6ES7317-6FF04-0AB0

Siemens CPU 317F-2 DP fail-safe, 1.5 MB, MPI/DP and DP

Siemens
Siemens 6ES7317-6FF04-0AB0 CPU 317F-2 DP fail-safe, photo from Siemens data sheet 6ES7317-6FF04-0AB0

Image is for illustrative purposes only. Please refer to product description.

Delivery options

  • FedEx
  • DHL
  • UPS

Siemens SIMATIC S7-300 CPU 317F-2 DP: fail-safe CPU with 1.5 MB work memory, an MPI/DP interface and a second PROFIBUS DP interface; used with S7 Distributed Safety; Micro Memory Card required.

Manufacturer
Siemens
Manufacturer part no.
6ES7317-6FF04-0AB0
Type
Safety PLC CPU (F-CPU)
Lifecycle
Discontinued
OEM successor
Not stated
Technical datasheet
Data sheet

Technical specifications

Manufacturer
Siemens
Manufacturer part no.
6ES7317-6FF04-0AB0
Type
Safety PLC CPU (F-CPU)
Application
PLC controller
Used with
SIMATIC S7-300 rack (S7-300 backplane bus)
Product type designation
CPU 317F-2 DP
HW functional status
01
Firmware version
V3.3
Engineering with / Programming package
STEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 202 + Distributed Safety
Supply voltage / Rated value (DC)
24 V
Supply voltage / permissible range, lower limit (DC)
19.2 V
Supply voltage / permissible range, upper limit (DC)
28.8 V
external protection for power supply lines (recommendation)
2 A min.
Input current / Current consumption (rated value)
870 mA
Input current / Current consumption (in no-load operation), typ.
120 mA
Input current / Inrush current, typ.
4 A
Input current / I²t
1 A²·s
Power loss, typ.
4.5 W
Work memory / integrated
1 536 kbyte
Work memory / expandable
No
Load memory / Plug-in (MMC)
Yes
Load memory / Plug-in (MMC), max.
8 Mbyte
Load memory / Data management on MMC (after last programming), min.
10 a
Backup / present
Yes; Guaranteed by MMC (maintenance-free)
Backup / without battery
Yes; Program and data
CPU processing times / for bit operations, typ.
0.025 µs
CPU processing times / for word operations, typ.
0.03 µs
CPU processing times / for fixed point arithmetic, typ.
0.04 µs
CPU processing times / for floating point arithmetic, typ.
0.16 µs
CPU-blocks / Number of elements (total)
2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
Show all 260 specifications
DB / Number, max.
2 048; Number range: 1 to 16000
DB / Size, max.
64 kbyte
FB / Number, max.
2 048; Number range: 0 to 7999
FB / Size, max.
64 kbyte
FC / Number, max.
2 048; Number range: 0 to 7999
FC / Size, max.
64 kbyte
OB / Number, max.
see instruction list
OB / Size, max.
64 kbyte
OB / Number of free cycle OBs
1; OB 1
OB / Number of time alarm OBs
1; OB 10
OB / Number of delay alarm OBs
2; OB 20, 21
OB / Number of cyclic interrupt OBs
4; OB 32, 33, 34, 35
OB / Number of process alarm OBs
1; OB 40
OB / Number of DPV1 alarm OBs
3; OB 55, 56, 57
OB / Number of isochronous mode OBs
1; OB 61
OB / Number of startup OBs
1; OB 100
OB / Number of asynchronous error OBs
5; OB 80, 82, 85, 86, 87
OB / Number of synchronous error OBs
2; OB 121, 122
Nesting depth / per priority class
16
Nesting depth / additional within an error OB
4
S7 counter / Number
512
S7 counter / Retentivity / adjustable
Yes
S7 counter / Retentivity / preset
Z 0 to Z 7
S7 counter / Counting range / lower limit
0
S7 counter / Counting range / upper limit
999
IEC counter / present
Yes
IEC counter / Type
SFB
IEC counter / Number
Unlimited (limited only by RAM capacity)
S7 timer / Number
512
S7 timer / Retentivity / adjustable
Yes
S7 timer / Retentivity / preset
No retentivity
S7 timer / Time range / lower limit
10 ms
S7 timer / Time range / upper limit
9 990 s
IEC timer / present
Yes
IEC timer / Type
SFB
IEC timer / Number
Unlimited (limited only by RAM capacity)
Retentive data area (incl. timers, counters, flags), max.
256 kbyte
Flag / Size, max.
4 096 byte
Flag / Retentivity available
Yes; From MB 0 to MB 4 095
Flag / Retentivity preset
MB 0 to MB 15
Flag / Number of clock memories
8; 1 memory byte
Data blocks / Retentivity adjustable
Yes; via non-retain property on DB
Data blocks / Retentivity preset
Yes
Local data / per priority class, max.
32 768 byte; Max. 2048 bytes per block
I/O address area / Inputs
8 192 byte
I/O address area / Outputs
8 192 byte
I/O address area / of which distributed / Inputs
8 192 byte
I/O address area / of which distributed / Outputs
8 192 byte
Process image / Inputs
8 192 byte
Process image / Outputs
8 192 byte
Process image / Inputs, adjustable
8 192 byte
Process image / Outputs, adjustable
8 192 byte
Process image / Inputs, default
1 024 byte
Process image / Outputs, default
1 024 byte
Subprocess images / Number of subprocess images, max.
1
Digital channels / Inputs
65 536
Digital channels / Inputs / of which central
1 024
Digital channels / Outputs
65 536
Digital channels / Outputs / of which central
1 024
Analog channels / Inputs
4 096
Analog channels / Inputs / of which central
256
Analog channels / Outputs
4 096
Analog channels / Outputs / of which central
256
