIIn stockView
Siemens 6ES7318-3EL01-0AB0
6ES7318-3EL01-0AB0SiemensCPU 319-3 PN/DP, 2 MB, MPI/DP, DP and PROFINETIn stockView
Siemens 6ES7315-6FF04-0AB0
6ES7315-6FF04-0AB0SiemensCPU 315F-2 DP fail-safe, 384 KB, MPI and DPIn stockView
Siemens 6ES7315-2FJ14-0AB0
6ES7315-2FJ14-0AB0SiemensCPU 315F-2 PN/DP fail-safe, 512 KB, MPI/DP and PROFINETIn stockView
Siemens 6ES7317-2FK14-0AB0
6ES7317-2FK14-0AB0SiemensCPU 317F-2 PN/DP fail-safe, 1.5 MB, MPI/DP and PROFINETIn stockView

Product Questions

Is the 6ES7317-6FF04-0AB0 discontinued?

Yes. Its manufacturer lifecycle status is Discontinued.

Can another Siemens SIMATIC S7-300 part replace it?

Potential replacements must be checked against the required ratings, dimensions and connections. Sharing a family name does not establish interchangeability.

Do you ship worldwide?

Yes. TimControls ships worldwide. Parts usually ship within 3 to 7 working days of order confirmation, and the exact lead time and shipping options are stated on your quote. Include your delivery country and postal code when you ask for a quote.

Related Products

  • Siemens

    6ES7321-1BL00-0AA0

    SM 321 digital input, 32 DI, 24 V DC

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7307-1KA02-0AA0

    PS307 power supply, 120/230 V AC in, 24 V DC 10 A out

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7307-1EA01-0AA0

    PS307 power supply, 120/230 V AC in, 24 V DC 5 A out

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6AG1321-1BL00-2AA0

    SIPLUS SM 321 digital input, 32 DI, 24 V DC, conformal coating

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7365-0BA01-0AA0

    IM 365 interface module pair, one expansion rack, with 1 m cable

    Same SIMATIC S7-300 system

    In stock

  • Siemens

    6ES7360-3AA01-0AA0

    IM 360 interface module, central rack, up to 3 expansion racks

    Same SIMATIC S7-300 system

    In stock

TimControls is an independent distributor. Manufacturer names and logos are the property of their respective owners and identify products we source; they do not imply manufacturer authorization or affiliation.

Need a part? Send us the part number.

Added to cart