Hardware configuration / Number of expansion units, max.
3
Number of DP masters / integrated
2
Number of DP masters / via CP
4
Number of operable FMs and CPs (recommended) / FM
8
Number of operable FMs and CPs (recommended) / CP, PtP
8
Number of operable FMs and CPs (recommended) / CP, LAN
10
Rack / Racks, max.
4
Rack / Modules per rack, max.
8
Clock / Hardware clock (real-time)
Yes
Clock / retentive and synchronizable
Yes
Clock / Backup time
6 wk; At 40 °C ambient temperature
Clock / Deviation per day, max.
10 s; Typ.: 2 s
Clock / Behavior of the clock following POWER-ON
Clock continues running after POWER OFF
Clock / Behavior of the clock following expiry of backup period
the clock continues at the time of day it had when power was switched off
Operating hours counter / Number
4
Operating hours counter / Number/Number range
0 to 3
Operating hours counter / Range of values
0 to 2^31 hours (when using SFC 101)
Operating hours counter / Granularity
1 h
Operating hours counter / retentive
Yes; Must be restarted at each restart
Clock synchronization / supported
Yes
Clock synchronization / to MPI, master
Yes
Clock synchronization / on MPI, device
Yes
Clock synchronization / to DP, master
Yes; With DP slave only slave clock
Clock synchronization / on DP, device
Yes
Clock synchronization / in AS, master
Yes
Clock synchronization / in AS, device
Yes
Clock synchronization / on Ethernet via NTP
No
Number of digital inputs
0
Number of digital outputs
0
Number of analog inputs
0
Number of PROFINET interfaces
0
Number of RS 485 interfaces
2
Number of RS 422 interfaces
0
1. Interface / Interface type
Integrated RS 485 interface
1. Interface / Isolated
Yes
Interface types / RS 485
Yes
Interface types / Output current of the interface, max.
200 mA
1. Interface / Protocols / MPI
Yes
Protocols / PROFIBUS DP master
Yes
Protocols / PROFIBUS DP device
Yes; A DP slave at both interfaces simultaneously is not possible
Protocols / Point-to-point connection
No
MPI / Transmission rate, max.
12 Mbit/s
MPI / Services / PG/OP communication
Yes
MPI / Services / Routing
Yes
MPI / Services / Global data communication
Yes
MPI / Services / S7 basic communication
Yes
MPI / Services / S7 communication
Yes; Only server, configured on one side
MPI / Services / S7 communication, as client
No; but via CP and loadable FB
MPI / Services / S7 communication, as server
Yes
PROFIBUS DP master / Transmission rate, max.
12 Mbit/s
PROFIBUS DP master / max. number of DP devices
124
PROFIBUS DP master / Services / PG/OP communication
Yes
PROFIBUS DP master / Services / Routing
Yes
PROFIBUS DP master / Services / Global data communication
No
PROFIBUS DP master / Services / S7 basic communication
Yes; I blocks only
PROFIBUS DP master / Services / S7 communication
Yes; Only server, configured on one side
1. Interface / PROFIBUS DP master / Services / S7 communication, as client
No
PROFIBUS DP master / Services / S7 communication, as server
Yes
PROFIBUS DP master / Services / Equidistance
Yes
1. Interface / PROFIBUS DP master / Services / Isochronous mode
No
PROFIBUS DP master / Services / SYNC/FREEZE
Yes
PROFIBUS DP master / Services / activation/deactivation of DP devices
Yes
PROFIBUS DP master / Services / max. number of DP devices that can be activated/deactivated at the same time
8
PROFIBUS DP master / Services / Direct data exchange (slave-to-slave communication)
Yes; as subscriber
PROFIBUS DP master / Services / DPV1
Yes
1. Interface / PROFIBUS DP master / Address area / Inputs, max.
8 kbyte
1. Interface / PROFIBUS DP master / Address area / Outputs, max.
8 kbyte
PROFIBUS DP master / User data per DP device / Inputs, max.
244 byte
PROFIBUS DP master / User data per DP device / Outputs, max.
244 byte
PROFIBUS DP device / Transmission rate, max.
12 Mbit/s
PROFIBUS DP device / automatic baud rate search
Yes; only with passive interface
PROFIBUS DP device / Address area, max.
32
PROFIBUS DP device / User data per address area, max.
32 byte
PROFIBUS DP device / Services / PG/OP communication
Yes
PROFIBUS DP device / Services / Routing
Yes; Only with active interface
PROFIBUS DP device / Services / Global data communication
No
PROFIBUS DP device / Services / S7 basic communication
No
PROFIBUS DP device / Services / S7 communication
Yes; Only server, configured on one side
1. Interface / PROFIBUS DP device / Services / S7 communication, as client
No
1. Interface / PROFIBUS DP device / Services / S7 communication, as server
Yes; Connection configured on one side only
PROFIBUS DP device / Services / Direct data exchange (slave-to-slave communication)
Yes
PROFIBUS DP device / Services / DPV1
No
PROFIBUS DP device / Transfer memory / Inputs
244 byte
PROFIBUS DP device / Transfer memory / Outputs
244 byte
2. Interface / Interface type
Integrated RS 485 interface
2. Interface / Isolated
Yes
2. Interface / Protocols / MPI
No
2. Interface / PROFIBUS DP master / Services / S7 communication, as client
No; but via CP and loadable FB
2. Interface / PROFIBUS DP master / Services / Isochronous mode
Yes; OB 61
2. Interface / PROFIBUS DP master / Address area / Inputs, max.
8 192 byte
2. Interface / PROFIBUS DP master / Address area / Outputs, max.
8 192 byte
2. Interface / PROFIBUS DP device / Services / S7 communication, as client
No; but via CP and loadable FB
2. Interface / PROFIBUS DP device / Services / S7 communication, as server
Yes
Protocols / PROFIsafe
No
PG/OP communication
Yes
Communication functions / Data record routing
Yes
Global data communication / supported
Yes
Global data communication / Number of GD loops, max.
8
Global data communication / Number of GD packets, max.
8
Global data communication / Number of GD packets, transmitter, max.
8
Global data communication / Number of GD packets, receiver, max.
8
Global data communication / Size of GD packets, max.
22 byte
Global data communication / Size of GD packet (of which consistent), max.
22 byte
S7 basic communication / supported
Yes
S7 basic communication / User data per job, max.
76 byte
S7 basic communication / User data per job (of which consistent), max.
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication / supported
Yes
S7 communication / as server
Yes
S7 communication / as client
Yes; Via CP and loadable FB
S7 communication / User data per job, max.
See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication / supported
Yes; via CP and loadable FC
Number of connections / overall
32
Number of connections / usable for PG communication
31
Number of connections / usable for PG communication / reserved for PG communication
1
Number of connections / usable for PG communication / adjustable for PG communication, min.
1
Number of connections / usable for PG communication / adjustable for PG communication, max.
31
Number of connections / usable for OP communication
31
Number of connections / usable for OP communication / reserved for OP communication
1
Number of connections / usable for OP communication / adjustable for OP communication, min.
1
Number of connections / usable for OP communication / adjustable for OP communication, max.
31
Number of connections / usable for S7 basic communication
30
Number of connections / usable for S7 basic communication / reserved for S7 basic communication
0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, min.
0
Number of connections / usable for S7 basic communication / adjustable for S7 basic communication, max.
30
Number of connections / usable for routing
X1 as a MPI, max. 10; X1 as DP Master max. 24; X1 as DP Slave (active) max. 14; X2 as DP Master max. 24; X2 as DP Slave (active) max. 14
S7 message functions / Number of login stations for message functions, max.
32; Depending on the configured connections for PG/OP and S7 basic communication
S7 message functions / Process diagnostic messages
Yes
S7 message functions / simultaneously active Alarm_S blocks, max.
300
Test commissioning functions / Status block
Yes; Up to 2 simultaneously
Test commissioning functions / Single step
Yes
Test commissioning functions / Number of breakpoints
4
Status/control / Status/control variable
Yes
Status/control / Variables
Inputs, outputs, memory bits, DB, times, counters
Status/control / Number of variables, max.
30
Status/control / Number of variables, max. / of which status variables, max.
30
Status/control / Number of variables, max. / of which control variables, max.
14
Forcing / Forcing
Yes
Forcing / Forcing, variables
Inputs, outputs
Forcing / Number of variables, max.
10
Diagnostic buffer / present
Yes
Diagnostic buffer / Number of entries, max.
500
Diagnostic buffer / Number of entries, max. / can be set
No
Diagnostic buffer / Number of entries, max. / of which powerfail-proof
100; Only the last 100 entries are retained
Diagnostic buffer / Number of entries readable in RUN, max.
499
Diagnostic buffer / Number of entries readable in RUN, max. / can be set
Yes; From 10 to 499
Diagnostic buffer / Number of entries readable in RUN, max. / preset
10
Service data / Can be read out
Yes
Ambient temperature during operation / min.
0 °C
Ambient temperature during operation / max.
60 °C
Configuration software / STEP 7
Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
Configuration software / STEP 7 Lite
No
Programming / Command set
see instruction list
Programming / Nesting levels
8
Programming / System functions (SFC)
see instruction list
Programming / System function blocks (SFB)
see instruction list
Programming / Programming language / LAD
Yes
Programming / Programming language / FBD
Yes
Programming / Programming language / STL
Yes
Programming / Programming language / SCL
Yes
Programming / Programming language / CFC
Yes
Programming / Programming language / GRAPH
Yes
Programming / Programming language / HiGraph®
Yes
Know-how protection / User program protection/password protection
Yes
Know-how protection / Block encryption
Yes; With S7 block Privacy
Width
40 mm
Height
125 mm
Depth
130 mm

Technical documents (1)

Key features

  • Fail-safe CPU for standard and safety programs
  • 1.5 MB integrated work memory
  • 1st interface MPI/DP 12 Mbit/s
  • 2nd interface PROFIBUS DP master/slave
  • Used with S7 Distributed Safety V5.2 SP1 or higher
  • Siemens lists it as a spare part

About the Siemens 6ES7317-6FF04-0AB0

The Siemens 6ES7317-6FF04-0AB0 is the CPU 317F-2 DP, a fail-safe S7-300 CPU. Siemens's data sheet gives it 1.5 MB of integrated work memory, a combined MPI/PROFIBUS DP interface at 12 Mbit/s and a second PROFIBUS DP interface, and says it is used with the software package S7 Distributed Safety V5.2 SP1 or higher. The program is held on a Micro Memory Card. Siemens's data sheet marks it as a spare part.

What is the 6ES7317-6FF04-0AB0 used for?

It runs larger machine and line programs together with their safety functions, with fail-safe I/O on PROFIBUS DP. As a fail-safe CPU its safety program and configuration must be checked against the replacement before it goes back into service.

Lifecycle and successor

Discontinued.

Before you order

What to photograph or confirm so the right unit is quoted.

Check the full order number and the firmware version on the CPU's label, and read the program size from the project if you can: a replacement must match or exceed the work memory. The Micro Memory Card (MMC) holding the program is a separate part; send its order number and size too.

Alternatives for 6ES7317-6FF04-0AB0

The manufacturer’s named successor and other parts in the same family. None is a drop-in replacement without checking wiring, I/O and configuration for your installation.

ProductManufacturerTypeLifecycleRelationshipQty AvailablePriceAction
Siemens 6ES7315-2AH14-0AB0CPU 315-2 DP, 256 KB, MPI and PROFIBUS DPSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7315-2EH14-0AB0CPU 315-2 PN/DP, 384 KB, MPI/DP and PROFINETSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7317-2EK14-0AB0CPU 317-2 PN/DP, 1 MB, MPI/DP and PROFINETSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7314-6EH04-0AB0CPU 314C-2 PN/DP compact CPU with integrated I/OSiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7313-5BG04-0AB0CPU 313C compact CPU with integrated I/O, MPISiemensPLC CPUDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7321-1BL00-0AA0SM 321 digital input, 32 DI, 24 V DCSiemensDigital input moduleDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7322-1BL00-0AA0SM 322 digital output, 32 DO, 24 V DC, 0.5 ASiemensDigital output moduleDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7331-7KF02-0AB0SM 331 analog input, 8 AI, U/I/thermocouple/resistanceSiemensAnalog input moduleDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7332-5HF00-0AB0SM 332 analog output, 8 AO, voltage/currentSiemensAnalog output moduleDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6ES7307-1EA01-0AA0PS307 power supply, 120/230 V AC in, 24 V DC 5 A outSiemensPower supplyPhased outSame familyOn RequestOn requestView ›
Siemens 6GK7343-1CX10-0XE0CP 343-1 Lean communications processor, Industrial EthernetSiemensCommunications processorDiscontinuedSame familyOn RequestOn requestView ›
Siemens 6GK7343-1EX30-0XE0CP 343-1 communications processor, Industrial Ethernet, PROFINET IO controllerSiemensCommunications processorDiscontinuedSame familyOn RequestOn requestView ›